Skip to main content

Helical TomoTherapy System

  • Chapter
Stereotactic Body Radiation Therapy

Part of the book series: Medical Radiology ((Med Radiol Radiat Oncol))

Abstract

Stereotactic body radiation therapy (SBRT) treatments are characterized by high dose conformality to the target with steep dose gradients, so even slight patient misalignment from patient simulation to treatment could lead to a geographical miss resulting in underdosing of the target or overdosing of organs at risk (OARs). The role of the numerous imaging modalities available for SBRT treatments is crucial for precise delivery of radiation treatments. Furthermore, many treatment delivery techniques are available and may prove advantageous for site-specific SBRT treatments. In recent years, image guidance has matured sufficiently to allow acquisition of volumetric image data sets by treatment machines with the patient in the treatment position and then use registration techniques to automatically or manually align and shift the patient to the planned treatment position. This chapter discusses the use of the Tomotherapy Hi-Art® machine, which delivers Helical Tomotherapy Intensity Modulated Radiation Therapy (IMRT) and uses built-in megavoltage computerized tomography (MVCT) for Image-Guided Radiation Therapy (IGRT).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 249.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  • Baisden JM, Romney DA, Reish AG, Cai J, Sheng K, Jones DR, Benedict SH, Read PW, Larner JM (2007) Dose as a function of lung volume and planned treatment volume in helical tomotherapy intensity-modulated radiation therapy-based stereotactic body radiation therapy for small lung tumors. Int J Radiat Oncol Biol Phys 68(4):1229–1237

    Article  PubMed  Google Scholar 

  • Bortfeld T, Jiang SB, Rietzel E (2004) Effects of motion on the total dose distribution. Semin Radiat Oncol 14(1):41–51

    Article  PubMed  Google Scholar 

  • Bortfeld T, Jokivarsi K, Goitein M, Kung J, Jiang SB (2002) Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. Phys Med Biol 47(13):2203–2220

    Article  PubMed  Google Scholar 

  • Boswell S, Tome W, Jeraj R, Jaradat H, Mackie TR (2006) Automatic registration of megavoltage to kilovoltage CT images in helical tomotherapy: an evaluation of the setup verification process for the special case of a rigid head phantom. Med Phys 33(11):4395–4404

    Article  PubMed  Google Scholar 

  • Chen Q, Chen M, Lu W (2011a) Ultrafast convolution/superposition using tabulated and exponential kernels on GPU. Med Phys 38(3):1150–1161

    Article  PubMed  Google Scholar 

  • Chen Q, Lu W, Chen Y, Chen M, Henderson D, Sterpin E (2012) Validation of GPU based tomotherapy dose calculation engine. Med Phys 39(4):1877–1886

    Article  PubMed  Google Scholar 

  • Chen Y, Chen Q, Chen M, Lu W (2011b) Dynamic tomotherapy delivery. Med Phys 38(6):3013–3024

    Article  PubMed  Google Scholar 

  • Dunlap N, McIntosh A, Sheng K, Yang W, Turner B, Shoushtari A, Sheehan J, Jones DR, Lu W, Ruchala K, Olivera G, Parnell D, Larner JL, Benedict SH, Read PW (2010) Helical tomotherapy-based STAT stereotactic body radiation therapy: dosimetric evaluation for a real-time SBRT treatment planning and delivery program. Med Dosim 35(4):312–319

    Article  PubMed  Google Scholar 

  • Grant WH III, Butler EB, Verellen D (2012) Tomotherapy image guided radiation therapy. In: Levitt SH, Purdy JA, Perez CA, Poortmans P (eds) Technical basis of radiation therapy, 5th edn. Springer, Heidelberg

    Google Scholar 

  • Hodge W, Tome WA, Jaradat HA, Orton NP, Khuntia D, Traynor A, Weigel T, Mehta MP (2006) Feasibility report of image guided stereotactic body radiotherapy (IG-SBRT) with tomotherapy for early stage medically inoperable lung cancer using extreme hypofractionation. Acta Oncol 45(7):890–896

    Article  PubMed  Google Scholar 

  • Holmes TW, Hudes R, Dziuba S, Kazi A, Hall M, Dawson D (2008) Stereotactic image-guided intensity modulated radiotherapy using the HI-ART II helical tomotherapy system. Med Dosim 33(2):135–148

    Article  PubMed  Google Scholar 

  • International Commission on Radiation Units and Measurements (1999) Prescribing, recording, and reporting photon beam therapy. Bethesda

    Google Scholar 

  • Jaffray DA (2007) Kilovoltage volumetric imaging in the treatment room. Front Radiat Ther Oncol 40:116–131

    Article  PubMed  CAS  Google Scholar 

  • Kanagaki B, Read PW, Molloy JA, Larner JM, Sheng K (2007) A motion phantom study on helical tomotherapy: the dosimetric impacts of delivery technique and motion. Phys Med Biol 52(1):243–255

    Article  PubMed  Google Scholar 

  • Langen KM, Papanikolaou N, Balog J, Crilly R, Followill D, Goddu SM, Grant W III, Olivera G, Ramsey CR, Shi C (2010) QA for helical tomotherapy: report of the AAPM Task Group 148. Med Phys 37(9):4817–4853

    Article  PubMed  Google Scholar 

  • Mackie TR, Balog J, Ruchala K, Shepard D, Aldridge S, Fitchard E, Reckwerdt P, Olivera G, McNutt T, Mehta M (1999) Tomotherapy. Semin Radiat Oncol 9(1):108–117

    Article  PubMed  CAS  Google Scholar 

  • Mackie TR, Holmes T, Swerdloff S, Reckwerdt P, Deasy JO, Yang J, Paliwal B, Kinsella T (1993) Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. Med Phys 20(6):1709–1719

    Article  PubMed  CAS  Google Scholar 

  • Mahan SL, Ramsey CR, Scaperoth DD, Chase DJ, Byrne TE (2005) Evaluation of image-guided helical tomotherapy for the retreatment of spinal metastasis. Int J Radiat Oncol Biol Phys 63(5):1576–1583

    Article  PubMed  Google Scholar 

  • Meeks SL, Harmon JF Jr, Langen KM, Willoughby TR, Wagner TH, Kupelian PA (2005) Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit. Med Phys 32(8):2673–2681

    Article  PubMed  Google Scholar 

  • Ruchala KJ, Olivera GH, Kapatoes JM, Reckwerdt PJ, Mackie TR (2002) Methods for improving limited field-of-view radiotherapy reconstructions using imperfect a priori images. Med Phys 29(11):2590–2605

    Article  PubMed  Google Scholar 

  • Shah AP, Langen KM, Ruchala KJ, Cox A, Kupelian PA, Meeks SL (2008) Patient dose from megavoltage computed tomography imaging. Int J Radiat Oncol Biol Phys 70(5):1579–1587

    Article  PubMed  Google Scholar 

  • Soisson ET, Hardcastle N, Tome WA (2010) Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy. J Neurooncol 98(2):277–285

    Article  PubMed  Google Scholar 

  • Soisson ET, Tome WA, Richards GM, Mehta MP (2006) Comparison of linac based fractionated stereotactic radiotherapy and tomotherapy treatment plans for skull-base tumors. Radiother Oncol 78(3):313–321

    Article  PubMed  Google Scholar 

  • Sterzing F, Uhl M, Hauswald H, Schubert K, Sroka-Perez G, Chen Y, Lu W, Mackie R, Debus J, Herfarth K, Oliveira G (2010) Dynamic jaws and dynamic couch in helical tomotherapy. Int J Radiat Oncol Biol Phys 76(4):1266–1273

    Article  PubMed  Google Scholar 

  • Welsh JS, Patel RR, Ritter MA, Harari PM, Mackie TR, Mehta MP (2002) Helical tomotherapy: an innovative technology and approach to radiation therapy. Technol Cancer Res Treat 1(4):311–316

    PubMed  Google Scholar 

  • Woodford C, Yartsev S, Van Dyk J (2007) Optimization of megavoltage CT scan registration settings for thoracic cases on helical tomotherapy. Phys Med Biol 52(15):N345–N354

    Article  PubMed  Google Scholar 

  • Xu SP, Xie CB, Ju ZJ, Dai XK, Gong HS, Guo YY, Wang LY (2009) Measurement and analysis of the imaging dose with megavoltage computed tomography for helical tomotherapy. Ai Zheng 28(8):886–889

    Article  PubMed  Google Scholar 

  • Zhou J, Uhl B, Dewitt K, Young M, Taylor B, Fei DY, Lo YC (2010) Image-guided stereotactic body radiotherapy for lung tumors using BodyLoc with tomotherapy: clinical implementation and set-up accuracy. Med Dosim 35(1):12–18

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Walter H. Grant III .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Warren, W., Grant III, W.H., Teh, B.S. (2012). Helical TomoTherapy System. In: Lo, S., Teh, B., Lu, J., Schefter, T. (eds) Stereotactic Body Radiation Therapy. Medical Radiology(). Springer, Berlin, Heidelberg. https://doi.org/10.1007/174_2012_705

Download citation

  • DOI: https://doi.org/10.1007/174_2012_705

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-25604-2

  • Online ISBN: 978-3-642-25605-9

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics