Abstract
Engineering design of orthopedic joint replacements is a complex, interdisciplinary, process that requires a substantial base of knowledge in sciences associated with both orthopedics and design of moving mechanical elements (Machine Design). It is essential therefore to understand, to some degree, certain fundamental scientific concepts in order to understand the design rationale associated with joint replacements. Further it is important to understand the design process itself if one is to understand this rationale.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
American Academy of Orthopaedic Surgeons, Committee on Biomedical Engineering (1992) The patella in TKR - biomedical considerations. Scientific Exhibit, 59th Ann Meeting of the AAOS, Washington D.C.
Bartel DL, Bicknell VL, Wright TM (1986) The effect of conformity, thickness and material on stresses in ultra-high molecular weight polyethylene components for total joint re-placement. J Bone Joint Surg 68A: 1041ā1051
Buechel FF, Pappas MJ, Makris G (1991) Evaluation of contact stress in metal-backed patellar replacements: A predictor of survivorship. Clin Orthop Rel Res 273: 190ā197
Dowson et al. (1985). ACS Symp Ser 287: 171ā187
Hostalen GUR (1982) Hoechst Aktiengesellschaft, Verkauf Kunststoffe, 6230 Frankfurt am Main 80: 22.
Ishinishi T, Ogata K, Nishino I (1990) Comparison of Asian and Caucasian normal and osteoarthritic knees. Trans ORS 562ā563
Morrison JB (1970) The mechanics of the knee joint in relation to normal walking. J Biomech 3: 51ā61
Nakagawa S, Kadoya Y, Todo S et al. (2000) Tibifemoral Movement 3: Full Flexion in the Living Knee Studied by MRI. J Bone Joint Surg 82B: 1199ā1203
Pappas MJ, Makris G, Buechel FF (1986) Contact stresses in metal-plastic total knee replacements: A theoretical and experimental study. Biomed Engin Tech Report
Pappas MJ, Makris G, Buechel FF (1992) Wear in prosthetic knee joints. Scientific Exhibit, 59th Ann Meeting of the AAOS, Washington D.C.
Postac PD, Matejczyk MB, Greenwald AS (1989) Stability characteristics of total knee replacements. Scientific Exhibit, 56th Ann Meeting of the AAOS, Washington D.C.
Rabinowiez E (1965) Friction and wear of materials. Wiley, New York
Renstrom P, Johnson RL (1990) Anatomy and biomechanics of the menisci. Clin Sports Med 9: 523ā528
Seely FB, Smith JO (1958) Advanced mechanics of materials. Wiley, New York
Smidt GL (1973) Biomechanical analysis of the knee. J Bio-mechanics 6: 79ā102
Stulberg SD, Stulberg BN, Hamati Y et al. (1988) Failure mechanisms of metal-backed patellar components. Clin Orthop Rel Research 236: 88ā105
Townsend MA, Izak M, Jackson RW (1977) Total knee motion goniometry. J Biomech 10: 183ā193
Tria AJ, Klein KS, Li RZ (1992) Biomechanics. In: Bowman- Schulman E (ed) An illustrate guide to the knee. Churchill Livingstone, New York, pp 31ā39
Willert HG, Semlitsh M (1977) Reaction of the articular capsule to wear products of artificial joint prosthesis. J Biomed Mat Res 11: 134ā164
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
Ā© 2002 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Pappas, M.J. (2002). Engineering Design of the LCS Knee Replacement. In: Hamelynck, K.J., Stiehl, J.B. (eds) LCSĀ® Mobile Bearing Knee Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-59347-5_6
Download citation
DOI: https://doi.org/10.1007/978-3-642-59347-5_6
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-63944-9
Online ISBN: 978-3-642-59347-5
eBook Packages: Springer Book Archive