Abstract
The paper addresses the problems raised by the application of the photo-oculographic technique to the quantification of static orientations of the eye in ophthalmology. Eye orientations are determined from the relative positions of corneal reflex and pupil images. The relationship between the positions of these images and the angular rotations of the eye is studied with an optical model of the anterior chamber of the eye. This model is used to analyse the influence of technical and physiological variables and to evaluate the accuracy of different calibration procedures applicable to clinics.
Similar content being viewed by others
References
Aalto, H., Juhola, M., andPyykko, I. (1989): ‘Visual stimulator using laser beam for eye movement studies,’Med. & Biol. Eng. & Comput.,27, 3, pp. 332–335
Barbur, J. L., Thomson, W. D., andForsyth, P. M. (1987): ‘A new system for the simultaneous measurement of pupil size and two dimensional eye movements,’Clin. Vis. Sci.,2, (2), pp. 131–142
Barry, J. C., Effert, R., andKaupp, A. (1992): ‘Objective measurement of small angles of strabismus in infants and children with photographic reflection pattern evaluation,’Ophthalmol.,99, pp. 320–328.
Brodie, S. E. (1987): ‘Photographic calibration of the Hirschberg test’,Invest. Ophthalmol. Vis. Sci.,28, pp. 736–742
Bronson, G. W. (1983): ‘Potential sources of error when applying a corneal reflex eye-monitoring technique to infant subjects,’Behav. Methods & Instrum,15, (1), pp. 22–28
Buquet, C., Charlier, J. R., andParis, V. (1988): ‘Museum application of an eye tracker,’Med. & Biol. Eng. & Comput.,26, pp. 277–281.
Buquet, C., Charlier, J. R., Toucas, S., andQuere, M. A. (1989a): ‘Comparaison des techniques d’électro-oculographie et de traitement d’images pour l’enregistrement des mouvements oculaires en clinique ophtalmologique,’Innov. Techn. Biol. Med.,10, (5), pp. 542–552
Buquet, C. (1989b): ‘Nouvelle méthode d’évaluation clinique de la statique et de la cinétique oculaire: la photo-oculographie,’ Doctorate thesis, University of Lille
Charlier, J. R., andHache, J. C. (1982): ‘New instrument for monitoring eye fixation and pupil size during the visual field examination,’Med. & Biol. Eng. & Comput.,2, pp. 23–28
Charlier, J. R., Bariseau, J. L., Chuffart, V., Marsy, F., andHache, J. C. (1985): ‘Real time pattern recognition and feature analysis from video signals applied to eye movement and pupillary reflex monitoring,’Doc. Ophthalmol. Proc. Series,42, pp. 181–189.
Charlier, J. R., andParis, V. (1987): ‘Model for the determination of the gaze direction from images of the eye,’ Proc. European Conf. on Eye Movements, Gottingen,1, pp. 9–10
Cochet, P., Marechal-Courtois, C., andPrijot, E. (1976): ‘Les verres de contact,’Bull. Soc. Belge Ophthalmol.,145, pp. 13–52
Crane, H. D., andSteele, C. M. (1978): ‘Accurate three-dimensional eyetracker,’Appl. Opt.,175, (5), pp. 691–705
Delmarcelle, Y., Francois, J., Goes, F., Collignon-Brach, J., Luyckx-Bacus, J., andVerbraecken, H. (1976): ‘Biométrie oculaire clinique,’ (Masson, Paris)
Donders, F. C. (1864): ‘On the anomalies of accommodation and refraction of the eye’ (The New Sydenham Society, London) (Translated byMoore, W. D.)
Fourcy, J., Pernier, J., Bez, M., andJeannerod, M. (1980): ‘Cyclope: un capteur de position due globe oculaire non contraignant à base de techniques vidéo et microprocesseur,’Innov. Technol. Biol. Med.,1, pp. 44–373
Franceschetti, A. T., andBurian, H. M. (1970): ‘Proximal convergence. An evaluation by comparison of major amblyoscope and alternate prism and cover test measurement and by AC/A ratio determination,’ Strabismus 69 Trans., Consilium Europaeum Strabismi Studio Deditum Congress, Mosby, St Louis, p. 125
Gauthier, G. M., andVolle, M. (1975): ‘Two dimensional eye movement monitor for clinical and laboratory recordings,’EEG Clin. Neurophysiol.,39, pp. 285–291
Hirschberg, J. (1885): ‘Uber die Messung des Schieldgrades und die Dosierung der Schieloperation,’Zentrabl. Prakt. Augenheild.,8, p. 325
Jantti, V., Aantaa, E., Lang, H., Lahti, J., andVirtanen, J. (1979): ‘Microcomputer-controlled visual stimulator for studies of eye movements and visual evoked potentials,’Med. & Biol. Eng. & Comput.,17, pp. 881–882
Marg, E. (1951): ‘Development of electro-oculography—standing potential of the eye in registration of eye movement,’AMA Arch. Ophthalmol.,45, pp. 169
Merchant, J., Morissette, R., andPortefield, J. L. (1974): ‘Remote measurement of eye direction allowing subject motion over one cubic foot of space,’IEEE Trans.,BME-21, pp. 309–317
Quere, M. A., Frettay, C., Le Borgne, R., Delplace, M. P., andDevlamynck, S. (1972): ‘L’exploration multiparamétrique de la cinétique oculaire,’Ann. d’Oculist. (Paris),205, pp. 1307–1320.
Quere, M. A., Devlaminck, S., Delplace, M. P., andLe Borgne, R. (1973): ‘La répartition physiologique des potentiels électro-oculographiques: le champ périoculaire: préliminaires,’Rev. Oto. Neuro. Ophthalmol.,34-2, pp. 135–138
Quere, M. A., Toucas, S., Buquet, C., Charlier, J. R., Lavenant, F., andPechereau, A. (1990a): ‘Photo-oculographie différentielle des mouvements verticaux et obliques,’Ophthalmologie,4, pp. 109–115
Quere, M. A., Toucas, S., Buquet, C., andCharlier, J. R. (1990b): ‘La cinétique des insuffisances de convergence. Etude électro-oculographique et photo-oculographique,’Bull. Soc. Ophalmol. Fr.,11, pp: 1079–1087
Quere, M. A., Toucas, S., Buquet, C., andCharlier, J. R. (1990c): ‘Analyse des mouvements de vergence par photo-oculographie différentielle,’Ophtalmologie,4, pp. 270–274
Reinecke, R. D. (1961a): ‘Selected studies with electro-oculograms I-Report of disjunctive eye movements recorded on electro-oculograms,’Arch. Ophthalmol.,66, pp. 125–129
Reinecke, R. D. (1961b): ‘Selected studies with electro-oculograms II-Subjective evaluation of ocular proprioception monitored with the use of electro-oculograms,’Ibid.,66, pp. 130–132
Reulen, J. P. H., Marcus, J. T., Koops, D., Devries, F. R., Tiesinga, G., andBoshuizen, K. (1988): ‘Precise recording of eye movements: the iris technique,’Med. & Biol. Eng. & Comput.,26, pp. 20–32
Robinson, D. A. (1963): ‘A method of measuring eye movements using a search coil technique in a magnetic field,’IEEE Trans.,BME-10, pp. 137–145
Smith, W. M., andWarter, P. J. (1960): ‘Eye movement and stimulus movement: new photoelectric electromechanical system for recording and measuring tracking motions of the eye,’J. Opt. Soc. Am.,50, pp. 245
Torok, N., Guillemin, V., andBarthony, J. M. (1951): ‘Photoelectro-nystagmography,’Ann. Oto. Rhinol. Laryngol.,60, p. 917.
Weekers, R., Grieten, J., andLavergne, G. (1961): ‘Etude des dimensions de la chambre antérieure de l’oeil humain. I-Considérations biométriques,’Ophthalmologica (Basel),142, pp. 650–652
Weekers, R., Delmarcelle, Y., Collignon-Brach, C., andLuyckx, J. (1973): ‘Mesure optique de la profondeur de la chambre antérieure,’Doc. Ophthalmol.,34, pp. 413–434
Young, L. R., andSheena, D. (1975): ‘Survey of eye movement recording methods,’Behav. Res. Methods & Instrum.,7, pp. 397–429
Zao, Z. Z., Gerbin, J., andRemond, A. (1952): ‘Le champ électrique de l’oeil,’Sem. Hôp. Paris,28, pp. 1506–1513
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Buquet, C., Charlier, J.R. Quantitative assessment of the static properties of the oculo-motor system by the photo-oculographic technique. Med. Biol. Eng. Comput. 32, 197–204 (1994). https://doi.org/10.1007/BF02518918
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02518918