Skip to main content
Log in

Quantitative assessment of the static properties of the oculo-motor system by the photo-oculographic technique

  • Biomedical Engineering
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The paper addresses the problems raised by the application of the photo-oculographic technique to the quantification of static orientations of the eye in ophthalmology. Eye orientations are determined from the relative positions of corneal reflex and pupil images. The relationship between the positions of these images and the angular rotations of the eye is studied with an optical model of the anterior chamber of the eye. This model is used to analyse the influence of technical and physiological variables and to evaluate the accuracy of different calibration procedures applicable to clinics.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Aalto, H., Juhola, M., andPyykko, I. (1989): ‘Visual stimulator using laser beam for eye movement studies,’Med. & Biol. Eng. & Comput.,27, 3, pp. 332–335

    Article  Google Scholar 

  • Barbur, J. L., Thomson, W. D., andForsyth, P. M. (1987): ‘A new system for the simultaneous measurement of pupil size and two dimensional eye movements,’Clin. Vis. Sci.,2, (2), pp. 131–142

    Google Scholar 

  • Barry, J. C., Effert, R., andKaupp, A. (1992): ‘Objective measurement of small angles of strabismus in infants and children with photographic reflection pattern evaluation,’Ophthalmol.,99, pp. 320–328.

    Google Scholar 

  • Brodie, S. E. (1987): ‘Photographic calibration of the Hirschberg test’,Invest. Ophthalmol. Vis. Sci.,28, pp. 736–742

    Google Scholar 

  • Bronson, G. W. (1983): ‘Potential sources of error when applying a corneal reflex eye-monitoring technique to infant subjects,’Behav. Methods & Instrum,15, (1), pp. 22–28

    Google Scholar 

  • Buquet, C., Charlier, J. R., andParis, V. (1988): ‘Museum application of an eye tracker,’Med. & Biol. Eng. & Comput.,26, pp. 277–281.

    Article  Google Scholar 

  • Buquet, C., Charlier, J. R., Toucas, S., andQuere, M. A. (1989a): ‘Comparaison des techniques d’électro-oculographie et de traitement d’images pour l’enregistrement des mouvements oculaires en clinique ophtalmologique,’Innov. Techn. Biol. Med.,10, (5), pp. 542–552

    Google Scholar 

  • Buquet, C. (1989b): ‘Nouvelle méthode d’évaluation clinique de la statique et de la cinétique oculaire: la photo-oculographie,’ Doctorate thesis, University of Lille

  • Charlier, J. R., andHache, J. C. (1982): ‘New instrument for monitoring eye fixation and pupil size during the visual field examination,’Med. & Biol. Eng. & Comput.,2, pp. 23–28

    Article  Google Scholar 

  • Charlier, J. R., Bariseau, J. L., Chuffart, V., Marsy, F., andHache, J. C. (1985): ‘Real time pattern recognition and feature analysis from video signals applied to eye movement and pupillary reflex monitoring,’Doc. Ophthalmol. Proc. Series,42, pp. 181–189.

    Google Scholar 

  • Charlier, J. R., andParis, V. (1987): ‘Model for the determination of the gaze direction from images of the eye,’ Proc. European Conf. on Eye Movements, Gottingen,1, pp. 9–10

    Google Scholar 

  • Cochet, P., Marechal-Courtois, C., andPrijot, E. (1976): ‘Les verres de contact,’Bull. Soc. Belge Ophthalmol.,145, pp. 13–52

    Google Scholar 

  • Crane, H. D., andSteele, C. M. (1978): ‘Accurate three-dimensional eyetracker,’Appl. Opt.,175, (5), pp. 691–705

    Google Scholar 

  • Delmarcelle, Y., Francois, J., Goes, F., Collignon-Brach, J., Luyckx-Bacus, J., andVerbraecken, H. (1976): ‘Biométrie oculaire clinique,’ (Masson, Paris)

    Google Scholar 

  • Donders, F. C. (1864): ‘On the anomalies of accommodation and refraction of the eye’ (The New Sydenham Society, London) (Translated byMoore, W. D.)

  • Fourcy, J., Pernier, J., Bez, M., andJeannerod, M. (1980): ‘Cyclope: un capteur de position due globe oculaire non contraignant à base de techniques vidéo et microprocesseur,’Innov. Technol. Biol. Med.,1, pp. 44–373

    Google Scholar 

  • Franceschetti, A. T., andBurian, H. M. (1970): ‘Proximal convergence. An evaluation by comparison of major amblyoscope and alternate prism and cover test measurement and by AC/A ratio determination,’ Strabismus 69 Trans., Consilium Europaeum Strabismi Studio Deditum Congress, Mosby, St Louis, p. 125

    Google Scholar 

  • Gauthier, G. M., andVolle, M. (1975): ‘Two dimensional eye movement monitor for clinical and laboratory recordings,’EEG Clin. Neurophysiol.,39, pp. 285–291

    Article  Google Scholar 

  • Hirschberg, J. (1885): ‘Uber die Messung des Schieldgrades und die Dosierung der Schieloperation,’Zentrabl. Prakt. Augenheild.,8, p. 325

    Google Scholar 

  • Jantti, V., Aantaa, E., Lang, H., Lahti, J., andVirtanen, J. (1979): ‘Microcomputer-controlled visual stimulator for studies of eye movements and visual evoked potentials,’Med. & Biol. Eng. & Comput.,17, pp. 881–882

    Article  Google Scholar 

  • Marg, E. (1951): ‘Development of electro-oculography—standing potential of the eye in registration of eye movement,’AMA Arch. Ophthalmol.,45, pp. 169

    Google Scholar 

  • Merchant, J., Morissette, R., andPortefield, J. L. (1974): ‘Remote measurement of eye direction allowing subject motion over one cubic foot of space,’IEEE Trans.,BME-21, pp. 309–317

    Google Scholar 

  • Quere, M. A., Frettay, C., Le Borgne, R., Delplace, M. P., andDevlamynck, S. (1972): ‘L’exploration multiparamétrique de la cinétique oculaire,’Ann. d’Oculist. (Paris),205, pp. 1307–1320.

    Google Scholar 

  • Quere, M. A., Devlaminck, S., Delplace, M. P., andLe Borgne, R. (1973): ‘La répartition physiologique des potentiels électro-oculographiques: le champ périoculaire: préliminaires,’Rev. Oto. Neuro. Ophthalmol.,34-2, pp. 135–138

    Google Scholar 

  • Quere, M. A., Toucas, S., Buquet, C., Charlier, J. R., Lavenant, F., andPechereau, A. (1990a): ‘Photo-oculographie différentielle des mouvements verticaux et obliques,’Ophthalmologie,4, pp. 109–115

    Google Scholar 

  • Quere, M. A., Toucas, S., Buquet, C., andCharlier, J. R. (1990b): ‘La cinétique des insuffisances de convergence. Etude électro-oculographique et photo-oculographique,’Bull. Soc. Ophalmol. Fr.,11, pp: 1079–1087

    Google Scholar 

  • Quere, M. A., Toucas, S., Buquet, C., andCharlier, J. R. (1990c): ‘Analyse des mouvements de vergence par photo-oculographie différentielle,’Ophtalmologie,4, pp. 270–274

    Google Scholar 

  • Reinecke, R. D. (1961a): ‘Selected studies with electro-oculograms I-Report of disjunctive eye movements recorded on electro-oculograms,’Arch. Ophthalmol.,66, pp. 125–129

    Google Scholar 

  • Reinecke, R. D. (1961b): ‘Selected studies with electro-oculograms II-Subjective evaluation of ocular proprioception monitored with the use of electro-oculograms,’Ibid.,66, pp. 130–132

    Google Scholar 

  • Reulen, J. P. H., Marcus, J. T., Koops, D., Devries, F. R., Tiesinga, G., andBoshuizen, K. (1988): ‘Precise recording of eye movements: the iris technique,’Med. & Biol. Eng. & Comput.,26, pp. 20–32

    Article  Google Scholar 

  • Robinson, D. A. (1963): ‘A method of measuring eye movements using a search coil technique in a magnetic field,’IEEE Trans.,BME-10, pp. 137–145

    Google Scholar 

  • Smith, W. M., andWarter, P. J. (1960): ‘Eye movement and stimulus movement: new photoelectric electromechanical system for recording and measuring tracking motions of the eye,’J. Opt. Soc. Am.,50, pp. 245

    Article  Google Scholar 

  • Torok, N., Guillemin, V., andBarthony, J. M. (1951): ‘Photoelectro-nystagmography,’Ann. Oto. Rhinol. Laryngol.,60, p. 917.

    Google Scholar 

  • Weekers, R., Grieten, J., andLavergne, G. (1961): ‘Etude des dimensions de la chambre antérieure de l’oeil humain. I-Considérations biométriques,’Ophthalmologica (Basel),142, pp. 650–652

    Google Scholar 

  • Weekers, R., Delmarcelle, Y., Collignon-Brach, C., andLuyckx, J. (1973): ‘Mesure optique de la profondeur de la chambre antérieure,’Doc. Ophthalmol.,34, pp. 413–434

    Article  Google Scholar 

  • Young, L. R., andSheena, D. (1975): ‘Survey of eye movement recording methods,’Behav. Res. Methods & Instrum.,7, pp. 397–429

    Google Scholar 

  • Zao, Z. Z., Gerbin, J., andRemond, A. (1952): ‘Le champ électrique de l’oeil,’Sem. Hôp. Paris,28, pp. 1506–1513

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Buquet, C., Charlier, J.R. Quantitative assessment of the static properties of the oculo-motor system by the photo-oculographic technique. Med. Biol. Eng. Comput. 32, 197–204 (1994). https://doi.org/10.1007/BF02518918

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02518918

Keywords

Navigation