Skip to main content
Log in

Placement of the pulmonary arterial catheter before anesthesia for cardiac surgery: Safe, intelligent, and appropriate use of invasive hemodynamic monitoring

  • Clinical Controversy
  • Published:
Journal of Clinical Monitoring Aims and scope Submit manuscript

    We’re sorry, something doesn't seem to be working properly.

    Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Abstract

Should one catheterize the pulmonary artery (PA) for cardiac surgery before or after induction of anesthesia? Issues of central importance to this question include (1) the patient’s preexisting hemodynamic abnormalities, (2) cardiovascular effects of anesthetic induction drugs, and (3) hemodynamic stress caused by laryngoscopy, cndotrachcal intubation, and PA catheter insertion. Some clinicians use the PA catheter immediately before anesthetic induction to detect and correct acute abnormalities in preload and ventricular function. This approach has been described as being partially responsible for decreased morbidity and mortality m patients with cardiovascular disease. Hemodynamic instability during induction has been reported with many of the common anesthetic induction agents, especially in patients with poor ventricular function. Since blood pressure is the product of cardiac output and systemic vascular resistance, accurate interpretation and treatment of hypotension are possible only when these variables are provided by vigorous use of the PA catheter. Early detection of myocardial ischemia is possible with examination of acute changes in the pulmonary capillary wedge pressure tracing. However, the lack of such information can restrict even the best anesthetist. Insertion of the PA catheter in the awake patient can be accomplished effectively and with minimal risk, so long as good patient rapport, adequate premedication, and continuation of antiangmal medication until the time of surgery are assured. Preinduction placement of the PA catheter provides valuable, objective information for the cardiac anesthesiologist without incurring significant risk to the patient.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Swan HJC, Ganz W: Hemodynamic measurements in clinical practice: A decade in review. J Am Coll Cardiol 1983;1:103–113

    Article  PubMed  CAS  Google Scholar 

  2. Pace NL: A critique of flow directed pulmonary arterial cathcterization. Anesthesiology 1977;47:455–465

    Article  PubMed  CAS  Google Scholar 

  3. Cunningham JM, Ison OW, Spencer FC: Coronary artery surgery. Adv Surg 1978;12:347–387

    PubMed  Google Scholar 

  4. Moore CH, Lombardo TR, Allums JA, Gordon FT: Left main coronary artery stenosis: Hemodynamic monitoring to reduce mortality. Ann Thorac Surg 1978;26:445–449

    Article  PubMed  CAS  Google Scholar 

  5. Whittemore AD, Clowes AW, Hectman HB, Mannick JA: Aortic aneurysm repair—reduced operative mortality associated with the maintenance of optimal cardiac performance. Ann Surg 1980;192:414–421

    Article  PubMed  CAS  Google Scholar 

  6. Rao TLK, Jacobs KH, El-etr AA: Reinfarction following anesthesia in patients with myocardial infarction. Anesthesiology 1983;59:499–505

    Article  PubMed  CAS  Google Scholar 

  7. Stern PA, Tinker JH, Tarhan S: Myocardial reinfarction after anesthesia and surgery. JAMA 1978;239:2566–2570

    Article  Google Scholar 

  8. Waller JL, Johnson SP, Kaplan JA: Usefulness of pulmonary artery catheters during aortocoronary bypass surgery. Anesth Analg 1982;61:221–222

    Article  Google Scholar 

  9. Louis RM, Del Guercio LRM, Colin JP: Monitoring operative risk in the elderly. JAMA 1980;243:1350–1355

    Article  Google Scholar 

  10. Babu SC, Sharma PVP, Raciti A, Mayr CH, et al: Monifor guided responses. Arch Surg 1980;115:1384–1386

    PubMed  CAS  Google Scholar 

  11. Balasaraswathi K, Kumar P, Rao TKL, El-etr AA: Lett ventricular end-diastolic pressure as an index for nitrous oxide use during coronary artery surgery. Anesthesiology 1981;55:708–709

    PubMed  CAS  Google Scholar 

  12. Dauchot PJ, Staub F, Berzina L, et al: Hemodynamic response to diazepam: Dependence on prior left ventricular end diastolic pressure. Anesthesiology 1984;60:499–503

    Article  PubMed  CAS  Google Scholar 

  13. Colvin MP, Savage JM, Newland PE: Cardiorespiratory changes following induction of anaesthesia with etomidate in patients with cardiac disease. Br J Anaesth 1979;51:551–556

    Article  PubMed  CAS  Google Scholar 

  14. Stanley TH, Webster LR: Anesthetic requirements and cardiovascular effects of fentanyl-oxygen and tentanyldiazepam-oxygen anesthesia in man. Anesth Analg 1978;57:411–416

    Article  PubMed  CAS  Google Scholar 

  15. Sebel PS, Bovil JG: Cardiovascular effecfs of sufentanil anesthesia. Anesthesiology 1981;55:212–217

    Article  Google Scholar 

  16. Waller JL, Hug CC, Nagle DM, Craver JM: Hemodynamic changes during tentanyl-oxygen anesthesia for aortocoronary bypass operation. Anesth Analg 1982;61:115–119

    Article  Google Scholar 

  17. Sonntag H, Larsen R, Hiltiker O. et al: Myocardial blood flow and oxygen consumption during high-dose fentanyl anesthesia in patients with coronary artery disease. Anesthesiology 1982;56:417–422

    Article  PubMed  CAS  Google Scholar 

  18. Lunn JK, Stanley TH, Eisele J, et al: High dose fentanyl anesthesia for coronary artery surgery: Plasma fentanyl concentrations and influence of nitrous oxide on cardiovascular response. Anesth Analg 1979;58:390–395

    Article  PubMed  CAS  Google Scholar 

  19. Slogoff S, Keats AS: Dose perioperative myocardial ischemia lead to postoperative myocardial infarction? Anesthesiology 1985;62:107–114

    Article  PubMed  CAS  Google Scholar 

  20. Barnard RJ, Buckberg GD, Duncan HW: Limitations of the standard transthoracic ECG in detecting subendocardiac ischemia. Am Heart J 1980;99:476–482

    Article  PubMed  CAS  Google Scholar 

  21. Rao TLK: Cardiac monitoring for the noncardiac surgical patient. Semin Anesth 1983;2:241–250

    Google Scholar 

  22. Kaplan JA, Wells PH: Early diagnosis of myocardial ischemia using the PA catheter. Anesth Analg 1981;60:789–793

    PubMed  CAS  Google Scholar 

  23. Lunn JK, Stanley TH, Webster LR, Didwai AV: Arterial blood-pressure and pulse-rate responses to pulmonary and radial arterial cathetcrization prior to cardiac and major vascular operations. Anesthesiology 1979;51:265–269

    Article  PubMed  CAS  Google Scholar 

  24. de Lange SS, Boscoe MJ, Stanley TH: Percutaneous pulmonary artery cathcterization via the arm before anesthesia: Success rate, frequency of complications and arterial pressure and heart rate responses. Br J Anaesth 1981;53:1167–1171

    Article  PubMed  Google Scholar 

  25. Waller JZ, Zaidan JR, Kaplan JA, Bauman DI: Hemodynamic responses to preoperative vascular cannulation in patients with coronary artery disease. Anesthesiology 1982;56:219–221

    Article  PubMed  CAS  Google Scholar 

  26. Quintin L, Whalley DG, Wynands JE, Morin JE: The effects of vascular catheterizations on heart rate and blood pressure before aortocoronary bypass surgery. Can Anaesth Soc J 1981;28:244–247

    Article  PubMed  CAS  Google Scholar 

  27. Waller JL, Zaidan JR, Kaplan JA, Baunian DI: Hemodynamic effects of vascular cannulation by residents. Anesthesiology 1982;53:S114

    Article  Google Scholar 

  28. Mangano DT: Monitoring pulmonary arterial pressure in coronary artery disease. Anesthesiology 1980;53:364–370

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Streisand, J.B., Clark, N.J. & Pace, N.L. Placement of the pulmonary arterial catheter before anesthesia for cardiac surgery: Safe, intelligent, and appropriate use of invasive hemodynamic monitoring. J Clin Monitor Comput 1, 193–197 (1985). https://doi.org/10.1007/BF02832260

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02832260

Key words

Navigation