Skip to main content
Log in

Rapid prototyping fabrication and finite element evaluation of the three-dimensional medical pelvic model

  • Original Article
  • Published:
The International Journal of Advanced Manufacturing Technology Aims and scope Submit manuscript

Abstract

This paper presents a non-uniform, periodic closed B-spline approximation algorithm for the fabrication of a medical pelvic model, based on rapid prototyping, and also gives the finite element evaluation of the pelvic model. Rapid prototyping (RP), when used in fabricating medical prosthesis, has a strict requirement for closeness and impermeability of STL files. Incorrect data structure in STL files will cause the subsequent slicing process not to proceed. The non-uniform periodic closed B-spline curve approximation method was applied to processing CT data. The precision and size of STL files was improved to optimize the RP model of the pelvis. Finally, the model of the pelvis was evaluated with the finite element method. Results suggest that a high similarity has been achieved in terms of shape, size and biomechanical properties of the pelvic model and the normal one, which validates our argument that rapid prototyping with non-uniform, periodic closed B-spline algorithm is suitable for the fabrication of a pelvic model, which will prove to be significant in the design of pelvic prostheses .

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Wirbel RJ, Schulte M, Maier B, Mutschler WE (1999) Megaprosthetic replacement of the pelvis: function in 17 cases. Acta Orthop Scand 70(4):348–352

    Article  Google Scholar 

  2. Bruns J, Luessenhop SL, Dahmen G Sr (1997) Internal hemipelvectomy and endoprosthetic pelvic replacement: long-term follow-up results. Arch Orthop Trauma Surg 116(1–2):27–31

  3. Burri C, Etter C (1985) Partial and complete pelvic replacement in tumor patients. Acta Orthop Belg 51(2–3):212–219

    Google Scholar 

  4. Berry E, Brown JM, Connell M, et al. (1997) Preliminary experience with medical applications of rapid prototyping by selective laser sintering. Med Eng Phys 19(1):90–96

    Article  Google Scholar 

  5. Colin A, Boire JY (1997) A novel tool for rapid prototyping and development of simple 3D medical image processing applications on PCs. Comput Methods Prog Biomed 53(2):87–92

    Article  Google Scholar 

  6. Yan X, Gu P (1996) A review of rapid prototyping technologies and systems. Comput-Aided Des 28(4):307–318

    Google Scholar 

  7. Fischer A (2000) Multi-level models for reverse engineering and rapid prototyping in remote CAD systems. Comput-Aided Des 32:27–38

    Google Scholar 

  8. Chiu WK, Tan ST (2000) Multiple material objects: from CAD representation to data format for rapid prototyping. Comput-Aided Des 32(12):707–717

    Google Scholar 

  9. Szilvi-Nagy, Gy M (2003) Analysis of STL files. Math Comput Model 38:945–960

    Article  Google Scholar 

  10. Park H, Kim K (1996) Smooth surface approximation to serial cross-sections. Comput-Aided Des 28(12):995–1005

    Google Scholar 

  11. Chung KL, Yan WM (1994) A fast algorithm for cubic B-spline curve fitting, Comput Graph 18(3):327–334

    Google Scholar 

  12. Piegl L, Tiller W (1995) Algorithm for degree reduction of B-spline curves. Comput Aided Des 27(2):101–110

    Article  MATH  Google Scholar 

  13. Wang YJ, Wang JL (1989) Orthopaedic biomechanics. People’s Military Medical Publisher, Beijing

  14. Dawson JM, Khmelniker BV, McAndrew MP (1998) Analysis of the structural behavior of the pelvis during lateral impact using the finite element method. Accident Anal Prevention 31:109–119

    Article  Google Scholar 

  15. Dalstra M, Huiskes R (1995) Load transfer across the pelvic bone. J Biomech 28(6):715–724

    Article  Google Scholar 

  16. Finlay JB, Boume RB, Landsberg PD, et al. (1986) Pelvic stress in vitro. J Biomech 19:703–714

    Article  Google Scholar 

  17. Dalstra M, Huiskes R (1995) Development and validation three-dimensional finite element model of the pelvic bone . J Biomech Eng 117(8):272–278

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ying Tie.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tie, Y., Ma, R., Ye, M. et al. Rapid prototyping fabrication and finite element evaluation of the three-dimensional medical pelvic model. Int J Adv Manuf Technol 28, 302–306 (2006). https://doi.org/10.1007/s00170-004-2377-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00170-004-2377-z

Keywords

Navigation