Skip to main content

Advertisement

Log in

Diarthrodial joint contact models: finite element model development of the human hip

  • Original Article
  • Published:
Engineering with Computers Aims and scope Submit manuscript

Abstract

The demands associated with modeling geometrically complex anatomic structures often limit the utility of musculoskeletal finite element (FE) analyses. Automated meshing routines typically rely on the use of tetrahedral elements. Hexahedral elements, however, often outperform tetrahedral elements, namely during contact analyses. Hence, a need exists for a preprocessor geared towards automated hexahedral meshing of biologic structures. Two meshing schemes for finite element mesh development of the human hip are presented: (1) a projection method, coupled with a surface smoothing algorithm, has been applied to accommodate the near spherical nature of the femoral head articular cartilage surface, while (2) a technique termed the preferential method was developed to mesh the acetabulum. The latter technique benefits from a user traced bound of the articular surface. High-quality, three-dimensional continuum models, consisting solely of hexahedral elements, were generated for the femoral head and the acetabulum. To check the validity of the meshing routines, a transient deformable–deformable contact finite element analysis was carried out. Gait cycle kinematics and kinetics from the weight-bearing stance phase were considered. The contact pressure (1.74 MPa) was in agreement with the values reported in the literature.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  1. Keyak JH et al (1990) Automated three-dimensional finite element modeling of bone: a new method. J Biomed Eng 12:389–397

    Article  Google Scholar 

  2. Viceconti M et al (1998) A comparative study on different methods of automatic mesh generation of human femurs. Med Eng Phys 20(1):1–10

    Article  Google Scholar 

  3. Donahue TL, Hull ML, Rashid MM, Jacobs CR (2002) A finite element model of the human knee joint for the study of tibio-femoral contact. J Biomech Engineering 124(3):273–280

    Article  Google Scholar 

  4. Grosland NM, Brown TD (2002) A voxel-based formulation for contact finite element analysis. Comput Methods Biomech Biomed Eng 5(1):21–32

    Article  Google Scholar 

  5. Anderson DD et al (2006) Intra-articular contact stress distributions at the ankle throughout stance phase––patient-specific finite element model analysis as a metric of degeneration propensity. Biomech Model Mechanobiol 5:82–89

    Article  Google Scholar 

  6. Andreasen NC et al (1993) Voxel processing techniques for the antemortem study of neuranatomy and neuropathology using magnetic resonance imaging. J Neuropsychiatry Clin Neurosci 5:121–130

    Google Scholar 

  7. Andreasen NC et al (1992) Image processing for the study of brain structure and function: problems and programs. J Neuropsychiatry Clin Neurosci 4(2):125–133

    Google Scholar 

  8. Wyvill G, McPheeters C, Wyvill B (1986) Data structure for soft objects. Visual Comput 2:227:234

    Article  Google Scholar 

  9. Shepherd DET, Seedhom BB (1999) Thickness of human articular cartilage in joints of the lower limb. Ann Rheum Dis 58:27–34

    Article  Google Scholar 

  10. Mow VC, Hayes WC (1991) Basic orthopaedic biomechanics. Raven Press, New York

    Google Scholar 

  11. Maxian TA, Brown TD, Weinstein SL (1995) Chronic stress tolerance levels for human articular cartilage: two nonuniform contact models applied to long-term follow-up of CDH. J Biomech 28(2):159–166

    Article  Google Scholar 

  12. Pedersen DR, Brand RA, Davy DT (1997) Pelvic muscle and acetabular contact forces during gait. J Biomech 30(9):959–965

    Article  Google Scholar 

  13. Greenwald AS, O'Connor JJ (1971) The transmission of load through the human hip joint. J Biomech 4(6):507–528

    Article  Google Scholar 

Download references

Acknowledgments

Financial support from the Whitaker Foundation, National Institutes of Health (Award EB001501), and the Colleges of Medicine and Engineering at the University of Iowa is gratefully acknowledged. The authors would also like to thank Dr. Vincent Magnotta and Dr. Thomas Brown.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. M. Grosland.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Shivanna, K.H., Grosland, N.M., Russell, M.E. et al. Diarthrodial joint contact models: finite element model development of the human hip. Engineering with Computers 24, 155–163 (2008). https://doi.org/10.1007/s00366-007-0083-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00366-007-0083-9

Keywords

Navigation