Skip to main content

Implantable Hearing Devices for Conductive and Sensorineural Hearing Impairment

  • Chapter
  • First Online:
Auditory Prostheses

Part of the book series: Springer Handbook of Auditory Research ((SHAR,volume 39))

Abstract

Some degree of hearing loss affects 10 to 15% of the general population. The prevalence increases with age. More than one third of 70-year-old persons have hearing loss in excess of 30 dB HL (Hearing Loss), which makes them eligible for hearing aids. Although introduction of digital signal processing in acoustic hearing aids in the late 1990s has led to wider acceptance, owing to improved sound quality and comfort, only 20 to 25% of hearing impaired subjects are satisfied with their hearing aids. There are several medical and technological limitations that are responsible for this low acceptance rate of the acoustic hearing aids. The medical conditions limiting the use of acoustic hearing aids include chronic external otitis, chronic middle ear disease, or presence of profound hearing loss. The technological limitations are often related to the use of ear molds in these aids, including occlusion of the ear canal, leading to complaints about the user’s own voice, annoying feedback as a result of high amplification and acoustic leakage, and undesirable blockage of residual hearing at low frequencies. A final reason for the low acceptance rate of acoustic hearing aids is social stigma associated with being perceived old or handicapped.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Abbass, H. A., Kane, M., Gaverick, S., Falk, T. J., Frenz, W., Ko, W. H., & Maniglia, A. J. (1997). Mechanical, acoustical and electromagnetic evaluation of the semi-implantable middle ear hearing device. Ear Nose & Throat Journal 76, 321–327.

    CAS  Google Scholar 

  • Arunachalam, P. S., Kilby, D., Meikle, D., Davison, T., & Johnson, I. J. (2001). Bone anchored hearing aid quality of life assessed by Glasgow Benefit. Laryngoscope 111, 1260–1263.

    Article  PubMed  CAS  Google Scholar 

  • Baguley, D. M., & Plydoropulou, V. (2009). Prevost AT Bone-anchored hearing aids for single-sided deafness. Clinical Otolaryngology, 34, 176–177.

    Article  PubMed  CAS  Google Scholar 

  • Ball, G. R., Huber, A., & Goode, R. L. (1997). Scanning laser Doppler Vibrometry of the middle ear ossicles. Ear Nose & Throat Journal, 76, 213–218.

    CAS  Google Scholar 

  • Barbara, M., Manni, V., & Monini, S. (2009). Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: preliminary experience with the Esteem, Envoy. Acta Oto-Laryngologica, 129, 429–432.

    Article  PubMed  Google Scholar 

  • Beltrame, A. M., Martini, A., Prosser, S., Giarbini, N., & Streitberger, C. (2009). Coupling the Vibrant Soundbridge to cochlea round window: auditory results in patients with mixed hearing loss. Otology & Neurotology 30, 194–201.

    Article  Google Scholar 

  • Bosman, A. J., Snik, A. F. M., Mylanus, E. A. M., & Cremers, C. W. R. J. (2009). Fitting of the Baha Intenso. International Journal of Audiology, 48, 346–352.

    Article  PubMed  Google Scholar 

  • Browning, G. G. (1990). The British experience of an implantable, subcutaneous bone conduction hearing aid. Journal of Laryngology and Otology, 104, 534–538.

    PubMed  CAS  Google Scholar 

  • Bruschini, L., Foru, F, Santoro, A., Bruschini, P., & Berrettini, S. (2009). Fully implantable Otologics MET Carina device for the treatment of sensorineural hearing loss. Preliminary results. Acta Otorhinolaryngologica Italica, 29, 79–85.

    PubMed  CAS  Google Scholar 

  • Carlsson, P. U., & HÃ¥kansson, B. E. (1997). The bone-anchored hearing aid: reference quantities and functional gain. Ear and Hearing 18, 34–41.

    Article  PubMed  CAS  Google Scholar 

  • Cayé-Thomasen, P., Jensen, J. H., Bonding, P., & Tos, M. (2002). Long-term results and experience with the first generation semi-implantable electromagnetic with ossicular replacement device for mixed hearing loss. Otology & Neurotology, 23, 904–911.

    Article  Google Scholar 

  • Chen, D. A., Backous, D. D., Arriaga, M. A., Garvin, R., Kobylek, D., Littman, T., Walgren, S., & Luca, D. (2004). Phase 1 clinical trial results of the Envoy System: a totally implantable middle ear device for sensorineural hearing loss. Otolaryngology-Head and Neck Surgery, 131, 904–916.

    Article  PubMed  Google Scholar 

  • Colletti, V., Soli, S. D., Carner, M., & Colletti, L. (2006). Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window. International Journal of Audiology, 45, 600–608.

    Article  PubMed  Google Scholar 

  • Colletti, V., Carner, M., & Colletti, L. (2009). TORP vs round window implant for hearing restoration of patients with extensive ossicular chain defect. Acta Oto-Laryngologica, 129, 449–452.

    Article  PubMed  CAS  Google Scholar 

  • Cremers, C. W. R. J., & Snik, A. F. M. (2005). The endaural approach for the Vibrant Soundbridge middle ear implant. Journal of the Dutch ENT Society, 11, 104.

    Google Scholar 

  • Cremers, C. W. R. J., Snik, A. F. M., & Beynon, A. J. (1992). Hearing with the bone-anchored hearing aid (Baha HC 2000) compared to a conventional bone-conduction hearing aid. Clinical Otolaryngology, 17, 275–279.

    Article  PubMed  CAS  Google Scholar 

  • Cremers, C. W. R. J., Verhaegen, V. J., & Snik, A. F. M. (2008). The floating mass transducer of the Vibrant Soundbridge interposed between the stapes and tympanic membrane after incus necrosis. Otology & Neurotology, 30, 76–78.

    Article  Google Scholar 

  • Cude, D., Murri, A., & Tinelli, N. (2009). Piezoelectric round window osteoplasty for Vibrant Soundbridge Implant. Otology & Neurotology 30, 782–786.

    Article  Google Scholar 

  • Declau, F., Cremers, C. W. R. J., & Van de Heyning, P. (1999). Diagnosis and management strategies in congenital atresia of the external auditory canal. Study Group on Otological Malformations and Hearing Impairment. British Journal of Audiology, 33, 313–327.

    Article  PubMed  CAS  Google Scholar 

  • Dillon, H. (2001). Hearing Aids. New York: Thieme Verlag.

    Google Scholar 

  • Dutt, S. N., McDermott, A. L., Jelbert, A., Reid, A. P., & Proops, D. W. (2002). The Glasgow Benefit Inventory in the evaluation of patient satisfaction with the bone anchored hearing aid: quality of life issues. Journal of Laryngology and Otology Supplement, 28, 7–14.

    Google Scholar 

  • Eeg-Olofsson, M., Stenfelt, S., Tjellström, A., & Granström, G. (2008). Transmission of bone-conducted sound in the human skull measured by cochlear vibrations. International Journal of Audiology, 47, 761–769.

    Article  PubMed  Google Scholar 

  • Fraysse, B., Lavieille, J. P., Schmerber, S., Enée, V., Truy, E., Vincent, C., Vaneecloo, F. M., & Sterkers, O. (2001). A multicenter study of the Vibrant Soundbridge middle ear implant: early clinical results and experience. Otology & Neurotology, 22, 952–961.

    Article  CAS  Google Scholar 

  • Fredrickson, J. M., Coticchia, J. M., & Khosla, S. (1995). Ongoing investigations into an implantable electromagnetic hearing aid for moderate to severe sensorineural hearing loss. Otolaryngologic Clinics of North America, 28, 107–120.

    PubMed  CAS  Google Scholar 

  • Frenzel, H., Hanke, F., Beltrame, M., Steffen, A., Schonweiler, R., & Wollenberg, B. (2009). Application of the Vibrant Soundbridge to unilateral osseus atresia cases. Laryngoscope, 119, 67–73.

    Article  PubMed  Google Scholar 

  • Gan, R. Z., Wood, M. W., Ball, G. R., Dietz, T. G., & Dormer, K. J. (1997). Implantable hearing device performance measured by laser Doppler interferometry. Ear Nose and Throat Journal, 76(5), 297–309.

    CAS  Google Scholar 

  • Gatehouse, S., & Browning, G. G. (1990). The output characteristics of an implanted bone-­conduction prosthesis. Clinical Otolaryngology, 15, 503–513.

    Article  PubMed  CAS  Google Scholar 

  • Gyo, K., Saiki, T. & Yanagihara, N. (1996). Implantable hearing aids using a piezoelectric ossicular vibrator: a speech audiometric study. Audiology, 35, 271–276.

    Article  PubMed  CAS  Google Scholar 

  • HÃ¥kansson, B., Tjellström, A., Rosenhall, U., & Carlsson, P. (1985). The bone-anchored hearing aid: principles design and a psycho-acoustical evaluation. Acta Oto-Laryngologica, 100, 229–239.

    Article  PubMed  Google Scholar 

  • HÃ¥kansson, B., Tjellström, A., & Carlsson, P. (1990). Percutaneous versus transcutaneous transducers for hearing by direct bone conduction. Otolaryngology-Head and Neck Surgery, 102, 339–344.

    PubMed  Google Scholar 

  • HÃ¥kansson, B., Eeg-Olofsson, M., Reinfeldt, S., Stenfelt, S., & Granström, G. (2008). Percutaneous versus transcutaneous bone conduction implant system: a feasibility study on a cadaver head. Otology & Neurotology, 29, 1132–1139.

    Article  Google Scholar 

  • Hausler, R., Stieger, C., Bernhard, H., & Kompis, M. (2008). A novel implantable hearing system with direct acoustic cochlear stimulation. Audiology & Neurotology, 13, 247–256.

    Article  Google Scholar 

  • Heide, J., Tatge, G., Sander, T., Gooch, T., & Prescott, T. (1988). Development of a semi-­implantable hearing device. Advances in Audiology, 4, 32–43.

    Google Scholar 

  • Hough, J. V., Vernon, J., Johson, B., Dormer, K., & Himelick, M. A. (1986). Experiences with implantable hearing devices and a presentation of a new device. Annals of Otology, Rhinology, and Laryngology 95, 60–65.

    PubMed  CAS  Google Scholar 

  • Hough, J. V., Wilson, N., Dormer, K. J., & Rohrer, M. (1994). The Audiant bone conductor: update of patient results in North America. American Journal of Otology, 15, 189–197.

    PubMed  CAS  Google Scholar 

  • Hough, J. V., Dyer, R. K., Matthews, P., & Wood, M. W. (2001). Early clinical results: SOUNDTEC implantable hearing device phase II study. Laryngoscope 111, 1–8.

    Article  PubMed  CAS  Google Scholar 

  • Hough, J. V., Matthews, P., Wood, M. W., & Dyer, R. K. (2002). Middle ear electromagnetic semi-implantable hearing device: results of the phase II SOUNDTEC direct system clinical trial. Otology & Neurotology, 23, 895–903.

    Article  CAS  Google Scholar 

  • Huber, A. M., Ball, G. R., Veraguth, D., Dillier, N., Bodmer, D., & Sequeira, D. (2006). A new implantable middle ear hearing device for mixed hearing loss: A feasibility study in human temporal bones. Otology & Neurotology, 27, 1104–1109.

    Article  Google Scholar 

  • Hüttenbrink, K. B., Zahnert, T., Bornitz, M., & Beutner, D. (2008). TORP-vibroplasty: a new alternative for the chronically disabled middle ear. Otology & Neurotology 29, 965–971.

    Article  Google Scholar 

  • Jenkins, H. A., Niparko, J. K., Slattery, W. H., & Neely, J. G., Fredrickson, J. M. (2004). Otologics Middle Ear Transducer Ossicular Stimulator: performance results with varying degrees of sensorineural hearing loss. Acta Oto-Laryngologica, 124, 391–394.

    Article  PubMed  Google Scholar 

  • Jenkins, H. A., Atkins, J. S., Horlbeck, D., Hoffer, M. E., Balough, B., Arigo, J. V., Alxiades, G., & Garvis, W. (2007a). Phase I preliminary results of use of the Otologics MET Fully-Implantable Ossicular Stimulator. Otolaryngology–Head and Neck Surgery, 137, 206–212.

    Article  PubMed  Google Scholar 

  • Jenkins, H. A., Pergola, N., & Kasic, J. (2007b). Anatomical vibrations that implantable microphones must overcome. Otology & Neurotolology, 28, 579–588.

    Google Scholar 

  • Jenkins, H. A., Pergola, N., & Kasic, J. (2007c). Intraoperative ossicular loading with the Otologics fully implantable hearing device. Acta Oto-Laryngologica, 127, 360–364.

    Article  PubMed  Google Scholar 

  • Johnson, C., Danhauer, J. L., Reith, A. C., & Latiolais, L. N. (2006). A systematic review of the nonacoustic benefits of bone-anchored hearing aids. Ear and Hearing, 27, 703–713.

    Article  PubMed  Google Scholar 

  • Kartush, J. M., & Tos, M. (1995). Electromagnetic ossicular augmentation device. Otolaryngologic Clinics of North America, 28, 155–172.

    PubMed  CAS  Google Scholar 

  • Kasic, J. F., & Fredrickson, J. M. (2001). The Otologics MET Ossicular Stimulator. Otolaryngologic Clinics of North America, 34, 501–514.

    Article  PubMed  CAS  Google Scholar 

  • Ko, W. H., & Zhu, W. L. (1995). Engineering principles of mechanical stimulation of the middle ear. Otolaryngologic Clinics of North America 28, 29–42.

    PubMed  CAS  Google Scholar 

  • Lefebvre, P. P., DeCat, M., Cremers, C. W. R. J., Snik, A. F. M., & Maier, H. (2006). Otologics fully implantable hearing device results. Wiener Medizinische Wochenschrift 156(Suppl. 119), 84.

    Google Scholar 

  • Lefebvre, P. P., Martin, C., Dubreuil, C., Decat, M., Yazbeck, A., Kasic, J., & Tringali, S. (2009). A pilot study of the safety and performance of the Otologics fully implantable hearing device: transducing sounds via the round window membrane to the inner ear. Audiology & Neurotology, 14, 172–180.

    Article  CAS  Google Scholar 

  • Lenarz, T., Weber, B. P., Issing, P. R., Gnadeberg, D., Ambjørnsen, K., Mack, K. F., & Winter, M. (2001). Vibrant Sound Bridge System. A new kind hearing prosthesis for patients with sensorineural hearing loss. 2. Audiological results. Laryngorhinootologie, 80, 370–380.

    Article  PubMed  CAS  Google Scholar 

  • Leysieffer, H., Baumann, J. W., Müller, G., & Zenner, H. P. (1997). Ein implantierbarer piezoelektrischer Hörgerätewandler für Innenohrschwerhörige. Teil II: Klinisches Implantat. Zeitschrift für Hals Nasen und Ohrenheilkunde 45, 801–815.

    CAS  Google Scholar 

  • Linder, T., Schlegel, C., Demin, N., & van der Westhuizen, S. (2008). Active middle ear implants in patients undergoing subtotal petrosectomy: new application for the Vibrant Soundbridge device and its implication for lateral cranium base surgery. Otology & Neurotology, 30, 41–47.

    Article  Google Scholar 

  • Luetje, C., Brackman, D., Balkany, T. J., Maw, J., Baker, R. S., Kelsall, D., Backous, D., Miyamoto, R., Parisier, S., & Arts, A. (2002). Phase III clinical trial results with the Vibrant Soundbridge implantable middle ear hearing device: a prospective controlled multicenter study. Otolaryngology–Head and Neck Surgery, 126, 97–107.

    Article  PubMed  Google Scholar 

  • Magnan, J., Manrique, M., Dillier, N., Snik, A., & Häusler, R. (2005). International consensus on middle ear implants. Acta Oto-Laryngologica, 125, 920–921.

    Article  PubMed  CAS  Google Scholar 

  • Maniglia, A. J., Ko, W. H., Gaverick, S. L., Abbass, H., Kane, M., Rosenbaum, M. L., & Murray, G. (1997). Semi-implantable middle ear electromagnetic hearing device for sensorineural hearing loss. Ear Nose & Throat Journal, 76, 333–341.

    CAS  Google Scholar 

  • Mosnier, I., Sterkers, O., Bouccara, D., Labassi, S., Bebear, J. P., Bordure, P., Dubreuil, C., Dumon, T., Frachet, B., Fraysse, B., Lavielle, J.F., & Magnan, J. (2008). Benefit of the Vibrant Soundbridge device in patients implanted for 5 to 8 years. Ear and Hearing 29, 281–284.

    Article  PubMed  Google Scholar 

  • Ohno, T., & Kajiya, T. (1988). Performance of middle ear implants. Advance in Audiology 4, 85–96.

    Google Scholar 

  • Reinfeldt, S. (2009). Bone-conduction hearing in human communication (Unpublished thesis). Chalmers University of Technology, Göteborg, Sweden.

    Google Scholar 

  • Roland, P. S., Shoup, A. G., Shea, M. C., Jones, D. B., & Richey, H. S. (2001). Verification of improved patient outcomes with a partially implantable hearing aid, the SOUNDTEC direct hearing system. Laryngoscope 111, 1682–1686.

    Article  PubMed  CAS  Google Scholar 

  • Saliba, I., Calmels, M. N., Wanna, G., Iversenc, G., James, C., Deguine, O., & Fraysse, B. (2005). Binaurality in middle ear implant recipients using contralateral digital hearing aids. Otology & Neurotology, 26, 680–685.

    Article  Google Scholar 

  • Silverstein, H., Atkins, J., Thompson, J. H., & Gilman, N. (2005). Experience with the SOUNDTEC implantable hearing aid. Otology & Neurotology 26, 211–217.

    Article  Google Scholar 

  • Schmuziger, N., Schimmann, F., Wengen, D., Patscheke, J., & Probst, R. (2006). Long-term assessment after implantation of the Vibrant Soundbridge device. Otology & Neurotology, 27, 183–188.

    Article  Google Scholar 

  • Siegert, R., Mattheis, S., & Kasic, J. (2007). Fully implantable hearing aids in patients with congenital auricular atresia. Laryngoscope 117, 336–340.

    Article  PubMed  Google Scholar 

  • Snik, A. F. M., & Cremers, C. W. R. J. (2001). Vibrant semi-implantable hearing device with digital sound processing: effective gain and speech perception. Archives of Otolaryngology–Head & Neck Surgery 127, 1433–1437.

    CAS  Google Scholar 

  • Snik, A. F. M., & Cremers, C. W. R. J. (2004). Audiometric evaluation of an attempt to optimize the fixation of the transducer of a middle-ear implant to the ossicular chain with bone cement. Clinical Otolaryngology, 29, 5–9.

    Article  PubMed  CAS  Google Scholar 

  • Snik, A. F. M., Mylanus, E. A. M., & Cremers, C. W. R. J. (1995). Bone-anchored hearing aids in patients with sensorineural hearing aids loss and persistent otitis media. Clinical Otolaryngology, 20, 31–35.

    Article  PubMed  CAS  Google Scholar 

  • Snik, A. F. M., Dreschler, W. A., Tange, R. A., & Cremers, C. W. R. J. (1998). Short and longterm results with implantable transcutaneous and percutaneous bone-conduction devices. Archives of Otolaryngology–Head & Neck Surgery, 134, 265–268.

    Google Scholar 

  • Snik, A. F. M., Noten, J., & Cremers, C. W. R. J. (2004). Gain and maximum output of two electromagnetic middle ear implants: are real ear measurements helpful? Journal of American Academy of Audiology, 15, 249–257.

    Article  Google Scholar 

  • Snik, A. F. M., Mylanus, E. A. M., Proops, D. W., Wolfaardt, J. F., Hodgetts, W. E., Somers, T., Niparko, J. K., Wazen, J. J., Sterkers, O., Cremers, C. W., & Tjellström, A. (2005). Consensus statements on the BAHA system: where do we stand at present? Annals of Otology, Rhinology, and Laryngology 195, 2–12.

    Google Scholar 

  • Snik, A. F. M., van Duijnhoven, N. T., Mylanus, E. A., & Cremers, C. W. R. J. (2006). Estimated cost-effectiveness of active middle-ear implantation in hearing-impaired patients with severe external otitis. Archives of Otolaryngology–Head & Neck Surgery, 132, 1210–1215.

    Article  Google Scholar 

  • Snik, A. F. M., van Duijnhoven, N. T., Mulder, J. J., & Cremers, C. W. (2007). Evaluation of the subjective effect of middle ear implantation in hearing-impaired patients with severe external otitis. Journal of the American Academy of Audiology, 18, 496–503.

    PubMed  Google Scholar 

  • Snik, A. F. M., Verhaegen, V., Mulder, J. J, & Cremers, C. W. R. J. (2010). Cost-effectiveness of implantable middle ear hearing devices. Advances in Otorhinolaryngology, 69, 14–19.

    Google Scholar 

  • Stenfelt, S. (2005). Bilateral fitting of BAHAs and BAHA fitted in unilateral deaf persons: acoustical aspects. International Journal of Audiology, 44, 178–189.

    Article  PubMed  Google Scholar 

  • Stenfelt, S., & Goode, R.L. (2005). Bone-conducted sound: physiological and clinical aspects. Otology & Neurotology, 26, 1245–1261.

    Article  Google Scholar 

  • Stenfelt, S., HÃ¥kansson, B., Jonsson, R., & Granström, G. (2000). A bone-anchored hearing aid for patients with pure sensorineural hearing impairment: a pilot study. Scandinavian Audiology, 29, 175–185.

    Article  PubMed  CAS  Google Scholar 

  • Sterkers, O., Boucarra, D., Labassi, S., Bebear, J. P., Dubreuil, C., Frachet, B., Fraysse, B., Lavielle, J. P., Magnan, J., Martin, C., Truy, E., Uziel, A., & Vaneecloo, F. M. (2003). A middle ear implant, the Symphonix Vibrant Soundbridge: retrospective study of the first 125 patients implanted in France. Otology & Neurotology, 24, 427–436.

    Article  Google Scholar 

  • Suzuki, J. I. (1988). Middle ear implants: implantable hearing aids. Advances in Audiology 4. Basel, Switzerland: Karger.

    Google Scholar 

  • Suzuki, J. I., Kodera, K., Nagai, K., & Yabe, T. (1994). Long-term clinical results of the partially implantable piezoelectric middle ear implant. Ear Nose & Throat Journal, 73, 104–107.

    CAS  Google Scholar 

  • Tjellström, A., & HÃ¥kansson, B. (1995). The bone-anchored hearing aids: design principles, indications and long-term clinical results. Otolaryngologic Clinics of North America, 28, 53–72.

    PubMed  Google Scholar 

  • Tjellström, A., HÃ¥kansson, B., & Granström, G. (2001). Bone-anchored hearing aids. Current status in adults and children. Otolaryngologic Clinics of North America, 34, 337–364.

    Article  PubMed  Google Scholar 

  • Todt, I., Seidl, R. O., Mutze, S., & Ernst, A. (2004). MRI scanning and incus fixation in Vibrant Soundbridge implantation. Otology & Neurotology, 25, 969–972.

    Article  Google Scholar 

  • Tringali, S., Pergola, N., Ferber-Viart, C., Truy, E., Berger, P., & Dubreuil, C. (2008). Fully implantable hearing device as a new treatment of conductive hearing loss in Franceschetti syndrome. International Journal of Pediatric Otorhinolaryngology, 72, 513–517.

    Article  PubMed  Google Scholar 

  • Tringali, S., Pergola, N., Berger, P., & Dubreuil, C. (2009). Fully implantable hearing device with transducer on the round window as a treatment of mixed hearing loss. Auris Nasus Larynx 36, 353–358.

    Article  PubMed  Google Scholar 

  • Truy, E., Eshraghi, A. A., Balkany, T. J., Telishi, F. F., Van de Water, T., & Lavielle, J. P. (2006). Vibrant Soundbridge surgery: evaluation of transcanal surgical approaches. Otology & Neurotology, 27, 887–895.

    Article  Google Scholar 

  • Truy, E., Philibert, B., Vesson, J. F., Labassi, S., & Collet, L. (2008). Vibrant Soundbridge versus conventional hearing aid in sensorineural high-frequency hearing loss: a prospective study. Otology & Neurotology, 29, 684–687.

    Article  Google Scholar 

  • Uziel, A., Mondain, M., Hagen, P., Dejean, F., & Doucet, G. (2003). Rehabilitation for high-­frequency sensorineural hearing impairment in adults with the Symphonix Vibrant Soundbridge: a comparative study. Otology & Neurotology, 24, 775–783.

    Article  Google Scholar 

  • Vaneecloo, F. M., Ruzza, I., Hanson, J. N., Gerard, T., Dehaussy, J., Cory, M., Arrouet, C., & Vincent, C. (2001). Appareillage mono pseudo stereophonique par Baha dans les cophoses unilaterales: à propos de 29 patients. Revue de Laryngologie Otologie Rhinologie, 122, 343–350.

    PubMed  CAS  Google Scholar 

  • Verhaegen, V. J. O., Mylanus, E. A. M., Cremers, C. W. R. J., & Snik, A. F. M. (2008). Audiological application criteria for implantable hearing aid devices: a clinical experience at the Nijmegen ORL clinic. Laryngoscope, 118, 1645–1649.

    Article  PubMed  Google Scholar 

  • Verhaegen, V. J. O., Mulder, J. J. S., Mylanus, E. A. M., Cremers, C. W. R. J., & Snik, A. F. M. (2009). Profound mixed hearing loss: bone-anchored hearing aid system or cochlear implant? Annals of Otology, Rhinology, and Laryngology, 118, 693–697.

    PubMed  Google Scholar 

  • Vermeire, K., Broks, J. P. L., Wuyts, F. L., Cochet, E., Hofkens, A., & Van de Heyning, P. H. (2005). Quality-of-life benefit from cochlear implantation in the elderly. Otology & Neurotology, 26, 188–195.

    Article  Google Scholar 

  • Wade, P. S., Halik, J. J., & Chasin, M. (1992). Bone-conduction implants: transcutaneous versus percutaneous. Otolaryngology–Head and Neck Surgery, 106, 68–74.

    PubMed  CAS  Google Scholar 

  • Yanagihara, N., Honda, N., Sato, H., & Hinohira, Y. (2004). Piezoelectric semi-implantable middle ear hearing device: Rion device E-type, long-term results. Cochlear Implants International, Suppl. 1, 186–188.

    Article  Google Scholar 

  • Zenner, H. P., & Leysieffer, H. (2001). Total implantation of the implex TICA hearing amplifier implant for high-frequency sensorineural hearing loss. Otolaryngologic Clinics of North America, 34, 417–446.

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgements

I would like to express my sincere thanks to my colleagues Cor Cremers, Emmanuel Mylanus, Arjan Bosman, Jef Mulder, Myrthe Hol, and Carine Hendriks for their support through the years.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ad Snik .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer Science+Business Media, LLC

About this chapter

Cite this chapter

Snik, A. (2011). Implantable Hearing Devices for Conductive and Sensorineural Hearing Impairment. In: Zeng, FG., Popper, A., Fay, R. (eds) Auditory Prostheses. Springer Handbook of Auditory Research, vol 39. Springer, New York, NY. https://doi.org/10.1007/978-1-4419-9434-9_4

Download citation

Publish with us

Policies and ethics