Abstract
The safe operation of both clinical and pre-clinical MR systems is critical. There are a wide range of potential MR hazards. This chapter covers both the theoretical background to issues of MR safety and the guidance on more practical issues. The main sources of information on national and international MR safety guidance and advice are discussed, as well as local safety policies which are required for all MR installations. The projectile effect and other MR safety issues due to static and time-varying magnetic fields are considered, such as peripheral nerve stimulation, tissue heating and RF burns. Finally, contrast agents, auditory effects and medical implants and devices are discussed, as well as the less thought about issue of biological safety of clinical and pre-clinical MR systems.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
ICNIRP. Statement on medical magnetic resonance (MR) procedures: Protection of patients. Health Phys 2004;87(2):197–216.
Amendment to the ICNIRP. Statement on medical magnetic resonance (MR) procedures: Protection of patients. Health Phys 2009;97(3):259–261.
ICNIRP. Guidelines on limits of exposure to static magnetic fields. Health Phys 2009;96(4):504–514.
ICNIRP. Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz). Health Phys 1998;74(4):494–522.
ICNIRP. Statement on the “guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz)”. Health Phys 2009;97(3):257–259.
IEC 60601-2-33 Consol. ed2.1 (incl. am1): Medical electrical equipment – Part 2: Particular requirements for the safety of magnetic resonance equipment for medical diagnosis, 2006.
HPA Protection of patients and volunteers undergoing MRI procedures: Advice from the Health Protection Agency, 2008.
MHRA Device Bulletin: Safety Guidelines for Magnetic Resonance Imaging Equipment in Clinical Use (DB2007(03)), 2007.
ACR. Guidance document for MR safe practices. AJR 2007;188:1–27.
FDA Guidance for Industry and FDA Staff: Criteria for Significant Risk Investigations of Magnetic Resonance Diagnostic Devices, 2003.
EU Directive 2004/40/EC
EU Directive 2008/46/EC
Abart, J. et al. Peripheral nerve stimulation by time-varying magnetic fields. J Comput Assist Tomogr 1997;21(4):532–538.
Shellock, F. G. Reference Manual for Magnetic Resonance Safety, Implants, and Devices 2009. Los Angeles, CA: Biomedical Research Publishing Company; 2009.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer Science+Business Media, LLC
About this protocol
Cite this protocol
Simmons, A., Hakansson, K. (2011). Magnetic Resonance Safety. In: Modo, M., Bulte, J. (eds) Magnetic Resonance Neuroimaging. Methods in Molecular Biology, vol 711. Humana Press. https://doi.org/10.1007/978-1-61737-992-5_2
Download citation
DOI: https://doi.org/10.1007/978-1-61737-992-5_2
Published:
Publisher Name: Humana Press
Print ISBN: 978-1-61737-991-8
Online ISBN: 978-1-61737-992-5
eBook Packages: Springer Protocols