Abstract
The purpose of this study was to compare the physical characteristics of Low Energy High Resolution (LEHR), Low Energy Ultra High Resolution (LEUHR) and Medium Energy Low Penetration (MELP) collimators for simultaneous 99mTc and 123I imaging. MELP collimator performed well with 123I high-energy gamma photons, but low resolution makes it unsuitable to use for acquisition of small structures such as parathyroid adenomas. LEUHR collimators optimized for 99mTc have highest resolution, but the differences in septal penetration and sensitivity in favor of LEHR collimator needs to be tested with specific parathyroid phantoms.
Preview
Unable to display preview. Download preview PDF.
References
Inoue Y, Shirouzu I, Machida T, et al (2003). Physical characteristics of low and medium energy collimators for 123I imaging and simultaneous dual-isotope imaging. Nucl Med Commun, 24(11), 1195-1202.
Dobbeleir A, Hambye A, Franken P (1999). Influence of high-energy photons on the spectrum of iodine-123 with low- and medium-energy collimators: consequences for imaging with 123I-labelled compounds in clinical practice. Eur J Nucl Med, 26(6), 655-658.
Ivanovic M, Weber D, Loncaric S, et al (1994). Feasibility of dual radionuclide brain imaging with I-123 and Tc-99m. Med Phys, 21(5), 667-674.
Madsen M, O’Leary D, Andreasen N, et. al (1993). Dual isotope brain SPECT imaging for monitoring cognitive activation: physical considerations. Nucl Med Commun, 14(5), 391-396.
Devous M Sr, Lowe J, & Payne J (1992). Dual-isotope brain SPECT imaging with technetium-99m and iodine-123: validation by phantom studies. J Nucl Med, 33(11), 2030-2035.
Neumann D, Obuchowski N, & Difilippo F. (2008). Preoperative 123I/99mTc-Sestamibi Subtraction SPECT and SPECT/CT in Primary Hyperparathyroidism. J Nucl Med, 49(12), 2012-2017.
Neumann D, Esselstyn C Jr, Go R, et al (1997). Comparison of double-phase 99mTc-sestamibi with 123I-99mTc-sestamibi subtraction SPECT in hyperparathyroidism. AJR Am J Roentgenol, 169(6), 1671-1674
Ogasawara K, Hashimoto J, Ogawa K, et al (1998). Simultaneous acquisition of iodine-123 emission and technetium-99m transmission data for quantitative brain single-photon emission tomographic imaging. Eur J Nucl Med, 25(11), 1537-1544.
Shcherbinin S, Chamoiseau S, & Celler A (2012). Quantitative image reconstruction for dual-isotope parathyroid SPECT/CT: phantom experiments and sample patient studies. Phys Med Biol, 57(15), 4755-4769.
NEMA National Electrical Manufacturers Association, NEMA Standards Publication NU 1 (2007): Performance measurements of scintillation cameras.NEMA, Rosslyn, VA
Hindie E, Ugur O, Fuster D, et al (2009). 2009 EANM parathyroid guidelines. Eur J Nucl Med Mol Imaging; 36:1201-1216.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Tunninen, V., Kauppinen, T., Eskola, H. (2018). Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I. In: Eskola, H., Väisänen, O., Viik, J., Hyttinen, J. (eds) EMBEC & NBC 2017. EMBEC NBC 2017 2017. IFMBE Proceedings, vol 65. Springer, Singapore. https://doi.org/10.1007/978-981-10-5122-7_62
Download citation
DOI: https://doi.org/10.1007/978-981-10-5122-7_62
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-5121-0
Online ISBN: 978-981-10-5122-7
eBook Packages: EngineeringEngineering (R0)