Abstract
Purpose
To evaluate the imaging characteristics and the diagnostic value of both abdominal ultrasound and conventional abdominal x-ray in identifying ingested drug packages in “body packers.”
Materials and Methods
Twelve individuals were studied prospectively by abdominal ultrasound and by abdominal x-ray to rule out incorporated drug containers.
Results
Both abdominal ultrasound and abdominal x-ray correctly identified the 7 of 12 individuals who had ingested multiple drug packages. In 5 of the 12 individuals, ultrasound as well as abdominal x-ray were correctly unremarkable with regard to abdominal foreign bodies.
Conclusions
Abdominal ultrasound and abdominal x-ray both represent valuable diagnostic tools in the assessment of ingested drug packages. Abdominal x-ray is superior to ultrasound in differentiating ingested drug-filled condoms from “pseudocondoms.”
Similar content being viewed by others
References
Sinner W. The gastrointestinal tract as a vehicle for drug smuggling. Gastrointest Radiol 1981;6:319–323
Rauber K, Müller D. Abdomenübersichtsaufnahme zur Identifizierung von Rauschgiftschmugglern. Dtsch Med Wschr 1983;108:1549–1551
Suarez CA, Arango A, Lester JL. Cocaine-condom ingestion. JAMA 1977;238:1391–1392
Freed TA, Sweet LN, Gauder PJ. Balloon obturation bowel obstruction: a hazard of drug smuggling. AJR 1976;127:1033–1034
Fischbain DA, Wetli CV. Cocaine intoxication, delirium, and death in a body-packer. Ann Emerg Med 1980;9:429–430
Birnbaum BA, Balthazar EJ. Alcohol and drug abuse. In: Gore RM, Levine MS, Laufer I, eds. Textbook of gastrointestinal radiology, vol. 2. Philadelphia: WB Saunders. 1994:2626–2635
Wackerle B, Rupp N, V Clarmann M, Kahn T, Heller H, Feuerbach S. Demonstration of narcotic packages in “body-packers” by various imaging methods. In vitro and in vivo investigations [in German]. Fortschr Röntgenstr 1986;145:274–277
Pinsky MF, Ruggene DJ. Narcotic smuggling: the double-condom signs. J Can Assoc Radiol 1978;29:78–81
Author information
Authors and Affiliations
Additional information
An editorial commentary on this article follows on p. 339.
Rights and permissions
About this article
Cite this article
Hierholzer, J., Cordes, M., Tantow, H. et al. Drug smuggling by ingested cocaine-filled packages: conventional x-ray and ultrasound. Abdom Imaging 20, 333–338 (1995). https://doi.org/10.1007/BF00203366
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00203366