Skip to main content
Log in

Follow-up (6–9 years) results of the uncemented CLS spotorno stem

  • Original Article
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

The aseptic loosening rate in uncemented hip endoprostheses, especially the stem, is one of the most discussed problems among hip surgeons within the last few years. The first generation of uncemented stems had an essentially higher loosening rate compared with cemented stems. Although there are many reasons for this disappointing fact, the type of primary fixation and polyethylene wear are the two main ones. We reviewed 145 sequential uncemented CLS Spotorno stems, which achieved their primary fixation and bony in- or ongrowth predominantly in the metaphyseal region. The mean age of the patients was 54.9 years (range 37–76 years), and average follow-up was 7.8 years. The evaluation included both clinical (Merle d'Aubigné and Harris Hip Score) and radiographic parameters (plain X-rays). The medium-term follow-up showed a survival rate of 96.7% and good functional score results in more than 90%. Special attention was paid to the so-called thigh pain phenomenon which, despite current views, was found to be unexpectedly low (only one case). Although these results are encouraging, a further long-term follow-up of more than 10 years will have to show whether or not comparable results to cemented stems can be realised.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bands R, Pelker RR, Shine J, Bradburn H. Margolis R, Leach J (1991) The noncemented porous-coated total hip prosthesis. Clin Orthop 269:209–219

    Google Scholar 

  2. Bläsius K, Cotta H (1987) Erfahrungen mit der zementlosen Hüftendoprothese Spotorno/Weil. In: Thomas W (ed) Buchbeitrag I. Barmbecker Symposium, pp 68–74

  3. Bläsius K, Kauth J (1987) Erfahrungen mit der zementfreien Spotorno Hüftprothese. In: Refior HJ (ed) Zementfreie Implantation von Huftendoprothesen-Standortbestimmung und Tendenzen. Thieme, Stuttgart, pp 155–165

    Google Scholar 

  4. Bläsius K, Reichelt A (1983) Operative Ergebnisse der Hüftendoprothetik. Therapiewoche 33:458–464

    Google Scholar 

  5. Brudet J (1979) Ergebnisse des operativen Gelenkersatzes mit dem zementfreien Hüftendoprothesensystem Spotorno-Weil (CLS-CLW). Dissertation, Justus Liebig Universität, Giessen

    Google Scholar 

  6. Callaghan JJ, Dysart SH, Savory CG (1988) The uncemented porous coated anatomic THP. J Bone Joint Surg [Am] 70:337–346

    Google Scholar 

  7. Cotta H, Niethard FU, Bldsius K (1989) Zementfreie CLS Hüftendoprothese. Munich Med Wochenschr 3:86–89

    Google Scholar 

  8. Dodge BM, Fitzrandolph R, Collins DN (1991) Noncemented porous coated anatomic total hip arthroplasty. Clin Orthop 269: 16–24

    Google Scholar 

  9. Engh C (1982) Hip arthroplasty with a Moore prosthesis with porous coating. Clin Orthop 176:52–66

    Google Scholar 

  10. Engh CA, Bobyn JB (1988) The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 231:7–28

    Google Scholar 

  11. Engh CA, Bobyn JD, Glassman AH (1987) Porous coated hip replacement. J Bone Joint Surg [Br] 69:45–55

    Google Scholar 

  12. Herberts P, Malchau H, Romanus B (1988) Uncemented total hip replacement in young adults — a Scandinavian multicenter PCA study. Annual meeting, Scandinavian Orthop. Assoc., Arhus, Denmark, June 8–11. Acta Orthop Scand Suppl 59: 227–228

    Google Scholar 

  13. Huiskes R (1990) The various stress patterns of press fit, ingrown and cemented femoral stems. Clin Orthop 261:27–37

    Google Scholar 

  14. Johnston RC, Fitzgerald RH, Harris WH et al. (1990) Clinical and radiographic evaluation of THR. J Bone Joint Surg [Am] 72:161–168

    Google Scholar 

  15. Lintner R, Zweymüller K, Brand G (1986) Tissue reaction to titanium endoprosthesis. J Arthroplasty 1: 3183–3195

    Google Scholar 

  16. Maloney WJ, Jasty M, Harris WH et al. (1990) Endosteal erosion in association with stable uncemented femoral components. J Bone Joint Surg [Am] 72:1025–1034

    Google Scholar 

  17. Mittelmeier H (1974) Zementlose Verankerung von Endoprothesen nach dem Tragrippenprinzip. Z Orthop 112:27–33

    Google Scholar 

  18. Morscher E, Mathys R (1975) Erste Erfahrungen mit einer zementlosen isoelastischen Totalendoprothese der Hüfte. Z Orthop 113:745–749

    Google Scholar 

  19. Parhofer R, Münch W (1984) Experience with revision arthroplasties for failed cemented total hip replacements using uncemented lord- and PM-prosthesis. In: Morscher E (ed) The cementless fixation of hip endoprostheses. Springer, Berlin Heidelberg New York, pp 145–149

    Google Scholar 

  20. Phillips TW, Messieh SS (1988) Cementless hip replacement for arthritis. J Bone Joint Surg [Br] 70:750–775

    Google Scholar 

  21. Pörschke W (1988) Zementlose Hüftgelenksendoprothetik, Spotorno-Endoprothese (CLS-CLW), Med Orthop Techn 108: 4–6

    Google Scholar 

  22. Reigstad A, Brandt M, Bye K (1988) Results of a prospective comparison between a cemented and an uncemented hip prosthesis. Acta Orthop Scand 59 (Suppl. 227):31

    Google Scholar 

  23. Rothman RH, Cohn JC (1990) Cemented versus cementless total hip arthroplasty. Clin Orthop 254:153–169

    Google Scholar 

  24. Spotomo L, Schenk RU, Dietschi C et al. (1987) Unsere Erfahrungen mit nicht zementierten Prothesen. Orthopäde 16:225–238

    Google Scholar 

  25. Tsamatropoulos A, Koutris G, Tseres K, Kouvaras J, Antonakopoulos P, Triantaphilou N (1990) Comparative study in cementless THR between press fitted of grooved-system and of porous coated stems. 4th PanHellenic Congress, Athens

  26. Wilson RL, Stulberg SD, Mehlhoff M (1991) Total hip replacement with cemented, uncemented and hybrid prosthesis. J Bone Joint Surg [Am] 73:257–270

    Google Scholar 

  27. Zweymüller K (1984) First clinical experience with an uncemented modular femoral prosthesis system with a wrought TiAl4V stem and Al2O3-ceramic head. In: Morscher E (ed) The cementless fixation of hip endoprostheses. Springer, Berlin Heidelberg New York, pp 275–278

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bülow, J.U., Scheller, G., Arnold, P. et al. Follow-up (6–9 years) results of the uncemented CLS spotorno stem. Arch Orthop Trauma Surg 115, 190–194 (1996). https://doi.org/10.1007/BF00434551

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00434551

Keywords

Navigation