Validity of the Wescor's sweat conductivity analyzer for the assessment of sweat electrolyte concentrations

  • Short Communication
  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Abstract

The purpose of this study was to compare the “NaCl equivalent” values determined by the Wescor's sweat conductivity analyzer (Sweat-Chek) with the sweat Na+ and Cl concentration values measured by conventional methods. The sweat was induced by 60-min exercise and collected by a closed-pouch collector. The “NaCl equivalent” values determined by the sweat conductivity analyzer (mean: 75 mmol · L−1, range: 38 − 122, n = 72) were significantly (P < 0.05) greater than Na+ concentration values (mean: 7I mmol · L−1, range: 24 − 123, n = 72) measured by flame photometry and Cl concentration values (mean : 61 mmol· L−1, range: 18 – 100, n = 48) measured by coulometric titration. The differences were most accen-tuated for low concentration values. The 95% confidence-agreement intervals around the mean differences between methods were 11 mmol· L−1 (14%) for both Na+ and Cl. The SweatChek conductivity analyzer is a portable instrument which approximates the actual Na+ and Cl concentrations in sweat but with a positive bias probably due to the other unmeasured anions present in sweat.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  • Bossvert P, Desuelle AN, Candas V (1994) The effects of acute alcohol ingestion on body thermoregulatim during exercise in warm conditions in men. (submitted)

  • Boisvert P, Nakamura K, Shimai S, Brisson GR, Tanaka M (1993a) A modified, local sweat collector for warm and humid conditions. Eur J Appl Physiol 66: 547–551

    Google Scholar 

  • Boisvet P, Brisson GR, Péronnet F (1993b) Effect of plasma prolactin on sweat rate and sweat composition during exercise in man. Am J Physiol 264 (Renal Fluid Electrolyte Physiol 33 ): F816-F820

    Google Scholar 

  • Brisson GR, Boisvert P, Péronnet F, Perrault H, Boisvert D, Lafond JS (1991) A simple and disposable sweat collector. Eur J Appl Physiol 63: 269–272

    Google Scholar 

  • Clarke JT, Elian E, Shwachman H (1961) Components of sweat. Am J Dis Child 101: 490

    Google Scholar 

  • Cole EC, Boucher MJ (1986) Use of a new sample-collection device (Macroduct) in anion analysis of human sweat. Clin Chem 32 (7): 1375–1378

    Google Scholar 

  • Costill, DL (1977) Sweating: its composition and effects on body fluids. In: Milvy, P (ed) The marathon: physiological, medical, epidemiological, and psychological studies. New York Academy of Science 301: 160–174

  • Gibson LE, Cooke RE (1959) A test for concentration of electrolytes in sweat in cystic fibrosis using pilocarpine by iontophoresis. Pediatrics 23: 545–549

    Google Scholar 

  • Hammond KB, Turcios NL, Gibson LE (1988) An evaluation of the Wescor Sweat-Chek Conductivity Analyzer. Pediat Pulm Suppl. 2: 139 (Abstract)

    Google Scholar 

  • Sato K (1977) The physiology, pharmacology, and biochemistry of the eccrine sweat gland Rev Physiol Biochem Pharmacol 79: 51–131

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Boisvert, P., Candas, V. Validity of the Wescor's sweat conductivity analyzer for the assessment of sweat electrolyte concentrations. Europ. J. Appl. Physiol. 69, 176–178 (1994). https://doi.org/10.1007/BF00609413

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00609413

Key words

Navigation