Abstract
Twenty-four-hour home esophageal pH monitoring is proposed in order to study gastroesophageal reflux (GER) so that prolonged use of costly hospital equipment and staff can be curtailed and the diagnostic accuracy of the examination improved. Eighty-six patients affected by GER symptoms and 20 healthy volunteers underwent 24-hr home esophageal pH monitoring, x-rays, and endoscopy of the upper gastrointestinal tract to investigate reliability of outpatient recording. Fifteen more patients consecutively underwent out- and inpatient recording to detect possible differences between these methods in the two daily periods. Outpatient monitoring was well tolerated in 94.7% of the patients; 14.3% of them markedly reduced their routine activities. The range of normality of outpatient recording does not differ from that of inpatients. In the 15 patients who consecutively underwent out-and inpatient monitoring, no significant differences were reported. The sensitivity of 24-hr home esophageal pH recording is 0.85, the specificity 1, the accuracy for negative prediction 0.68, and the accuracy for positive prediction 1. The reliability of 24-hr home esophageal pH monitoring is comparable to inpatient recording. It allows hospital cost reduction and is also better tolerated by patients but has not greatly improved the diagnostic accuracy of the gastroesophageal reflux pH monitoring.
Similar content being viewed by others
References
Cooper JD: Discussion,in: DeMeester TR, Ching I-Wang, Werly JA, Pellegrini CA, Little AG, Klementschitsch P, Bermudez G, Johnson LF, Skinner DB: Technique, indications, and clinical use of 24-hour esophageal pH monitoring. J Thorac Cardiovasc Surg 79:656–667, 1980
Falor WH, Chang B, White HA, Kraus JM, Taylor B, Hansel JR, Kraus FC: Twenty-four hour esophageal pH monitoring by telemetry. Cost-effective use in outpatients. Am J Surg 142:514–516, 1981
Branicki FJ, Evans DF, Ogilvie AL, Atkinson MA, Hardcastle JD: Ambulatory monitoring of esophageal pH in reflux oesophagitis using a portable radiotelemetry system. Gut 23:992–998, 1982
Weiser HF, Lepsien G, Muller-Lissner SA, Pace F, Blum AL, Siewert R: Reflux characteristics of healthy volunteers examined by long-term phmetry.In Motility of the Digestive Tract. M Weinbeck (ed). New York, Raven Press, 1982, pp 287–291
DeMeester TR: The limitations of 24-hour pH monitoring of the esophagus.In Esophageal Disorders: Pathophysiology and Therapy. TR DeMeester, DB Skinner (eds). New York, Raven Press, 1985, pp 109–117
Choniere L, Miller L, Ilves R, Cooper JD: A simplified method of esophageal pH monitoring for assessment of gastroesophageal reflux. Ann Thorac Surg 36:596–603, 1983
Schlesinger PK, Donahue PE, Schmid B, Layden TJ: Limitation of 24-hour intraesophageal pH monitoring in the hospital setting. Gastroenterology 89:797–804, 1985
Benz LJ, Hootkin LA, Margulies ST, Donner MW, Cauthorne T, Hendrix TR: A comparison of clinical measure ment of gastroesophageal reflux. Gastroenterology 62:1–5, 1972
Postlethwait RW (ed): Surgery of the Esophagus. New York, Appleton-Century-Crofts, 1979, pp 266–278
Pearson FG, Cooper ID, Ilves R, Todd TRJ, Jamieson WRE: Massive hiatal hernia with incarceration: A report of 35 cases. Ann Thorac Surg 35(a):45–51, 1982
Ismail-Beigi F, Horton PF, Pope CE II: Histological consequences of gastro-esophageal reflux in man. Gastroenterology 58:163–174, 1970
Paull A, Trier J, Dalton M, Camp R, Leob P, Goyal R: The hystologic spectrum of Barrett's esophagus. N Engl J Med 295:476–480, 1976
Savary M, Miller G: L'oesophage—manuel et atlas d'endoscopie. Gassmann AG (ed). GE Soleure 1977
Hafter E: Hiatus hernia. Technical features: Radiological examination-interpretation of x-ray findings.In Diseases of the Esophagus. G Vantrappen, J Hellemans (eds). Berlin, Springer-Verlag, 1974, pp 757–763
Donner MW, Margulies SI: Radiographic examination.In Gastroesophageal Reflux and Hiatal Hernia. DB Skinner, RHR Belsey, GD Zuidema (eds). Boston, Little, Brown, 1972, pp 59–85
Pringot J, Ponette E: Radiological examination of the esophagus.In Diseases of the Esophagus. G Vantrappen, J Hellemans (eds). Berlin, Springer-Verlag, 1974, pp 119–203
Winans CS, Harris LD: Quantitation of lower esophageal sphincter competence. Gastroenterology 52:773–778, 1967
Dodds WJ: Instrumentation and methods for intraluminal esophageal manometry. Arch Intern Med 136:515–523, 1976
Mattioli S, Pilotti V, Bragaglia RB, Bortolotti M, Zannoli R, Gozzetti G: Usefulness of home 24-hour esophageal pH monitoring in the diagnosis and management of reflux esophagitis.In Esophageal Disorders: Pathophysiology and Therapy. TR DeMeester, DB Skinner (eds). New York, Raven Press, 1985, pp 599–604
Johnson LF, DeMeester TR: Twenty-four hour pH monitoring of the distal esophagus. A quantitative measure of gastro-esophageal reflux. Am J Gastroenterol 62:325–332, 1974
Johnson LF, DeMeester JR: Development of the 24-hour intraesophageal pH monitoring composite scoring system. J Clin Gastroenterol 8(a):52–58, 1986
Ransohoff DF, Feinstein AR: Problems of spectrum and bias in evaluating the efficacy of diagnostic tests. N Engl J Med 299:926–978, 1978
DeMeester TR, Ching I-Wang, Wernly JA, Pellegrini CA, Little AG, Klementschitsch P, Bermudez G, Johnson LF, Skinner DB: Technique, indications and clinical use of 24 hour esophageal pH monitoring. J Thorac Cardiovasc Surg 79:656–667, 1980
Branicki FJ, Evans DF, Jones A, Ogilvie Al, Atkinson M, Hardcastle JD: Analysis and scoring of ambulatory recordings of gastroesophageal reflux.In Esophageal Disorders: Pathophysiology and Therapy. TR DeMeester, DB Skinner (eds). New York, Raven Press, 1985, pp 571–577
Lillemoe KD, Johnson LF, Harmon JW: Role of the components of the gastroduodenal contents in experimental acid esophagitis. Surgery 92:276–284, 1982
Johnson LF, Harmon JW: Experimental esophagitis in a rabbit model. J Clin Gastroenterol 8(1):26–44, 1986
Little AG, Martinez EI, De Meester TR, Blough RM, Skinner DB: Duodenogastric reflux and reflux esophagitis. Surgery 96:447–454, 1984
Gozzetti G, Pilotti V, Spangaro M, Bassi F, Grigioni W, Carulli N, Loria P, Felice V, Lerro F, Mattioli S: Pathophysiology and natural history of acquired short esophagus. Surgery 102:507–514, 1987
Little AG, DeMeester TR, Skinner DB: Combined gastric and esophageal 24 hour pH monitoring in patients with gastro-esophageal reflux. Surg Forum 30:351–352, 1979
Mattioli S, Pilotti V, Zannoli R, Felice V, Castellini A, Conci A, Gozzetti G: Gastroesophageal and duodenogastric reflux: Simultaneous twenty-four-hour home recording with a three-probe system (3EG pH).In Diseases of the Esophagus. JR Siewert, AH Holscher (eds). Berlin, Springer-Verlag, 1987, pp 836–838
Author information
Authors and Affiliations
Additional information
Supported by the Ministere Pubblica Istruzione, Rome; and Finanziamenti per studi e ricerche 40%, Com. 06, Cat 12-07 imp. 11515, University of Bologna.
Rights and permissions
About this article
Cite this article
Mattioli, S., Pilotti, V., Spangaro, M. et al. Reliability of 24-hour home esophageal ph monitoring in diagnosis of gastroesophageal reflux. Digest Dis Sci 34, 71–78 (1989). https://doi.org/10.1007/BF01536157
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01536157