Remote auscultatory patient monitoring during magnetic resonance imaging

  • Original Articles
  • Published:
Journal of Clinical Monitoring Aims and scope Submit manuscript

Abstract

A system for patient monitoring during magnetic resonance imaging (MRI) is described. The system is based on remote auscultation of heart sounds and respiratory sounds using specially developed pickup heads that are positioned on the precordium or at the nostrils and connected to microphones via polymer tubing. The microphones operate in a differential mode outside the strong magnetic field to reduce various sources of interference from the MRI equipment. After amplification, the signal is transmitted as infrared light to a small, battery-operated receiver and a headphone set. Thus, the patient can be simultaneously auscultated both inside and outside the shielded MRI room by infrared transmission through a metal mesh window. Bench tests of the system show that common mode acoustic noise is suppressed by approximately 30 dB in the frequency region of interest (100–1,000 Hz), and that polymer tubing having a diameter of approximately 2 mm can be used for efficient sound transmission. Recordings in situ show satisfactory detection of both heart sounds and respiratory sounds, although the signal is somewhat masked by noise during imaging. A clinical test incorporating 17 sedated or anesthetized patients was also performed. In all but four cases, the quality of the breath and heart sounds was regarded as acceptable or better.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Kean D, Smith M. Magnetic resonance imaging principles and applications. London: Heinemann Medical Books, 1986

    Google Scholar 

  2. Goudsouzian N, Vacanti FX. Current questions in patient safety: monitoring for MRI. APSF Newsletter 1987:33–35

  3. Hök B, Bythell V, Bengtsson M. Development of a wireless stethoscope for auscultatory monitoring during anaesthesia. Med Biol Eng Comput 1988;26:317–320

    Google Scholar 

  4. Roth JL, Nugent M, Gray JE, Julsrud RR. Patient monitoring during magnetic resonance imaging. Anesthesiology 1985;62:80–83

    Google Scholar 

  5. Selldén H, De Chateau P, Ekman G, et al. Circulatory monitoring of children during anaesthesia in low-field magnetic resonance imaging. Acta Anaesthesiol Scand 1990;34:41–43

    Google Scholar 

  6. Shellock FG. Monitoring during MRI. Med Electron 1986;100:93–97

    Google Scholar 

  7. Lindoff B. Problem med overvakning vid MRT. Med Tek 1989:38

  8. Shellock FG, Slimp GL. Severe burn of the finger caused by using a pulse oximeter during MR imaging. Am J Roentgenol 1989;153:1105

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

The authors are indebted to Dr Hans Selldén, St. Göran's Hospital, Stockholm, for his contributions to the clinical part of the study.

This study was supported by the Swedish Board for Technical Development.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Henneberg, S., Hök, B., Wiklund, L. et al. Remote auscultatory patient monitoring during magnetic resonance imaging. J Clin Monitor Comput 8, 37–43 (1992). https://doi.org/10.1007/BF01618086

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01618086

Key words

Navigation