Abstract
The accuracy of pulse oximetry for the prediction of oxygen saturation of arterial blood in patients with shock has been hardly studied. This study was undertaken to determine if O2 arterial saturation estimated by the Biox 3700 pulse oximeter (SpO2) with an ear probe could reliably substitute for the measurements of O2 saturation (HbO2) with an IL-282 Co-Oximeter in samples of arterial blood obtained from 24 caucasian patients. All patients were mechanically ventilated and needed vasoactive drugs (dopamine and/or dobutamine). Of 24 patients 13 had shock: cardiogenic (n=6) and septic (n=7). The mean difference between HbO2 and SpO2 was 2.49%±4.24, with a 95% confidence interval of 0.7% to 4.3% (p=0.009). There were clinically important differences between both methods since in 9 of 24 patients (37%) SpO2 values were at least 4% lower or greater than HbO2. This disagreement was also apparent in patients with (6/13, 46%) or without shock (3/11, 27%). To conclude, pulse oximetry is not always a sufficiently reliable method to predict HbO2 in patients with or without shock treated with vasoactive drugs.
Article PDF
Similar content being viewed by others
References
Rebuck AS, Chapman KR, D'Urzo A (1983) The accuracy and response characteristics of a simplified ear oximeter. Chest 83:860–864
Burki Nk, Albert RK (1983) Noninvasive monitoring of arterial blood gases. A report of the ACCP on respiratory pathophysiology. Chest 83:666–670
Ries AL, Farrow JT, Clausen JL (1985) Accuracy of two ear oximeters at rest and during exercise in pulmonary patients. Am Rev Respir Dis 132:685–689
Kagle DM, Alexander CM, Berko R, Ginffre M, Gross JB (1987) Evaluation of the Ohmeda 3700 pulse oximeter: steady-state and transient response characteristics. Anesthesiology 66:376–380
Dies AL (1987) Oximetry — know thy limits. Chest 91:316
Severinghaus JW, Naifeh KH (1987) Accuracy of response of six pulse oximeters to profound hypoxia. Anesthesiology 67:551–558
Velasco J, Ibáñez J, Raurich JM (1989) Pulsioximetría de oreja en pacientes críticos: validación de su exactitud. Med Intensiva 13:278–281
Kim SK, Baidwan BS, Petty TL (1984) Clinical evaluation of a new finger oximeter. Crit Care Med 12:910–912
Mihm FG, Halperin BD (1985) Noninvasive detection of profound arterial desaturations using a pulse oximetry device. Anesthesiology 62:85–87
Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical assessment. Lancet I:307–310
Ries AL, Prewitt LM, Johnson JF (1989) Skin color and ear oximetry. Chest 96:287–290
Baker SJ, Tremper KK (1987) The effect of carbon monoxide inhalation on pulse oximeter signal detection. Anesthesiology 67:599–603
Jubran A, Tobin MJ (1990) Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator dependent patients. Chest 97:1420–1425
Chapman KR, Liu FLW, Watson RM, Rebuck AS (1986) Range of accuracy of two wavelengths oximetry. Chest 4:540–542
Severinghaus JW, Spellman MJ (1990) Pulse oximeter failure threshold in hypotension and vasoconstriction. Anesthesiology 75:532–537
Wilkins CJ, Moores M, Hanning CD (1989) Comparison of pulse oximeters: effects of vasoconstriction and venous engorgement. Br J Anaesth 62:439–444
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ibáñez, J., Velasco, J. & Raurich, J.M. The accuracy of the biox 3700 pulse oximeter in patients receiving vasoactive therapy. Intensive Care Med 17, 484–486 (1991). https://doi.org/10.1007/BF01690773
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01690773