Skip to main content
Log in

Modified enzyme immunoassay to detect hepatitis C virus antibodies in oral fluid

  • Notes
  • Published:
European Journal of Clinical Microbiology and Infectious Diseases Aims and scope Submit manuscript

Abstract

Samples of oral fluid collected from 18 patients seropositive for hepatitis C virus (HCV) and 49 seronegative patients were tested for the presence of HCV antibodies with two modified serum-screening kits. The following sensitivities and specificities were obtained: HCV 3.0 assay, 72% and 98%, respectively, and Monolisa anti-HCV assay, 100% and 100%, respectively. The modified Monolisa assay demonstrated a striking concordance between serum and saliva samples. The use of oral fluids offers a convenient and noninvasive method applicable to HCV epidemiological studies and screening of high-risk groups.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Major CJ, Read SE, Coates RA, Francis A, McLaughlin BJ, Millson M, Shepherd F, Fanning M, Calzavara L, Mac-Fadden D, Johnson JK, O'Shaughnessy MV: Comparison of saliva and blood for human immunodeficiency virus prevalence testing. Journal of Infectious Diseases 1991, 163: 699–702.

    PubMed  Google Scholar 

  2. Gore SM, Bird AG, Burns SM, Goldberg DJ, Ross AJ, MacGregor J: Drug injection and HIV prevalence in inmates of Glenochill prison. British Medical Journal 1995, 310: 293–296.

    PubMed  Google Scholar 

  3. Parry JV, Perry KR, Mortimer PP: Sensitive tests for viral antibodies in saliva; an alternative to tests on serum. Lancet 1987, 2: 72–75.

    PubMed  Google Scholar 

  4. Perry KR, Palmer D, McAlpine L, Mortimer PP, Parry JV: Ten anti HCV screening assays, Medical Devices Agency evaluation report. Her Majesty's Stationery Office, London, 1995.

    Google Scholar 

  5. Thieme T, Yoshihara P, Piacentini S, Beller M: Clinical evaluation of oral fluid samples for diagnosis of viral hepatitis. Journal of Clinical Microbiology 1992, 30: 1076–1079.

    PubMed  Google Scholar 

  6. Sherman KE, Creager RI, O'Brien J, Sargent S, Piacentini S, Thieme T: The use of oral fluid for hepatitis C antibody screening. American Journal of Gastroenterology 1994, 89: 2025–2027.

    PubMed  Google Scholar 

  7. Roy KM, Bagg J, Follett EA, Brewer A, Lowe GD: Hepatitis C virus in saliva of haemophiliac patients attending an oral surgery unit. British Journal of Oral & Maxillofacial Surgery 1996, 34: 162–165.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

McIntyre, P.G., Laszlo, J., Appleyard, K. et al. Modified enzyme immunoassay to detect hepatitis C virus antibodies in oral fluid. Eur. J. Clin. Microbiol. Infect. Dis. 15, 882–884 (1996). https://doi.org/10.1007/BF01691223

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01691223

Keywords

Navigation