Running spectrum analysis as an aid in the representation and interpretation of electrogastrographic signals

  • Physiological Measurement
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The recording of gastric myoelectrical activity by means of cutaneous electrodes attached to the external abdominal wall is termed electrogastrography. Respiration and motion artefacts hamper the interpretation of electrogastrographic signals. Running spectrum analysis, using the fast Fourier transform, seems to provide a concise spectral representation of electrogastrographic data. In this paper the concept of running spectrum analysis is presented in detail using test signals consisting of frequency modulated sine waves and actual recordings from dog and man. Especially the visual interpretable representation in appropriate plots is emphasised and discussed. It is demonstrated that tachygastrias with a duration of the order of 30s can easily be recognised in the spectra. In most cases the gastric frequency can be recognised in the spectra. It is concluded, therefore, that running spectrum analysis has to be considered an attractive noninvasive method to study gastric myoelectrical activity in dog and man.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Abell, T. &Malagelada, J. R. (1985) Glucagon-evoked gastric dysrhythmias in humans shown by an improved electrogastrographic technique.Gastroenterol.,88, 1932–1940.

    Google Scholar 

  • Brown, B. H., Smallwood, R. H., Duthie, H. L. andStoddard, C. J. (1975) Intestinal smooth muscle electrical potentials recorded from surface electrodes.Med. & Biol. Eng.,13, 97–103.

    Google Scholar 

  • Daniel, E. E. (1965) The electrical and contractile activity of the pyloric region in dogs and the effect of drugs.Gastroenterol.,49, 403–418.

    Google Scholar 

  • Geldof, H., van der Schee, E. J., Smout, A. J. P. M. andGrashuis, J. L. (1984) Electrogastrography. InGastric and gastroduodenal motility,Akkermans,L. M. A.,Johnson,A. G. andRead,N. W. (Eds.) Preager, New York, 163–173.

    Google Scholar 

  • Geldof, H., van der Schee, E. J., van Blankenstein, M. andGrashuis, J. L. (1986) An electrogastrographic study of gastric myoelectrical activity in patients with unexplained nausea and vomiting.Gut,27, 799–808.

    Google Scholar 

  • Gullikson, G. W., Okuda, H., Shimizum, M. andBass, P. (1980) Electrical arrhythmias in gastric antrum of the dog.Am. J. Physiol.,239, G59-G68.

    Google Scholar 

  • Kay, S. M. N. andMarple, S. L. (1981) Spectrum analysis—a modern perspective.IEEE Proc.,69, 1380–1419.

    Article  Google Scholar 

  • Kelly, K. A. andCode, C. F. (1971) Canine gastric pacemaker.Am. J. Physiol.,220, 112–118.

    Google Scholar 

  • Levy, J. B. andLinkens, D. A. (1984) Spectral analysis of shorttime biomedical data using adaptive filters.IEEE Proc.,131, 164–169.

    Google Scholar 

  • Linkens, D. A. andCannell, A. E. (1974) Interactive graphic analysis of gastrointestinal electrical signals.IEEE Trans. Biomed. Eng.,21, 335–339.

    Google Scholar 

  • Linkens, D. A. andDatardina, S. P. (1978) Estimation of frequencies of gastrointestinal electrical rhythms using autoregressive modelling.Med. & Biol. Eng. & Comput.,16, 262–268.

    Google Scholar 

  • Mirizzi, N. andScafoglieri, U. (1983) Optimal direction of the electrogastrographic signal in man.,21, 385–389.

    Google Scholar 

  • Smallwood, R. H., Brown, B. H. andDuthie, H. L. (1975) An approach to the objective analysis of intestinal smooth muscle potentials recorded from surface electrodes. Proc. 5th Int. Symp. Gastrointestinal motility, Leuven, Belgium.

  • Smout, A. J. P. M., van der Schee, E. J. andGrashuis, J. L. (1979) Gastric pacemaker rhythm in conscious dogs.Am. J. Physiol.,237, E279-E283.

    Google Scholar 

  • Smout, A. J. P. M., van der Schee, E. J. andGrashuis, J. L. (1980) What is measured in electrogastrography?Dig. Dis. Sci.,25, 179–187.

    Article  Google Scholar 

  • Taylor, I., Duthie, H. L., Smallwood, R. andLinkens, D. (1975) Large bowel myoelectric activity in man.Gut,16, 808–814.

    Google Scholar 

  • Telander, R. L., Morgan, K. G., Kreulen, D. L., Schmalz, P. F., Kelly, K. A. andSzurszewski, J. H. (1978) Human gastric atony with tachygastria and gastric retention.Gastroenterol.,75, 497–501.

    Google Scholar 

  • van der Schee, E. J., Smout, A. J. P. M. andGrashaus, J. L. (1982) Application of running spectrum analysis to electrogastrographic signals recorded from dog and man. InMotility of the digestive tract.Weinbeck, M. (Ed.), Raven Press, 241–250.

  • Volkers, A. C. W., van der Schee, E. J. andGrashuis, J. L. (1983) Electrogastrography in the dog: waveform analysis by a coherent averaging technique.Med. & Biol. Eng. & Comput.,21, 56–64.

    Google Scholar 

  • You, C. H., Chey, W. Y., Lee, K. Y., Menguy, R. andBortoff, A. (1981) Gastric and small intestinal myoelectrical dysrhythmia associated with chronic intractable nausea and vomiting.Ann. Int. Med.,95, 449–451.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

van der Schee, E.J., Grashuis, J.L. Running spectrum analysis as an aid in the representation and interpretation of electrogastrographic signals. Med. Biol. Eng. Comput. 25, 57–62 (1987). https://doi.org/10.1007/BF02442821

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02442821

Keywords

Navigation