Abstract
Thein situ forces and their distribution within the human anterior cruciate ligament (ACL) can clarify this ligament's role in the knee and help to resolve controversies regarding surgical treatment of ACL deficiency. We used a universal force-moment sensor (UFS) to determine the magnitude, direction, and point of application of thein situ forces in the ACL in intact human cadaveric knees. Unlike previous studies, this approach does not require surgical intervention, the attachment of mechanical devices to or near the ACL, ora priori assumptions about the direction ofin situ force. Anterior tibial loads were applied to intact knees, which were limited to 1 degree of freedom at 30o flexion. Thein situ forces developed in the ACL were lower than the applied force for loads under 80 N, but larger for applied loads of more than 80 N. The direction of the force vector corresponded to that of the anteromedial (AM) portion of the ACL insertion on the tibial plateau. The point of force application was located in the posterior section of the anteromedial portion of the tibial insertion site. The anterior and posterior aspects of the anteromedial portion of the ACL supported 25% and 70% of thein situ force, respectively, with the remainder carried by the posterolateral portion. We believe that the data obtained with this new UFS methodology improves our understanding of the role of the ACL in knee function, and that this methodology can be easily extended to study the function of other ligaments.
Similar content being viewed by others
References
Ahmed, A. M., D. L. Burke, N. A. Duncan, and K. H. Chan. Ligament tension patterns in the flexed knee in combined passive anterior tibial translation and axial rotation.J. Orthop. Res. 10:854–867, 1992.
Ahmed, A. M., A. Hyder, D. L. Burke, and K. H. Chan. In-vivo ligament tension patterns in the flexed knee in passive loading.J. Orthop. Res. 5:217–230, 1987.
Barry, D., and A. M. Ahmed. Design and performance of a modified buckle transducer for the measurement of ligament tension.J. Biomech. Eng. 108:149–152, 1986.
Burgess, A. Profile analysis of the Wechsler intelligence scales: a new index of subtest scatter.Br. J. Clin. Psychol. 30:257–263, 1991.
Butler D. L., E. T. Martin, A. D. Kaiser, E. S. Grood, K. J. Chun, and A. N. Sodd. The effects of flexion and tibial rotation on the 3-D orientations and lengths of human anterior cruciate ligament bundles.Trans. O.R.S. 13:59, 1988.
Butler, D. L., F. R. Noyes, and E. S. Grood. Ligamentous restraints to anterior-posterior drawer in the human knee: a biomechanical study.J. Bone Joint Surg. 62-A:259–270, 1980.
France, P. E., A. U. Daniels, M. E. Goble, and H. K. Dunn. Simultaneous quantitation of knee ligament force.J. Biomech. 16:553–564, 1983.
Fujie, H., G. A. Livesay, S. L-Y. Woo, S. Kashiwaguchi, and G. Blomstrom. The use of a universal force-moment sensor to determine in-situ forces in ligaments: a new methodology.J. Biomech. Eng. 117:1–7, 1995.
Fujie, H., K. Mabuchi, S. L-Y. Woo, G. A. Livesay, S. Arai, and Y. Tsukamoto. The use of robotics technology to study human joint kinematics: a new methodology.J. Biomech. Eng. 115:211–217, 1993.
Girgis, F. G., J. L. Marshall, and A. R. S. Al Monajem. The cruciate ligaments of the knee joint: anatomical and experimental analysis.Clin. Orthop. 106:216–231, 1975
Hefzy, M. S., and E. S. Grood. Sensitivity of insertion locations on length patterns of anterior cruciate ligament fibers.J. Biomech. Eng. 108:73–82, 1986.
Holden, J. P., E. S. Grood, and J. F. Cummings. The effects of flexion angle and tibial rotation on measurement of anteromedial band force in the goat ACL.Trans. O.R.S. 16:588, 1991.
Holden, J. P., E. S. Grood, D. L. Korvick, J. F. Cummings, D. L. Butler, and D. I. Bylski-Austrow. In vivo forces in the anterior cruciate ligament: direct measurements during walking and trotting in a quadruped.J. Biomech. 27:517–526 1994.
Hollis, J. M., Development and application of a method for determining the in-situ forces in anterior cruciate ligament bundles. San Diego: University of California, Ph.D. Dissertation, 1988.
Hollis, M. J., J. P. Marcin, S. Horibe, and S. L.- Y. Woo. Load determination in ACL fiber bundles under knee loading.Trans. O.R.S. 13:58, 1988.
Hollis, M. J., S. Takai, D. J. Adams, S. Horibe, and S. L-Y. Woo. The effects of knee motion and external loadingon the length of the anterior cruciate ligament: A kinematic study.J. Biomech. Eng. 113:208–214, 1991.
Huba, G. J. How unusual is a profile of test scores?J. Psychoed. Assess. 4:321–325, 1985.
Huba, G. J. Statistics for computer based test interpretations: bivariate and multivariate uniqueness.Ed. Psychol. Measure. 46:331–334, 1986.
Jasty, M., W. D. Lew, and J. L. Lewis. In-vitro ligament forces in the normal knee using buckle transducers.Trans. O.R.S. 7:241, 1982.
Lewis, J. L., M. Jasty, and R. Wixson. Functional load directions for the two bands of the anterior cruciate ligament.Trans. O.R.S. 5:307, 1980.
Lewis, J. L., W. D. Lew, J. A. Hill, K. J. Ohland, S. Kirstukas, and R. E. Hunter. Knee joint motion and ligamental forces before and after ACL reconstruction.J. Biomech. Eng. 111:97–106, 1989.
Lewis, J. L., W. D. Lew and J. Schmidt. A note on the application and evaluation of the buckle transducer for knee ligament force measurement.J. Biomech. Eng. 104:125–128, 1982.
Lewis, J. L., W. D. Lew, and J. Schmidt. Description and error evaluation of an in-vitro knee joint testing system.J. Biomech. Eng. 110:238–248, 1988.
Markolf, K. L., J. F. Gorek, J. M. Kabo, and M. S. Shapiro. Direct measurement of resultant forces in the anterior cruciate ligament.J. Bone Joint Surg. 72A:557–567, 1990.
Markolf, K. L., D. C. Wascher, and G. A. M. Finerman. Direct in vitro measurement of forces in cruciate ligaments. Part II: the effect of section of the posterolateral structures.J. Bone Joint Surg. 75A:387–394, 1993.
Norwood, L. A., and M. J. Cross. Anterior cruciate ligament: functional anatomy of its bundles in rotatory instabilities.Am. J. Sports Med. 7:23–26, 1979.
Sidles, J. A., R. V. Larson, J. L. Garbini, D. J. Downey, and F. A. Matsen III. Ligament length relationships in the moving knee.J. Orthop. Res. 6:593–610, 1988.
Takai, S., S. L-Y. Woo, G. A. Livesay, D. J. Adams, and F. H. Fu. Determination of the in-situ loads on the human anterior cruciate ligament.J. Orthop. Res. 11:686–695 1993.
Vahey, J. W., and L. F. Draganich. Tensions in the anterior and posterior cruciate ligaments of the knee during passive loading: predicting the ligament loads from in-situ measurements.J. Orthop. Res. 9:529–538, 1991.
Wascher, D. C., K. L. Markolf, M. S. Shapiro, and G. A. M. Finerman. Direct in vitro measurement of the forces in cruciate ligaments. Part I: the effect of multiplane loading of the intact knee.J. Bone Joint Surg. 75A:377–386, 1993.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Livesay, G.A., Fujie, H., Kashiwaguchi, S. et al. Determination of thein situ forces and force distribution within the human anterior cruciate ligament. Ann Biomed Eng 23, 467–474 (1995). https://doi.org/10.1007/BF02584446
Received:
Revised:
Accepted:
Issue Date: