Skip to main content
Log in

Home blood glucose monitoring

Effectiveness in a general population of patients who have non-insulin-dependent diabetes mellitus

  • Original Articles
  • Published:
Journal of General Internal Medicine Aims and scope Submit manuscript

Abstract

Objective: To determine whether home blood glucose monitoring as used by non-insulin-dependent diabetes mellitus patients followed in primary care nonresearch clinics improves glycemic control or reduces utilization of the outpatient laboratory.

Design: A retrospective chart reviewfor 229 patients receiving outpatient supplies for home testing of either blood or urine.

Setting: A variety of nonresearch clinics at a Veterans Affairs Medical Center, a teaching hospital affiliated with an academic university medical center.

Patients: Outpatient veterans followed in diabetes, primary care, internal medicine, or endocrine clinics.

Interventions: None.

Measurements and main results: The mean glycosylated hemoglobin for an unselected group monitoring glycemic control by urine testing only was 11.32% and for those using blood monitoring was 11.37%. Frequency and duration of monitoring had no apparent impact on glucose control. There was no decrease in the utilization of the laboratory among those patients practicing home blood glucose monitoring.

Conclusions: For non-insulin-dependent diabetic patients followed in a nonresearch clinic setting, the benefits of home blood glucose monitoring remain to be proven.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. American Diabetes Associations. Consensus statement on self-monitoring of blood glucose. Diabetes Care. 1990;13:41–6.

    Article  Google Scholar 

  2. Chandler PT, Chandler SA. Outpatient self-management of severe diabetes. South Med J. 1981;74:1061–4.

    PubMed  CAS  Google Scholar 

  3. Schiffrin A, Belmonte M. Multiple daily self-glucose monitoring: its essential role in long-term glucose control in insulin-dependent diabetic patients treated with pump and multiple subcutaneous injections. Diabetes Care. 1982;5:479–84.

    Article  PubMed  CAS  Google Scholar 

  4. Warner MW. Efficacy of home glucose monitoring in diabetic pregnancy. Am J Med. 1983;75:592–6.

    Article  Google Scholar 

  5. Walford S, Gale EAM, Allison SP, Tattersall RB. Self-monitoring of blood-glucose. Lancet. 1978;1:732–5.

    Article  PubMed  CAS  Google Scholar 

  6. Brownlog M, Vlassara H, Cerami A. Measurement of glycosylated amino acids and peptides from urine of diabetic patients using affinity chromatography. Diabetes. 1980;29:1044–7.

    Article  Google Scholar 

  7. Snedecor GW, Cochran WG. Statistical Methods, 7th edition. Ames, IA: Iowa University Press, 1980.

    Google Scholar 

  8. Mann NP, Noronha JL, Johnston DI. A prospective study to evaluate the benefits of long-term self-monitoring of blood glucose in diabetic children. Diabetes Care. 1984;7:322–6.

    Article  PubMed  CAS  Google Scholar 

  9. Lam KSL, Ma JTC, Chan EYM, Yeung RTT. Sustained improvement in diabetic control on long-term self-monitoring of blood glucose. Diabetes Res Clin Pract. 1986;2:165–71.

    Article  PubMed  CAS  Google Scholar 

  10. Bergman M, Felig P. Self-monitoring of blood glucose levels in diabetes. Arch Intern Med. 1984;144:2029–34.

    Article  PubMed  CAS  Google Scholar 

  11. Sonsken PH, Judd SL, Lowy C. Home monitoring of blood-glucose. 1978;1:730–2.

    Google Scholar 

  12. Mazze RS, Shamoon H, Pasmantier R, Lucido D, Murphy J. Reliability of blood glucose monitoring by patients with diabetes mellitus. Am J Med. 1984;77:211–7.

    Article  PubMed  CAS  Google Scholar 

  13. Wing RR, Epstein LH, Nowalk MP, Scott N, Koeske R, Hagg S. Does self-monitoring of blood glucose levels improve dietary compliance for obese patients with type II diabetes? Am J Med. 1986;81:830–6.

    Article  PubMed  CAS  Google Scholar 

  14. Newman WP, Laqua D, Engelbrecht D. Impact of glucose self-monitoring on glycohemoglobin values in a veteran population. Arch Intern Med. 1990;150:107–10.

    Article  PubMed  CAS  Google Scholar 

  15. Worth R, Home PD, Johnston DG, et al. Intensive attention improves glycaemic control in insulin-dependent diabetes without further advantage from home blood glucose monitoring: results of a controlled trial. BMJ. 1982;285:1233–40.

    Article  PubMed  CAS  Google Scholar 

  16. Allen TB, De Long ER, Feussner JR. Impact of glucose self-monitoring on non - insulin-treated patients with type II diabetes mellitus. Diabetes Care. 1990;13:1044–50.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Received from the Ambulatory Care Service, Denver Veterans Affairs Medical Center, Denver, Colorado.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Klein, C.E., Oboler, S.K., Prochazka, A. et al. Home blood glucose monitoring. J Gen Intern Med 8, 597–601 (1993). https://doi.org/10.1007/BF02599711

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02599711

Key words

Navigation