Reliability of Peak Exercise Stroke Volume Assessment by Impedance Cardiography in Patients with Residual Right Outflow Tract Lesions After Congenital Heart Disease Repair

  • Original Article
  • Published:
Pediatric Cardiology Aims and scope Submit manuscript

Abstract

Global ventricular response to exercise may be useful in follow-up of patients with residual right outflow tract lesions after congenital heart disease repair. In this context, impedance cardiography is considered accurate for stroke volume (SV) measurement during exercise testing, however, to date, only partial assessment of its reliability has been reported. We retrospectively evaluated relative and absolute reliability of peak SV by impedance cardiography during exercise using intraclass correlation (ICC) and standard error of measurement (SEM) in this population. Peak SV was measured in 30 young patients (mean age 14.4 years ± 2.1) with right ventricular outflow tract reconstruction who underwent two cardiopulmonary exercise tests at a mean one-year interval. SV was measured using a signal morphology impedance cardiography analysis device (PhysioFlow®) and was indexed to body surface area. ICC of peak indexed SV measurement was 0.80 and SEM was 10.5%. High heterogeneity was seen when comparing patients according to peak indexed SV; in patients with peak SV < 50 ml/m2 (15 patients), ICC rose to 0.95 and SEM dropped to 2.7%, while in patients with a peak SV > 50 ml/m2 relative and absolute reliability decreased (ICC = 0.45, SEM = 12.2%). Peak exercise SV assessment by a PhysioFlow® device represents a highly reliable method in patients with residual right outflow tract lesions after congenital heart disease repair, especially in patients with peak SV < 50 ml/m2. In this latter group, a peak SV decrease > 7.3% (corresponding to the minimum “true” difference) should be considered a clinically-relevant decrease in global ventricular performance and taken into account when deciding whether to perform residual lesion removal.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Legendre A, Richard R, Pontnau F, Jais JP, Dufour M, Grenier O et al (2016) Usefulness of maximal oxygen pulse in timing of pulmonary valve replacement in patients with isolated pulmonary regurgitation. Cardiol Young 26(7):1310–1318

    Article  PubMed  Google Scholar 

  2. Eynon N, Sagiv M, Amir O, Ben-Sira D, Goldhammer E, Amir R. The effect of long-term beta-adrenergic receptor blockade on the oxygen delivery and extraction relationship in patients with coronary artery disease. J Cardiopulm Rehabil Prev. 2008; 28(3):189–94. Eur J Appl Physiol. 2001, 85(3–4): 202–7

  3. Charloux A, Lonsdorfer-Wolf E, Richard R, Lampert E, Oswald-Mammosser M, Mettauer B et al (2000) A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method. Eur J Appl Physiol 82(4):313–320

    Article  CAS  PubMed  Google Scholar 

  4. Welsman J, Bywater K, Farr C, Welford D, Armstrong N (2005) Reliability of peak VO(2) and maximal cardiac output assessed using thoracic bioimpedance in children. Eur J Appl Physiol 94(3):228–234

    Article  PubMed  Google Scholar 

  5. Duncan GE, Howley ET, Johnson BN (1997) Applicability of VO2max criteria: discontinuous versus continuous protocols. Med Sci Sports Exerc 29(2):273–278

    Article  CAS  PubMed  Google Scholar 

  6. Wasserman K, Hansen JE, Sue DY, Casaburi R, Whipp BJ (1999) Principles of exercise testing and interpretation. Lippincott, Philadelphia, p 193

    Google Scholar 

  7. Richard R, Lonsdorfer-Wolf E, Charloux A, Doutreleau S, Buchheit M, Oswald-Mammosser M et al (2001) Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph device. Eur J Appl Physiol 85(3–4):202–207

    Article  CAS  PubMed  Google Scholar 

  8. Cohen J (1988) Statistical power analysis for the behavioral sciences, 2nd edn. Erlbaum, Hillsdale

    Google Scholar 

  9. Atkinson G, Nevill AM (1998) Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med 26(4):217–238

    Article  CAS  PubMed  Google Scholar 

  10. Dupuy O, Mekary S, Berryman N, Bherer L, Audiffren M, Bosquet L (2012) Reliability of heart rate measures used to assess post-exercise parasympathetic reactivation. Clin Physiol Funct Imaging 32(4):296–304

    Article  PubMed  Google Scholar 

  11. Munro B (1997) Statistical methods for health care research, 3rd edn. Lippincott, New York, pp 1–444

    Google Scholar 

  12. Currier D (1990) Elements of research in physical therapy. Williams and Wilkins, Baltimore

    Google Scholar 

  13. Weir JP (2005) Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res 19(1):231–240

    PubMed  Google Scholar 

  14. Schultz MG, Climie RED, Nikolic SB, Ahuja KD, Sharman JE (2012) Reproducibility of cardiac output derived by impedance cardiography during postural changes and exercise. Artery Res 6(2):78–84

    Article  Google Scholar 

  15. Hillis DL, Firth BG, Winniford MD (1985) Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output. Am J Cardiol 56:764–768

    Article  CAS  PubMed  Google Scholar 

  16. Bergersen L, Gauvreau K, Jenkins KJ, Lock JE (2008) Adverse event rates in congenital cardiac catheterization: a new understanding of risks. Congenit Heart Dis. 3(2):90–105

    Article  PubMed  Google Scholar 

  17. Rowland TW, Melanson EL, Popowski BE, Ferrone LC (1998) Test-retest reproducibility of maximum cardiac output by Doppler echocardiography. Am J Cardiol 81(10):1228–1230

    Article  CAS  PubMed  Google Scholar 

  18. Vinet A, Nottin S, Lecoq AM, Guenon P, Obert P (2001) Reproducibility of cardiac output measurements by Doppler echocardiography in prepubertal children and adults. Int J Sports Med 22(6):437–441

    Article  CAS  PubMed  Google Scholar 

  19. Roest AA, Kunz P, Lamb HJ, Helbing WA, van der Wall EE, de Roos A (2001) Biventricular response to supine physical exercise in young adults assessed with ultrafast magnetic resonance imaging. Am J Cardiol 87(5):601–605

    Article  CAS  PubMed  Google Scholar 

  20. Rowland T, Mannie E, Gawle L (2001) Dynamics of left ventricular diastolic filling during exercise: a Doppler echocardiographic study of boys 10 to 14 years old. Chest 120(1):145–150

    Article  CAS  PubMed  Google Scholar 

  21. Kemps HM, Thijssen EJ, Schep G, Sleutjes BT, De Vries WR, Hoogeveen AR et al (1985) Evaluation of two methods for continuous cardiac output assessment during exercise in chronic heart failure patients. J Appl Physiol 105(6):1822–1829

    Article  Google Scholar 

  22. Tonelli AR, Alnuaimat H, Li N, Carrie R, Mubarak KK (2011) Value of impedance cardiography in patients studied for pulmonary hypertension. Lung 189(5):369–375

    Article  PubMed  Google Scholar 

  23. Taylor K, La Rotta G, McCrindle BW, Manlhiot C, Redington A, Holtby H (2011) A comparison of cardiac output by thoracic impedance and direct fick in children with congenital heart disease undergoing diagnostic cardiac catheterization. J Cardiothorac Vasc Anesth 25(5):776–779

    Article  PubMed  Google Scholar 

  24. Buheitel G, Scharf J, Hofbeck M, Singer H. Determination of heart time volume using the Fick principle in the early postoperative phase after correction of congenital heart defects. Comparison of the calculation of arterio-mixed venous oxygen differences and pulmonary oxygen uptake with the calculation of arterial-central venous oxygen differences and pulmonary oxygen uptake. Klin Padiatr. 1994; 206(3):151–6

  25. Ebrahim M, Hegde S, Printz B, Abcede M, Proudfoot JA, Davis C (2016) Evaluation of Impedance Cardiography for Measurement of Stroke Volume in Congenital Heart Disease. Pediatr Cardiol 37(8):1453–1457

    Article  PubMed  Google Scholar 

  26. Legendre A, Guillot A, Ladouceur M, Bonnet D (2017) Usefulness of stroke volume monitoring during upright ramp incremental cycle exercise in young patients with Fontan circulation. Int J Cardiol 15(227):625–630

    Article  Google Scholar 

  27. Martino M, Gledhill N, Jamnik V (2002) High VO2max with no history of training is primarily due to high blood volume. Med Sci Sports Exerc 34(6):966–971

    Article  PubMed  Google Scholar 

  28. Kipps AK, Graham DA, Harrild DM, Lewis E, Powell AJ, Rhodes J (2011) Longitudinal exercise capacity of patients with repaired tetralogy of fallot. Am J Cardiol 108(1):99–105

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We thank Anne Marie Luangpraseuth, a nurse in the pediatric cardiology department, and the ARCFA for financial support for editing services provided by Dr Sarah MacKenzie.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Antoine Legendre.

Ethics declarations

Conflict of interest

Antoine Legendre, Damien Bonnet, Laurent Bosquet declares that they have no conflict of interest.

Ethical Approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. As a retrospective study, no formal consent was required.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Legendre, A., Bonnet, D. & Bosquet, L. Reliability of Peak Exercise Stroke Volume Assessment by Impedance Cardiography in Patients with Residual Right Outflow Tract Lesions After Congenital Heart Disease Repair. Pediatr Cardiol 39, 45–50 (2018). https://doi.org/10.1007/s00246-017-1725-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00246-017-1725-3

Keywords

Navigation