Abstract
Colonography based on magnetic resonance imaging (MRI) appears to be a promising technique for polyp assessment in the colon. Several studies have evaluated this method for colonic assessment in patients with inflammatory bowel disease. We briefly review different methodologies such as dark lumen and bright lumen techniques for abdominal MRI. In addition, recently published studies concerning the sensitivity and accuracy in detecting inflammatory bowel changes in inflammatory bowel disease using MRI are discussed.
Similar content being viewed by others
References
Schreyer AG, Gölder S, Seitz J, Herfarth H (2003) New diagnostic avenues in inflammatory bowel diseases. Capsule endoscopy, magnetic resonance imaging and virtual enteroscopy. Dig Dis 21:129–137
Schreyer AG, Seitz J, Feuerbach S, et al. (2004) Modern imaging using computer tomography and magnetic resonance imaging for inflammatory bowel disease (IBD). Inflamm Bowel Dis 10:45–54
Ajaj W, Pelster G, Treichel U, et al. (2003) Dark lumen magnetic resonance colonography: comparison with conventional colonoscopy for the detection of colorectal pathology. Gut 52:1738–1743
Lauenstein TC, Herborn CU, Vogt FM, et al. (2001) Dark lumen MR-colonography: initial experience. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:785–789
Luboldt W, Steiner P, Bauerfeind P, et al. (1998) Detection of mass lesions with MR colonography: preliminary report. Radiology 207:59–65
Goehde SC, Hunold P, Vogt FM, et al. (2005) Full-body cardiovascular and tumor MRI for early detection of disease: feasibility and initial experience in 298 subjects. AJR 184:598–611
Luboldt W, Debatin JF (1998) Virtual endoscopic colonography based on 3D MRI. Abdom Imaging 23:568–572
Pickhardt PJ, Choi JR, Hwang I, et al. (2003) Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults. N Engl J Med 349:2191–2200
Johnson CD, Toledano AY, Herman BA, et al. (2003) Computerized tomographic colonography: Performance evaluation in a retrospective multicenter setting. Gastroenterology 125:688–695
Johnson CD, Harmsen WS, Wilson LA, et al. (2003) Prospective blinded evaluation of computed tomographic colonography for screen detection of colorectal polyps. Gastroenterology 125:311–319
Rieber A, Wruk D, Potthast S, et al. (2000) Diagnostic imaging in Crohn’s disease: comparison of magnetic resonance imaging and conventional imaging methods. Int J Colorectal Dis 15:176–181
Schreyer AG, Geissler A, Albrich H, et al. (2004) Abdominal MRI after enteroclysis or with oral contrast in patients with suspected or proven Crohn’s disease. Clin Gastroenterol Hepatol 2:491–497
Gölder SK, Schreyer AG, Endlicher E, Feuerbach S, Schölmerich J, Kullmann F, Rogler S, Seitz J, Herfarth H (2005) Comparison of capsule endoscopy and magnetic resonance (MR)-enteroclysis in suspected small bowel disease. Int J Colorectal Dis in press
Voderholzer WA, Beinhoelzl J, Rogalla P, et al. (2005) Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut 54:369–373
Schreyer AG, Goelder S, Scheibl K, et al. (2005) Dark lumen magnetic resonance enteroclysis in combination with MRI colonography for whole bowel assessment in patients with Crohn’s disease: first clinical experience. Inflamm Bowel Dis 11:388–394
Jardine VL, Sala E, Lomas DJ (2005) MR colonography: baseline appearance of the unprepared rectosigmoid. Br J Radiol 78:202–206
Goehde SC, Descher E, Boekstegers A, et al. (2005) Dark lumen MR colonography based on fecal tagging for detection of colorectal masses: accuracy and patient acceptance. Abdom Imaging 30:576–583
Iannaccone R, Laghi A, Catalano C, et al. (2004) Computed tomographic colonography without cathartic preparation for the detection of colorectal polyps. Gastroenterology 127:1300–1311
Luboldt W, Bauerfeind P, Steiner P, et al. (1997) Preliminary assessment of three-dimensional magnetic resonance imaging for various colonic disorders. Lancet 349:1288–1291
Schreyer AG, Rath HC, Kikinis R, et al. (2005) Comparison of magnetic resonance imaging colonography with conventional colonoscopy for the assessment of intestinal inflammation in patients with inflammatory bowel disease: a feasibility study. Gut 54:250–256
Scheibl K, Schreyer AG, Kullmann F, et al. (2005) Magnetic resonance imaging gastrography: evaluation of the dark lumen technique compared with conventional gastroscopy in patients with malignant gastric disease. Invest Radiol 40:164–172
Hagspiel KD, Altes TA, Mugler JP III, et al. (2000) MR virtual colonography using hyperpolarized (3)He as an endoluminal contrast agent: demonstration of feasibility. Magn Reson Med 44:813–816
Lam WW, Leung WK, Wu JK, et al. (2004) Screening of colonic tumors by air-inflated magnetic resonance (MR) colonography. J Magn Reson Imaging 19:447–452
Madsen SM, Thomsen HS, Munkholm P, et al. (2002) Inflammatory bowel disease evaluated by low-field magnetic resonance imaging. Comparison with endoscopy, 99mTc-HMPAO leucocyte scintigraphy, conventional radiography and surgery. Scand J Gastroenterol 37:307–316
Debatin JF, Lauenstein TC (2003) Virtual magnetic resonance colonography. Gut 52(suppl 4):iv17–iv22
Biancone L, Fiori R, Tosti C, et al. (2003) Virtual colonoscopy compared with conventional colonoscopy for stricturing postoperative recurrence in Crohn’s disease. Inflamm Bowel Dis 9:343–350
Schreyer AG, Herfarth H, Kikinis R, et al. (2002) 3D modeling and virtual endoscopy of the small bowel based on magnetic resonance imaging in patients with inflammatory bowel disease. Invest Radiol 37:528–533
Schreyer AG, Fielding JR, Warfield SK, et al. (2000) Virtual CT cystoscopy: color mapping of bladder wall thickness. Invest Radiol 35:331–334
Jaume S, Ferrant M, Macq B, et al. (2003) Tumor detection in the bladder wall with a measurement of abnormal thickness in CT scans. IEEE Trans Biomed Eng 50:383–390
Maccioni F, Viscido A, Broglia L, et al. (2000) Evaluation of Crohn disease activity with magnetic resonance imaging. Abdom Imaging 25:219–228
Schunk K, Reiter S, Kern A, et al. (2001) Hydro-MRI in inflammatory bowel diseases: a comparison with colonoscopy and histology. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:731–738
Koh DM, Miao Y, Chinn RJ, et al. (2001) MR imaging evaluation of the activity of Crohn’s disease. AJR 177:1325–1332
Neurath MF, Vehling D, Schunk K, et al. (2002) Noninvasive assessment of Crohn’s disease activity: a comparison of 18F-fluorodeoxyglucose positron emission tomography, hydromagnetic resonance imaging, and granulocyte scintigraphy with labeled antibodies. Am J Gastroenterol 97:1978–1985
Gasche C, Turetschek K (2005) Value of MR colonography for assessment of inflammatory bowel disease? Believe what you see—see what you believe. Gut 54:181–182
Author information
Authors and Affiliations
Corresponding author
Additional information
An erratum to this article can be found online at http://dx.doi.org/10.1007/s00261-011-9713-1
Rights and permissions
About this article
Cite this article
Schreyer, A.G., Scheibl, K., Heiss, P. et al. MR colonography in inflammatory bowel disease. Abdom Imaging 31, 302–307 (2006). https://doi.org/10.1007/s00261-005-0377-6
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00261-005-0377-6