Abstract
CT enterography has rapidly gained acceptance as a method for visualizing the small bowel lumen, wall and mesentery for a variety of clinical indications. Focusing on the identification of Crohn’s disease, and vascular and neoplastic small bowel masses, this review summarizes oral contrast agents and CT acquisition techniques used for CT enterography, alternatives that can be used to tailor the exam for specific indications, and how such variations affect the appearance of a variety of pathologies at CT imaging.
Similar content being viewed by others
References
Triester SL, Leighton JA, Leontiadis GI et al. (2006) A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn’s disease. Am J Gastroenterol 101:954–964
Mata A, Llach J, Castells A et al. (2005) A prospective trial comparing wireless capsule endoscopy and barium contrast series for small-bowel surveillance in hereditary GI polyposis syndromes. Gastrointest Endosc 61:721–725
Bodily KD, Fletcher JG, Solem CA, et al. (2006) Crohn’s disease: mural attenuation and thickness at contrast-enhanced CT enterography-correlation with endoscopic and histologic findings of inflammation. Radiology 238(2):505–516
Hassan C, Cerro P, Zullo A et al. (2003) Computed tomography enteroclysis in comparison with ileoscopy in patients with Crohn’s disease. Int J Colorectal Dis 18:121–125
Mazzeo S, Caramella D, Battolla L et al. (2001) Crohn disease of the small bowel: spiral CT evaluation after oral hyperhydration with isotonic solution. J Comput Assist Tomogr 25:612–616
Voderholzer WA, Beinhoelzl J, Rogalla P et al. (2005) Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut 54:369–373
Wold PB, Fletcher JG, Johnson CD et al. (2003) Assessment of small bowel Crohn disease: noninvasive peroral CT enterography compared with other imaging methods and endoscopy—feasibility study. Radiology 229:275–281
Bender GN, Timmons JH, Williard WC et al. (1996) Computed tomographic enteroclysis: one methodology. Invest Radiol 31:43–49
Mako EK, Mester AR, Tarjan Z et al. (2000) Enteroclysis and spiral CT examination in diagnosis and evaluation of small bowel Crohn’s disease. Eur J Radiol 35:168–175
Rollandi GA, Curone PF, Biscaldi E et al. (1999) Spiral CT of the abdomen after distention of small bowel loops with transparent enema in patients with Crohn’s disease. Abdom Imaging 24:544–549
Booya F, Fletcher JG, Huprich JE et al. (2006) Active Crohn disease: CT findings and interobserver agreement for enteric phase CT enterography. Radiology 241:787–795
Solem CA, Loftus EV Jr, Fletcher JG, et al. (2008) Small-bowel imaging in Crohn’s disease: a prospective, blinded, 4-way comparison trial. Gastrointest Endosc May 29 [Epub ahead of print]
Ajaj W, Goehde SC, Schneemann H et al. (2004) Oral contrast agents for small bowel MRI: comparison of different additives to optimize bowel distension. Eur Radiol 14:458–464
Lauenstein TC, Schneemann H, Vogt FM et al. (2003) Optimization of oral contrast agents for MR imaging of the small bowel. Radiology 228:279–283
Young B, Fletcher J, Booya F et al. (2008) Head-to-head comparison of oral contrast agents for cross-sectional enterography: small bowel distention, timing and side effects. JCAT 32:32–38
Kuehle CA, Ajaj W, Ladd SC et al. (2006) Hydro-MRI of the small bowel: effect of contrast volume, timing of contrast administration, and data acquisition on bowel distention. AJR Am J Roentgenol 187:W375–W385
Megibow AJ, Babb JS, Hecht EM et al. (2006) Evaluation of bowel distention and bowel wall appearance by using neutral oral contrast agent for multi-detector row CT. Radiology 238:87–95
Schindera ST, Nelson RC, DeLong DM et al. (2007) Multi-detector row CT of the small bowel: peak enhancement temporal window—initial experience. Radiology 243:438–444
Vandenbroucke F, Mortelé KJ, Tatli S, et al. (2007) Noninvasive multidetector computed tomography enterography in patients with small-bowel Crohn’s disease: is a 40-second delay better than 70 seconds? Acta Radiol Oct 23:1–9 [Epub ahead of print]
Huprich JE, Fletcher JG, Alexander JA et al. (2008) Obscure gastrointestinal bleeding: evaluation with 64-section multiphase CT enterography—initial experience. Radiology 246:562–571
Huprich J, Fletcher J, Fidler J, et al. (2007) A prospective comparison of multiphase CT enterography with wireless capsule endoscopy in the management of obscure GI bleeding. In:RSNA. Chicago, IL
Scheffel H, Pfammatter T, Wildi S et al. (2007) Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT. Eur Radiol 17:1555–1565
Yoon W, Jeong YY, Shin SS et al. (2006) Acute massive gastrointestinal bleeding: detection and localization with arterial phase multi-detector row helical CT. Radiology 239:160–167
Vogel J, da Luz Moreira A, Baker M et al. (2007) CT enterography for Crohn’s disease: accurate preoperative diagnostic imaging. Dis Colon Rectum 50:1761–1769
Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284
Siddiki H, Fletcher J, Bruining D et al. (2007) Performance of lower-dose CT enterography for detection of inflammatory Crohn’s disease. In:RSNA. Chicago, IL
McCollough CH, Bruesewitz MR, Kofler JM Jr (2006) CT dose reduction and dose management tools: overview of available options. Radiographics 26:503–512
Acknowledgments
Potential Conflicts of Interest: Grant support from Siemens Medical Solutions, E-E-Z-EM, Inc., and GE Healthcare; Educational License to GE Healthcare.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Fletcher, J.G. CT enterography technique: theme and variations. Abdom Imaging 34, 283–288 (2009). https://doi.org/10.1007/s00261-008-9411-9
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00261-008-9411-9