Skip to main content
Log in

CT enterography technique: theme and variations

  • Published:
Abdominal Imaging Aims and scope Submit manuscript

Abstract

CT enterography has rapidly gained acceptance as a method for visualizing the small bowel lumen, wall and mesentery for a variety of clinical indications. Focusing on the identification of Crohn’s disease, and vascular and neoplastic small bowel masses, this review summarizes oral contrast agents and CT acquisition techniques used for CT enterography, alternatives that can be used to tailor the exam for specific indications, and how such variations affect the appearance of a variety of pathologies at CT imaging.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Triester SL, Leighton JA, Leontiadis GI et al. (2006) A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn’s disease. Am J Gastroenterol 101:954–964

    Article  PubMed  Google Scholar 

  2. Mata A, Llach J, Castells A et al. (2005) A prospective trial comparing wireless capsule endoscopy and barium contrast series for small-bowel surveillance in hereditary GI polyposis syndromes. Gastrointest Endosc 61:721–725

    Article  PubMed  Google Scholar 

  3. Bodily KD, Fletcher JG, Solem CA, et al. (2006) Crohn’s disease: mural attenuation and thickness at contrast-enhanced CT enterography-correlation with endoscopic and histologic findings of inflammation. Radiology 238(2):505–516

    Google Scholar 

  4. Hassan C, Cerro P, Zullo A et al. (2003) Computed tomography enteroclysis in comparison with ileoscopy in patients with Crohn’s disease. Int J Colorectal Dis 18:121–125

    PubMed  Google Scholar 

  5. Mazzeo S, Caramella D, Battolla L et al. (2001) Crohn disease of the small bowel: spiral CT evaluation after oral hyperhydration with isotonic solution. J Comput Assist Tomogr 25:612–616

    Article  PubMed  CAS  Google Scholar 

  6. Voderholzer WA, Beinhoelzl J, Rogalla P et al. (2005) Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut 54:369–373

    Article  PubMed  CAS  Google Scholar 

  7. Wold PB, Fletcher JG, Johnson CD et al. (2003) Assessment of small bowel Crohn disease: noninvasive peroral CT enterography compared with other imaging methods and endoscopy—feasibility study. Radiology 229:275–281

    Article  PubMed  Google Scholar 

  8. Bender GN, Timmons JH, Williard WC et al. (1996) Computed tomographic enteroclysis: one methodology. Invest Radiol 31:43–49

    Article  PubMed  CAS  Google Scholar 

  9. Mako EK, Mester AR, Tarjan Z et al. (2000) Enteroclysis and spiral CT examination in diagnosis and evaluation of small bowel Crohn’s disease. Eur J Radiol 35:168–175

    Article  PubMed  CAS  Google Scholar 

  10. Rollandi GA, Curone PF, Biscaldi E et al. (1999) Spiral CT of the abdomen after distention of small bowel loops with transparent enema in patients with Crohn’s disease. Abdom Imaging 24:544–549

    Article  PubMed  CAS  Google Scholar 

  11. Booya F, Fletcher JG, Huprich JE et al. (2006) Active Crohn disease: CT findings and interobserver agreement for enteric phase CT enterography. Radiology 241:787–795

    Article  PubMed  Google Scholar 

  12. Solem CA, Loftus EV Jr, Fletcher JG, et al. (2008) Small-bowel imaging in Crohn’s disease: a prospective, blinded, 4-way comparison trial. Gastrointest Endosc May 29 [Epub ahead of print]

  13. Ajaj W, Goehde SC, Schneemann H et al. (2004) Oral contrast agents for small bowel MRI: comparison of different additives to optimize bowel distension. Eur Radiol 14:458–464

    Article  PubMed  Google Scholar 

  14. Lauenstein TC, Schneemann H, Vogt FM et al. (2003) Optimization of oral contrast agents for MR imaging of the small bowel. Radiology 228:279–283

    Article  PubMed  Google Scholar 

  15. Young B, Fletcher J, Booya F et al. (2008) Head-to-head comparison of oral contrast agents for cross-sectional enterography: small bowel distention, timing and side effects. JCAT 32:32–38

    Google Scholar 

  16. Kuehle CA, Ajaj W, Ladd SC et al. (2006) Hydro-MRI of the small bowel: effect of contrast volume, timing of contrast administration, and data acquisition on bowel distention. AJR Am J Roentgenol 187:W375–W385

    Article  PubMed  Google Scholar 

  17. Megibow AJ, Babb JS, Hecht EM et al. (2006) Evaluation of bowel distention and bowel wall appearance by using neutral oral contrast agent for multi-detector row CT. Radiology 238:87–95

    Article  PubMed  Google Scholar 

  18. Schindera ST, Nelson RC, DeLong DM et al. (2007) Multi-detector row CT of the small bowel: peak enhancement temporal window—initial experience. Radiology 243:438–444

    Article  PubMed  Google Scholar 

  19. Vandenbroucke F, Mortelé KJ, Tatli S, et al. (2007) Noninvasive multidetector computed tomography enterography in patients with small-bowel Crohn’s disease: is a 40-second delay better than 70 seconds? Acta Radiol Oct 23:1–9 [Epub ahead of print]

    Google Scholar 

  20. Huprich JE, Fletcher JG, Alexander JA et al. (2008) Obscure gastrointestinal bleeding: evaluation with 64-section multiphase CT enterography—initial experience. Radiology 246:562–571

    Article  PubMed  Google Scholar 

  21. Huprich J, Fletcher J, Fidler J, et al. (2007) A prospective comparison of multiphase CT enterography with wireless capsule endoscopy in the management of obscure GI bleeding. In:RSNA. Chicago, IL

  22. Scheffel H, Pfammatter T, Wildi S et al. (2007) Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT. Eur Radiol 17:1555–1565

    Article  PubMed  Google Scholar 

  23. Yoon W, Jeong YY, Shin SS et al. (2006) Acute massive gastrointestinal bleeding: detection and localization with arterial phase multi-detector row helical CT. Radiology 239:160–167

    Article  PubMed  Google Scholar 

  24. Vogel J, da Luz Moreira A, Baker M et al. (2007) CT enterography for Crohn’s disease: accurate preoperative diagnostic imaging. Dis Colon Rectum 50:1761–1769

    Article  PubMed  Google Scholar 

  25. Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284

    Article  PubMed  CAS  Google Scholar 

  26. Siddiki H, Fletcher J, Bruining D et al. (2007) Performance of lower-dose CT enterography for detection of inflammatory Crohn’s disease. In:RSNA. Chicago, IL

  27. McCollough CH, Bruesewitz MR, Kofler JM Jr (2006) CT dose reduction and dose management tools: overview of available options. Radiographics 26:503–512

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

Potential Conflicts of Interest: Grant support from Siemens Medical Solutions, E-E-Z-EM, Inc., and GE Healthcare; Educational License to GE Healthcare.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. G. Fletcher.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fletcher, J.G. CT enterography technique: theme and variations. Abdom Imaging 34, 283–288 (2009). https://doi.org/10.1007/s00261-008-9411-9

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00261-008-9411-9

Keywords

Navigation