Skip to main content
Log in

Retrieved total hip prostheses. Part I: The effects of cup thickness, head sizes and fusion defects on wear

  • Published:
Journal of Materials Science: Materials in Medicine Aims and scope Submit manuscript

Abstract

The effects of polyethylene cup thickness, femoral head sizes (22, 28 and 32 mm) and fusion defects on wear were investigated on retrieved total hip prostheses. When the cup thickness was less than 9 mm, the larger the femoral head, the higher the linear wear rate; however, when the cup thickness was more than 9 mm, the larger the femoral head, the linear wear rate was lower. When the cup thickness was less than 11 mm, the volumetric wear rate increased with increasing size of the femoral head, and when it was more than 11 mm, the volumetric wear rate of the three kinds of the prosthetic cups approached the same values. The wear rate of the cross-linked cups irradiated by 100 Mrad were very low, with no correlation to cup thickness. When the cup thickness was less than 9 mm, the volumetric wear rate tended to increase with increasing number of fusion defects. Large diameter fusion defects diminished the tensile strength.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. Charnley, A. Kamanger and M. Longfield, Med. Biol. Eng. 7 (1969) 31.

    Google Scholar 

  2. P. A. Revell, B. Weightman, M. A. R. Freeman and B. V. Roberts, Arch. Orthop. Traum. Surg. 91 (1978) 167.

    Google Scholar 

  3. H. Oonishi, Y. Takayama and E. Tsuji, Radiat. Phys. Chem. 39 (1992) 495.

    Google Scholar 

  4. J. M. Kabo, J. Bone Joint Surg. 75-B(2) (1993) 254.

    Google Scholar 

  5. J. Charnley and Z. Cupic, Clin. Orthop. 95 (1973) 9.

    Google Scholar 

  6. B. F. Morrey and D. Ilstrup, J. Bone Joint Surg. 71A (1989) 50.

    Google Scholar 

  7. H. Oonishi, H. Igaki and Y. Takayama, in “Transactions of the 3rd World Biomaterials Congress”, Kyoto, Japan, 21–25 April 1988, Vol. XI, p. 337.

    Google Scholar 

  8. H. Okumura, T. Yamamuro, T. Kumar and T. Nakamura, Bioceramics 1 (1989) 284.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Oonishi, H., Tsuji, E. & Kim, Y.Y. Retrieved total hip prostheses. Part I: The effects of cup thickness, head sizes and fusion defects on wear. Journal of Materials Science: Materials in Medicine 9, 393–401 (1998). https://doi.org/10.1023/A:1013283513509

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1013283513509

Keywords