Introduction

Peeling of the internal limiting membrane (ILM) of the retina during macular hole surgery may relieve tangential traction, and improve anatomical and functional outcomes.1 It is a technically demanding procedure, and many surgeons prefer to stain the membrane with indocyanine green (ICG) to provide contrast and facilitate peeling, resulting in high anatomical success rates.2, 3, 4, 5, 6 Recent clinical7, 8 and histopathological9, 10, 11 studies have suggested that ICG may be toxic to the retina. We assessed anatomical and functional results of ICG-assisted ILM peel for macular hole and attempted to identify potential factors that may affect the outcome of the procedure through a search of the literature.

Methods

A case note review was performed on 14 consecutive patients who had undergone vitrectomy, gas injection, and ICG-assisted peeling of the ILM for macular hole at the Royal Devon and Exeter Hospital between July 2001 and July 2002.

Thirteen patients underwent combined phacovitrectomy with clear lens extraction at the time of surgery, using self-sealing clear corneal incisions. The phacoemulsification was performed prior to vitrectomy, but the intraocular lens was not placed in the eye until the end of surgery. The remaining patient was pseudophakic. A standard three-port pars plana vitrectomy was performed under general anaesthesia. If no posterior vitreous detachment was present, the posterior vitreous face was separated using the cutter on suction mode held close to the optic disc. ICG solution (0.2–0.4 ml of 0.5%) was injected over the macula and left for 1–3 min before being aspirated. The ILM was then peeled in a circumferential manner around the macular hole to achieve an ILM defect of approximately two disc diameters.

Fluid–air exchange was followed by flushing with 50 ml of 20% C2F6 gas prior to closure of the sclerostomies. Patients were advised to posture face down if the gas fill was less than 70%, or if a stage 4 macular hole was present. If the gas fill was greater than 70%, no posture was required other than to avoid lying on their back for 10 days. The technique of routine phacovitrectomy without face-down posture has been described in a previous study.12

To prepare the ICG solution, 25 mg of sterile ICG powder was dissolved in 0.5 ml of sterile aqueous solvent. This was diluted in 4.5 ml of balanced salt solution, resulting in a 0.5% solution with an osmolarity of 270 mOsm. This concentration and method of preparation was advised by a facilitating consultant at an American Academy of Ophthalmology meeting in 2001.

Patients were reviewed at 2 weeks and 3 months after surgery (except for three patients, who were discharged after 2 months). Best-corrected visual acuities were recorded at discharge using a Snellen chart and converted to logMAR format. Patients had been refracted by an optometrist for final visual acuity measurement.

Results

Eight holes were stage 2, two stage 3, and three stage 4. A total of 12 patients were female, and the average age was 71 years (range 62–78 years). The mean duration of the macular hole prior to surgery was 7 months (range 2–18 months). ICG exposure time was 3 min for nine cases and 1 min for the other five. Three patients developed significant posterior capsular opacification requiring YAG capsulotomy.

Anatomical results

Of the 14 holes, 13 were flat and closed on follow-up examination, giving an anatomical success rate of 92.8%. The other hole remained elevated and open. Seven eyes (50%) developed macular pigmentary changes (Figures 3 and 4). No macular oedema was seen clinically following surgery with the fundal contact lens.

Figure 3
figure 3

Preoperative stage 3 full-thickness macular hole.

Figure 4
figure 4

Postoperative appearance with hole closure but pigmentary changes present.

Functional results

The mean preoperative acuity was 0.80. (range 0.60–1.30). The mean postoperative acuity was 0.77 (range 0.48–1.30). Of the 14 eyes, one improved by one line of Snellen visual acuity, three improved by two lines, and one improved by three lines. Three eyes were unchanged and six eyes reduced by 1 line of acuity (Figure 1). Of the seven eyes with macular pigment changes, three eyes reduced by one line of acuity, three remained the same, and one improved by two lines.

Figure 1
figure 1

Functional results.

The patients whose retinae were exposed to the ICG solution for only 1 min appeared to experience better functional outcomes (80% of patients had improved visual acuity) than those exposed for 3 min, of whom 11.1% improved (by only one line of acuity), 33.3% were unchanged, and 55.5% worsened (Figure 2). In addition, there was a higher rate of macular RPE changes in the group exposed for 3 min (six out of nine or 66.7%, compared with 20% for the group exposed for 1 min).

Figure 2
figure 2

Functional results by duration of ICG exposure.

Discussion

Tangential traction is believed to initiate macular holes, and may originate from collagen and cellular elements on either side of the ILM. The enlargement is thought to be due to myofibroblastic contraction on the ILM.1 The meta-analysis by Mester and Kuhn1 suggests that ILM peeling yields an anatomical success rate of 96% and a functional success rate (improvement of two or more lines of Snellen acuity) of 81%. This compares with figures of 77% and 55%, respectively, for surgery without ILM peeling from the same study.

ICG has been shown to selectively stain the ILM,2 and therefore facilitates identification of this very thin, transparent membrane for easier removal.2, 3, 4, 5, 6 However, recent studies have suggested less favourable functional results, and histopathologic analysis of operative9 and cell culture10, 11 specimens has suggested that ICG may be toxic to the retina. Our observations during this study support these findings.

Toxic effects of ICG may have increased significance as animal studies have suggested that it may pass along the length of the optic nerve by axonal transport after intravitreal injection.13 In addition, persistent fluorescence may be detected at the macula 3 months, and at the optic nerve 6 months after surgery.14

Possible basis for adverse effects of ICG

Toxic effects of ICG on the retinal pigment epithelium (RPE)

Evidence for ICG toxicity to the RPE has been seen in clinical and cell culture findings. Engelbrecht et al7 noted atrophic RPE changes in the area of the macular hole in 10 out of 21 eyes (47.6%). This is comparable with our findings of macular pigmentary changes in seven out of 14 eyes (50%). A much lower incidence of macular pigmentary changes (5.7%) was reported in a series of 105 eyes undergoing ILM peeling without ICG by Haritoglou et al.15 The postulated causes for this included impaired choroidal circulation due to gas tamponade, light toxicity, mechanical trauma, and suction of the subretinal fluid through the macular hole.

Studies involving RPE cell cultures have also demonstrated ICG toxicity. Increased cell death11 and reduced mitochondrial enzyme activity10 have been demonstrated in cultures exposed to ICG compared with those exposed to control solutions such as phosphate-buffered solution (PBS) or balanced salt solution (BSS). These changes relate to the clinical findings, as ICG comes in direct contact with the RPE through the macular hole during staining.

Induced damage to innermost retinal layers

Ultrastructural analysis (by electron microscopy) of ILM specimens removed during ICG-assisted surgery has revealed adherent cell membranes and even entire Muller cell foot processes, as well as other unidentified cell debris.8, 9 This is consistent with the subjective findings during this study that the ILM behaved differently and felt ‘thicker’ during peeling compared to surgery without ICG, suggesting a deeper cleavage plane.

Similar damage to the nerve fibre layer may explain the visual field defects reported by Haritoglou et al8 in 35% of eyes following ICG-assisted ILM peel, compared with no observed field defects in eyes undergoing unassisted ILM peel. However, other studies have reported small field defects following unassisted ILM peel,15 and also following macular hole surgery without ILM peel.1 Other possible causes include dehydration of nerve fibres during air-fluid exchange,1 trauma to the nerve fibre layer during ILM peel,8 and trauma to the optic nerve head during induced posterior vitreous detachment.

Technical factors that may alter adverse outcomes

Concentration of ICG used

Concentration may be the main factor influencing outcome of ICG-assisted ILM peel.7, 9 Concentrations seen in studies have varied by more than a factor of 20. Analysis of these studies suggests a correlation between higher concentrations and adverse outcomes, as shown in Table 1.

Table 1 Outcomes according to concentration of ICG used

Duration of ICG exposure prior to removal

If the adverse results are assumed to be due to toxicity of the ICG to the retina, it would seem logical that duration of exposure should also have an influence on the outcome. This is supported by Engelbrecht et al,7 who maintained a concentration of 0.1%, but varied the duration of exposure from 30 sec to 2½ min. While there was only a limited number of articipants in the study, there would seem to be a trend towards poorer functional outcome with longer exposures (Table 2).

Table 2 Outcomes according to duration of ICG exposure (Engelbrecht et al7)

These findings were supported by the current study, in which the results among eyes exposed for only 1 min were superior to those among eyes exposed for 3 min.

Further evidence of the toxicity of ICG can be seen by comparing outcomes with the product of concentration and time, as in Table 3.

Table 3 Outcomes according to product of concentration and time

Viscosity of the solution

Kandonosono et al4 used a viscomaterial to make up a 0.06% solution of ICG. This may be of importance, given the previous concern regarding direct contact of the solution with the RPE through the macular hole, which may be reduced or prevented by a more viscous solution.

Osmolarity of the solution

Stalmans et al11 demonstrated significantly increased cell death among cultured RPE cells exposed to hypo-osmolar solutions (including ICG) compared with cell cultures exposed to iso-osmolar (294–314 mOsm) solutions such as PBS. An analysis of other studies2, 6, 7, 8 reveals a correlation between functional outcome and osmolarity of solution used, with those using iso-osmolar solutions generally reporting better results. The exception was Kandonosono et al,4 who obtained good results with a hypo-osmolar solution (270 mOsm), but this had the possible aforementioned protective effect of viscosity.

Increased phototoxicity

Engelbrecht et al7 suggests that ICG may reduce the ‘safe time’ for light exposure to the macula. They suggest that this may be avoidable by reducing the light intensity during ILM peeling, and by ensuring a safe distance between the light source and the retina.

Conclusion

While ICG staining may facilitate ILM peeling during macular hole surgery, legitimate concerns have been raised regarding adverse functional outcomes from this technique. These concerns are supported by clinical and pathological findings following ICG use, including our present study. Further studies are required to determine whether a safe and effective technique of ICG staining of the ILM is possible through optimization of identified factors such as concentration, exposure time, phototoxicity, viscosity, and osmolarity of the solution.