Abstract
During global health emergencies such as the current COVID-19 pandemic, the decontamination of single-use personal protective equipment (PPE) becomes a necessary means to keep up with the growing demand from healthcare workers and patients alike. Many unverified methods are being considered, which can pose the risk of incomplete decontamination and lead to catastrophic results. Several factors come into play when determining the suitability of such methods including the quality of the decontamination technique, the targeted pathogen, cost, ease of installation and use, rate of sterilization, and the surface or material to be sterilized. The germicidal properties of ultraviolet-C are well known. This review will cover the most commonly described methods for the sterilization of N95 respirators, namely, ultraviolet germicidal irradiation, hydrogen peroxide vaporization, microwave-generated steaming, and dry heating. These techniques have been tested previously and have demonstrated efficacy in reducing or inactivating viral and bacterial pathogens, although testing against SARS-CoV-2 specifically has not been done. Moreover, it must be emphasized that proper disposal after a single use is still ideal under normal circumstances.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
U.S. Food and, Drug Administration Emergency Use Authorizations, https://www.fda.gov/medical-devices/emergency-situations-medical-devices/emergency-use-authorizations - covid19ppe, (accessed April 2020).
E. M. Fisher, J. L. Williams and R. E. Shaffer, PLoS One, 2011, 6, el8585.
N. van Doremalen, T. Bushmaker, D. H. Morris, M. G. Holbrook, A. Gamble, B. N. Williamson, A. Tamin, J. L. Harcourt, N. J. Thornburg, S. I. Gerber, J. O. Lloyd-Smith, E. de Wit and V. J. Munster, N. Engl. J. Med., 2020, DOI: 10.1056/NEJMC2004973.
W. G. Lindsley, S. B. Martin Jr., R. E. Thewlis, K. Sarkisian, J. O. Nwoko, K. R. Mead and J. D. Noti, J. Occup. Environ. Hyg., 2015, 12, 509–517.
N. G. Reed, Public Health Rep., 2010, 125, 15–27.
B. Casini, B. Tuvo, M. L. Cristina, A. M. Spagnolo, M. Totaro, A. Baggiani and G. P. Privitera, Int. J. Environ. Res. Public Health, 2019, 16, 1–10.
A. Guridi, E. Sevillano, I. de la Fuente, E. Mateo, E. Eraso and G. Quindos, Int. J. Environ. Res. Public Health, 2019, 16, 1–11.
J. H. Yang, U. I. Wu, H. M. Tai and W. H. Sheng, J. Microbiol., Immunol. Infect., 2019, 52, 487–493.
A. J. K. Pefoyo, S. E. Bronskill, A. Gruneir, A. Calzavara, K. Thavorn, Y. Petrosyan, C. J. Maxwell, Y Bai and W. P. Wodchis, BMC Public Health, 2015, 15, 415–415.
W. Szeto, W. C. Yam, H. Huang and D. Y C. Leung, BMC Infect. Dis., 2020, 20, 1–9.
I. H. Hamzavi, A. B. Lyons, I. Kohli, S. Narla, A. Parks-Miller, J. M. Gelfand, H. W. Lim and D. Ozog, J.. Am. Acad. Dermatol, 2020, DOI: 10.1016/j.jaad.2020.03.085.
J. Kim and J. Jang, Aerosol Sci. Technol, 2018, 52, 557–566.
D. K. Kim and D. H. Kang, Appl. Environ. Microbiol, 2018, 84, 1–11.
K. Song, F. Taghipour and M. Mohseni, Sci. Total Environ., 2019, 665, 1103–1110.
P. O. Nyangaresi, Y Qin, G. Chen, B. Zhang, Y Lu and L. Shen, Water Res., 2019, 157, 218–227.
K. Song, M. Mohseni and F. Taghipour, Water Res., 2019, 163, DOI: 10.1016/j.watres.2019.114875.
S. S. Nunayon, H. Zhang and A. C. K. Lai, Indoor Air, 2020, 30, 180–191.
T. H. Lin, F. C. Tang, P. C. Hung, Z. C. Hua and C. Y Lai, Indoor Air, 2018, 28, 754–762.
D. Mills, D. A. Harnish, C. Lawrence, M. Sandoval-Powers and B. K. Heimbuch, Am. J. Infect. Control, 2018, 46, e49–e55.
E. M. Fisher and R. E. Shaffer, J. Appl. Microbiol, 2011,110, 287–295.
D. Mills, M. Sandoval, C. Lawrence, B. Heimbuch and D. Harnish, Ultraviolet Germicidal Irradiation of Influenza-Contaminated N95 Filtering Facepiece Respirators. American Society for Microbiology Poster Presentation 2016, https://www.fda.gov/downloads/EmergencyPreparedness/Counterterrorism/MedicalCountermeasures/MCMRegulatory Science/UCM505730.pdf (accessed April 2020).
K. Bedell, A. H. Buchaklian and S. Perlman, Infect. Control Hosp. Epidemiol, 2016, 37, 598–599.
F. Memarzadeh, R. N. Olmsted and J. M. Bartley, Am. J. Infect. Control, 2010, 38, S13–S24.
C. C. Tseng and C. S. Li, J. Occup. Environ. Hyg., 2007, 4, 400–405.
M. Lindblad, E. Tano, C. Lindahl and F. Huss, Burns, 2019, DOI: 10.1016/j.burns.2019.10.004.
S. Narla, A. B. Lyons, I. Kohli, A. E. Torres, A. Parks-Miller, D. M. Ozog, I. H. Hamzavi and H. W. Lim, Photodermatol., Photoimmunol. Photomed., 2020, 1–2.
A. Fraise, J. Y Maillard and S. Sattar, Russell, Hugo & Ayliffe’s Principles and Practice of Disinfection, Preservation and Sterilization, Wiley-Blackwell, United Kingdom, 5th edn, 2013.
J. Halamka and J. Schnitzer, COVID-19 Healthcare Coalition N95 Working Group Evaluation of Decontamination Techniques for the Reuse of N95 Respirators, https://c19hcc.org/static/img/insights/Evaluation-of-Respirator-Decontamination-Techniques.pdf, (accessed April 1, 2020).
W. A. Rutala, M. F. Gergen and D. J. Weber, Infect. Control Hosp. Epidemiol, 2012, 33, 1159–1161.
D. J. Weber, H. Kanamori and W. A. Rutala, Curr. Opin. Infect. Dis., 2016, 29, 424–431.
S. Ali, S. Yui, M. Muzslay and A. P. R. Wilson, J. Hosp. Infect., 2018, 98, 438–439.
T. Y. Fu, P. Gent and V. Kumar, J. Hosp. Infect., 2012, 80, 199–205.
E. Tuladhar, P. Terpstra, M. Koopmans and E. Duizer, J. Hosp. Infect., 2012, 80, 110–115.
A. Schwartz, M. Stiegel, N. Greeson, A. Vogel, W. Thomann, M. Brown, G. D. Sempowski, T. S. Alderman, J. P. Condreay, J. Burch, C. Wolfe, B. Smith and S. Lewis, Appl. Biosaf., 2020, 25, 67–70.
Battelle CCDS Critical Care Decontamination System, https://www.battelle.org/docs/default-source/commercial-offerings/industry-solutions/732_battelle-critical-care-decon-system_technical-summaryf.pdf, (accessed April 2020).
B. K. Heimbuch, W. H. Wallace, K. Kinney, A. E. Lumley, C. Y. Wu, M. H. Woo and J. D. Wander, Am. J. Infect. Control, 2011, 39, e1–e9.
M. B. Lore, B. K. Heimbuch, T. L. Brown, J. D. Wander and S. H. Hinrichs, Ann. Occup. Hyg., 2012, 56, 92–101.
H. F. Rabenau, J. Cinatl, B. Morgenstern, G. Bauer, W. Preiser and H. W. Doerr, Med. Microbiol. Immunol., 2005, 194, 1–6.
D. J. Viscusi, M. S. Bergman, B. C. Eimer and R. E. Shaffer, Ann. Occup. Hyg., 2009, 53, 815–827.
T. H. Lin, C. C. Chen, S. H. Huang, C. W. Kuo, C. Y Lai and W. Y Lin, PLoS One, 2017, 12, e0186217.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Torres, A.E., Lyons, A.B., Narla, S. et al. Ultraviolet-C and other methods of decontamination of filtering facepiece N-95 respirators during the COVID-19 pandemic. Photochem Photobiol Sci 19, 746–751 (2020). https://doi.org/10.1039/d0pp00131g
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1039/d0pp00131g