Factors influencing uncertainties of in vivo bone lead measurement using a 109Cd K X-ray fluorescence clover leaf geometry detector system

Abstract

A 109Cd K X-ray fluorescence (KXRF) measurement system consisting of four detectors in clover-leaf geometry is a non-invasive, low-radiation-dose method of measuring bone lead concentration. Its high precision in estimating the bone lead content makes it a promising tool for the determination of the low levels of lead currently found in the general population. After developing the clover-leaf geometry system, the system was used for the first time in a major survey in 2008 to measure the lead levels of 497 smelter employees (an occupationally exposed group with high lead levels). Since the delivered effective dose of the bone lead system in clover-leaf geometry is small (on the order of nSv), the technique can be used to measure the bone lead of sensitive populations such as the elderly and children. This detector system was used from 2009 to 2011, in a pilot study that measured the bone lead concentration of 263 environmentally exposed individuals (termed the EG group) residing in Toronto, Ontario, Canada. In this paper, the factors that influence uncertainties in lead content in tibia (cortical bone) and calcaneus (trabecular bone) are discussed based on gender, age, and body mass index (BMI) by using analysis of variance (ANOVA) and multiple linear regression models. Results from the two study groups (the EG group versus the occupationally exposed smelter employees) are compared where appropriate (i.e. for males older than 20). Results from univariate analyses showed that females have higher tibia uncertainty compared to males. We observed significant differences for both calcaneus and tibia uncertainty measures (p < 0.0005) among different age groups, where the uncertainties were highest in the lowest age group (<11 years). Lastly, and perhaps most significantly, we found that the product of source activity and measurement time influenced the precision of measurements greatly, and that this factor alone could account for the higher uncertainties observed for the male cohort of the EG group versus the smelter employees.

Graphical abstract: Factors influencing uncertainties of in vivo bone lead measurement using a 109Cd K X-ray fluorescence clover leaf geometry detector system

Supplementary files

Article information

Article type
Paper
Submitted
12 Aug 2014
Accepted
06 Oct 2014
First published
16 Oct 2014

Environ. Sci.: Processes Impacts, 2014,16, 2742-2751

Factors influencing uncertainties of in vivo bone lead measurement using a 109Cd K X-ray fluorescence clover leaf geometry detector system

S. Behinaein, D. R. Chettle, L. Marro, M. Malowany, M. Fisher, D. E. B. Fleming, N. Healey, M. Inskip, T. E. Arbuckle and F. E. McNeill, Environ. Sci.: Processes Impacts, 2014, 16, 2742 DOI: 10.1039/C4EM00446A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements