28 May 1999 Experimental and theoretical spectral optimization for digital mammography
Vaidehi Venkatakrishnan, Mehmet Yavuz, Loren T. Niklason, Beale Opsahl-Ong, Sung S. Han, Cynthia Landberg, Robert L. Nevin, Leena Hamberg, Daniel B. Kopans
Author Affiliations +
Abstract
The detection characteristics of digital x-ray and film-screen mammography systems are different and thus current film-screen techniques are not ideal for digital mammography. Therefore optimum technical parameters required for digital mammography are likely to be different compared with film-screen mammography. The goal of this study is to evaluate the optimum technical parameters for full-field digital mammography by experimental and computer simulation methods. A General Electric Full Field Digital Mammography (FFDM) prototype unit using Cesium Iodide (CsI) on an amorphous Silicon photodiode array was used for the experimental measurements. Using breast equivalent phantoms, images were acquired for a set of x-ray target-filters for a range of peak kilovoltage, varying breast composition and thickness, with and without an anti-scatter grid. The signal-to-noise ratio (SNR) and figure-of-merit (FOM) were determined for simulated calcification and mass targets, independently by the two methods. The results for noise, contrast, SNR and FOM were compared and agree within 5% and 6% respectively. Combined results are presented for the case of 50% glandular - 50% adipose tissue breast composition using the grid and for the calcification target. Based on the FOM approach, preliminary results suggest that a Rhodium target-filter combination will be beneficial for higher breast thickness and for denser breasts.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vaidehi Venkatakrishnan, Mehmet Yavuz, Loren T. Niklason, Beale Opsahl-Ong, Sung S. Han, Cynthia Landberg, Robert L. Nevin, Leena Hamberg, and Daniel B. Kopans "Experimental and theoretical spectral optimization for digital mammography", Proc. SPIE 3659, Medical Imaging 1999: Physics of Medical Imaging, (28 May 1999); https://doi.org/10.1117/12.349487
Lens.org Logo
CITATIONS
Cited by 14 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Digital mammography

Breast

Signal to noise ratio

Mammography

Sensors

X-rays

Molybdenum

Back to Top