20 April 2005 Quantifying the performance of human and software CDMAM phantom image observers for the qualification of digital mammography systems
Author Affiliations +
Abstract
The growing importance of the “European Protocol for the Quality Control of the Physical and Technical Aspects of Mammography Screening, Part B: Digital Mammography” dictates the need to understand the prescribed threshold contrast sensitivity test. Observers following a 4-AFC paradigm, report the location of disks varying in contrast and diameter on multiple images of a CDMAM or similar phantom. Analysis provides a contrast threshold for each disk diameter. The goals of this study were to quantify the performance of new observers, compare it to published results, compare visual scoring with software scoring of the same images, and to quantify the major sources of variability. Digital phantom images, visual scorings by four expert readers, and CDCOM software were downloaded from the EUREF website. These images were read on a 3M Barco flat-panel monitor by 13 observers and scored by CDCOM. Scores were analyzed using the published method from the CDMAM-phantom 3.4 manual and a signal detection theory-based method. The average contrast sensitivities of the 13 study observers generally exceeded the published values by ~10%. The 95% confidence limits for the mean of 6 images from the published data vary from ±20.2% to ±41.8% of their respective means, the average being 31.2%. The average confidence limit for selected study observers is ±36%. Comparisons between software and human observer results using the prescribed method of analysis-revealed marked differences, particularly for small diameter targets. These differences are mitigated by signal-detection-theory analysis of both datasets. The large inter-observer variability and the substantial time required for human scoring supports the need to qualify a readily available software solution.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lynn Fletcher-Heath and Richard Van Metter "Quantifying the performance of human and software CDMAM phantom image observers for the qualification of digital mammography systems", Proc. SPIE 5745, Medical Imaging 2005: Physics of Medical Imaging, (20 April 2005); https://doi.org/10.1117/12.595510
Lens.org Logo
CITATIONS
Cited by 23 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Visualization

Statistical analysis

Electronic design automation

Visual analytics

Digital mammography

Error analysis

Data modeling

Back to Top