Abstract
An automated high performance liquid chromatography with column-switching and ultraviolet detection was developed for the analysis of risperidone and 9-hydroxyrisperidone. The method needs minimum sample preparation and is useful for the detection down to a limit of 1 ng mL−1. Sample clean-up of serum was carried out on a CN 20 μm SPE-column using 8% (v/v) acetonitrile in water. Chromatographic separation was performed on ODS Hypersil C18 material with 38% (v/v) acetonitrile and 0.4% (v/v) TEMED in water. Application of the method to the analysis of serum samples confirmed its suitability for therapeutic drug monitoring of risperidone and 9-hydroxyrisperidone.
Similar content being viewed by others
References
Janssen PA, Niemegeers CJ, Awouters F, Schellekens KH, Megens AA, Meert TF (1988) J Pharmacol Exp Ther 244:685–693
Huang ML, Van Peer A, Woestenborghs R, De Coster R, Heykants J, Jansen AA, Zylicz Z, Visscher HW, Jonkman JH (1993) Clin Pharmacol Ther 54:257–268
Van Beijsterveldt LE, Geerts RJ, Leysen JE, Megens AA, Van den Eynde HM, Meuldermans WE, Heykants JJ (1994) Psychopharmacology 114:53–62
Baumann P, Hiemke C, Ulrich S, Eckermann G, Gaertner I, Gerlach M, Kuss HJ, Laux G, Muller-Oerlinghausen B, Rao ML, Riederer P, Zernig G (2004) Pharmacopsychiatry 37:243–265
Balant-Gorgia AE, Gex-Fabry M, Genet C, Balant LP (1999) Ther Drug Monit 21:105–115
Aravagiri M, Marder SR, Wirshing D, Wirshing WC (1998) Pharmacopsychiatry 31:102–109
Woestenborghs R, Lorreyne W, Van Rompaey F, Heykants J (1992) J Chromatogr 583:223–230
Olesen OV, Linnet K (1997) J Chromatogr B Biomed Sci Appl 698:209–216
Le Moing JP, Edouard S, Levron JC (1993) J Chromatogr 614:333–339
Moody DE, Laycock JD, Huang W, Foltz RL (2004) J Anal Toxicol 28:494–497
Aravagiri M, Marder SR (2000) Mass Spectrom 35:718–724
Flarakos J, Luo W, Aman M, Svinarov D, Gerber N, Vouros P (2004) J Chromatogr A 1026:175–183
Kousoulos C, Dotsikas Y, Loukas YL (2007) Talanta 72:360–367
Clinical and Laboratory Standards Institute (CLSI) (1992) Evaluation of precision performance of clinical chemistry devices. NCCLS/CLSI Document EP5–T2. CLSI, Wayne
Kane J, Canas F, Kramer M, Ford L, Gassmann-Mayer C, Lim P, Eerdekens M (2007) Schizophr Res 90:147–161
Acknowledgments
We thank Sandra Heller for skilful technical assistance and Janssen–Cilag (Beerse, Belgium) for kindly supplying us with 9-hydroxyrisperidone pure drug substance.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kirschbaum, K.M., Finger, S., Vogel, F. et al. LC with Column-Switching and Spectrophotometric Detection for Determination of Risperidone and 9-Hydroxyrisperidone in Human Serum. Chroma 67, 321–324 (2008). https://doi.org/10.1365/s10337-007-0506-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1365/s10337-007-0506-1