Abstract
The problem of indoor mold infestation is actually of growing concern in the evaluation and sanitation of water damages in buildings. Such damage may be caused by high humidity levels during living, condensation due to insufficient insulation or water penetration by leakages in piping or flooding hazards.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
AIHA (2001) Report of microbial growth task force. American Industrial Hygiene Association, Fairfax, VA, USA.
AIHA (2004) Assessment, remediation, and post-remediation verification of mold in buildings. American Industrial Hygiene Association, Fairfax, VA, USA.
Andersen B, Nielsen KF and Jarvis BB (2002) Characterization of Stachybotrys from water-damaged buildings based on morphology, growth and metabolic production. Mycoligia 94: 392–403.
Baudisch C and Kramer A (2006) Quantitative Bestimmung von Aspergillus- und Penicillium- arten in der 63 μm Hausstaubfraktion. In: Keller R, Senkpiel K, Samson RA and Hoekstra ES (eds.) Partikuläre und molekulare Belastungen der Innenraum- und Außenluft, Band 10. Verlag Schmidt Römhild, Lübeck, Germany, pp. 59–85.
BG Bau – Berufsgenossenschaft der Bauwirtschaft (2006) Handlungsanleitung: Gesundheitsgefährdungen durch biologische Arbeitsstoffe bei der Gebäudesanierung (BGI 858). Fachausschuß Tiefbau, Berlin, Germany.
BG Bau – Berufsgenossenschaft der Bauwirtschaft (2006) Richtlinie “Kontaminierte Bereiche” (BGR 128), Fachausschuß Tiefbau, Berlin.
EPA (2001) Mold remediation in schools and commercial buildings. U.S. Environmental Protection Agency, EPA 402-K-01–001, Washington, DC, USA.
EPA (2002) A brief guide to mold, moisture, and your home. U.S. Environmental Protection Agency, EPA 402-K-02–003, Washington, DC, USA.
Fischer G and Dott W (2005) Die Relevanz von sekundären Stoffwechselprodukten (MVOC, Mykotoxine) von Schimmelpilzen für die Innenraumhygiene. Umweltmed Forsch Prax 10: 329.
Fischer G, Möller M, Gabrio T, Palmgren U, Keller R, Richter H, Dott W and Raul R (2005) Vergleich der Messverfahren zur Bestimmung von MVOC in Innenräumen. Bundesgesundheitsbl — Gesundheitsforsch — Gesundheitsschutz 48: 43–53.
Gabrio T, Weidner U and Seidl HP (2007) Schimmelpilze in Innenräumen – Nachweis, Bewertung, Qualitätsmanagement – Auswertung der bisher durchgeführten Ringversuche unter besonderer Berücksichtigung des 10. und 11. Ringversuchs. In: Fortbildung Ringversuch “Schimmelpilze”. München, Germany.
Haas D, Habib J, Schlacher R, Unteregger M, Galler H, Buzina W, Marth E and Reinthaler FF (2005) Einfluss des Schimmelbefalls in Innenräumen auf die Sporenzahl der Raumluft. Umweltmed Forsch Prax 10: 328.
Health Canada (2004) Fungal contamination in public buildings: health effects and investigation methods. Health Canada H46-2/04–358E, Ottawa, Canada.
Hicks JB, Lu ET, De Guzman R and Weingart M (2005) Fungal types and concentrations from settled dust in normal residences. J Occup Environ Hyg 2: 481–492.
Keller R, Reinhardt-Benitez S, Döringer K, Eilers J, Laußmann D, Mergener H-J, Ohgke H, Schmidt A, Senkpiel K, Solbach W, Wlaker G, Weiß R and Butte W (2004) Hintergrundwerte von flüchtigen Schimmelpilzmetaboliten in unbelasteten Wohngebäuden. Gefahrstoffe — Reinhaltung der Luft 64: 187–190.
Lacey J (1997) Fungi and actinomycetes as allergens. In: Kay AB (ed.) Allergy and allergenic diseases, Blackwell Scientific Publications, Oxford, UK, pp. 858–887.
LGA–Landesgesundheitsamt Baden-Württemberg (2001) Schimmelpilze in Innenräumen – Nachweis, Bewertung, Qualitätsmanagement. Landesgesundheitsamt Baden-Württemberg, Stuttgart, Germany.
LGA – Landesgesundheitsamt Baden-Württemberg (2004) Handlungsempfehlung für die Sanierung von mit Schimmelpilzen befallenen Innenräumen, Leitfaden, Landesgesundheitsamt Baden-Württemberg, Stuttgart, Germany.
Lorenz W, Hankammer G and Lassl K (2005) Sanierung von Feuchte- und Schimmelpilzschäden – Diagnose, Planung und Ausführung. Rudolf Müller Verlag, Köln, Germany.
Lorenz W, Trautmann C, Dill A, Mehrer (2003) Bakterielle Verunreinigungen in Innenräumen III — 4.3.2. In: Moriske H-J and Turowski E (eds.) Handbuch für Bioklima und Lufthygiene 10 Erg. Lfg. Ecomed, Landsberg, Germany.
Moriske H-J (2005) 12. WaBoLu — Innenraumtage vom 2.-4. Mai 2005 — Mikrobielle und chemische Verunreinigungen. Bundesgesundheitsbl — Gesundheitsforsch — Gesundheitsschutz 48: 1296–1303.
Nielsen KF, Holm G, Uttrup LP and Nielsen PA (2004) Mold growth on building materials under low water activities — influence of humidity and temperatureon fungal growth and secondary metabolism. Int Biodeter Biodeg 54: 325–336.
NYC (1993) Guidelines on assessment and remediation of Stachybotrys atra in indoor environments. New York City Department of Health, New York City Human Resources Administration, and Mount Sinai – Irving J. Selikoff Occupational Health Clinical Center, New York, NY, USA.
NYC (2000) Guidelines on assessment and remediation of mold in indoor environments, New York City Department of Health, New York, NY, USA.
NYC (2008), Guidelines on assessment and remediation of fungi in indoor environments, New York City Department of Health and Mental Hygiene, New York, NY, USA.
Oswald R (2003) Schimmelpilzbewertung aus der Sicht des Bausachverständigen. In: 29. Aachener Bausachverständigentage 2003. Leckstellen in Bauteilen; Wärme — Feuchte — Luft — Schall. Vieweg, Wiesbaden, Germany, pp. 120–126.
Oswald R (2004) Schwachstellen – “Die Schimmelspürhund-Unauffälligkeit” — eine wesentliche Eigenschaft von Gebäuden? Deutsch Bauz 9: 85–88.
Peltola J, Anderssen MA, Haahtela T, Mussalo-Rauhamaa H, Rainey FA, Kroppenstedt RM, Samson RA and Salkinoja-Salonen MS (2001) Toxic-metabolite-producing bacteria and fungus in an indoor environment. Appl Environ Microbiol 67: 3269–3274.
Pessi A-M, Suonketo J, Pentti M, Kurkilahti M, Peltola K and Rantio-Lehtimäki (2002) Microbial growth inside insulated external walls as an indoor air biocontamination source. Appl Environ Microbiol 68: 963–967.
Richardson N (2004) Orientierungshilfen zur Bewertung von Schimmelpilzbefall im Fußbodenaufbau. In: 8. Pilztagung des VDB — Berufsverband Deutscher Baubiologen, VDB, Jesteburg, Germany, pp. 125–136.
Schleibinger H, Laußmann D, Eis D, Samwer H and Rüden H (2004) Sind MVOC geeignete Indikatoren für einen verdeckten Schimmelpilzbefall? Umweltmed Forsch Prax 9: 151–162.
Trautmann C (2005) Aussagekraft von Schimmelpilzuntersuchungen. In: 9. Pilztagung des VDB — Berufsverband Deutscher Baubiologen, VDB, Jesteburg, Germany, pp. 17–32.
Trautmann C (2006) Nachweis und Bewertung von non-viable Sporen im Innenraum In: Keller R, Senkpiel K, Samson RA und Hoekstra ES (eds.) Partikuläre und molekulare Belastungen der Innenraum- und Außenluft, Band 10. Verlag Schmidt Römhild, Lübeck, Germany, pp. 315–332.
Trautmann C, Gabrio T, Dill I and Weidner U (2005b) Hintergrundkonzentrationen von Schimmelpilzen in Hausstaub. Bundesgesundheitsbl — Gesundheitsforsch — Gesundheitsschutz 48: 29–35.
Trautmann C, Gabrio T, Dill I, Weidner U and Baudisch C (2005a) Hintergrundkonzentration von Schimmelpilzen in Luft. Bundesgesundheitsbl — Gesundheitsforsch — Gesundheitsschutz 48: 12–20.
Tuomi T, Reijula K, Johnsson T, Hemminki K, Hintikka E-L, Lindroos O, Kalso S, Koukila-Kähkölä P, Mussalo-Rauhamaa H and Haahtela T (2000) mycotoxins in crude building materials from water-damaged buildings. Appl Environ Microbiol 66: 1899–1904.
UBA – Umweltbundesamt (2002) Leitfaden zur Vorbeugung, Untersuchung, Bewertung und Sanierung von Schimmelpilzwachstum in Innenräumen. Umweltbundesamt Berlin, Berlin, Germany.
UBA – Umweltbundesamt (2005) Leitfaden zur Ursachensuche und Sanierung bei Schimmelpilzwachstum in Innenräumen (“Schimmelpilzsanierungsleitfaden”). Umweltbundesamt Berlin, Berlin, Germany.
VDI – Verein Deutscher Ingenieure (2008) Messen von Innenraumluftverunreinigungen – Messstrategien bei der Untersuchung von Schimmelpilzen in Innenräumen VDI 4300 Bl. 10. VDI, Düsseldorf, Germany.
Virnisch L, Lorenz W and Trautmann C (2003) MVOC aus neuen Materialien. Z Umweltmed 4: 180–183.
Warscheid T (1996) Biodeterioration of stones: analysis, quantification and evaluation. In: Proceedings of the 10th International Biodeterioration and Biodegradation Symposium, Dechema, Monograph 133, Frankfurt, Germany, pp. 115–120.
Warscheid Th (2003) The evaluation of biodeterioration processes on cultural objects and respective approaches for their effective control. In: Koestler RJ, Koestler VH, Charola AE and Nieto-Fernandez FE (eds.) Art, biology, and conservation 2002: Biodeterioration of works of art. The Metropolitan Museum of Art, New York, NY, USA, pp. 14–27.
Warscheid Th (2007) Wandbaustoffe aus Kalk ein natürlicher Schutz gegen Schimmelpilzbildung in Innenräumen. Der Bausachverständige 1: 11–16.
Warscheid Th (2008) Mikrobielle Belastungen in Estrichen im Zusammenhang mit Wasserschäden. In: Osward R (ed.) 33. Aachener Bausachverständigentage 2007. Bauwerksabdichtungen: Feuchteprobleme im Keller und Gebäudeinneren. Vieweg+Theubner, Wiesbaden, Germany.
Warscheid Th and Braams J (2000) Biodeterioration of stones — a review. Int Biodeterior Biodegr 46: 343–368.
Witt A and Krause S (2007) Nachweis von Bauholz- und Schimmelpilzen mittels DNA-Diagnostik. Der Bausachverständige 3: 24–26.
Wouters IM, Douwes J, Doekes G, Torne PS, Brunekreef B and Heederik DJJ (2000) Increased levels of markers of microbial exposure in homes with indoor storage of organic household waste. Appl Environ Microbiol 66: 627–631.
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2011 Wageningen Academic Publishers
About this chapter
Cite this chapter
Warscheid, T. (2011). Mold remediation in West-European buildings. In: Adan, O.C.G., Samson, R.A. (eds) Fundamentals of mold growth in indoor environments and strategies for healthy living. Wageningen Academic Publishers, Wageningen. https://doi.org/10.3920/978-90-8686-722-6_15
Download citation
DOI: https://doi.org/10.3920/978-90-8686-722-6_15
Publisher Name: Wageningen Academic Publishers, Wageningen
Online ISBN: 978-90-8686-722-6
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)