Am J Perinatol 2009; 26(4): 287-289
DOI: 10.1055/s-0028-1103157
© Thieme Medical Publishers

A Successful Pregnancy Outcome following the Ross Procedure: A Case Report

Unzila Ali1 , Joshua Copel1 , Alan Friedman2
  • 1Obstetrics, Gynecology, and Reproductive Sciences, Yale University, New Haven, Connecticut
  • 2Pediatrics, Yale University, New Haven, Connecticut
Further Information

Publication History

Publication Date:
08 December 2008 (online)

ABSTRACT

For women requiring valve replacement surgery, it is unclear which type of valve offers the greatest chance of a healthy pregnancy. This case describes a successful pregnancy outcome following the Ross procedure, which involves replacing the aortic valve with an autologous pulmonary valve. Due to left ventricular outflow tract obstruction, this patient required an aortic valve replacement surgery. She underwent the Ross procedure at age 16 and became pregnant 11 years later. During pregnancy, she was able to avoid the risks of anticoagulation. She underwent an assisted second stage of labor and went on to deliver a healthy infant. This case illustrates that the Ross procedure may be an alternative treatment for aortic valve replacements in women of child-bearing age.

REFERENCES

  • 1 Hall J G, Pauli R M, Wilson K M. Maternal and fetal sequelae of anticoagulation during pregnancy.  Am J Med. 1980;  68 122-140
  • 2 Ross D N. Replacement of aortic and mitral valves with a pulmonary autograft.  Lancet. 1967;  2 956-958
  • 3 Earing M G, Webb G D. Congenital heart disease and pregnancy: maternal and fetal risks.  Clin Perinatol. 2005;  32 913-919
  • 4 North R A, Sadler L, Stewart A W et al.. Long-term survival and valve-related complications in young women.  Circulation. 1999;  99 2669-2676
  • 5 Chan W S, Anand S, Ginsberg J S. Anticoagulation of pregnant women with mechanical heart valves: a systematic review of the literature.  Arch Intern Med. 2000;  160 191-196
  • 6 Lee C N, Wu C C, Lin P Y et al.. Pregnancy following cardiac prosthetic valve replacement.  Obstet Gynecol. 1994;  83 353-356
  • 7 Hammermeister K, Sethi G K, Henderson W G et al.. Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trial.  J Am Coll Cardiol. 2000;  36 1152-1158
  • 8 Vongpatanasin W, Hillis L D, Lange R A. Prosthetic heart valves.  N Engl J Med. 1996;  335 407-416
  • 9 Sbarouni E, Oakley C M. Outcome of pregnancy in women with valve prostheses.  Br Heart J. 1994;  71 196-201
  • 10 Ross D, Jackson M, Davies J. The pulmonary autograft- a permanent aortic valve.  Eur J Cardiothorac Surg. 1992;  6 113-116
  • 11 Elkins R C. The Ross operation: a 12-year experience.  Ann Thorac Surg. 1999;  68 S14-S18
  • 12 Elkins R C, Santangelo K, Randolph J D et al.. Pulmonary autograft replacement in children. The ideal solution?.  Ann Surg. 1992;  216 363-370
  • 13 Dore A, Somerville J. Pregnancy in patients with pulmonary autograft valve replacement.  Eur Heart J. 1997;  18 1659-1662
  • 14 Martin T C, Idahosa V, Ogynbiyi A, Fevrier-Roberts G, Winter A. Successful pregnancy and delivery after pulmonary autograft operation (Ross procedure) for rheumatic aortic valve insufficiency.  West Indian Med J. 2003;  52 62-64

Unzila AliM.D. 

Yale University

P.O. Box 208063, New Haven, Connecticut 06520-8063

Email: unzila.ali@yale.edu

    >