Skip to main content
Erschienen in: International Ophthalmology 1/2024

01.12.2024 | Original Paper

Comparison of comfort and tear stability with two novel silicone-hydrogel daily disposable contact lenses

verfasst von: Tatsuya Mimura, Hidetaka Noma, Masao Yamaguchi, Koichiro Shinbo

Erschienen in: International Ophthalmology | Ausgabe 1/2024

Einloggen, um Zugang zu erhalten

Abstract

Background

The surface wettability of soft contact lenses (SCLs) affects the wearing comfort. Verofilcon A is a daily disposable silicone hydrogel contact lens with SMARTSURFACE® technology, ensuring high surface wettability.

Purpose

To evaluate tear stability on the surface of verofilcon A and narafilcon A SCLs and correlate these findings with clinical parameters and patients' discomfort.

Methods

Sixty-two SCL wearers (124 eyes) with SCL discomfort were randomly assigned to use narafilcon A (control SCL) and verofilcon A for 2 weeks each by crossover. The noninvasive tear break-up time (NIBUT) of the naked eye at baseline and pre-lens NIBUT (PL-NIBUT) of the SCL surface after 2 weeks of using each SCL were measured using the DR-1α® dry eye observation device. Corneal superficial punctate keratopathy (SPK) (0–3) and conjunctival hyperemia (0–3), and comfort level of SCL wear (1–10) were also evaluated.

Results

NIBUT and PL-NIBUT values were 4.6 ± 2.3 s for the naked eye, 6.6 ± 6.6 s for narafilcon A, and 11.3 ± 3.5 s for verofilcon A. verofilcon A had significantly higher PL-NIBUT than the naked eye and narafilcon A (p < 0.05). SPK (0.16 ± 0.48 vs. 0.00 ± 0.00, p < 0.01) and conjunctival hyperemia (1.15 ± 0.82 vs. 0.49 ± 0.50, p < 0.01) scores were lower when wearing verofilcon A than narafilcon A. The ocular comfort score of wearing SCLs was higher with verofilcon A than with narafilcon A (8.7 ± 1.8 vs. 9.8 ± 0.5, p < 0.01). The ocular comfort score for wearing verofilcon A was higher, regardless of the baseline NIBUT.

Conclusion

The results of this study showed a consistent surface-wetting advantage of verofilcon A in patients with ocular discomfort. verofilcon A was used comfortably in patients with low NIBUT scores at baseline. The findings suggest that verofilcon A is recommended for SCL wearers experiencing SCL-related dry eye symptoms and discomfort.
Literatur
4.
Zurück zum Zitat Dumbleton K, Caffery B, Dogru M, Hickson-Curran S, Kern J, Kojima T, Morgan PB, Purslow C, Robertson DM, Nelson JD, members of the TFOS International Workshop on Contact Lens Discomfort 2013 The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on epidemiology. Invest Ophthalmol Vis Sci 54(11):TFOS20-36. https://doi.org/10.1167/iovs.13-13125 Dumbleton K, Caffery B, Dogru M, Hickson-Curran S, Kern J, Kojima T, Morgan PB, Purslow C, Robertson DM, Nelson JD, members of the TFOS International Workshop on Contact Lens Discomfort 2013 The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on epidemiology. Invest Ophthalmol Vis Sci 54(11):TFOS20-36. https://​doi.​org/​10.​1167/​iovs.​13-13125
11.
Zurück zum Zitat Fogt JS, Menner A, Patton K (2022) Evaluation of wear experience with water surface daily disposable lenses in satisfied reusable soft contact lens wearers. J Contact Lens Res Sci 6(1):18–24CrossRef Fogt JS, Menner A, Patton K (2022) Evaluation of wear experience with water surface daily disposable lenses in satisfied reusable soft contact lens wearers. J Contact Lens Res Sci 6(1):18–24CrossRef
14.
Zurück zum Zitat Penbe A, Kanar HS, Donmez GR (2022) Comparison of the pre-lens tear film stability and visual performance of a novel and two other daily disposable contact lenses in healthcare professionals wearing facial masks for prolonged time. Clin Optom (Auckl) 10(14):183–192. https://doi.org/10.2147/OPTO.S384246CrossRef Penbe A, Kanar HS, Donmez GR (2022) Comparison of the pre-lens tear film stability and visual performance of a novel and two other daily disposable contact lenses in healthcare professionals wearing facial masks for prolonged time. Clin Optom (Auckl) 10(14):183–192. https://​doi.​org/​10.​2147/​OPTO.​S384246CrossRef
16.
Zurück zum Zitat Itoi M, Higuchi H, Fushimi N, Ninomiya S, Higashihara H, Ono J, Uchida K (2018) Clinical evaluation of two types of daily disposable silicone hydrogel contact lenses. Atarashii Ganka 35(7):992–998 Itoi M, Higuchi H, Fushimi N, Ninomiya S, Higashihara H, Ono J, Uchida K (2018) Clinical evaluation of two types of daily disposable silicone hydrogel contact lenses. Atarashii Ganka 35(7):992–998
19.
Zurück zum Zitat Tyler’s quarterly soft contact lens parameter guide. Tyler’s Q soft contact lens Param Guid. September 2019 Tyler’s quarterly soft contact lens parameter guide. Tyler’s Q soft contact lens Param Guid. September 2019
20.
Zurück zum Zitat SIBF (2019) Surface characterization methods developed to optimize the “SMARTSURFACE®” chemistry for Precision1™ (One Day Contact Lenses).Presented at the BioInterface workshop and symposium of the Surfaces in Biomaterials Foundation. September 4–6. Park City, Utah SIBF (2019) Surface characterization methods developed to optimize the “SMARTSURFACE®” chemistry for Precision1™ (One Day Contact Lenses).Presented at the BioInterface workshop and symposium of the Surfaces in Biomaterials Foundation. September 4–6. Park City, Utah
21.
Zurück zum Zitat Precision 1 (2019) Lens with Smart Surface Technical File, Alcon Data on File 2019 Precision 1 (2019) Lens with Smart Surface Technical File, Alcon Data on File 2019
22.
Zurück zum Zitat Miyazaki D, Fukushima A, Uchio E, Shoji J, Namba K, Ebihara N, Takamura E, Fukuda K, Matsuda A, Okamoto S, Fukagawa K, Fujishima H, Ohno S, Ohashi Y (2022) Japanese Society of Ocular Allergology, The Japanese Society of Allergology. Executive summary: Japanese guidelines for allergic conjunctival diseases 2021. Allergol Int 71(4):459–471. https://doi.org/10.1016/j.alit.2022.07.005CrossRefPubMed Miyazaki D, Fukushima A, Uchio E, Shoji J, Namba K, Ebihara N, Takamura E, Fukuda K, Matsuda A, Okamoto S, Fukagawa K, Fujishima H, Ohno S, Ohashi Y (2022) Japanese Society of Ocular Allergology, The Japanese Society of Allergology. Executive summary: Japanese guidelines for allergic conjunctival diseases 2021. Allergol Int 71(4):459–471. https://​doi.​org/​10.​1016/​j.​alit.​2022.​07.​005CrossRefPubMed
25.
Zurück zum Zitat Tucker B (2019) Presented at the BioInterface workshop and symposium of the Surfaces in Biomaterials Foundation, Sept 4–6, 2019; Park City Tucker B (2019) Presented at the BioInterface workshop and symposium of the Surfaces in Biomaterials Foundation, Sept 4–6, 2019; Park City
26.
Zurück zum Zitat Tucker BLE, Bauman E, Subbaraman L (2019) Characterization of the surface properties of a novel daily disposable silicone hydrogel contact lens. Poster presented at the American Academy of Optometry (AAO) Annual Meeting. October 23–26, 2019; Orlando, Florida; Poster #62* Tucker BLE, Bauman E, Subbaraman L (2019) Characterization of the surface properties of a novel daily disposable silicone hydrogel contact lens. Poster presented at the American Academy of Optometry (AAO) Annual Meeting. October 23–26, 2019; Orlando, Florida; Poster #62*
Metadaten
Titel
Comparison of comfort and tear stability with two novel silicone-hydrogel daily disposable contact lenses
verfasst von
Tatsuya Mimura
Hidetaka Noma
Masao Yamaguchi
Koichiro Shinbo
Publikationsdatum
01.12.2024
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 1/2024
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-024-03075-z

Weitere Artikel der Ausgabe 1/2024

International Ophthalmology 1/2024 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Metastase in der periokulären Region

Metastasen Leitthema

Orbitale und periokuläre metastatische Tumoren galten früher als sehr selten. Aber mit der ständigen Aktualisierung von Medikamenten und Nachweismethoden für die Krebsbehandlung werden neue Chemotherapien und Strahlenbehandlungen eingesetzt. Die …

Staging und Systemtherapie bei okulären und periokulären Metastasen

Metastasen Leitthema

Metastasen bösartiger Erkrankungen sind die häufigsten Tumoren, die im Auge diagnostiziert werden. Sie treten bei ungefähr 5–10 % der Patienten mit soliden Tumoren im Verlauf der Erkrankung auf. Besonders häufig sind diese beim Mammakarzinom und …

Wundheilung nach Trabekulektomie

Trabekulektomie CME-Artikel

Die überschießende Wundheilung in der filtrierenden Glaukomchirurgie ist ein zentraler Faktor für ein operatives Versagen. Nach der Einführung der Trabekulektomie in den 1960er-Jahren wurden viele Faktoren erkannt, die mit einer vermehrten …

„standard operating procedures“ (SOP) – Vorschlag zum therapeutischen Management bei periokulären sowie intraokulären Metastasen

Metastasen Leitthema

Peri- sowie intraokuläre Metastasen sind insgesamt gesehen selten und meist Zeichen einer fortgeschrittenen primären Tumorerkrankung. Die Therapie ist daher zumeist palliativ und selten kurativ. Zudem ist die Therapiefindung sehr individuell. Die …

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.