Skip to main content
Erschienen in: Clinical Research in Cardiology 12/2013

01.12.2013 | Original Paper

Left atrial isthmus line ablation using a remote robotic navigation system: feasibility, efficacy and long-term outcome

verfasst von: Andreas Rillig, Boris Schmidt, Britta Feige, Erik Wissner, Andreas Metzner, Anita Arya, Shibu Mathew, Hisaki Makimoto, Peter Wohlmuth, Feifan Ouyang, Karl-Heinz Kuck, Roland Richard Tilz

Erschienen in: Clinical Research in Cardiology | Ausgabe 12/2013

Einloggen, um Zugang zu erhalten

Abstract

Background

Left atrial isthmus (LAI)-ablation in addition to circumferential pulmonary vein isolation (CPVI) may improve outcomes in select patients with atrial fibrillation (AF). However, bidirectional LAI-block is difficult to obtain. No systematic evaluation reporting on the feasibility and efficacy of LAI-ablation using a robotic navigation system (RNS) exists.

Methods and results

In this pilot study, CPVI combined with LAI-ablation were performed using a RNS and 3D-mapping system in 42 patients with persistent (n = 24, 57.1 %) or longstanding persistent AF. Ablation was performed using either a 3.5 mm irrigated tip catheter (ITC) with 6 (group-A, n = 16; max. 40 W, contact force 10–40 g) or (after a steam pop occurred in one patient) with a 4 mm ITC with 12 irrigation holes (group-B, n = 26; max. 30 W, contact force 10–30 g). Epicardial ablation was performed manually whenever bidirectional LAI-block could not be obtained with a maximum of 20 endocardial RF-applications. LAI-conduction block was achieved in all patients using RNS; in six patients (14.3 %), additional epicardial ablation was required to achieve LAI-block. A steam pop occurred during LAI-ablation resulting in cardiac tamponade in one patient in group-A. After a median follow-up period of 21 months, arrhythmia recurrence was seen in in 23/42 patients (18 patients with AF and 5 patients with atrial tachycardia) and repeat procedure was performed in 12 (28.6 %) patients; recovered LAI-conduction was found in 5/12 (41.7 %) patients. The RNS-group was compared to a historical group of 20 patients with manual LAI-ablation. Using RNS, LAI-block was more often achieved (42 (100 %) vs 16 (80 %), p < 0.01) and epicardial ablation was required in a significantly smaller number of patients (6 (14.3) vs 10 (50 %), p < 0.01).

Conclusions

LAI-ablation using RNS appears to be feasible in all patients. At repeat procedure, LAI-conduction can frequently occur; power and contact-force adaption appears to be mandatory to reduce the risk of complications. Using RNS, instead of a manual approach for LAI-line ablation may facilitate creation of a bidirectional LAI-block.
Literatur
1.
Zurück zum Zitat Ouyang F, Tilz R, Chun J, Schmidt B, Wissner E, Zerm T, Neven K, Köktürk B, Konstantinidou M, Metzner A, Fuernkranz A, Kuck KH (2010) Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation 122:2368–2377PubMedCrossRef Ouyang F, Tilz R, Chun J, Schmidt B, Wissner E, Zerm T, Neven K, Köktürk B, Konstantinidou M, Metzner A, Fuernkranz A, Kuck KH (2010) Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation 122:2368–2377PubMedCrossRef
2.
Zurück zum Zitat Chun KR, Schmidt B, Kuck KH, Andresen D, Willems S, Spitzer SG, Hoffmann E, Schumacher B, Eckardt L, Seidl K, Jünger C, Horack M, Brachmann J, Senges J (2013) Catheter ablation of atrial fibrillation in the young: insights from the German Ablation Registry. Clin Res Cardiol 102(6):459–468PubMedCrossRef Chun KR, Schmidt B, Kuck KH, Andresen D, Willems S, Spitzer SG, Hoffmann E, Schumacher B, Eckardt L, Seidl K, Jünger C, Horack M, Brachmann J, Senges J (2013) Catheter ablation of atrial fibrillation in the young: insights from the German Ablation Registry. Clin Res Cardiol 102(6):459–468PubMedCrossRef
3.
Zurück zum Zitat Oral H, Pappone C, Chugh A, Good E, Bogun F, Pelosi F Jr, Bates ER, Lehmann MH, Vicedomini G, Augello G, Agricola E, Sala S, Santinelli V, Morady F (2006) Circumferential pulmonary-vein ablation for chronic atrial fibrillation. N Engl J Med 2(354):934–941CrossRef Oral H, Pappone C, Chugh A, Good E, Bogun F, Pelosi F Jr, Bates ER, Lehmann MH, Vicedomini G, Augello G, Agricola E, Sala S, Santinelli V, Morady F (2006) Circumferential pulmonary-vein ablation for chronic atrial fibrillation. N Engl J Med 2(354):934–941CrossRef
4.
Zurück zum Zitat Tilz RR, Chun KR, Schmidt B, Fuernkranz A, Wissner E, Koester I, Baensch D, Boczor S, Koektuerk B, Metzner A, Zerm T, Ernst S, Antz M, Kuck KH, Ouyang F (2010) Catheter ablation of long-standing persistent atrial fibrillation: a lesson from circumferential pulmonary vein isolation. J Cardiovasc Electrophysiol 21:1085–1093PubMedCrossRef Tilz RR, Chun KR, Schmidt B, Fuernkranz A, Wissner E, Koester I, Baensch D, Boczor S, Koektuerk B, Metzner A, Zerm T, Ernst S, Antz M, Kuck KH, Ouyang F (2010) Catheter ablation of long-standing persistent atrial fibrillation: a lesson from circumferential pulmonary vein isolation. J Cardiovasc Electrophysiol 21:1085–1093PubMedCrossRef
5.
Zurück zum Zitat Tilz RR, Rillig A, Thum AM, Arya A, Wohlmuth P, Metzner A, Mathew S, Yoshiga Y, Wissner E, Kuck KH, Ouyang F (2012) Catheter ablation of long-standing persistent atrial fibrillation: 5-year outcomes of the hamburg sequential ablation strategy. J Am Coll Cardiol 60(19):1921–1929PubMedCrossRef Tilz RR, Rillig A, Thum AM, Arya A, Wohlmuth P, Metzner A, Mathew S, Yoshiga Y, Wissner E, Kuck KH, Ouyang F (2012) Catheter ablation of long-standing persistent atrial fibrillation: 5-year outcomes of the hamburg sequential ablation strategy. J Am Coll Cardiol 60(19):1921–1929PubMedCrossRef
6.
Zurück zum Zitat Schmidt M, Dorwarth U, Straube F, Wankerl M, Krieg J, Leber AW, Ebersberger HU, Daccarett M, Huber A, Rummeny E, Hoffmann E (2012) A novel double cryoballoon strategy in persistent atrial fibrillation: a pilot study. Clin Res Cardiol 101(10):777–785PubMedCrossRef Schmidt M, Dorwarth U, Straube F, Wankerl M, Krieg J, Leber AW, Ebersberger HU, Daccarett M, Huber A, Rummeny E, Hoffmann E (2012) A novel double cryoballoon strategy in persistent atrial fibrillation: a pilot study. Clin Res Cardiol 101(10):777–785PubMedCrossRef
7.
Zurück zum Zitat Jaïs P, Hocini M, Hsu LF, Sanders P, Scavee C, Weerasooriya R, Macle L, Raybaud F, Garrigue S, Shah DC, Le Metayer P, Clémenty J, Haïssaguerre M (2004) Technique and results of linear ablation at the mitral isthmus. Circulation 110:2996–3002PubMedCrossRef Jaïs P, Hocini M, Hsu LF, Sanders P, Scavee C, Weerasooriya R, Macle L, Raybaud F, Garrigue S, Shah DC, Le Metayer P, Clémenty J, Haïssaguerre M (2004) Technique and results of linear ablation at the mitral isthmus. Circulation 110:2996–3002PubMedCrossRef
8.
Zurück zum Zitat Willems S, Klemm H, Rostock T, Brandstrup B, Ventura R, Steven D, Risius T, Lutomsky B, Meinertz T (2006) Substrate modification combined with pulmonary vein isolation improves outcome of catheter ablation in patients with persistent atrial fibrillation: a prospective randomized comparison. Eur Heart J 27:2871–2878PubMedCrossRef Willems S, Klemm H, Rostock T, Brandstrup B, Ventura R, Steven D, Risius T, Lutomsky B, Meinertz T (2006) Substrate modification combined with pulmonary vein isolation improves outcome of catheter ablation in patients with persistent atrial fibrillation: a prospective randomized comparison. Eur Heart J 27:2871–2878PubMedCrossRef
9.
Zurück zum Zitat Fassini G, Riva S, Chiodelli R, Trevisi N, Berti M, Carbucicchio C, Maccabelli G, Giraldi F, Bella PD (2005) Left mitral isthmus ablation associated with PV Isolation: long-term results of a prospective randomized study. J Cardiovasc Electrophysiol 16:1150–1156PubMedCrossRef Fassini G, Riva S, Chiodelli R, Trevisi N, Berti M, Carbucicchio C, Maccabelli G, Giraldi F, Bella PD (2005) Left mitral isthmus ablation associated with PV Isolation: long-term results of a prospective randomized study. J Cardiovasc Electrophysiol 16:1150–1156PubMedCrossRef
10.
Zurück zum Zitat Wong KC, Lim C, Sadarmin PP, Jones M, Qureshi N, De Bono J, Rajappan K, Bashir Y, Betts TR (2011) High incidence of acute sub-clinical circumflex artery “injury” following mitral isthmus ablation. Eur Heart J 32:1881–1890PubMedCrossRef Wong KC, Lim C, Sadarmin PP, Jones M, Qureshi N, De Bono J, Rajappan K, Bashir Y, Betts TR (2011) High incidence of acute sub-clinical circumflex artery “injury” following mitral isthmus ablation. Eur Heart J 32:1881–1890PubMedCrossRef
11.
Zurück zum Zitat Takahashi Y, Jaïs P, Hocini M, Sanders P, Rotter M, Rostock T, Sacher F, Jaïs C, Clémenty J, Haïssaguerre M (2005) Acute occlusion of the left circumflex coronary artery during mitral isthmus linear ablation. J Cardiovasc Electrophysiol 16:1104–1107PubMedCrossRef Takahashi Y, Jaïs P, Hocini M, Sanders P, Rotter M, Rostock T, Sacher F, Jaïs C, Clémenty J, Haïssaguerre M (2005) Acute occlusion of the left circumflex coronary artery during mitral isthmus linear ablation. J Cardiovasc Electrophysiol 16:1104–1107PubMedCrossRef
12.
Zurück zum Zitat Horlitz M, Schley P, Shin DI, Tonnellier B, Gülker H (2008) Atrial tachycardias following circumferential pulmonary vein ablation: observations during catheter ablation. Clin Res Cardiol 97(2):124–130PubMedCrossRef Horlitz M, Schley P, Shin DI, Tonnellier B, Gülker H (2008) Atrial tachycardias following circumferential pulmonary vein ablation: observations during catheter ablation. Clin Res Cardiol 97(2):124–130PubMedCrossRef
13.
Zurück zum Zitat Matsuo S, Yamane T, Date T, Hioki M, Narui R, Ito K, Tanigawa S, Nakane T, Yamashita S, Tokuda M, Inada K, Nojiri A, Kawai M, Sugimoto K, Yoshimura M (2011) Completion of mitral isthmus ablation using a steerable sheath: prospective randomized comparison with a nonsteerable sheath. J Cardiovasc Electrophysiol 22:1331–1338PubMedCrossRef Matsuo S, Yamane T, Date T, Hioki M, Narui R, Ito K, Tanigawa S, Nakane T, Yamashita S, Tokuda M, Inada K, Nojiri A, Kawai M, Sugimoto K, Yoshimura M (2011) Completion of mitral isthmus ablation using a steerable sheath: prospective randomized comparison with a nonsteerable sheath. J Cardiovasc Electrophysiol 22:1331–1338PubMedCrossRef
14.
Zurück zum Zitat Lüthje L, Vollmann D, Seegers J, Dorenkamp M, Sohns C, Hasenfuss G, Zabel M (2011) Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillation. Clin Res Cardiol 100(11):1003–1011PubMedCrossRef Lüthje L, Vollmann D, Seegers J, Dorenkamp M, Sohns C, Hasenfuss G, Zabel M (2011) Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillation. Clin Res Cardiol 100(11):1003–1011PubMedCrossRef
15.
Zurück zum Zitat Saliba W, Reddy VY, Wazni O, Cummings JE, Burkhardt JD, Haissaguerre M, Kautzner J, Peichl P, Neuzil P, Schibgilla V, Noelker G, Brachmann J, Di Biase L, Barrett C, Jais P, Natale A (2008) Atrial fibrillation ablation using a robotic catheter remote control system. J Am Coll Cardiol 51:2407–2411PubMedCrossRef Saliba W, Reddy VY, Wazni O, Cummings JE, Burkhardt JD, Haissaguerre M, Kautzner J, Peichl P, Neuzil P, Schibgilla V, Noelker G, Brachmann J, Di Biase L, Barrett C, Jais P, Natale A (2008) Atrial fibrillation ablation using a robotic catheter remote control system. J Am Coll Cardiol 51:2407–2411PubMedCrossRef
16.
Zurück zum Zitat Di Biase L, Wang Y, Horton R, Gallinghouse GJ, Mohanty P, Sanchez J, Patel D, Dare M, Canby R, Price LD, Zagrodzky JD, Bailey S, Burkhardt JD, Natale A (2009) Ablation of atrial fibrillation utilizing robotic catheter navigation in comparison to manual navigation and ablation: single-center experience. J Cardiovasc Electrophysiol 20:1328–1335PubMedCrossRef Di Biase L, Wang Y, Horton R, Gallinghouse GJ, Mohanty P, Sanchez J, Patel D, Dare M, Canby R, Price LD, Zagrodzky JD, Bailey S, Burkhardt JD, Natale A (2009) Ablation of atrial fibrillation utilizing robotic catheter navigation in comparison to manual navigation and ablation: single-center experience. J Cardiovasc Electrophysiol 20:1328–1335PubMedCrossRef
17.
Zurück zum Zitat Schmidt B, Tilz RR, Neven K, Julian Chun KR, Fürnkranz A, Ouyang F (2009) Remote robotic navigation and electroanatomical mapping for ablation of atrial fibrillation: considerations for navigation and impact on procedural outcome. Circ Arrhythm Electrophysiol 2:120–128PubMedCrossRef Schmidt B, Tilz RR, Neven K, Julian Chun KR, Fürnkranz A, Ouyang F (2009) Remote robotic navigation and electroanatomical mapping for ablation of atrial fibrillation: considerations for navigation and impact on procedural outcome. Circ Arrhythm Electrophysiol 2:120–128PubMedCrossRef
18.
Zurück zum Zitat Wazni OM, Barrett C, Martin DO, Shaheen M, Tarakji K, Baranowski B, Hussein A, Callahan T, Dresing T, Bhargava M, Kanj M, Tchou P, Natale A, Saliba W (2009) Experience with the hansen robotic system for atrial fibrillation ablation-lessons learned and techniques modified: hansen in the real world. J Cardiovasc Electrophysiol 20:1193–1196PubMedCrossRef Wazni OM, Barrett C, Martin DO, Shaheen M, Tarakji K, Baranowski B, Hussein A, Callahan T, Dresing T, Bhargava M, Kanj M, Tchou P, Natale A, Saliba W (2009) Experience with the hansen robotic system for atrial fibrillation ablation-lessons learned and techniques modified: hansen in the real world. J Cardiovasc Electrophysiol 20:1193–1196PubMedCrossRef
19.
Zurück zum Zitat Rillig A, Meyerfeldt U, Birkemeyer R, Treusch F, Kunze M, Miljak T, Zvereva V, Jung W (2010) Remote robotic catheter ablation for atrial fibrillation: how fast is it learned and what benefits can be earned? J Interv Card Electrophysiol 29:109–117PubMedCrossRef Rillig A, Meyerfeldt U, Birkemeyer R, Treusch F, Kunze M, Miljak T, Zvereva V, Jung W (2010) Remote robotic catheter ablation for atrial fibrillation: how fast is it learned and what benefits can be earned? J Interv Card Electrophysiol 29:109–117PubMedCrossRef
20.
Zurück zum Zitat Tilz RR, Rillig A, Wissner E, Kivelitz DE, Ouyang F (2011) Successful robotic pulmonary vein isolation in adverse anatomy: dextrocardia with situs solitus, D-loop ventricles, and normally related great arteries. Eur Heart J 32:774PubMedCrossRef Tilz RR, Rillig A, Wissner E, Kivelitz DE, Ouyang F (2011) Successful robotic pulmonary vein isolation in adverse anatomy: dextrocardia with situs solitus, D-loop ventricles, and normally related great arteries. Eur Heart J 32:774PubMedCrossRef
21.
Zurück zum Zitat Bai R, DI Biase L, Valderrabano M, Lorgat F, Mlcochova H, Tilz R, Meyerfeldt U, Hranitzky PM, Wazni O, Kanagaratnam P, Doshi RN, Gibson D, Pisapia A, Mohanty P, Saliba W, Ouyang F, Kautzner J, Gallinghouse GJ, Natale A (2012) Worldwide experience with the robotic navigation system in catheter ablation of atrial fibrillation: methodology, efficacy and safety. J Cardiovasc Electrophysiol 23(8):820–826PubMedCrossRef Bai R, DI Biase L, Valderrabano M, Lorgat F, Mlcochova H, Tilz R, Meyerfeldt U, Hranitzky PM, Wazni O, Kanagaratnam P, Doshi RN, Gibson D, Pisapia A, Mohanty P, Saliba W, Ouyang F, Kautzner J, Gallinghouse GJ, Natale A (2012) Worldwide experience with the robotic navigation system in catheter ablation of atrial fibrillation: methodology, efficacy and safety. J Cardiovasc Electrophysiol 23(8):820–826PubMedCrossRef
22.
Zurück zum Zitat Hlivák P, Mlčochová H, Peichl P, Cihák R, Wichterle D, Kautzner J (2011) Robotic navigation in catheter ablation for paroxysmal atrial fibrillation: midterm efficacy and predictors of postablation arrhythmia recurrences. J Cardiovasc Electrophysiol 22(5):534–540PubMedCrossRef Hlivák P, Mlčochová H, Peichl P, Cihák R, Wichterle D, Kautzner J (2011) Robotic navigation in catheter ablation for paroxysmal atrial fibrillation: midterm efficacy and predictors of postablation arrhythmia recurrences. J Cardiovasc Electrophysiol 22(5):534–540PubMedCrossRef
23.
Zurück zum Zitat Duncan ER, Finlay M, Page SP, Hunter R, Goromonzi F, Richmond L, Baker V, Ginks M, Ezzat V, Dhinoja M, Earley MJ, Sporton S, Schilling RJ (2012) Improved electrogram attenuation during ablation of paroxysmal atrial fibrillation with the Hansen robotic system. Pacing Clin Electrophysiol 35(6):730–738PubMedCrossRef Duncan ER, Finlay M, Page SP, Hunter R, Goromonzi F, Richmond L, Baker V, Ginks M, Ezzat V, Dhinoja M, Earley MJ, Sporton S, Schilling RJ (2012) Improved electrogram attenuation during ablation of paroxysmal atrial fibrillation with the Hansen robotic system. Pacing Clin Electrophysiol 35(6):730–738PubMedCrossRef
24.
Zurück zum Zitat Di Biase L, Natale A, Barrett C, Tan C, Elayi CS, Ching CK, Wang P, Al-Ahmad A, Arruda M, Burkhardt JD, Wisnoskey BJ, Chowdhury P, De Marco S, Armaganijan L, Litwak KN, Schweikert RA, Cummings JE (2009) Relationship between catheter forces, lesion characteristics, “popping,” and char formation: experience with robotic navigation system. J Cardiovasc Electrophysiol 20(4):436–440PubMedCrossRef Di Biase L, Natale A, Barrett C, Tan C, Elayi CS, Ching CK, Wang P, Al-Ahmad A, Arruda M, Burkhardt JD, Wisnoskey BJ, Chowdhury P, De Marco S, Armaganijan L, Litwak KN, Schweikert RA, Cummings JE (2009) Relationship between catheter forces, lesion characteristics, “popping,” and char formation: experience with robotic navigation system. J Cardiovasc Electrophysiol 20(4):436–440PubMedCrossRef
25.
Zurück zum Zitat Hocini M, Jaïs P, Sanders P, Takahashi Y, Rotter M, Rostock T, Hsu LF, Sacher F, Reuter S, Clémenty J, Haïssaguerre M (2005) Techniques, evaluation, and consequences of linear block at the left atrial roof in paroxysmal atrial fibrillation: a prospective randomized study. Circulation 112:3688–3696PubMedCrossRef Hocini M, Jaïs P, Sanders P, Takahashi Y, Rotter M, Rostock T, Hsu LF, Sacher F, Reuter S, Clémenty J, Haïssaguerre M (2005) Techniques, evaluation, and consequences of linear block at the left atrial roof in paroxysmal atrial fibrillation: a prospective randomized study. Circulation 112:3688–3696PubMedCrossRef
26.
Zurück zum Zitat Ouyang F, Ernst S, Vogtmann T, Goya M, Volkmer M, Schaumann A, Bänsch D, Antz M, Kuck KH (2002) Characterization of reentrant circuits in left atrial macroreentrant tachycardia: critical isthmus block can prevent atrial tachycardia recurrence. Circulation 105:1934–1942PubMedCrossRef Ouyang F, Ernst S, Vogtmann T, Goya M, Volkmer M, Schaumann A, Bänsch D, Antz M, Kuck KH (2002) Characterization of reentrant circuits in left atrial macroreentrant tachycardia: critical isthmus block can prevent atrial tachycardia recurrence. Circulation 105:1934–1942PubMedCrossRef
27.
Zurück zum Zitat Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, Crijns HJ, Damiano RJ Jr, Davies DW, DiMarco J, Edgerton J, Ellenbogen K, Ezekowitz MD, Haines DE, Haissaguerre M, Hindricks G, Iesaka Y, Jackman W, Jalife J, Jais P, Kalman J, Keane D, Kim YH, Kirchhof P, Klein G, Kottkamp H, Kumagai K, Lindsay BD, Mansour M, Marchlinski FE, McCarthy PM, Mont JL, Morady F, Nademanee K, Nakagawa H, Natale A, Nattel S, Packer DL, Pappone C, Prystowsky E, Raviele A, Reddy V, Ruskin JN, Shemin RJ, Tsao HM, Wilber D (2012) Heart Rhythm Society Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society. Heart Rhythm 9:632–696PubMedCrossRef Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, Crijns HJ, Damiano RJ Jr, Davies DW, DiMarco J, Edgerton J, Ellenbogen K, Ezekowitz MD, Haines DE, Haissaguerre M, Hindricks G, Iesaka Y, Jackman W, Jalife J, Jais P, Kalman J, Keane D, Kim YH, Kirchhof P, Klein G, Kottkamp H, Kumagai K, Lindsay BD, Mansour M, Marchlinski FE, McCarthy PM, Mont JL, Morady F, Nademanee K, Nakagawa H, Natale A, Nattel S, Packer DL, Pappone C, Prystowsky E, Raviele A, Reddy V, Ruskin JN, Shemin RJ, Tsao HM, Wilber D (2012) Heart Rhythm Society Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society. Heart Rhythm 9:632–696PubMedCrossRef
28.
Zurück zum Zitat Kuck KH, Ernst S, Dorwarth U, Hoffmann E, Pitschner H, Tebbenjohanns J, Kottkamp H (2007) Guidelines for catheter ablation. Clin Res Cardiol 96(11):833–849PubMedCrossRef Kuck KH, Ernst S, Dorwarth U, Hoffmann E, Pitschner H, Tebbenjohanns J, Kottkamp H (2007) Guidelines for catheter ablation. Clin Res Cardiol 96(11):833–849PubMedCrossRef
29.
Zurück zum Zitat Willems S, Steven D, Servatius H, Hoffmann BA, Drewitz I, Müllerleile K, Aydin MA, Wegscheider K, Salukhe TV, Meinertz T, Rostock T (2010) Persistence of pulmonary vein isolation after robotic remote-navigated ablation for atrial fibrillation and its relation to clinical outcome. J Cardiovasc Electrophysiol 21(10):1079–1084PubMedCrossRef Willems S, Steven D, Servatius H, Hoffmann BA, Drewitz I, Müllerleile K, Aydin MA, Wegscheider K, Salukhe TV, Meinertz T, Rostock T (2010) Persistence of pulmonary vein isolation after robotic remote-navigated ablation for atrial fibrillation and its relation to clinical outcome. J Cardiovasc Electrophysiol 21(10):1079–1084PubMedCrossRef
30.
Zurück zum Zitat Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, Schaumann A, Chun J, Falk P, Hennig D, Liu X, Bänsch D, Kuck KH (2005) Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double lasso technique. Circulation 111:127–135PubMedCrossRef Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, Schaumann A, Chun J, Falk P, Hennig D, Liu X, Bänsch D, Kuck KH (2005) Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double lasso technique. Circulation 111:127–135PubMedCrossRef
Metadaten
Titel
Left atrial isthmus line ablation using a remote robotic navigation system: feasibility, efficacy and long-term outcome
verfasst von
Andreas Rillig
Boris Schmidt
Britta Feige
Erik Wissner
Andreas Metzner
Anita Arya
Shibu Mathew
Hisaki Makimoto
Peter Wohlmuth
Feifan Ouyang
Karl-Heinz Kuck
Roland Richard Tilz
Publikationsdatum
01.12.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Research in Cardiology / Ausgabe 12/2013
Print ISSN: 1861-0684
Elektronische ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-013-0602-1

Weitere Artikel der Ausgabe 12/2013

Clinical Research in Cardiology 12/2013 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.