Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 3/2015

01.03.2015 | Glaucoma

Flicker-defined form perimetry in glaucoma patients

verfasst von: Folkert K. Horn, Jan Kremers, Christian Y. Mardin, Anselm G. Jünemann, Werner Adler, Ralf P. Tornow

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 3/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To assess the potential of flicker-defined form (FDF) perimetry to detect functional loss in patient groups with beginning glaucoma, and to evaluate the dynamic range of the FDF stimulus in individual patients and at individual test positions.

Methods

FDF perimetry and standard automated perimetry (SAP) were performed at identical test locations (adapted G1 protocol) in 60 healthy subjects and 111 glaucoma patients. All patients showed glaucomatous optic disc appearance. Grouping within the glaucoma cohort was based on SAP-performance: 33 “preperimetric” open-angle glaucoma (OAG) patients, 28 “borderline” OAG (focal defects and SAP-mean defect (MD) <2 dB), 33 “early” OAG (SAP-MD < 5 dB), 17 “advanced” OAG. All participants were experienced in psychophysical and perimetric tests. Defect values and the areas under receiver operating characteristic curves (ROC) in patient groups were statistically compared.

Results

The values of FDF-MD in the preperimetric, borderline, and early OAG group were 2.7 ± 3.4 dB, 5.5 ± 2.6 dB, and 8.5 ± 3.4 dB respectively (all significantly above normal). The percentage of patients exceeding normal FDF-MD was 27.3 %, 60.7 %, and 87.9 % respectively. The age-adjusted FDF-mean defect (MD) of the G1X-protocol was not significantly correlated with refractive error, lens opacity, pupil size, or gender. Occurrence of ceiling effects (inability to detect targets at highest contrast) showed a high correlation with visual field losses (R = 0.72, p < 0.001). Local analysis indicates that SAP losses exceeding 5 dB could not be distinguished with the FDF technique.

Conclusion

The FDF stimulus was able to detect beginning glaucoma damage. Patients with SAP-MD values exceeding 5 dB should be monitored with conventional perimetry because of its larger dynamic range.
Literatur
2.
Zurück zum Zitat Tyler CW (1981) Specific deficits of flicker sensitivity in glaucoma and ocular hypertension. Invest Ophthalmol Vis Sci 20(2):204–212PubMed Tyler CW (1981) Specific deficits of flicker sensitivity in glaucoma and ocular hypertension. Invest Ophthalmol Vis Sci 20(2):204–212PubMed
3.
Zurück zum Zitat Lachenmayr BJ, Drance SM, Douglas GR, Mikelberg FS (1991) Light-sense, flicker and resolution perimetry in glaucoma: a comparative study. Graefes Arch Clin Exp Ophthalmol 229(3):246–251CrossRefPubMed Lachenmayr BJ, Drance SM, Douglas GR, Mikelberg FS (1991) Light-sense, flicker and resolution perimetry in glaucoma: a comparative study. Graefes Arch Clin Exp Ophthalmol 229(3):246–251CrossRefPubMed
5.
Zurück zum Zitat Horn FK, Korth M, Martus P (1994) Quick full-field flicker test in glaucoma diagnosis: correlations with perimetry and papillometry. J Glaucoma 3(3):206–213CrossRefPubMed Horn FK, Korth M, Martus P (1994) Quick full-field flicker test in glaucoma diagnosis: correlations with perimetry and papillometry. J Glaucoma 3(3):206–213CrossRefPubMed
6.
Zurück zum Zitat Sample PA, Medeiros FA, Racette L, Pascual JP, Boden C, Zangwill LM, Bowd C, Weinreb RN (2006) Identifying glaucomatous vision loss with visual-function-specific perimetry in the diagnostic innovations in glaucoma study. Invest Ophthalmol Vis Sci 47(8):3381–3389. doi:10.1167/iovs. 05-1546 CrossRefPubMed Sample PA, Medeiros FA, Racette L, Pascual JP, Boden C, Zangwill LM, Bowd C, Weinreb RN (2006) Identifying glaucomatous vision loss with visual-function-specific perimetry in the diagnostic innovations in glaucoma study. Invest Ophthalmol Vis Sci 47(8):3381–3389. doi:10.​1167/​iovs.​ 05-1546 CrossRefPubMed
7.
Zurück zum Zitat Anderson AJ, Johnson CA (2003) Frequency-doubling technology perimetry. Ophthalmol Clin N Am 16(2):213–225CrossRef Anderson AJ, Johnson CA (2003) Frequency-doubling technology perimetry. Ophthalmol Clin N Am 16(2):213–225CrossRef
8.
Zurück zum Zitat Ferreras A, Polo V, Larrosa JM, Pablo LE, Pajarin AB, Pueyo V, Honrubia FM (2007) Can frequency-doubling technology and short-wavelength automated perimetries detect visual field defects before standard automated perimetry in patients with preperimetric glaucoma? J Glaucoma 16(4):372–383CrossRefPubMed Ferreras A, Polo V, Larrosa JM, Pablo LE, Pajarin AB, Pueyo V, Honrubia FM (2007) Can frequency-doubling technology and short-wavelength automated perimetries detect visual field defects before standard automated perimetry in patients with preperimetric glaucoma? J Glaucoma 16(4):372–383CrossRefPubMed
11.
Zurück zum Zitat Yoshiyama KK, Johnson CA (1997) Which method of flicker perimetry is most effective for detection of glaucomatous visual field loss? Invest Ophthalmol Vis Sci 38(11):2270–2277PubMed Yoshiyama KK, Johnson CA (1997) Which method of flicker perimetry is most effective for detection of glaucomatous visual field loss? Invest Ophthalmol Vis Sci 38(11):2270–2277PubMed
14.
Zurück zum Zitat Lamparter J, Russell RA, Schulze A, Schuff AC, Pfeiffer N, Hoffmann EM (2012) Structure-function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients. Invest Ophthalmol Vis Sci 53(12):7553–7559. doi:10.1167/iovs. 12-10892 CrossRefPubMed Lamparter J, Russell RA, Schulze A, Schuff AC, Pfeiffer N, Hoffmann EM (2012) Structure-function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients. Invest Ophthalmol Vis Sci 53(12):7553–7559. doi:10.​1167/​iovs.​ 12-10892 CrossRefPubMed
15.
Zurück zum Zitat Horn FK, Tornow RP, Juenemann AG, Laemmer R, Kremers J (2014) Perimetric measurements with flicker defined form stimulation in comparison to conventional perimetry and retinal nerve fiber measurements. Invest Ophthalmol Vis Sci 55(4):2317–2323. doi:10.1167/iovs. 13-12469 CrossRefPubMed Horn FK, Tornow RP, Juenemann AG, Laemmer R, Kremers J (2014) Perimetric measurements with flicker defined form stimulation in comparison to conventional perimetry and retinal nerve fiber measurements. Invest Ophthalmol Vis Sci 55(4):2317–2323. doi:10.​1167/​iovs.​ 13-12469 CrossRefPubMed
16.
Zurück zum Zitat Lauterwald F, Neumann CP, Lenz R, Jünemann AG, Mardin CY, Meyer-Wegener K, Horn FK (2012) The Erlangen Glaucoma Registry: a scientific database for longitudinal analysis of glaucoma. Technical reports / Dep Informatik (ISSN 2191-5008) CS-2011,2:1-9 Lauterwald F, Neumann CP, Lenz R, Jünemann AG, Mardin CY, Meyer-Wegener K, Horn FK (2012) The Erlangen Glaucoma Registry: a scientific database for longitudinal analysis of glaucoma. Technical reports / Dep Informatik (ISSN 2191-5008) CS-2011,2:1-9
17.
Zurück zum Zitat Horn FK, Junemann AG, Korth M (2001) Two methods of lens opacity measurements in glaucomas. Doc Ophthalmol Adv Ophthalmol 103(2):105–117CrossRef Horn FK, Junemann AG, Korth M (2001) Two methods of lens opacity measurements in glaucomas. Doc Ophthalmol Adv Ophthalmol 103(2):105–117CrossRef
18.
Zurück zum Zitat Jonas JB, Budde WM, Panda-Jonas S (1999) Ophthalmoscopic evaluation of the optic nerve head. Surv Ophthalmol 43(4):293–320CrossRefPubMed Jonas JB, Budde WM, Panda-Jonas S (1999) Ophthalmoscopic evaluation of the optic nerve head. Surv Ophthalmol 43(4):293–320CrossRefPubMed
19.
Zurück zum Zitat Jonas JB, Gusek GC, Naumann GO (1988) Optic disc morphometry in chronic primary open-angle glaucoma. I. Morphometric intrapapillary characteristics. Graefes Arch Clin Exp Ophthalmol 226(6):522–530CrossRefPubMed Jonas JB, Gusek GC, Naumann GO (1988) Optic disc morphometry in chronic primary open-angle glaucoma. I. Morphometric intrapapillary characteristics. Graefes Arch Clin Exp Ophthalmol 226(6):522–530CrossRefPubMed
21.
Zurück zum Zitat Hodapp E, Parrish RK, Anderson DR (1993) Clinical decisions in glaucoma. Mosby, St. Louis, pp 52–61 Hodapp E, Parrish RK, Anderson DR (1993) Clinical decisions in glaucoma. Mosby, St. Louis, pp 52–61
23.
Zurück zum Zitat Mulak M, Szumny D, Sieja-Bujewska A, Kubrak M (2012) Heidelberg edge perimeter employment in glaucoma diagnosis—preliminary report. Adv Clin Exp Med 21(5):665–670PubMed Mulak M, Szumny D, Sieja-Bujewska A, Kubrak M (2012) Heidelberg edge perimeter employment in glaucoma diagnosis—preliminary report. Adv Clin Exp Med 21(5):665–670PubMed
24.
Zurück zum Zitat Quaid PT, Simpson TL, Flanagan JG (2005) Frequency doubling illusion: detection vs form resolution. Optom Vis Sci 82(1):36–42PubMed Quaid PT, Simpson TL, Flanagan JG (2005) Frequency doubling illusion: detection vs form resolution. Optom Vis Sci 82(1):36–42PubMed
27.
Zurück zum Zitat Matsumoto C, Okuyama S, Iwagaki A, Otsuki T, Otori T (1997) The influence of target blur on perimetric threshold values in automated light-sensitive perimetry and flicker perimetry. In: Wall M, Heiji A (eds) Perimetry update 1996/1997. Kugler, Amsterdam, pp 191–200 Matsumoto C, Okuyama S, Iwagaki A, Otsuki T, Otori T (1997) The influence of target blur on perimetric threshold values in automated light-sensitive perimetry and flicker perimetry. In: Wall M, Heiji A (eds) Perimetry update 1996/1997. Kugler, Amsterdam, pp 191–200
28.
Zurück zum Zitat Lachenmayr BJ, Kojetinsky S, Ostermaier N, Angstwurm K, Vivell PM, Schaumberger M (1994) The different effects of aging on normal sensitivity in flicker and light-sense perimetry. Invest Ophthalmol Vis Sci 35(6):2741–2748PubMed Lachenmayr BJ, Kojetinsky S, Ostermaier N, Angstwurm K, Vivell PM, Schaumberger M (1994) The different effects of aging on normal sensitivity in flicker and light-sense perimetry. Invest Ophthalmol Vis Sci 35(6):2741–2748PubMed
30.
Zurück zum Zitat May F, Giraud J-M, Francoz M, El Chehab H, Fenolland J-R, Sendon D, Denier C, El Asri F, Dieng M, Renard J-P (2012) Heidelberg Edge Perimetry: evaluation of the Flicker Defined Form test, versus Matrix, in normal and glaucoma subjects. Invest Ophthalmol Vis Sci 53(6):186 May F, Giraud J-M, Francoz M, El Chehab H, Fenolland J-R, Sendon D, Denier C, El Asri F, Dieng M, Renard J-P (2012) Heidelberg Edge Perimetry: evaluation of the Flicker Defined Form test, versus Matrix, in normal and glaucoma subjects. Invest Ophthalmol Vis Sci 53(6):186
Metadaten
Titel
Flicker-defined form perimetry in glaucoma patients
verfasst von
Folkert K. Horn
Jan Kremers
Christian Y. Mardin
Anselm G. Jünemann
Werner Adler
Ralf P. Tornow
Publikationsdatum
01.03.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 3/2015
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-014-2887-9

Weitere Artikel der Ausgabe 3/2015

Graefe's Archive for Clinical and Experimental Ophthalmology 3/2015 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.