Purpose

Traumatic disruption of the pelvis can lead to significant morbidity and mortality. ATLS® guidance advocates temporary stabilisation or ‘closure’ of the disrupted pelvis with a compression device or sheet. We undertook a best evidence equipment review to assess the ease and efficacy of the application of two leading commercially available devices, the T-POD® and the SAM Pelvic Sling™ II.

Methods

Fifty health care professionals and medical students participated in pelvic circumferential compression device (PCCD) education and assessment. Participants received a 10-min lecture on the epidemiology and aetiology of pelvic fractures and the principles of circumferential compression, followed by a practical demonstration. Three volunteers acted as trauma victims. Assessment included the time taken to secure the devices and whether this was achieved correctly. All participants completed a post-assessment survey.

Results

Both devices were applied correctly 100% of the time. The average time taken to secure the SAM Pelvic Sling™ II was 18 s and for the T-POD®, it was 31 s (p ≤ 0.0001). Forty-four participants (88%) agreed or strongly agreed that the SAM Pelvic Sling™ II was easy to use compared to 84% (n = 42) for the T-POD®. Thirty-nine participants (78%) reported that they preferred and, given the choice in the future, would select the T-POD® over the SAM Pelvic Sling™ II (n = 11, 22%).

Conclusions

The results of this study indicate that both PCCDs are easy and acceptable to use and, once learned, can be applied easily and rapidly. Participants applied both devices correctly 100% of the time, with successful application taking, on average, less than 60 s.
Literatur
1.
Zurück zum Zitat Croce MA, Magnotti LJ, Savage SA, Wood GW 2nd, Fabian TC. Emergent pelvic fixation in patients with exsanguinating pelvic fractures. J Am Coll Surg. 2007;205:935–9.PubMedCrossRef Croce MA, Magnotti LJ, Savage SA, Wood GW 2nd, Fabian TC. Emergent pelvic fixation in patients with exsanguinating pelvic fractures. J Am Coll Surg. 2007;205:935–9.PubMedCrossRef
2.
Zurück zum Zitat White CE, Hsu JR, Holcomb JB. Haemodynamically unstable pelvic fractures. Injury. 2009;10:1023–30.CrossRef White CE, Hsu JR, Holcomb JB. Haemodynamically unstable pelvic fractures. Injury. 2009;10:1023–30.CrossRef
4.
Zurück zum Zitat [No authors listed]. Advanced trauma life support course: student manual. 8th ed. Chicago: American College of Surgeons; 2008. [No authors listed]. Advanced trauma life support course: student manual. 8th ed. Chicago: American College of Surgeons; 2008.
5.
Zurück zum Zitat Krieg JC, Mohr M, Ellis TJ, Simpson TS, Madey SM, Bottlang M. Emergent stabilization of pelvic ring injuries by controlled circumferential compression: a clinical trial. J Trauma. 2005;59:659–64.PubMedCrossRef Krieg JC, Mohr M, Ellis TJ, Simpson TS, Madey SM, Bottlang M. Emergent stabilization of pelvic ring injuries by controlled circumferential compression: a clinical trial. J Trauma. 2005;59:659–64.PubMedCrossRef
6.
Zurück zum Zitat Spanjersberg WR, Knops SP, Schep NW, van Lieshout EM, Patka P, Schipper IB. Effectiveness and complications of pelvic circumferential compression devices in patients with unstable pelvic fractures: a systematic review of literature. Injury. 2009;40:1031–5.PubMedCrossRef Spanjersberg WR, Knops SP, Schep NW, van Lieshout EM, Patka P, Schipper IB. Effectiveness and complications of pelvic circumferential compression devices in patients with unstable pelvic fractures: a systematic review of literature. Injury. 2009;40:1031–5.PubMedCrossRef
7.
Zurück zum Zitat Schaller TM, Sims S, Maxian T. Skin breakdown following circumferential pelvic antishock sheeting: a case report. J Orthop Trauma. 2005;19:661–5.PubMedCrossRef Schaller TM, Sims S, Maxian T. Skin breakdown following circumferential pelvic antishock sheeting: a case report. J Orthop Trauma. 2005;19:661–5.PubMedCrossRef
8.
Zurück zum Zitat Guthrie HC, Owens RW, Bircher MD. Fractures of the pelvis. J Bone Joint Surg Br. 2010;92:1481–8.PubMedCrossRef Guthrie HC, Owens RW, Bircher MD. Fractures of the pelvis. J Bone Joint Surg Br. 2010;92:1481–8.PubMedCrossRef
9.
Zurück zum Zitat DeAngelis NA, Wixted JJ, Drew J, Eskander MS, Eskander JP, French BG. Use of the trauma pelvic orthotic device (T-POD) for provisional stabilisation of anterior–posterior compression type pelvic fractures: a cadaveric study. Injury. 2008;39:903–6.PubMedCrossRef DeAngelis NA, Wixted JJ, Drew J, Eskander MS, Eskander JP, French BG. Use of the trauma pelvic orthotic device (T-POD) for provisional stabilisation of anterior–posterior compression type pelvic fractures: a cadaveric study. Injury. 2008;39:903–6.PubMedCrossRef
10.
Zurück zum Zitat Bottlang M, Krieg JC, Mohr M, Simpson TS, Madey SM. Emergent management of pelvic ring fractures with use of circumferential compression. J Bone Joint Surg Am. 2002;84:43–7.PubMed Bottlang M, Krieg JC, Mohr M, Simpson TS, Madey SM. Emergent management of pelvic ring fractures with use of circumferential compression. J Bone Joint Surg Am. 2002;84:43–7.PubMed
Metadaten
Titel
Pelvic circumferential compression devices (PCCDs): a best evidence equipment review
verfasst von
D. J. Bryson
R. Davidson
R. Mackenzie
Publikationsdatum
01.08.2012
Verlag
Springer-Verlag
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 4/2012
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-012-0180-3

Weitere Artikel der Ausgabe 4/2012

European Journal of Trauma and Emergency Surgery 4/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.