Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 4/2011

01.04.2011 | Knee

Axial and torsional stability of supracondylar femur osteotomies: biomechanical comparison of the stability of five different plate and osteotomy configurations

verfasst von: J.-M. Brinkman, C. Hurschler, J. D. Agneskirchner, D. Freiling, R. J. van Heerwaarden

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 4/2011

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Little is known regarding the biomechanical stability and stiffness of implants and techniques used in supracondylar femur osteotomies (SCO). Therefore, fixation stability and stiffness of implants to bone was investigated under simulated physiological loading conditions using a composite femur model and a 3D motion-analysis system.

Methods

Five osteotomy configurations were investigated: (1) oblique medial closing-wedge fixated with an angle-stable implant; (2) oblique and (3) perpendicular medial closing-wedge, both fixated with an angled blade plate; and lateral opening-wedge fixated with (4) a spacer plate and (5) an angle-stable lateral implant. The motion measured at the osteotomy was used to calculate the stiffness and stability of the constructs.

Results

The least amount of motion and highest stiffness was measured in the medial oblique closing-wedge osteotomy fixated with the angled blade plate. The lateral opening-wedge techniques were less stable and had a lower stiffness compared with the medial; the oblique saw cuts were more stable and had a higher stiffness than the perpendicular.

Conclusion

This experimental study presents baseline data on the differences in the primary stability of bone–implant constructs used in SCO. The data in this study can be used as reference for future testing of SCO techniques. Furthermore, it is recommended that based on the differences found, the early postoperative rehabilitation protocol is tailored to the stability and stiffness of the fixation method used.
Literatur
1.
Zurück zum Zitat Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14:291–300PubMedCrossRef Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14:291–300PubMedCrossRef
2.
Zurück zum Zitat Brinkman JM, Lobenhoffer P, Agneskirchner JD, Staubli AE, Wymenga AB, van Heerwaarden RJ (2008) Osteotomies around the knee: patient selection, stability of fixation and bone healing in high tibial osteotomies. J Bone Joint Surg Br 90:1548–1557PubMedCrossRef Brinkman JM, Lobenhoffer P, Agneskirchner JD, Staubli AE, Wymenga AB, van Heerwaarden RJ (2008) Osteotomies around the knee: patient selection, stability of fixation and bone healing in high tibial osteotomies. J Bone Joint Surg Br 90:1548–1557PubMedCrossRef
3.
Zurück zum Zitat Cusick RP, Lucas GL, McQueen DA, Graber CD (2000) Construct stiffness of different fixation methods for supracondylar femoral fractures above total knee prostheses. Am J Orthop 29:695–699PubMed Cusick RP, Lucas GL, McQueen DA, Graber CD (2000) Construct stiffness of different fixation methods for supracondylar femoral fractures above total knee prostheses. Am J Orthop 29:695–699PubMed
4.
Zurück zum Zitat Dvir Z, Prushansky T (2000) Reproducibility and instrument validity of a new ultrasonography-based system for measuring cervical spine kinematics. Clin Biomech 15:658–664CrossRef Dvir Z, Prushansky T (2000) Reproducibility and instrument validity of a new ultrasonography-based system for measuring cervical spine kinematics. Clin Biomech 15:658–664CrossRef
5.
Zurück zum Zitat Firoozbakhsh K, Behzadi K, DeCoster TA, Moneim MS, Naraghi FF (1995) Mechanics of retrograde nail versus plate fixation for supracondylar femur fractures. J Orthop Trauma 9:152–157PubMedCrossRef Firoozbakhsh K, Behzadi K, DeCoster TA, Moneim MS, Naraghi FF (1995) Mechanics of retrograde nail versus plate fixation for supracondylar femur fractures. J Orthop Trauma 9:152–157PubMedCrossRef
6.
Zurück zum Zitat Franco V, Cipolla M, Gerullo G, Gianni E, Puddu G (2004) Open wedge osteotomy of the distal femur in the valgus knee. Orthopade 33:185–192PubMedCrossRef Franco V, Cipolla M, Gerullo G, Gianni E, Puddu G (2004) Open wedge osteotomy of the distal femur in the valgus knee. Orthopade 33:185–192PubMedCrossRef
7.
Zurück zum Zitat Frigg R (2003) Development of the locking compression plate. Injury 34(Supplement 2):6–10CrossRef Frigg R (2003) Development of the locking compression plate. Injury 34(Supplement 2):6–10CrossRef
8.
Zurück zum Zitat van Heerwaarden RJ, Wymenga AB, Freiling D, Lobenhoffer P (2007) Distal medial closed wedge varus femur osteotomy stabilized with Tomofix plate fixator. Op Tech Orthopaedics 17:12–21CrossRef van Heerwaarden RJ, Wymenga AB, Freiling D, Lobenhoffer P (2007) Distal medial closed wedge varus femur osteotomy stabilized with Tomofix plate fixator. Op Tech Orthopaedics 17:12–21CrossRef
9.
Zurück zum Zitat Heiner AD, Brown TD (2001) Structural properties of a new design of composite replicate femurs and tibias. J Biomech 34:773–781PubMedCrossRef Heiner AD, Brown TD (2001) Structural properties of a new design of composite replicate femurs and tibias. J Biomech 34:773–781PubMedCrossRef
10.
Zurück zum Zitat Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop 90:215–227 Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop 90:215–227
11.
Zurück zum Zitat Learmonth ID (1990) A simple technique for varus supracondylar osteotomy in genu valgum. J Bone Joint Surg Br 72:235–237PubMed Learmonth ID (1990) A simple technique for varus supracondylar osteotomy in genu valgum. J Bone Joint Surg Br 72:235–237PubMed
13.
Zurück zum Zitat Marti RK, Schröder J, Witteveen A (2000) The closed wedge varus supracondylar osteotomy. Oper Tech Sports Med 8:48–55CrossRef Marti RK, Schröder J, Witteveen A (2000) The closed wedge varus supracondylar osteotomy. Oper Tech Sports Med 8:48–55CrossRef
14.
Zurück zum Zitat McDermott AG, Finklestein JA, Farine I, Boynton EL, MacIntosh DL, Gross A (1988) Distal femoral varus osteotomy for valgus deformity of the knee. J Bone Joint Surg Am 70:110–116PubMed McDermott AG, Finklestein JA, Farine I, Boynton EL, MacIntosh DL, Gross A (1988) Distal femoral varus osteotomy for valgus deformity of the knee. J Bone Joint Surg Am 70:110–116PubMed
15.
Zurück zum Zitat Miniaci A, Grossmann SP, Jakob RP (1990) Supracondylar femoral varus osteotomy in the treatment of valgus knee deformity. Am J Knee Surg 3:65–73 Miniaci A, Grossmann SP, Jakob RP (1990) Supracondylar femoral varus osteotomy in the treatment of valgus knee deformity. Am J Knee Surg 3:65–73
16.
Zurück zum Zitat Miniaci A, Watson LW (2002) Distal femoral osteotomy. In: Fu FF (ed) Knee surgery, 1994. Williams & Wilkins, New York, pp 1173–1180 Miniaci A, Watson LW (2002) Distal femoral osteotomy. In: Fu FF (ed) Knee surgery, 1994. Williams & Wilkins, New York, pp 1173–1180
17.
Zurück zum Zitat Stahelin T, Hardegger F, Ward JC (2000) Supracondylar osteotomy of the femur with use of compression Osteosynthesis with a malleable implant. J Bone Joint Surg Am 82:712–722PubMed Stahelin T, Hardegger F, Ward JC (2000) Supracondylar osteotomy of the femur with use of compression Osteosynthesis with a malleable implant. J Bone Joint Surg Am 82:712–722PubMed
18.
Zurück zum Zitat Stahelin T, Hardegger F (2004) Incomplete, supracondylar femur osteotomy. A minimally invasive compression osteosynthesis with soft implant. Orthopade 33:178–184PubMedCrossRef Stahelin T, Hardegger F (2004) Incomplete, supracondylar femur osteotomy. A minimally invasive compression osteosynthesis with soft implant. Orthopade 33:178–184PubMedCrossRef
19.
Zurück zum Zitat Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia—early results in 92 cases. Injury 34(Suppl 2):55–62CrossRef Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia—early results in 92 cases. Injury 34(Suppl 2):55–62CrossRef
20.
Zurück zum Zitat Stoffel K, Dieter U, Stachowiak G, Gachter A, Kuster MS (2003) Biomechanical testing of the LCP—how can stability in locked internal fixators be controlled? Injury 34(Suppl 2):11–19CrossRef Stoffel K, Dieter U, Stachowiak G, Gachter A, Kuster MS (2003) Biomechanical testing of the LCP—how can stability in locked internal fixators be controlled? Injury 34(Suppl 2):11–19CrossRef
21.
Zurück zum Zitat Stoffel K, Stachowiak G, Kuster M (2004) Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate. Clin Biomech 19:944–950CrossRef Stoffel K, Stachowiak G, Kuster M (2004) Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate. Clin Biomech 19:944–950CrossRef
22.
Zurück zum Zitat Szivek JA, Weng M, Karpman R (1990) Variability in the torsional and bending reponse of a commercially available composite “femur”. J Appl Biomater 1:183–186CrossRef Szivek JA, Weng M, Karpman R (1990) Variability in the torsional and bending reponse of a commercially available composite “femur”. J Appl Biomater 1:183–186CrossRef
23.
Zurück zum Zitat Wagner M (2003) General principles for the clinical use of the LCP. Injury 34(Suppl 2):31–42CrossRef Wagner M (2003) General principles for the clinical use of the LCP. Injury 34(Suppl 2):31–42CrossRef
24.
Zurück zum Zitat Walsh JC, Quinlan JF, Stapleton R, FitzPatrick DP, McCormack D (2007) Three-dimensional motion analysis of the lumbar spine during “free squat” weight lift training. Am J Sports Med 35:927–932PubMedCrossRef Walsh JC, Quinlan JF, Stapleton R, FitzPatrick DP, McCormack D (2007) Three-dimensional motion analysis of the lumbar spine during “free squat” weight lift training. Am J Sports Med 35:927–932PubMedCrossRef
25.
Zurück zum Zitat Zlowodzki M, Williamson S, Cole PA, Zardiackas LD, Kregor PJ (2004) Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures. J Orthop Trauma 8:494–502CrossRef Zlowodzki M, Williamson S, Cole PA, Zardiackas LD, Kregor PJ (2004) Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures. J Orthop Trauma 8:494–502CrossRef
Metadaten
Titel
Axial and torsional stability of supracondylar femur osteotomies: biomechanical comparison of the stability of five different plate and osteotomy configurations
verfasst von
J.-M. Brinkman
C. Hurschler
J. D. Agneskirchner
D. Freiling
R. J. van Heerwaarden
Publikationsdatum
01.04.2011
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 4/2011
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1281-3

Weitere Artikel der Ausgabe 4/2011

Knee Surgery, Sports Traumatology, Arthroscopy 4/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.