Skip to main content
Erschienen in: Radiation Oncology 1/2010

Open Access 01.12.2010 | Research

Early clinical experience with volumetric modulated arc therapy in head and neck cancer patients

verfasst von: Marta Scorsetti, Antonella Fogliata, Simona Castiglioni, Caterina Bressi, Mario Bignardi, Piera Navarria, Pietro Mancosu, Luca Cozzi, Sara Pentimalli, Filippo Alongi, Armando Santoro

Erschienen in: Radiation Oncology | Ausgabe 1/2010

Abstract

Background

To report about early clinical experience in radiation treatment of head and neck cancer of different sites and histology by volumetric modulated arcs with the RapidArc technology.

Methods

During 2009, 45 patients were treated at Istituto Clinico Humanitas with RapidArc (28 males and 17 females, median age 65 years). Of these, 78% received concomitant chemotherapy. Thirty-six patients were treated as exclusive curative intent (group A), three as postoperative curative intent (group B) and six with sinonasal tumours (group C). Dose prescription was at Planning Target Volumes (PTV) with simultaneous integrated boost: 54.45Gy and 69.96Gy in 33 fractions (group A); 54.45Gy and 66Gy in 33 fractions (group B) and 55Gy in 25 fractions (group C).

Results

Concerning planning optimization strategies and constraints, as per PTV coverage, for all groups, D98% > 95% and V95% > 99%. As regards organs at risk, all planning objectives were respected, and this was correlated with observed acute toxicity rates. Only 28% of patients experienced G3 mucositis, 14% G3 dermitis 44% had G2 dysphagia. Nobody required feeding tubes to be placed during treatment. Acute toxicity is also related to chemotherapy. Two patients interrupted the course of radiotherapy because of a quick worsening of general clinical condition.

Conclusions

These preliminary results stated that volumetric modulated arc therapy in locally advanced head and neck cancers is feasible and effective, with acceptable toxicities.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​1748-717X-5-93) contains supplementary material, which is available to authorized users.

Competing interests

Dr. L. Cozzi acts as Scientific Advisor to Varian Medical Systems and is Head of Research and Technological Development to Oncology Institute of Southern Switzerland, Bellinzona.

Authors' contributions

MS and AF coordinated the entire study. Patient accrual and clinical data collection was done by MS, SC, CB, MB, PN, SP. Data analysis, physics data and treatment planning data collection was conducted by AF, PM; clinical data collection was conducted by MS, CB, MB. The manuscript was prepared by AF. All authors read and approved the final manuscript.

Introduction

Radiotherapy (RT), with or without chemotherapy, is the primary treatment modality for head and neck cancer patients. In the last decade intensity modulated radiotherapy (IMRT) has gradually assumed a wide role in the management of such diseases. IMRT has the advantage, over the previously used conformal therapy, of improving normal tissue and organ sparing together with good target coverage. The clear dosimetric benefits were translated to better clinical results in terms of reduction of toxicity, which can improve the quality of life of patient receiving RT, without compromising the probability of tumour control.
Reviews for treatment outcome and major toxicity patterns can be found in Gregoire et al (1), Lee et al (2) and in Popovtzer et al (3) and in references therein. On the toxicity side, besides the attention given to spinal cord and brain stem (with toxicity thresholds of 45-50 Gy for the first and at 50 Gy for the second in most of the investigations), it is consolidated knowledge that, for parotids, mean doses inferior to 25-30 Gy correlate well with substantial recovery of function within two years (Li et al (4), Deasy et al (5)). Higher thresholds were observed for sub-mandibular glands in the range of 39 Gy by Murdoc et al (6), while a dose to oral cavity of about 30Gy for late mucositis was reported by Narayan et al (7). Recently, the wide application of IMRT allowed also investigations on strategies to reduce other common toxicity patterns. As an example, the reduction of dysphagia was correlated by Feng et al (8) and Levendag et al (9) with the irradiation of the swallowing structures as the constrictor muscles.
The same high treatment quality is achievable today with other treatment techniques, as the rather new volumetric modulated arc therapy. One of these solutions is the RapidArc(r) implementation (Varian Medical System, Palo Alto, CA, USA). Based on the original investigation of K. Otto (10), RapidArc(r) was recently introduced in clinical practice in several institutes after an intensive validation at planning level where it was compared to IMRT or other approaches, in a series of studies on various indications (11-20).
RapidArc was also explored for head and neck patients (19-21) demonstrating a dosimetric improvement with respect to the most commonly used IMRT for organs at risk sparing, especially when using two arcs.
At the Istituto Clinico Humanitas, since January 2009, all head and neck patients are treated with RapidArc technology, generally associated with chemotherapy. Aim of the present study is to evaluate the initial clinical experience with head and neck RapidArc patients, in terms of dosimetric analysis and acute toxicity results.

Methods and materials

Patients' selection

This is a single-Institute non randomised retrospective study. Between January and December 2009, 45 patients presenting head and neck tumours, were treated with RapidArc at Istituto Clinico Humanitas. Table 1 shows the descriptive data of the group of patients; this is not a homogeneous cohort, indicating that the aim of the study is to report about early experiences in head and neck with RapidArc, not focussing on specific outcome or toxicity in single subgroups. It includes 28 male and 17 female with a median age of 65 years (range: 28-96 years). The primary sites of disease were oropharynx, larynx and oral cavity. Eleven patients presented a histological type different from squamous cell carcinoma (SCC). Of the SCC patients, 5 presented with stage III, 27 with stage IVA, 1 with stage IVB. Six SCC patients presented a T1/T2 stage and 27 a T3/T4 stage. Considering N parameter in the SCC group, one patient was N0, six patients showed N1 stage, 25 patients showed N2, one patient presented N3. None showed distant metastases. Each patient underwent a pre-treatment evaluation, including a complete history and physical examination, magnetic resonance imaging of head and neck region, direct flexible fibre optic endoscopic examination, chest X-ray or thoracic computed tomography (CT). Positron emission tomography (18-FDG-PET) scans were performed in 6 patients.
Table 1
Summary of patients characteristics at treatment start
Number of patients
 
45
Site
Oral Cavity
Nasopharynx
Oropharynx
Hypopharynx
Larynx
Nasal Cavity and Paranasal Sinuses
Other
7
3
16
1
10
6
2
Histology
Squamous cell carcinoma
Differentiated carcinoma
Undifferentiated carcinoma
Adenoidocistic carcinoma
Estesioneuroblastoma
Sarcomas
34
1
2
3
3
2
Sex
Males
Females
28
17
Age
Performance Status
Median [range]
PS 0
PS 1
PS 2
65 [28, 96] y.o.
28
11
6
Diagnostic imaging
PET
RM
6
45
Stage
II
III
IV
4
8
33
Chemotherapy
No ChT
CDDP
Cetuximab
10
16
19
Radiation Dose Prescription
Group A: 69.96/54.45Gy in 33 fractions
Group B: 66.0/54.45 Gy in 33 fractions
Group C: 55Gy in 25 fractions
36
3
6
Patients were stratified into three groups:
  • Group A: 36 patients treated with exclusive curative intent.
  • Group B: 3 patients treated in a postoperative regimen.
  • Group C: 6 patients presenting sinonasal tumours.
Thirty-five patients received concurrent chemotherapy (ChT): 16 with CDDP 100 mg/mq, day 1, 22, 43 of radiation treatment, and 19 patients with Cetuximab. In patient receiving Cetuximab, administration was initiated one week before RT at loading dose of 400 mg/mq of body surface area over a period of 120 minutes, followed by weekly 60 minute infusion of 250/mq during RT.

Volumes definition and dose prescription

A CT scan was performed for each patient with adjacent 3 mm slices. Patients were scanned in supine position, with personalized head mask.
The Gross Tumour Volume (GTV) was defined as the gross extent of tumour shown by imaging, including all involved (positive) lymph nodes. MRI, and in few cases FDG-PET, were used in the delineation of GTV. On the basis of the primary tumour size and involved nodes, the high-risk Clinical Target Volume (CTV1) was defined as GTV (guided by clinical criteria and FDG-PET imaging whenever available) plus a margin for microscopic spread, and the low-risk Clinical Target Volume (CTV2) included precautionally uninvolved nodes. A margin for Planning Target Volume (PTV) was generated by expanding the CTV by 3 mm in all directions except 6 mm in the cranio-caudal direction.
Organs at risk (OAR) were contoured by the planner and included as follow: spinal cord, brain stem, left and right parotids; larynx and uninvolved oral cavity were outlined whenever not heavily included in the target. Whenever close to the PTV, also left and right eyes, optic nerves, and optic chiasm were drawn. In addition, the Healthy Tissue was defined as the patient's volume included in the CT dataset minus all PTV volumes.
Dose was prescribed to mean PTV dose for the high dose level as follows:
  • Group A: SIB (Simultaneous Integrated Boost) with two dose levels of 54.45Gy and 69.96Gy in 33 fractions (1.65 and 2.12Gy/fraction, respectively). Six of the 36 patients in this group received a three dose level treatment, with an intermediate level of 59.4Gy (1.8Gy/fraction), of limited volume. In the present study this intermediate target was not analyzed.
  • Group B: SIB with two dose levels of 54.45Gy and 66Gy in 33 fractions (1.65 and 2Gy/fraction, respectively).
  • Group C: single dose level of 55Gy in 25 fractions (2.2Gy/fraction).
All patients were treated once a day, 5 days a week.
Plans were optimized for one or two isocentric arcs for a Clinac 2100 equipped with a Millennium-120MLC and beam energy of 6MV. Maximum Dose Rate was set to 600MU/min. Further details on RapidArc technique can be found for example in (12,15).
RapidArc plan optimization (with Progressive Resolution Optimizer II implemented in the Eclipse treatment planning system) was performed requiring PTV coverage of 95%-107%. Concerning OARs the objectives were as following: Spinal cord: D1% < 46Gy; Brain stem: D1% < 54Gy; Parotids (considered separately left and right): V30Gy < 45%, Dmean < 26Gy; Larynx: V40Gy < 50%; Oral cavity (not involved): V40Gy < 50%; Eyes: V40Gy < 50%; Optic nerves and Chiasm: D1% < 50Gy. A general strategy was followed during the optimisation process, setting, as priorities, higher values to targets with respect to organs at risk. In addition to the defined organs at risk, a dummy structure drawn as a shell around the targets was used to confine the dose inside the PTV forcing the surrounding healthy tissues to receive lower doses.
All dose distributions were computed with the Anisotropic Analytical Algorithm (AAA, version 8.6) implemented in the Eclipse planning system with a calculation grid resolution of 2.5 mm.
Daily check of patient positioning was performed for all patients by means of kV-cone beam CT (CBCT) system integrated in the machine.

Data evaluation

Plan quality was analyzed from Dose Volume Histogram (DVH) data.
PTV and CTV (high and low dose levels) coverage was scored through D2% (maximum significant dose), D98% (minimum significant dose), V95%, V107%; homogeneity was defined as D5%-D95%. Dose distribution conformity to PTV was scored as Conformity Index (CI95%), defined as the ratio between the patient's volume receiving at least 95% of the dose prescription, and the volume of related PTV; CI95% was reported for both high and low dose PTVs. Target data analysis was conducted for each group separately.
Concerning OARs, the mean dose, the maximum dose (as D1%) and appropriate values of VxGy (volume receiving at least x Gy) were analyzed, but only findings relative to the plan objectives were reported. About Healthy Tissue, similar parameters were analyzed. To account for hot spots, the External Volume Index (EI) was defined as 100*VD/VPTV, where VD is the volume of Healthy Tissue receiving more than the prescribed low dose, and VPTV is the volume of all PTV. All dosimetric data were reported as average over all the patients (or patients belonging to a specific group); errors refer to one standard deviation. OARs data of Group A and B were analyzed together; presenting irradiation of similar anatomical regions, while Group C was kept separated involving the sinonasal region only, and not the neck areas.
Technical delivery parameters of RapidArc treatments are reported, as well as the beam-on time (defined without inclusion of patient positioning and imaging procedures).
Results of pre-treatment plan quality assurance are reported as Gamma Agreement Index (GAI), defined as the percentage of modulated field area passing the γ-index criteria with thresholds on dose difference ΔD = 3% of the significant maximum dose, and on Distance to Agreement DTA = 3 mm. Measurements and analysis were performed by means of the GLAaS methodology described in (22,23) based on absorbed dose to water derived from EPID measurements.

Toxicity evaluation

All patients were evaluated weekly during the RT course and after the completion of the treatment with a predefined follow-up schedule. The here reported data refer to acute toxicity at the end of RT, scored in terms of mucositis, radiation dermitis and dysphagia, according to the Common Terminology Criteria for Adverse Events (CTCAEv3.0) system developed by the National Cancer Institute.
Toxicity data were stratified in Group A+B and Group C due to the different treatment localization, and also for chemotherapy (CDDP, Cetuximab, no chemotherapy) in order to not mix up toxicity coming from the combination of chemo-radiation treatment (e.g. it is known the high skin toxicity when Cetuximab is administered).

Results

Dosimetric and technical results

Figure 1 shows examples of dose distributions for one patient of Group A and one patient of Group C in axial, coronal and sagittal views. CTVs, PTVs and main OARs are shown as solid lines. Figure 2 presents the mean DVHs for CTV and PTV stratified as high and low dose (targets of patients of Group C are included in the high dose volumes), while Figure 3 reports mean DVHs for OARs and Healthy Tissue, stratified in Group A+B and Group C. Dotted lines represent inter-patient variability at one standard deviation. In figure 2, second row, a better dose homogeneity in the low dose target (both PTV and CTV) is shown for group B with respect to group A. This variation could be ascribed to the relative difference between the two specific dose levels (being 54.45Gy the low dose, 69.96Gy and 66Gy for the high dose in group A and B, respectively): the larger the difference, the more pronounced the DVH tail to higher doses.
Findings from the DVH analysis are reported in Table 2 for targets (CTV and PTV); while in table 3 OARs and Healthy Tissue are presented, including the specific planning objectives.
Table 2
Summary of DVH analysis for PTV
  
Objective
Group A
Group B
Group C
PTV high dose
Volume [cm3]
 
142 ± 119
93 ± 68
144 ± 54
 
Mean [%]
100%
100.2 ± 0.8
100.5 ± 1.0
100.0 ± 0.2
 
D2% [%]
< 107%
104.1 ± 2.0
104.0 ± 2.2
104.4 ± 1.7
 
D5-95% [%]
Minimise
7.2 ± 2.0
7.0 ± 3.4
7.7 ± 2.7
 
D98% [%]
> 95%
94.6 ± 1.5
91.9 ± 6.5
93.6 ± 2.2
 
V95% [%]
100
97.2 ± 2.0
98.9 ± 1.7
96.5 ± 2.4
 
V107% [%]
0
0.7 ± 3.2
0.1 ± 0.2
0.4 ± 0.6
 
CI95%
1
1.21 ± 0.15
1.48 ± 0.43
1.06 ± 0.06
CTV high dose
Volume [cm3]
 
82 ± 43
59 ± 46
103 ± 41
 
Mean [%]
100%
100.9 ± 0.6
101.2 ± 1.3
100.6 ± 0.4
 
D2% [%]
< 107%
104.0 ± 1.2
104.0 ± 2.1
104.4 ± 1.8
 
D5-95% [%]
Minimise
4.6 ± 1.6
4.1 ± 1.8
5.6 ± 2.1
 
D98% [%]
> 95%
97.8 ± 1.1
98.3 ± 1.6
96.6 ± 2.0
 
V95% [%]
100
99.7 ± 0.7
99.6 ± 0.4
99.2 ± 1.1
 
V107% [%]
0
0.2 ± 0.5
0.1 ± 0.1
0.4 ± 0.6
PTV low dose
Volume [cm3]
 
253 ± 139
384 ± 282
 
 
D98% [%]
> 95%
95.1 ± 2.4
94.2 ± 2.6
 
 
V95% [%]
100
97.1 ± 5.0
97.8 ± 1.1
 
 
CI95%
1
1.38 ± 0.16
1.55 ± 0.20
 
CTV low dose
Volume [cm3]
 
184 ± 105
264 ± 178
 
 
D98% [%]
> 95%
100.7 ± 2.8
99.8 ± 2.1
 
 
V95% [%]
100
99.0 ± 4.0
99.7 ± 0.3
 
Table 3
Summary of DVH analysis for OARs
 
Objective
Group A+B
Group C
  
Spinal Cord
D1% [Gy]
46Gy
37.7 ± 6.8 [max 44.2]
22.5 ± 19.8 [max 39.7]
  
Brain Stem
D1% [Gy]
54Gy
25.5 ± 13.0 [max 49.4]
30.2 ± 12.4 [max 48.7]
  
Parotid
Volume [cm3]
 
21 ± 7
24 ± 9
Mean [Gy]
< 26Gy
21.5 ± 6.4 [max 38.2]
14.7 ± 10.2 [max 25.9]
V30Gy [%]
< 45%
24.4 ± 13.7 [max 64.6]
10.5 ± 11.8 [max 26.7]
  
Parotid-PTV
Volume [cm3]
 
20 ± 7
24 ± 10
Mean [Gy]
< 26Gy
19.7 ± 5.6 [max 36.4]
13.8 ± 9.3 [max 25.0]
V30Gy [%]
< 45%
20.4 ± 11.9 [max 61.9]
8.0 ± 8.6 [max 16.8]
  
Oral Cavity
Mean [Gy]
 
28.3 ± 9.8 [max 40.8]
 
V40Gy [%]
< 50%
20.0 ± 15.7 [max 43.2]
 
  
Larynx
Mean [Gy]
 
34.9 ± 6.4 [max 44.3]
 
V40Gy [%]
< 50%
26.6 ± 14.6 [max 42.8]
 
  
Eyes
Mean [Gy]
  
23.5 ± 8.8 [max 43.6]
V40Gy [%]
< 50%
 
10.1 ± 17.5 [max 57.1]
  
Optic Nerves
D1% [Gy]
< 50Gy
 
46.7 ± 6.8 [max 56.3]
  
Chiasm
D1% [Gy]
< 50Gy
 
40.7 ± 9.0 [max 47.4]
  
Healthy tissue
Volume [dm3]
 
12.57 ± 4.56
11.40 ± 6.42
Mean [Gy]
 
6.4 ± 2.9
4.4 ± 2.2
V5Gy [dm3]
 
3.21 ± 1.42
2.36 ± 1.18
V10Gy [dm3]
 
2.45 ± 1.12
1.73 ± 1.00
EI100%
 
0.53 ± 1.26
0.80 ± 0.90
DoseInt [Gy dm3]
 
72.87 ± 25.23
42.78 ± 26.02
Dx% = dose received by the x% of the volume; Vx% = volume receiving at least x% of the prescribed dose; CI = ratio between the patient volume receiving at least 95% of the prescribed dose and the volume of the total PTV. DoseInt = Integral dose, [Gy cm3 103]
Dosimetric data showed a good sparing of OARs as well as good target coverage, with respect to planning objectives for all the included parameters.
The target volume receiving at least 95% of the prescribed dose is higher than 97% for group A and B, while slightly less for group C, due probably to the higher tissue inhomogeneity in ethmoidal regions (with a lot of small cavities); for all groups the V95% mean value of the CTV is higher than 99%.
As regards OARs, the serial organs as spinal cord and brain stem never reached the tolerance level, being the average value of maximum dose well below the tolerance criteria. Concerning parotids, the gland volume included in the PTV was in average 6 ± 8% with a maximum value of 19% (this small overlap is mainly due to the CTV to PTV margin, being only of 3 mm. Moreover it is an internal rule to eventually reduce this margin toward parotids if judged clinically acceptable); one parotid over all glands of all patients was excluded from the analysis having 40% of its volume inside the PTV: in this case it was not considered in the optimisation process to not compromise the target coverage. In average the parotid objectives were largely satisfied, except for three cases, where the mean dose was higher than 30Gy, with only one of those having also V30Gy higher than the goal of 45%, being of 50%. In table 3 data for both structures, Parotid and Parotid-PTV are reported for completeness. Oral cavity and larynx for Group A+B fulfilled widely the requested objectives. For optical apparatus (eyes, optic nerves and chiasm) in Group C patients, the goals were achieved except in one case, where the tolerance values exceeded by about 15%.
Concerning Healthy Tissue, a higher dose bath is delivered to Group A+B patients than Group C, due to higher dose prescriptions, and more difficult target shape, with strong concavities, present in the first group. This is confirmed by the higher CI reported for Groups A and B with respect to Group C.
Technical parameters of the treatments are summarized in table 4: more than 70% of the cases were planned with 2 arcs, but keeping the average delivery time below 2 min. Indeed the dose rate was the dose modulating parameter, being well below 600 MU/min (and consequently the gantry speed was at its maximum value of 4.8 degree/sec). In a large portion of cases the arcs were not set as whole rotation (mean arc length was 312 ± 42 degree), also to avoid, in the most posterior entries, the moving rails that are present in the treatment couch, and that were always positioned to their most internal setting.
Table 4
Technical characteristics of RapidArc plans
Number of arcs
1 (13), 2 (32)
Arcs length [˚]
312 ± 42
Beam energy
6 MV
Delivery time [min]
1.80 ± 0.62
MU/fraction
458 ± 112
MU/Gy
219 ± 51
Dose Rate [MU/min]
264 ± 88
Gantry speed [deg/sec]
4.8 ± 0.0
Collimator angle [˚]
(±)17 ± 6
Mean leaf aperture [cm]
3.0 ± 0.8
Mean CP area [cm2]
44.0 ± 16.8
Mean field area [cm2]
219 ± 93
Gamma Agreement Index 3%,3 mm [%]
96.7 ± 2.1 [90.1, 99.7]
MU: monitor units, CP: control point
Pre-treatment quality assurance of RapidArc arcs resulted in an average gamma agreement index GAI of 96.7 ± 2.1%, higher than the acceptance threshold of 95% set as a reference in our institute. In few cases (three with GAI around 93%, one with GAI 90%) this threshold was not achieved, but plans were accepted after careful evaluation of the location of the discrepancies, as well as the measured/calculated dose profiles. The discrepancies were mainly found in the interleaf regions.

Clinical results

Table 5 reports findings in terms of toxicities. Two patients were not evaluated, because they had unplanned treatment interruption due to rapid worsening of general conditions.
Table 5
Acute toxicity
  
All
No chemoth.
CDDP
Cetuximab
Group
A
B
C
36
3
6
4
1
5
13
2
1
19
0
0
Completion of RT
Completed
Interrupted
43
2
10
0
16
0
17
2
Mucositis
G0
G1
G2
G3
6
17
8
12
5
3
1
1
1
9
4
2
0
5
3
9
Dermitis
G0
G1
G2
G3
6
20
11
6
6
3
1
0
0
13
3
0
0
4
7
6
Dysphagia
G0
G1
G2
G3
10
11
19
3
5
2
2
1
3
6
7
0
2
3
10
2
In the group of the analyzed patients, no grade 4 acute toxicity was observed. The most common acute G3 toxicities were mucositis (28%), followed by dermitis (14%) and dysphagia (7%). Nevertheless, no patients required percutaneous gastrotomy or feedings tubes. Stratifying patients according to chemotherapy modality, patients treated with Cetuximab presented the majority of G3 toxicities not only for mucositis but also for dermitis and dysphagia. To notice is the peak of toxicity for Cetuximab patients, shifted to G2 or G3 (whichever the toxicity), while for CDDP patients the peak is mainly at G1. To consider is the fact that patients receiving Cetuximab had in average a worse performance status at the beginning of RT: mean performance status value of Cetuximab patients was 0.9, with respect to an average of 0.2 of groups receiving CDDP or no chemotherapy. Concerning compliance, 43 of 45 patients completed treatment (treatment interruption occurred in two patients treated with Cetuximab).
Late toxicity was not assessed in this investigation because of short follow-up. Preliminary clinical results are here reported: at first evaluations, after 2 and 6 months, 31 patients were followed, while 30% of the initial 45 patients had not first evaluation. Twenty-three patients presented complete remission (74%), 5 presented partial remission (16%), and 3 presented stable disease (10%), according to WHO of Response Evaluation Criteria in solid Tumors-RECIST-Group. To underline is that 100% of patients who received CDDP presented complete remission, while this occurred to 56% of patients treated with Cetuximab.

Discussion

The initial experience of the Istituto Clinico Humanitas on RapidArc technology applied to 45 head and neck patients confirmed the findings of good dosimetric results and of toxicity, as well as the reliability and efficacy of the RapidArc modality as anticipated in dosimetric investigations (19-21).
From the dosimetric viewpoint, presenting Group A+B and Group C distinct anatomical locations, the analysis at the level of OARs has been shown separately in order to not confound global results. Avoiding this bias, the general conclusion of a safe sparing of the parotids for Group A+B is supported, being the mean dose was well below the threshold proposed by Eisbruch et al (24) of 26Gy (and subsequent studies (4, 5)). This would suggest an acceptable degree of xerostomia with related acceptable quality of life, with good probability of a substantial preservation of the saliva flow rate. Published examples of clinical experience with IMRT, such as e.g. de Arruda et al (25), Chao et al (26), and Eisbruch et al (24), show improvement of this parotid related parameter, with values of 25 ± 4 Gy.
The intensity modulated techniques - fixed gantry fields and modulated arcs - allowed, since their initial appearance, the treatment of SIB with the therapy delivered to various dose levels with the same plan. The increase in dose/fraction for the high dose level does not correspond to an increase of dose to the OARs (27). This opportunity is widely used for head and neck cancers, differentiating the high risk, intermediate (if any), and low risk of recurrence.
The usage of one or two arcs is related especially to the target and patient anatomy complexity. Generally, with SIB approach, the usage of two arcs is preferable, as also pointed out by Verbakel et al (19) to improve target dose homogeneity and Vanetti et al (20) to improve OARs sparing. In our patient population about two third received two arcs. The small extra time needed to re-program the linac for the second arc, and to deliver the second arc (generally less than 74 sec) is anyway largely inferior to the time needed to deliver such treatments with IMRT. For example a dual arc RapidArc treatment takes about three minutes, while a seven fixed gantry IMRT fields (often splitted) takes approximately 15 minutes to be delivered. This, in terms of patient comfort under the fixation mask, is one of the significant advantages in using the RapidArc technology for head and neck patients. With RapidArc treatment those patients can be easily treated with good dose distributions in a time slot of 10 minutes, including also the time needed to perform a good imaging through a 2D-2D matching (with kV-kV or kV-MV images) or a CBCT. At Istituto Clinico Humanitas a CBCT is acquired before every fraction, keeping the time slot of 10 minutes, following specific internal protocol of quality assurance in terms of patient positioning. This procedure gives confidence in patient treatments allowing the usage of rather small CTV to PTV margins. Moreover, in the head and neck region, clinicians can easily detect tumour variations of the patient volume and anatomy.
In terms of planning time, it could be roughly estimated in about one hour for RapidArc (those have not to be considered as definitive time values because they are dependent on planner, usage of pre-defined objective templates, hardware performances), or half an hour for IMRT with fixed gantry entrances. To consider in the frame of time spent to the treatment preparation there is also the pre-treatment QA process that, with respect to IMRT, has for RapidArc a shorter time due to the limited number of arcs or fields to check.
With respect to pre-treatment QA, head and neck plans with RapidArc showed to be reliable in terms of dose calculation, being within tolerance in the majority of the cases. The here shown data are coherent with what reported in literature for the pre-clinical planning studies, where also some findings concerning delivery was reported. For example the study on head and neck cases published by Verbakel et al (19) showed agreement higher than 97% using films and gamma criteria of DTA = 2 mm and ΔD = 3%; Nicolini et al (28) reported agreement around 99% for the same criteria adopted in the present study, using both GLAaS method and Seven29 2D-array (PTW) inside the Octavius phantom for RapidArc bilateral breast cases. Concerning the here presented clinical cases, the average GAI of almost 97% demonstrates the robustness of the delivery in a clinical environment. As described in the Result section, the few cases out of the acceptability level were deeply and critically analyzed and understood before treating the patients. To notice is the locations of the failing points, being in the interleaf spaces, where the high resolution of the detector (EPID) emphasizes the difficulties of the treatment planning system in properly manage the interleaf leakage and tongue and groove effect. It is also for this reason that the collimator is rotated during the arc, in order to smear the effect inside the patient without causing any valuable effect in terms of dose distribution.
On the clinical side data are here reported on acute side effects for patients treated with RapidArc with or without chemotherapy, and on early and preliminary results on local control.
All patients completed RT treatment, except two cases that started in bad general conditions at enrolment; evaluating concomitant chemo-radiotherapy, all patients received the planned number of chemotherapy cycles. Only in the group of patients receiving Cetuximab there were treatment breaks, but not longer than one week. Low grade of mucositis and dermitis, and moderate grade of dysphagia were the most prevalent acute toxicities, whereas mucositis severe enough to necessitate gastrotomy or feeding tube were not present. Data regarding the prevalent toxicities in Cetuximab's patients must be read considering that patients with a low performance status or unfit were enrolled to receive Cetuximab.
Often high grade acute toxicities do not allow completing the planned concomitant treatment. With the advent of IMRT, the possibility to obtain highly conformal dose distributions around the tumour volume, while sparing the nearby sensitive structures has greatly improved. The question of whether this dosimetric improvement creates less acute toxicities remains open. By our experience, RapidArc is able to determine low grade acute side effects and permits to associate concomitant chemotherapy. Excluding dose painting impact of IMRT, in reducing OAR involvements as well as acute toxicities, another possible reason of high tolerability in our patient population could be ascribed to the intense frequency of clinical controls during treatments. It is an our policy to check patients more than once per week in order to detect acute side effects as early as possible and prescribe personalized supportive care during radio-chemotherapy, also avoiding or minimizing interruptions.

Conclusion

Forty-five patients presenting head and neck cancer were treated with Volumetric Modulated Arc Therapy according to the RapidArc implementation at Istituto Clinico Humanitas during 2009. Quality of treatments resulted in a general fulfilment of planning objectives. Clinical outcome for early acute toxicity showed, as expected, higher toxicity levels for skin and mucosa reactions in patients receiving concomitant Cetuximab chemotherapy. Future investigations will aim to assess at long term definitive outcome, having this first phase achieved the primary goal to demonstrate safety and efficacy of RapidArc.
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://​creativecommons.​org/​licenses/​by/​2.​0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interests

Dr. L. Cozzi acts as Scientific Advisor to Varian Medical Systems and is Head of Research and Technological Development to Oncology Institute of Southern Switzerland, Bellinzona.

Authors' contributions

MS and AF coordinated the entire study. Patient accrual and clinical data collection was done by MS, SC, CB, MB, PN, SP. Data analysis, physics data and treatment planning data collection was conducted by AF, PM; clinical data collection was conducted by MS, CB, MB. The manuscript was prepared by AF. All authors read and approved the final manuscript.
Anhänge

Authors’ original submitted files for images

Literatur
1.
Zurück zum Zitat Gregoire V, De Neve W, Eisbruch A, Lee N, Vanden Weyngaert D, Van Gestel D: Intensity modulated radiation therapy for head and neck carcinoma. The Oncologist 2007, 12: 555-564. 10.1634/theoncologist.12-5-555CrossRefPubMed Gregoire V, De Neve W, Eisbruch A, Lee N, Vanden Weyngaert D, Van Gestel D: Intensity modulated radiation therapy for head and neck carcinoma. The Oncologist 2007, 12: 555-564. 10.1634/theoncologist.12-5-555CrossRefPubMed
2.
Zurück zum Zitat Lee N, Puri D, Blanco AI, Chao KS: Intensity modulated radiathion therapy in head and neck cancers: an update. Head and Neck 2007, 29: 387-400. 10.1002/hed.20332CrossRefPubMed Lee N, Puri D, Blanco AI, Chao KS: Intensity modulated radiathion therapy in head and neck cancers: an update. Head and Neck 2007, 29: 387-400. 10.1002/hed.20332CrossRefPubMed
3.
Zurück zum Zitat Popovtzer A, Eisbruch A: Advances in radiation therapy of head and neck cancer. Expert Rev Anticancer Ther 2008, 8: 633-644. 10.1586/14737140.8.4.633CrossRefPubMed Popovtzer A, Eisbruch A: Advances in radiation therapy of head and neck cancer. Expert Rev Anticancer Ther 2008, 8: 633-644. 10.1586/14737140.8.4.633CrossRefPubMed
4.
Zurück zum Zitat Li Y, Ten Haken R, Eisbruch A: The impact of dose on parotid recovery in head and neck cancer patients treated with radiation therapy. Int J Radiat Oncol Biol Phys 2007, 67: 660-669.PubMedCentralCrossRefPubMed Li Y, Ten Haken R, Eisbruch A: The impact of dose on parotid recovery in head and neck cancer patients treated with radiation therapy. Int J Radiat Oncol Biol Phys 2007, 67: 660-669.PubMedCentralCrossRefPubMed
5.
Zurück zum Zitat Deasy JO, Moiseenko V, Marks L, Chao KS, Nam J, Eisbruch A: Radiotherapy dose-volume effects on salivary gland function. Int J Radiat Oncol Biol Phys 2010,76(l):S58-63.PubMedCentralCrossRefPubMed Deasy JO, Moiseenko V, Marks L, Chao KS, Nam J, Eisbruch A: Radiotherapy dose-volume effects on salivary gland function. Int J Radiat Oncol Biol Phys 2010,76(l):S58-63.PubMedCentralCrossRefPubMed
6.
Zurück zum Zitat Murdoch-Kinch C, Kim H, Vineberg K, Ship J, Eisbruch A: Dose effect relationships for the submandibular salivary glands and implications for their sparing by intensity modulated radiotherapy. Int J Radiat Oncol Biol Phys 2008, 72: 373-382.PubMedCentralCrossRefPubMed Murdoch-Kinch C, Kim H, Vineberg K, Ship J, Eisbruch A: Dose effect relationships for the submandibular salivary glands and implications for their sparing by intensity modulated radiotherapy. Int J Radiat Oncol Biol Phys 2008, 72: 373-382.PubMedCentralCrossRefPubMed
7.
Zurück zum Zitat Narayan S, Lehmann J, Coleman MA, Vaughan A, Yang CC, Enepekides D, Farwell G, Purdy JA, Laredo G, Nolan K, Pearson FS, Vijayakumar S: Prospective evaluation to establish a dose response for clinical oral mucositis in patients undergoing head-and-neck conformal radiotherapy. Int J Radiat Oncol Biol Phys 2008, 72: 756-762.CrossRefPubMed Narayan S, Lehmann J, Coleman MA, Vaughan A, Yang CC, Enepekides D, Farwell G, Purdy JA, Laredo G, Nolan K, Pearson FS, Vijayakumar S: Prospective evaluation to establish a dose response for clinical oral mucositis in patients undergoing head-and-neck conformal radiotherapy. Int J Radiat Oncol Biol Phys 2008, 72: 756-762.CrossRefPubMed
8.
Zurück zum Zitat Feng F, Kim H, Lyden T, Feng M, Chepeha D, Eisbruch A: Intensity modulated radiotherapy of head and neck cancer aiming to reduce dysphagia: early dose-effect relationships for the swallowing structures. Int J Radiat Oncol Biol Phys 2007, 68: 1289-1298.CrossRefPubMed Feng F, Kim H, Lyden T, Feng M, Chepeha D, Eisbruch A: Intensity modulated radiotherapy of head and neck cancer aiming to reduce dysphagia: early dose-effect relationships for the swallowing structures. Int J Radiat Oncol Biol Phys 2007, 68: 1289-1298.CrossRefPubMed
9.
Zurück zum Zitat Levendag PC, Teguh DN, Voet P, van der Est H, Noever I, de Kruijf WJ, Kolkman-Deurloo IK, Prevost JB, Poll J, Schmitz PI, Heijmen BJ: Dysphagia disorders in patients with cancer of the oropharynx are significantly affected by the radiation therapy dose to the superior and middle constrictor muscle: a dose-effect relationship. Radiother Oncol 2007, 85: 64-73. 10.1016/j.radonc.2007.07.009CrossRefPubMed Levendag PC, Teguh DN, Voet P, van der Est H, Noever I, de Kruijf WJ, Kolkman-Deurloo IK, Prevost JB, Poll J, Schmitz PI, Heijmen BJ: Dysphagia disorders in patients with cancer of the oropharynx are significantly affected by the radiation therapy dose to the superior and middle constrictor muscle: a dose-effect relationship. Radiother Oncol 2007, 85: 64-73. 10.1016/j.radonc.2007.07.009CrossRefPubMed
10.
Zurück zum Zitat Otto K: Volumetric Modulated Arc Therapy: IMRT in a single arc. Med Phys 2008, 35: 310-317. 10.1118/1.2818738CrossRefPubMed Otto K: Volumetric Modulated Arc Therapy: IMRT in a single arc. Med Phys 2008, 35: 310-317. 10.1118/1.2818738CrossRefPubMed
11.
Zurück zum Zitat Lagerwaard F, Meijer O, van der Hoorn E, Verbakel W, Slotman B, Senan S: Volumetric modulated arc radiotherapy for vestibular schwannomas. Int J Radiat Oncol Biol Phys 2009, 74: 610-615.CrossRefPubMed Lagerwaard F, Meijer O, van der Hoorn E, Verbakel W, Slotman B, Senan S: Volumetric modulated arc radiotherapy for vestibular schwannomas. Int J Radiat Oncol Biol Phys 2009, 74: 610-615.CrossRefPubMed
12.
Zurück zum Zitat Fogliata A, Clivio A, Nicolini G, Vanetti E, Cozzi L: Intensity modulation with photons for benign intracranial tumors: a planning comparison of volumetric single arc, helical arc and fixed gantry techniques. Radiother Oncol 2008, 89: 254-262. 10.1016/j.radonc.2008.07.021CrossRefPubMed Fogliata A, Clivio A, Nicolini G, Vanetti E, Cozzi L: Intensity modulation with photons for benign intracranial tumors: a planning comparison of volumetric single arc, helical arc and fixed gantry techniques. Radiother Oncol 2008, 89: 254-262. 10.1016/j.radonc.2008.07.021CrossRefPubMed
13.
Zurück zum Zitat Kjær-Kristoffersen F, Ohlhues L, Medin J, Korreman S: RapidArc volumetric modulated therapy planning for prostate cancer patients. Acta Oncol 2009, 48: 227-232. 10.1080/02841860802266748CrossRefPubMed Kjær-Kristoffersen F, Ohlhues L, Medin J, Korreman S: RapidArc volumetric modulated therapy planning for prostate cancer patients. Acta Oncol 2009, 48: 227-232. 10.1080/02841860802266748CrossRefPubMed
14.
Zurück zum Zitat Clivio A, Fogliata A, Franzetti-Pellanda A, Nicolini G, Vanetti E, Wyttenbach R, Cozzi L: Volumetric-modulated arc radiotherapy for carcinomas of the anal canal: A treatment planning comparison with fixed field IMRT. Radiother Oncol 2009, 92: 118-124. 10.1016/j.radonc.2008.12.020CrossRefPubMed Clivio A, Fogliata A, Franzetti-Pellanda A, Nicolini G, Vanetti E, Wyttenbach R, Cozzi L: Volumetric-modulated arc radiotherapy for carcinomas of the anal canal: A treatment planning comparison with fixed field IMRT. Radiother Oncol 2009, 92: 118-124. 10.1016/j.radonc.2008.12.020CrossRefPubMed
15.
Zurück zum Zitat Cozzi L, Dinshaw KA, Shrivastava SK, Mahantshetty U, Engineer R, Deshpande DD, Jamema SV, Vanetti E, Clivio A, Nicolini G, Fogliata A: A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. Radiother Oncol 2008, 89: 180-191. 10.1016/j.radonc.2008.06.013CrossRefPubMed Cozzi L, Dinshaw KA, Shrivastava SK, Mahantshetty U, Engineer R, Deshpande DD, Jamema SV, Vanetti E, Clivio A, Nicolini G, Fogliata A: A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. Radiother Oncol 2008, 89: 180-191. 10.1016/j.radonc.2008.06.013CrossRefPubMed
16.
Zurück zum Zitat Scorsetti M, Bignardi M, Clivio A, Cozzi L, Fogliata A, Lattuada P, Mancosu P, Navarria P, Nicolini G, Urso G, Vanetti E, Vogorito S, Santoro A: Volumetric modulation arc radiotherapy compared with static gantry IMRT for malignant pleural mesothelioma tumor: a feasibility study. Int J Radiat Oncol Biol Phys 2010, 77: 942-949.CrossRefPubMed Scorsetti M, Bignardi M, Clivio A, Cozzi L, Fogliata A, Lattuada P, Mancosu P, Navarria P, Nicolini G, Urso G, Vanetti E, Vogorito S, Santoro A: Volumetric modulation arc radiotherapy compared with static gantry IMRT for malignant pleural mesothelioma tumor: a feasibility study. Int J Radiat Oncol Biol Phys 2010, 77: 942-949.CrossRefPubMed
17.
Zurück zum Zitat Mancosu P, Navarria P, Bignardi M, Cozzi L, Fogliata A, Lattuada P, Santoro A, Urso G, Vigorito S, Scorsetti M: Re-irradiation of metastatic spinal cord compression: A feasibility study by volumetric-modulated arc radiotherapy for in-field recurrence creating a dosimetric hole on the central canal. Radiother Oncol 2009, 94: 67-70. 10.1016/j.radonc.2009.11.010CrossRefPubMed Mancosu P, Navarria P, Bignardi M, Cozzi L, Fogliata A, Lattuada P, Santoro A, Urso G, Vigorito S, Scorsetti M: Re-irradiation of metastatic spinal cord compression: A feasibility study by volumetric-modulated arc radiotherapy for in-field recurrence creating a dosimetric hole on the central canal. Radiother Oncol 2009, 94: 67-70. 10.1016/j.radonc.2009.11.010CrossRefPubMed
18.
Zurück zum Zitat Bignardi M, Cozzi L, Fogliata A, Lattuada P, Mancosu P, Navarria P, Urso G, Vigorito S, Scorsetti M: Critical appraisal of volumetric modulated arc therapy in stereotactic body radiation therapy for metastases to abdominal lymph nodes. Int J Radiat Oncol Biol Phys 2009, 75: 1570-1577.CrossRefPubMed Bignardi M, Cozzi L, Fogliata A, Lattuada P, Mancosu P, Navarria P, Urso G, Vigorito S, Scorsetti M: Critical appraisal of volumetric modulated arc therapy in stereotactic body radiation therapy for metastases to abdominal lymph nodes. Int J Radiat Oncol Biol Phys 2009, 75: 1570-1577.CrossRefPubMed
19.
Zurück zum Zitat Verbakel W, Cuijpers J, Hoffmans D, Bieker M, Slotman B: Volumetric intensity modulated arc therapy versus conventional IMRT in head and neck cancer: A comparative planning and dosimetric study. Int J Radiat Oncol Biol Phys 2009, 74: 252-259.CrossRefPubMed Verbakel W, Cuijpers J, Hoffmans D, Bieker M, Slotman B: Volumetric intensity modulated arc therapy versus conventional IMRT in head and neck cancer: A comparative planning and dosimetric study. Int J Radiat Oncol Biol Phys 2009, 74: 252-259.CrossRefPubMed
20.
Zurück zum Zitat Vanetti E, Clivio A, Nicolini G, Fogliata A, Ghosh-Laskar S, Agarwal JP, Upreti RR, Budrukkar A, Murthy V, Deshpande DD, Shrivastava SK, Dinshaw KA, Cozzi L: Volumetric modulated arc radiotherapy for carcinomas of the oro-pharynx, hypo-pharynx and larynx: a treatment planning comparison with fixed field IMRT. Radiother Oncol 2009, 92: 111-117. 10.1016/j.radonc.2008.12.008CrossRefPubMed Vanetti E, Clivio A, Nicolini G, Fogliata A, Ghosh-Laskar S, Agarwal JP, Upreti RR, Budrukkar A, Murthy V, Deshpande DD, Shrivastava SK, Dinshaw KA, Cozzi L: Volumetric modulated arc radiotherapy for carcinomas of the oro-pharynx, hypo-pharynx and larynx: a treatment planning comparison with fixed field IMRT. Radiother Oncol 2009, 92: 111-117. 10.1016/j.radonc.2008.12.008CrossRefPubMed
21.
Zurück zum Zitat Doornaert P, Verbakel W, Bieker M, Slotman BJ, Senan S: RapidArc planning and delivery in patients with locally advanced head-and-neck cancer undergoing chemoradiotherapy. Int J Radiat Oncol Biol Phys 2010, in press. Doornaert P, Verbakel W, Bieker M, Slotman BJ, Senan S: RapidArc planning and delivery in patients with locally advanced head-and-neck cancer undergoing chemoradiotherapy. Int J Radiat Oncol Biol Phys 2010, in press.
22.
Zurück zum Zitat Nicolini G, Fogliata A, Vanetti E, Clivio A, Cozzi L: GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications. Med Phys 2006, 33: 2839-2851. 10.1118/1.2218314CrossRefPubMed Nicolini G, Fogliata A, Vanetti E, Clivio A, Cozzi L: GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications. Med Phys 2006, 33: 2839-2851. 10.1118/1.2218314CrossRefPubMed
23.
Zurück zum Zitat Nicolini G, Vanetti E, Clivio A, Fogliata A, Korreman S, Bocanek J, Cozzi L: The GLAaS algoritm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy. Radiat Oncol 2008, 3: 24. 10.1186/1748-717X-3-24PubMedCentralCrossRefPubMed Nicolini G, Vanetti E, Clivio A, Fogliata A, Korreman S, Bocanek J, Cozzi L: The GLAaS algoritm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy. Radiat Oncol 2008, 3: 24. 10.1186/1748-717X-3-24PubMedCentralCrossRefPubMed
24.
Zurück zum Zitat Eisbruch A, Ten Haken RK, Kim HM, Marsh LH, Ship JA: Dose, volume and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head and neck cancer. Int J Radiat Oncol Biol Phys 1999, 45: 577-587.CrossRefPubMed Eisbruch A, Ten Haken RK, Kim HM, Marsh LH, Ship JA: Dose, volume and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head and neck cancer. Int J Radiat Oncol Biol Phys 1999, 45: 577-587.CrossRefPubMed
25.
Zurück zum Zitat de Arruda FF, Puri DR, Zhung J, Narayana A, Wolden S, Hunt M, Stambuk H, Pfister D, Kraus D, Shaha A, Shah J, Lee NY: Intensity-modulated radiation therapy for the treatment of oropharyngeal carcinoma: the Memorial Sloan-Kattering Cancer Center experience. Int J Radiat Oncol Biol Phys 2006, 64: 363-373.CrossRefPubMed de Arruda FF, Puri DR, Zhung J, Narayana A, Wolden S, Hunt M, Stambuk H, Pfister D, Kraus D, Shaha A, Shah J, Lee NY: Intensity-modulated radiation therapy for the treatment of oropharyngeal carcinoma: the Memorial Sloan-Kattering Cancer Center experience. Int J Radiat Oncol Biol Phys 2006, 64: 363-373.CrossRefPubMed
26.
Zurück zum Zitat Chao KS, Deasy JO, Markman J, Haynie J, Perez CA, Purdy JA, Low DA: A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: initial results. Int J Radiat Oncol Biol Phys 2001, 29: 907-918.CrossRef Chao KS, Deasy JO, Markman J, Haynie J, Perez CA, Purdy JA, Low DA: A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: initial results. Int J Radiat Oncol Biol Phys 2001, 29: 907-918.CrossRef
27.
Zurück zum Zitat Fogliata A, Bolsi A, Cozzi L, Bernier J: Comparative dosimetric evaluation of the simultaneous integrated boost with photon intensity modulation in head and neck cancer patients. Radiother Oncol 2003, 69: 267-275. 10.1016/j.radonc.2003.10.003CrossRefPubMed Fogliata A, Bolsi A, Cozzi L, Bernier J: Comparative dosimetric evaluation of the simultaneous integrated boost with photon intensity modulation in head and neck cancer patients. Radiother Oncol 2003, 69: 267-275. 10.1016/j.radonc.2003.10.003CrossRefPubMed
28.
Zurück zum Zitat Nicolini G, Clivio A, Fogliata A, Vanetti E, Cozzi L: Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity modulated therapy. Radiat Oncol 2009, 4: 27. 10.1186/1748-717X-4-27PubMedCentralCrossRefPubMed Nicolini G, Clivio A, Fogliata A, Vanetti E, Cozzi L: Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity modulated therapy. Radiat Oncol 2009, 4: 27. 10.1186/1748-717X-4-27PubMedCentralCrossRefPubMed
Metadaten
Titel
Early clinical experience with volumetric modulated arc therapy in head and neck cancer patients
verfasst von
Marta Scorsetti
Antonella Fogliata
Simona Castiglioni
Caterina Bressi
Mario Bignardi
Piera Navarria
Pietro Mancosu
Luca Cozzi
Sara Pentimalli
Filippo Alongi
Armando Santoro
Publikationsdatum
01.12.2010
Verlag
BioMed Central
Erschienen in
Radiation Oncology / Ausgabe 1/2010
Elektronische ISSN: 1748-717X
DOI
https://doi.org/10.1186/1748-717X-5-93

Weitere Artikel der Ausgabe 1/2010

Radiation Oncology 1/2010 Zur Ausgabe

Adjuvante Immuntherapie verlängert Leben bei RCC

25.04.2024 Nierenkarzinom Nachrichten

Nun gibt es auch Resultate zum Gesamtüberleben: Eine adjuvante Pembrolizumab-Therapie konnte in einer Phase-3-Studie das Leben von Menschen mit Nierenzellkarzinom deutlich verlängern. Die Sterberate war im Vergleich zu Placebo um 38% geringer.

Alectinib verbessert krankheitsfreies Überleben bei ALK-positivem NSCLC

25.04.2024 NSCLC Nachrichten

Das Risiko für Rezidiv oder Tod von Patienten und Patientinnen mit reseziertem ALK-positivem NSCLC ist unter einer adjuvanten Therapie mit dem Tyrosinkinase-Inhibitor Alectinib signifikant geringer als unter platinbasierter Chemotherapie.

Bei Senioren mit Prostatakarzinom auf Anämie achten!

24.04.2024 DGIM 2024 Nachrichten

Patienten, die zur Behandlung ihres Prostatakarzinoms eine Androgendeprivationstherapie erhalten, entwickeln nicht selten eine Anämie. Wer ältere Patienten internistisch mitbetreut, sollte auf diese Nebenwirkung achten.

ICI-Therapie in der Schwangerschaft wird gut toleriert

Müssen sich Schwangere einer Krebstherapie unterziehen, rufen Immuncheckpointinhibitoren offenbar nicht mehr unerwünschte Wirkungen hervor als andere Mittel gegen Krebs.

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.