Skip to main content
Erschienen in: Pediatric Radiology 12/2022

22.04.2022 | Original Article

Percutaneous ultrasound-guided renal biopsies in a paediatric population: comparison of coaxial and non-coaxial techniques using 18-gauge core biopsy needles

verfasst von: Kin Fen Kevin Fung, Ka King Cheng, Eugene Yu-Hin Chan, Lap Tak Alison Ma, Hing Yan Danny Cho, Yee Ling Elaine Kan

Erschienen in: Pediatric Radiology | Ausgabe 12/2022

Einloggen, um Zugang zu erhalten

Abstract

Background

Percutaneous ultrasound-guided biopsy is performed in paediatric patients for evaluation of diffuse renal parenchymal disease. When compared with the non-coaxial technique, the coaxial technique has the advantages of obtaining multiple tissue cores via a single capsular puncture and post-biopsy tract embolisation.

Objectives

To compare the coaxial and non-coaxial techniques of percutaneous ultrasound (US)-guided biopsy of native kidney parenchyma in children and adolescents with renal disease.

Materials and methods

We retrospectively identified consecutive patients who underwent percutaneous US-guided renal biopsy using an 18-gauge core biopsy needle from July 2019 to July 2021 in a single tertiary paediatric nephrology centre. Focal renal tumour biopsy and transplant kidney biopsy were excluded. The total glomerular yield, specimen adequacy, complication rate and procedural time between the coaxial and non-coaxial groups were compared.

Results

There were 34 percutaneous US-guided renal biopsies: 22 using a coaxial technique and 12 using a non-coaxial technique. The total median glomerular yield obtained was higher in the coaxial group (coaxial=37.9; non-coaxial=22.2; P=0.02). No statistically significant difference was noted between specimen adequacy (coaxial=100%; non-coaxial=91.7%; P=0.35). While no statistically significant difference was detected for overall complication rates (coaxial=13.6%; non-coaxial=41.7%; P=0.09), the coaxial group had a lower rate of haemorrhagic complications (coaxial=4.5%; non-coaxial=41.7%; P=0.01). One patient in the non-coaxial group had post-biopsy haemorrhage requiring embolisation. The procedural time was shorter in the coaxial group (coaxial=26.3 ± 7.0 min; non-coaxial=51.3 ± 11.5 min; P<0.001).

Conclusion

Percutaneous US-guided renal biopsy in children using the coaxial technique has significantly higher total glomerular yield, shorter procedural time and fewer haemorrhagic complications, compared to biopsies using the non-coaxial technique.
Literatur
1.
Zurück zum Zitat Towbin RB, Baskin K (2015) Pediatric interventional radiology. Cambridge University Press, CambridgeCrossRef Towbin RB, Baskin K (2015) Pediatric interventional radiology. Cambridge University Press, CambridgeCrossRef
2.
Zurück zum Zitat Sheth RA, Baerlocher MO, Connolly BL et al (2020) Society of Interventional Radiology quality improvement standards on percutaneous needle biopsy in adult and pediatric patients. J Vasc Interv Radiol 31:1840–1848CrossRefPubMed Sheth RA, Baerlocher MO, Connolly BL et al (2020) Society of Interventional Radiology quality improvement standards on percutaneous needle biopsy in adult and pediatric patients. J Vasc Interv Radiol 31:1840–1848CrossRefPubMed
4.
Zurück zum Zitat Hatfield MK, Beres RA, Sane SS et al (2008) Percutaneous imaging-guided solid organ core needle biopsy: coaxial versus noncoaxial method. AJR Am J Roentgenol 190:413–417CrossRefPubMed Hatfield MK, Beres RA, Sane SS et al (2008) Percutaneous imaging-guided solid organ core needle biopsy: coaxial versus noncoaxial method. AJR Am J Roentgenol 190:413–417CrossRefPubMed
5.
Zurück zum Zitat McDonald J, Amirabadi A, Farhat Z et al (2019) Experience with compressed gelfoam plugs in children during liver biopsies and other IR procedures: a retrospective single-center case series. J Vasc Interv Radiol 30:1855–1862CrossRefPubMed McDonald J, Amirabadi A, Farhat Z et al (2019) Experience with compressed gelfoam plugs in children during liver biopsies and other IR procedures: a retrospective single-center case series. J Vasc Interv Radiol 30:1855–1862CrossRefPubMed
6.
Zurück zum Zitat Babaei Jandaghi A, Lebady M, Zamani AA et al (2017) A randomised clinical trial to compare coaxial and noncoaxial techniques in percutaneous core needle biopsy of renal parenchyma. Cardiovasc Intervent Radiol 40:106–111CrossRefPubMed Babaei Jandaghi A, Lebady M, Zamani AA et al (2017) A randomised clinical trial to compare coaxial and noncoaxial techniques in percutaneous core needle biopsy of renal parenchyma. Cardiovasc Intervent Radiol 40:106–111CrossRefPubMed
7.
Zurück zum Zitat Uppot RN, Harisinghani MG, Gervais DA (2010) Imaging-guided percutaneous renal biopsy: rationale and approach. AJR Am J Roentgenol 194:1443–1449CrossRefPubMed Uppot RN, Harisinghani MG, Gervais DA (2010) Imaging-guided percutaneous renal biopsy: rationale and approach. AJR Am J Roentgenol 194:1443–1449CrossRefPubMed
8.
Zurück zum Zitat Fotiadis N, De Paepe KN, Bonne L et al (2020) Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk. Eur Radiol 30:6702–6708CrossRefPubMedPubMedCentral Fotiadis N, De Paepe KN, Bonne L et al (2020) Comparison of a coaxial versus non-coaxial liver biopsy technique in an oncological setting: diagnostic yield, complications and seeding risk. Eur Radiol 30:6702–6708CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Robbins KA, Keet CA (2015) Intraoperative anaphylaxis likely due to Gelfoam in a pediatric patient undergoing liver biopsy. Ann Allergy Asthma Immunol 114:531–533CrossRefPubMed Robbins KA, Keet CA (2015) Intraoperative anaphylaxis likely due to Gelfoam in a pediatric patient undergoing liver biopsy. Ann Allergy Asthma Immunol 114:531–533CrossRefPubMed
10.
Zurück zum Zitat Mai J, Yong J, Dixson H et al (2013) Is bigger better? A retrospective analysis of native renal biopsies with 16 gauge versus 18 gauge automatic needles. Nephrol (Carlton) 18:525–530CrossRef Mai J, Yong J, Dixson H et al (2013) Is bigger better? A retrospective analysis of native renal biopsies with 16 gauge versus 18 gauge automatic needles. Nephrol (Carlton) 18:525–530CrossRef
Metadaten
Titel
Percutaneous ultrasound-guided renal biopsies in a paediatric population: comparison of coaxial and non-coaxial techniques using 18-gauge core biopsy needles
verfasst von
Kin Fen Kevin Fung
Ka King Cheng
Eugene Yu-Hin Chan
Lap Tak Alison Ma
Hing Yan Danny Cho
Yee Ling Elaine Kan
Publikationsdatum
22.04.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 12/2022
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-022-05359-x

Weitere Artikel der Ausgabe 12/2022

Pediatric Radiology 12/2022 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.