Erschienen in: BMC Musculoskeletal Disorders 1/2022

Open Access 01.12.2022 | Research

Sagittal intervertebral rotational motion: a deep learning-based measurement on flexion–neutral–extension cervical lateral radiographs

verfasst von: Yuting Yan, Xinsheng Zhang, Yu Meng, Qiang Shen, Linyang He, Guohua Cheng, Xiangyang Gong

Erschienen in: BMC Musculoskeletal Disorders | Ausgabe 1/2022

Abstract

Background

The analysis of sagittal intervertebral rotational motion (SIRM) can provide important information for the evaluation of cervical diseases. Deep learning has been widely used in spinal parameter measurements, however, there are few investigations on spinal motion analysis. The purpose of this study is to develop a deep learning-based model for fully automated measurement of SIRM based on flexion–neutral–extension cervical lateral radiographs and to evaluate its applicability for the flexion–extension (F/E), flexion–neutral (F/N), and neutral–extension (N/E) motion analysis.

Methods

A total of 2796 flexion, neutral, and extension cervical lateral radiographs from 932 patients were analyzed. Radiographs from 100 patients were randomly selected as the test set, and those from the remaining 832 patients were used for training and validation. Landmarks were annotated for measuring SIRM at five segments from C2/3 to C6/7 on F/E, F/N, and N/E motion. High-Resolution Net (HRNet) was used as the main structure to train the landmark detection network. Landmark performance was assessed according to the percentage of correct key points (PCK) and mean of the percentage of correct key points (MPCK). Measurement performance was evaluated by intra-class correlation coefficient (ICC), Pearson correlation coefficient, mean absolute error (MAE), root mean square error (RMSE), and Bland-Altman plots.

Results

At a 2-mm distance threshold, the PCK for the model ranged from 94 to 100%. Compared with the reference standards, the model showed high accuracy for SIRM measurements for all segments on F/E and F/N motion. On N/E motion, the model provided reliable measurements from C3/4 to C6/7, but not C2/3. Compared with the radiologists’ measurements, the model showed similar performance to the radiologists.

Conclusions

The developed model can automatically measure SIRM on flexion–neutral–extension cervical lateral radiographs and showed comparable performance with radiologists. It may provide rapid, accurate, and comprehensive information for cervical motion analysis.
Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1186/​s12891-022-05927-0.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
CNN
Convolutional neural network
CI
Confidence interval
F/E
Flexion–extension
F/N
Flexion–neutral
HRNet
High-Resolution Net
ICC
Intra-class correlation coefficient
r
Pearson correlation coefficient
RMSE
Root mean square error
SIRM
Sagittal intervertebral rotational motion
MAE
Mean absolute error
MPCK
Mean of the percentage of correct key points
N/E
Neutral–extension
PACS
Picture archiving and communication system
PCK
Percentage of correct key points

Background

Cervical kinematics evaluation plays an indispensable role in cervical-related diseases, including neck pain, whiplash-associated disorders, and cervical instability [13]. As the main part of cervical intervertebral motion parameters, sagittal intervertebral rotational motion (SIRM) provides precise biomechanical information and reveals early abnormal motion patterns [4, 5].
Originally, intervertebral motion parameters were measured manually with fine pencils on X-ray films [6]. Such handwork resulted in significant observer differences, which accounted for 38% or more of the value being measured [7]. Computer-assisted methods and various software have been developed for landmark location, parameter measurement, and data analysis to minimize subjective influence and accelerate processing speed [810]. However, manual annotation of the landmarks on vertebral bodies was unavoidable in these methods, which brought tedious and time-consuming work for operators.
Deep learning has been increasingly applied to the measurement of musculoskeletal radiographs [1113]. In the field of spinal disorders, a variety of models have demonstrated good to excellent performance in automatically measuring Cobb angle, spinopelvic parameters, and sagittal alignment, with the mean absolute error (MAE) ranging from 1° to 5° [1417]. Aside from static spinal parameter measurements, there were some studies focusing on the deep learning-based measurement for intervertebral motion. Jacobsen et al. [18] acquired cervical intervertebral angles on fluoroscopic images with a landmark detection algorism for cervical joint movement evaluation. Nguyen et al. [19] developed a deep learning system to measure lumbar intervertebral angles based on flexion and extension radiographs in order to determine the instability of the lumbar spondylolisthesis. The above studies have some limitations in using static parameters measured from a separate view to explore spinal motion function. Consequently, it is necessary to carry out a measurement derived from the combination of multiple views, which may provide more accurate and comprehensive information for spinal motion analysis.
The objective of the present study was to develop a fully automated deep learning model for the measurement of SIRM based on flexion–neutral–extension cervical lateral radiographs and to evaluate its applicability for the flexion–extension (F/E), flexion–neutral (F/N), and neutral–extension (N/E) motion analysis.

Methods

Dataset preparation

This study was approved by the Institutional Research Ethics Committee of Hospital (2022QT041). A total of 2247 cases for which flexion, neutral, and extension cervical lateral radiographs were taken in inpatient and outpatient settings between January 2019 and December 2020 were reviewed. The data of these patients were sequentially collected from the Picture Archiving and Communication System (PACS) of hospital. Adult patients (≥18 years) were included to ensure skeletal maturity in all cases in this study. The need for informed consent was waived due to the use of retrospective data. The exclusion criteria were as follows: (1) a history of cervical surgery; (2) partial or complete obscuration of the C7 vertebral body; (3) obscured landmarks due to severe osteophytes or fusion of adjacent vertebral bodies; and (4) poor radiograph quality and a wide range of aberrant motion out of the sagittal plane. From this review, a total of 2796 cervical lateral radiographs from 932 patients were collected. Radiographs from 100 cases were randomly assigned to the test set, and those from the remaining 832 cases were randomly divided in a 4:1 ratio to form the training and validation sets, respectively (Fig. 1).

Landmark annotations

The training and validation sets were manually annotated by one musculoskeletal radiologist (R1, 5 years of experience), and 100 cases of them were reannotated by R1 after a 6-week interval for the assessment of intra-observer reliability. The test set was independently annotated by R1, together with R2 (a radiologist with 3 years of experience) and R3 (a radiologist with 5 years of experience). All radiologists discussed and agreed on the annotation method before starting the work. A dedicated website was developed for manual annotation (http://​warehouse.​healthviewcn.​com/​).

Definitions of landmarks and parameter

A total of 22 landmarks were annotated on each radiograph on the flexion, neutral, and extension views. For the typical vertebrae from C3 to C7, the anterior–superior, posterior–superior, anterior–inferior, and posterior–inferior vertebral body corners were denoted by C-G1 to C-G4, respectively. For C2 vertebrae with a unique biological shape, only the anterior–inferior and posterior–inferior corners were denoted by B3 and B4, respectively. To reduce measurement error, all annotations of landmarks were made as close to the corticomedullary margin of the vertebral body as possible [7]. The method for measuring SIRM was based on the geometric midplanes method, for which excellent agreement and smaller errors have been demonstrated [20, 21]. The vertebral midplane was defined by a line through the two midpoints between the anterior and posterior corners. The specific name of each landmark and the method for measurement are illustrated in Fig. 2.

Measurement model development

The deep learning model for SIRM measurement included two parts: a landmark detection network used to identify landmarks on flexion, neutral, and extension cervical lateral radiographs and mathematical formulae to calculate SIRM values.
The main structure of the landmark detection network was High-Resolution Net (HRNet), a novel deep convolutional neural network with excellent performance in localizing anatomical landmarks on medical images [22]. HRNet maintains high-resolution representations through parallel branches from beginning to end and repeatedly fuses features from different scales to achieve solid semantics and accurate location. Due to the proximity of the landmarks on cervical radiographs, HRNet’s ability to preserve image details is crucial for model training. The landmark detection network consisted of four stages, beginning with a high-resolution branch as the first stage and then summing the high-to-low resolution branches in parallel to form the subsequent stages. At the end of each stage, information was repeatedly exchanged between parallel branches [23]. The final output was a 22-channel heatmap regressed from the high-resolution representation of the last stage. The coordinates with the maximum values in the heatmap were selected as the positions of predicted landmarks, which were mapped to the corresponding positions on the original image by applying affine transformation. To compare the ground truth and prediction heatmaps, the loss function was defined as the mean square error.
To build the landmark detection network, we trained our model on flexion, neutral, and extension cervical lateral radiographs. All images were preprocessed by resizing to a resolution of 512 × 512 pixels and augmented by random rotation, horizon flip, and random scale. The pixel spacing of each image was 0.143 mm. We used the stochastic gradient descent (SGD) optimizer with a base learning rate of 1e− 6, a momentum of 0.9, and a weight decay of 0.0005. The model was trained on PyTorch (Version 1.3) for 120 iterations with a batch size of 12 on NVIDIA TITAN Xp GPUs. The model with the least loss on the validation set was verified using the test set.
The coordinates of the predicted landmarks and the mathematical formulae for measurement were used for automatic calculations of SIRM by Python (version 3.7). An overview of model implementation is presented in Fig. 3.

Evaluation and statistical analysis

All analyses were performed using MedCalc software (version 20.023) and Microsoft Excel 2020 with statistical significance defined by values of P < 0.05.

Reliability of landmark annotation

For assessment of the intra- and inter- observer reliability of landmark annotation, the landmark-to-landmark distance was represented as percentages within 1–3-mm thresholds.

Landmark performance

The metrics of percentage of correct key points (PCK) and mean of the percentage of correct key points (MPCK) were used for evaluating the performance of landmark prediction. PCK was defined as the percentage of predicted landmarks that fell within the r-radius neighborhood of the reference standard landmark [24]. MPCK was defined as the mean PCK values of each vertebra from C2 to C7 (MC2–MC7) [22]. The reference standards were the averages of landmark coordinates annotated by the three radiologists [25].

Measurement performance

For further evaluation of measurement performance, our model was compared with the reference standards on the test set by calculating the intra-class correlation coefficient (ICC), the Pearson correlation coefficient (r), MAE, and the root mean square error (RMSE). The ICC was calculated for the evaluation of consistency, and an ICC ≥0.7 was considered adequate for reliability. An |r| ≥0.7 indicated a high correlation. MAE was defined as \(\frac{1}{m}{\sum}_{i=1}^m\left|{observed}_i-{predicted}_i\right|\), and RMSE was defined as \(\sqrt{\frac{1}{m}{\sum}_{i=1}^m{\left({observed}_i-{predicted}_i\right)}^2}\), where i was the number of images. Additionally, the mean difference and 95% limit of agreement (LoA) were determined on Bland–Altman plots. The reference standards were the averages of measurements from the three radiologists [25]. To compare the performance of the model with that of each radiologist, the paired differences between the value from each individual radiologist and the average from the other two radiologists were compared with the difference between the same average value and the model value using paired t-test for comparing MAE [12].

Results

General data distributions

A total of 932 cases with flexion, neutral, and extension cervical lateral radiographs were evaluated. There were 665, 167, and 100 patients in the training, validation, and test sets, respectively. There was no significant difference between the three datasets in gender composition and age (Table 1).
Table 1
Characteristics of patients in the training, validation, and test sets
Characteristic
Training set (n = 665)
Validation set (n = 167)
Test set (n = 100)
P
Male
283 (42.6)
59 (35.3)
42 (42)
0.234
Female
382 (57.4)
108 (64.7)
58 (58)
Age(y)a
49 (47,50)
49 (46,52)
49 (45,54)
0.646
 Male
47 (45,49)
49 (43,54)
47 (38.5,52.5)
0.836
 Female
50 (48,51)
49 (46,53)
52.5 (45,58)
0.326
Data are expressed as numbers of patients, with percentages in parentheses
P < 0.05 indicates significant difference between the training, validation, and test sets
aData are expressed as medians, with 95% confidence intervals (CI) in parentheses

Reliability of landmark annotation

The percentages of intra-observer landmark distances within the 2-mm threshold were 98–99% on the three views. The percentages of inter-observer landmark distances within the 2-mm threshold were 97–98% (R1 vs R2), 98% (R1 vs R3), and 97–98% (R2 vs R3) on the three views (Table 2).
Table 2
Inter-observer reliability of landmark annotation (%) on flexion, neutral, and extension views
Threshold
 
1 mm
  
2 mm
  
3 mm
 
F
N
E
F
N
E
F
N
E
R1 vs R2
84
85
84
97
98
97
99
99
99
R1 vs R3
85
86
85
98
98
98
99
99
99
R2 vs R3
79
81
81
98
98
97
99
99
99
F Flexion, N Neutral, E Extension

Landmark performance

The PCKs at the 2-mm distance threshold on the flexion, neutral, and extension views were 95–100%, 94–100%, and 94–100%, respectively (Additional file 1). The MPCKs for each vertebra from C2 to C7 at the 2-mm distance threshold on the flexion, neutral, and extension views were 98–99%, 98–99%, and 97–100%, respectively (Fig. 4). The average annotating time for one cervical lateral radiograph was 0.066 s, which was much faster than the annotating time of 2.1 min for a radiologist. Representative examples of landmark detection by the model are shown in Fig. 5.

Measurement performance

Measurement values from three radiologists and model estimates for SIRM were shown in Table 3. No significant differences were observed in the SIRM produced by the model estimates and the reference standards, except for the values for C2/3 (F/E motion), C3/4 (F/N motion), and C3/4 (N/E motion) (P < 0.05).
Table 3
Measurement values from three radiologists and model estimates for sagittal intervertebral rotational motion (SIRM) (°)
 
R1
R2
R3
Mean
Model
t
P
F/E motion
 C2/3
5.07 ± 3.36
6.19 ± 3.32
5.29 ± 3.33
5.52 ± 2.98
5.01 ± 3.29
−3.327
0.001
 C3/4
10.95 ± 4.81
10.46 ± 4.72
10.82 ± 4.61
10.74 ± 4.49
10.78 ± 4.77
0.218
0.827
 C4/5
12.40 ± 5.36
12.56 ± 5.63
12.66 ± 5.35
12.54 ± 5.23
12.68 ± 5.66
0.683
0.496
 C5/6
11.46 ± 6.17
11.39 ± 5.93
11.44 ± 6.10
11.43 ± 5.90
11.21 ± 6.23
−1.028
0.307
 C6/7
9.84 ± 5.18
9.73 ± 5.17
9.85 ± 5.05
9.81 ± 4.95
9.59 ± 5.21
−1.311
0.193
F/N motion
 C2/3
3.71 ± 2.71
4.02 ± 2.64
3.87 ± 2.60
3.87 ± 2.19
3.94 ± 2.64
−0.392
0.696
 C3/4
6.13 ± 3.95
6.36 ± 3.39
6.22 ± 3.89
6.24 ± 3.49
6.79 ± 3.73
−3.118
0.002
 C4/5
6.96 ± 4.08
6.98 ± 4.09
7.20 ± 3.71
7.05 ± 3.69
7.22 ± 4.29
0.748
0.456
 C5/6
7.55 ± 4.28
7.49 ± 4.25
7.47 ± 4.38
7.50 ± 4.08
7.32 ± 4.51
−0.881
0.381
 C6/7
7.86 ± 4.39
7.72 ± 4.15
7.80 ± 4.22
7.79 ± 4.01
7.65 ± 3.93
−0.952
0.344
N/E motion
 C2/3
2.84 ± 2.29
3.00 ± 2.37
2.77 ± 2.07
2.87 ± 1.74
2.69 ± 1.88
−1.095
0.276
 C3/4
5.06 ± 3.80
4.38 ± 3.63
4.76 ± 3.69
4.73 ± 3.47
4.27 ± 3.39
−2.789
0.006
 C4/5
5.91 ± 4.11
5.81 ± 4.05
5.57 ± 3.95
5.76 ± 3.84
5.64 ± 4.04
−0.585
0.560
 C5/6
4.57 ± 3.51
4.25 ± 2.94
4.47 ± 3.25
4.43 ± 2.93
4.65 ± 3.38
1.127
0.262
 C6/7
2.71 ± 2.09
2.62 ± 2.21
2.76 ± 2.36
2.70 ± 1.90
2.72 ± 2.41
0.123
0.902
Data are expressed as the means ± SDs
F/E Flexion–extension, F/N Flexion–neutral, N/E Neutral–extension
P < 0.05 (paired t-test) indicates significant difference between the model and reference standard
With regard to consistency and accuracy, the model yielded accurate measurements of all segments on F/E motion (ICC = 0.86–0.95, r = 0.88–0.95, RMSE = 1.64–2.11, MAE = 1.22–1.59) and F/N motion (ICC = 0.73–0.93, r = 0.74–0.93, RMSE = 1.50–2.27, MAE = 1.19–1.69). On N/E motion, the model provided reliable measurements from C3/4 to C6/7 (ICC = 0.73–0.88, r = 0.75–0.88, RMSE = 1.59–2.05, MAE = 1.28–1.49), but not C2/3 (ICC = 0.60, r = 0.61, RMSE = 1.61, MAE = 1.21; Table 4). The Bland–Altman plots with 95% LoAs and scatter diagrams of correlation analysis are shown in Fig. 6 (F/E motion) and Additional files 2 and 3 (F/N and N/E motion).
Table 4
Comparison of model estimates and reference standards for sagittal intervertebral rotational motion (°)
 
ICC (95% CI)
r (95% CI)
Mean Difference
SD
RMSE (95% CI)
MAE (95% CI)
F/E motion
 C2/3
0.86 (0.79, 0.91)
0.88 (0.83,0.92)
−0.52
1.57
1.64 (1.44,1.90)
1.23 (1.01,1.45)
 C3/4
0.93 (0.90,0.95)
0.93 (0.90, 0.96)
0.04
1.70
1.70 (1.49,1.97)
1.22 (0.99,1.46)
 C4/5
0.93 (0.90,0.95)
0.93 (0.90, 0.96)
0.14
2.02
2.01 (1.77,2.33)
1.57 (1.32,1.82)
 C5/6
0.94 (0.91, 0.96)
0.94 (0.91, 0.96)
−0.22
2.10
2.11 (1.85,2.45)
1.59 (1.32,1.87)
 C6/7
0.95 (0.92, 0.96)
0.95 (0.92, 0.96)
−0.22
1.68
1.69 (1.48,1.96)
1.29 (1.08,1.51)
F/N motion
 C2/3
0.73 (0.62, 0.81)
0.74 (0.64, 0.82)
0.07
1.79
1.78 (1.56,2.07)
1.40 (1.18,1.62)
 C3/4
0.87 (0.81, 0.92)
0.88 (0.83, 0.92)
0.55
1.75
1.83 (1.61,2.12)
1.37 (1.13,1.61)
 C4/5
0.84 (0.77, 0.89)
0.85 (0.78, 0.90)
0.17
2.27
2.27 (1.99,2.63)
1.69 (1.39,1.99)
 C5/6
0.87 (0.84, 0.92)
0.89 (0.84, 0.93)
−0.18
2.05
2.05 (1.80,2.38)
1.66 (1.42,1.90)
 C6/7
0.93 (0.90, 0.95)
0.93 (0.90, 0.95)
−0.14
1.50
1.50 (1.32,1.74)
1.19 (1.00,1.37)
N/E motion
 C2/3
0.60 (0.46, 0.71)
0.61 (0.46, 0.72)
−0.18
1.61
1.61 (1.41,1.87)
1.21 (1.00,1.43)
 C3/4
0.88 (0.82, 0.92)
0.88 (0.83, 0.92)
−0.46
1.66
1.71 (1.50,1.98)
1.34 (1.13,1.55)
 C4/5
0.87 (0.81, 0.91)
0.87 (0.81, 0.91)
−0.12
2.05
2.05 (1.80,2.38)
1.49 (1.21,1.77)
 C5/6
0.80 (0.72, 0.86)
0.81 (0.73, 0.87)
0.22
1.98
1.99 (1.75,2.31)
1.43 (1.16,1.71)
 C6/7
0.73 (0.62, 0.81)
0.75 (0.65, 0.82)
0.02
1.60
1.59 (1.40,1.85)
1.28 (1.10,1.47)
ICC Intra-class correlation coefficient, r Pearson correlation coefficient, SD Standard deviation, RMSE Root mean square error, MAE Mean absolute error, CI Confidence interval, F/E Flexion–extension, F/N Flexion–neutral, N/E Neutral–extension
On F/E motion, the MAEs of the model were significantly lower than those of R1 and R2 at C2/3 (P < 0.05) and those of R2 at C3/4 and C6/7 (P < 0.05). On F/N motion, the MAEs of the model were significantly lower than that of R3 at C2/3 (P < 0.05) and those of R1, R2, and R3 at C6/7 (P < 0.05). On N/E motion, the MAE of the model was significantly lower than that of R1 at C2/3 (P < 0.05; Table 5).
Table 5
Comparisons of each radiologist and the model for sagittal intervertebral rotational motion
MAE
Mean of R2 and R3
Mean of R1 and R3
Mean of R1 and R2
F/E
F/N
N/E
F/E
F/N
N/E
F/E
F/N
N/E
C2/3
 Radiologist*
1.92
1.67
1.70
1.95
1.71
1.63
1.78
1.86
1.59
 Model
1.33
1.55
1.26
1.30
1.56
1.33
1.54
1.49
1.37
 P
0.00
0.48
0.01
0.00
0.36
0.06
0.09
0.04
0.18
C3/4
 Radiologist*
1.68
1.64
1.58
1.79
1.65
1.66
1.62
1.69
1.25
 Model
1.34
1.41
1.38
1.37
1.47
1.46
1.44
1.51
1.45
 P
0.08
0.19
0.23
0.01
0.34
0.21
0.24
0.29
0.16
C4/5
 Radiologist*
1.81
1.80
1.51
1.95
1.71
1.59
1.54
1.69
1.42
 Model
1.71
1.68
1.51
1.64
1.77
1.60
1.67
1.89
1.65
 P
0.58
0.54
0.99
0.13
0.77
0.96
0.43
0.32
0.19
C5/6
 Radiologist*
1.58
1.58
1.54
1.73
1.62
1.48
1.66
1.58
1.53
 Model
1.74
1.80
1.44
1.75
1.72
1.54
1.69
1.70
1.57
 P
0.41
0.25
0.60
0.87
0.56
0.75
0.86
0.51
0.80
C6/7
 Radiologist*
1.54
1.62
1.30
1.73
1.62
1.37
1.46
1.70
1.42
 Model
1.42
1.27
1.41
1.40
1.30
1.35
1.40
1.34
1.28
 P
0.51
0.02
0.45
0.04
0.03
0.88
0.72
0.02
0.33
MAE mean absolute error, F/E flexion–extension, F/N Flexion–neutral, N/E Neutral–extension
P < 0.05 indicates significant inter-observer difference
Radiologist* indicates the other radiologist

Discussion

In the present study, we developed a deep learning-based model to detect landmarks necessary for measuring cervical SIRM. On the test set, we found that our landmark detection network achieved the PCKs ranging from 94 to 100% at the 2-mm distance threshold. Based on this network, the developed model for automatic SIRM measurements was comparable in performance to radiologists’ calculations.
Manual annotation is the main source of observer differences in spinal measurement. The reliability depends on the experience and judgment of radiologists. A landmark-to-landmark distance of 2.98 mm for inter-observer observations was reported to be acceptable for clinical analysis [26]. In the present study, the PCKs of our developed model at a 2-mm distance threshold ranged from 97 to 98% on the three views, which was similar to the percentage of inter-observer landmark distance from three radiologists. As a result, both the model and the radiologists were able to provide reliable landmark annotations. On all three views, the PCKs of C2 within a 2-mm distance threshold were relatively higher than other segments, which might be contributed to fewer degenerations occurring at C2 [27].
Measurement performance is mostly evaluated by calculating various measurement errors. In the applications of the spine, the MAEs could be less than 2° or close to 10° [19, 28]. This indicates the performance of models varying greatly in different spinal landmarks and parameters. For SIRM, the interobserver variability of manual measurement could be up to 5.2°, which might not provide accurate evaluations for instability, abnormality, and preoperative motion function [29]. A study conducted by Frobin et al. reported that the error (standard deviation, SD) of approximately 2° was satisfactory for clinical cervical motion analysis [21]. In our test set, the model demonstrated excellent measurement performance and reliable clinical application with MAEs and SDs ranging from 1.19° to 1.69° and 1.50° to 2.27°, respectively. In the comparison of the model and radiologists, the MAEs of our model were equal to or significantly lower than those of the radiologists, indicating that our model showed similar or smaller errors compared to the radiologists. The model also achieved satisfactory agreement from C3/4 to C6/7, but the ICCs and rs at C2/3 were not sufficient to guarantee reliable consistency, especially on N/E motion (ICC = 0.60, r = 0.61). This might be due to the extremely small range of motion at C2/3, resulting in even slight differences (MAE = 1.21–1.40) having significant impacts [20].
Flexion, neutral, and extension cervical lateral radiographs are essential tools in the assessment of cervical SIRM and there will be great translational potentials in future clinical practice. The model will automatically generate parameter measurement reports for doctors and patients to facilitate clinical diagnosis and treatment guidance. With the expansion of the database, the obtained measurement results will be used to build population-based models to provide personalized reference intervals for cervical SIRM of different genders and ages in asymptomatic and symptomatic individuals.
The present study does have several limitations. First, for the correctness and integrity of landmark annotation, we excluded a large number of patients based on postoperative status and obscuration of the C7 vertebral bodies. Second, because of inherent variations in manual annotation and the lack of a gold standard, some difficulties remain in accurately comparing performance between radiologists and the model. Third, the category and size of the training dataset are insufficient to represent the complex clinical environment. In future research, we will include more kinds of cases, with particular inclusion of patients with implanted surgical devices. For unsatisfactory landmark prediction due to anatomical variation or overlap, radiologists could slightly adjust the landmarks, and the feedback could be used to enhance model performance in efforts to further improve our model.

Conclusions

A deep learning-based model was developed for automated SIRM measurement on flexion–neutral–extension cervical lateral radiographs and showed comparable performance with radiologists. It may provide rapid, accurate, and comprehensive information for cervical motion analysis.

Acknowledgements

Not applicable.

Declarations

This study was approved by the Ethics Committee of Zhejiang Provincial People’s Hospital, China (No. 2022QT041). A certificate of approval has been provided. All procedures were performed in accordance with the Declaration of Helsinki and relevant guidelines. The requirement of informed consent was exempted due to the retrospective nature of the study by the Ethics Committee of Zhejiang Provincial People’s Hospital.
Not applicable.

Competing interests

The authors declare that they have no conflicts of interest.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Qu N, Lindstrøm R, Hirata RP, Graven-Nielsen T. Origin of neck pain and direction of movement influence dynamic cervical joint motion and pressure pain sensitivity. Clin Biomech (Bristol, Avon). 2019;61:120–8.CrossRef Qu N, Lindstrøm R, Hirata RP, Graven-Nielsen T. Origin of neck pain and direction of movement influence dynamic cervical joint motion and pressure pain sensitivity. Clin Biomech (Bristol, Avon). 2019;61:120–8.CrossRef
2.
Zurück zum Zitat Stenneberg MS, Rood M, de Bie R, Schmitt MA, Cattrysse E, Scholten-Peeters GG. To what degree does active cervical range of motion differ between patients with neck pain, patients with whiplash, and those without neck pain? A systematic review and Meta-analysis. Arch Phys Med Rehabil. 2017;98(7):1407–34.CrossRefPubMed Stenneberg MS, Rood M, de Bie R, Schmitt MA, Cattrysse E, Scholten-Peeters GG. To what degree does active cervical range of motion differ between patients with neck pain, patients with whiplash, and those without neck pain? A systematic review and Meta-analysis. Arch Phys Med Rehabil. 2017;98(7):1407–34.CrossRefPubMed
3.
Zurück zum Zitat Alvarez AP, Anderson A, Farhan SD, Lu Y, Lee YP, Oh M, et al. The utility of flexion-extension radiographs in degenerative cervical spondylolisthesis. Clin Spine Surg. 2022;35(7):319–22.CrossRefPubMedPubMedCentral Alvarez AP, Anderson A, Farhan SD, Lu Y, Lee YP, Oh M, et al. The utility of flexion-extension radiographs in degenerative cervical spondylolisthesis. Clin Spine Surg. 2022;35(7):319–22.CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Wang X, Lindstroem R, Plocharski M, Østergaaard LR, Graven-Nielsen T. Cervical flexion and extension includes anti-directional cervical joint motion in healthy adults. Spine J. 2018;18(1):147–54.CrossRefPubMed Wang X, Lindstroem R, Plocharski M, Østergaaard LR, Graven-Nielsen T. Cervical flexion and extension includes anti-directional cervical joint motion in healthy adults. Spine J. 2018;18(1):147–54.CrossRefPubMed
5.
Zurück zum Zitat Zhou C, Li G, Wang C, Wang H, Yu Y, Tsai TY, et al. In vivo intervertebral kinematics and disc deformations of the human cervical spine during walking. Med Eng Phys. 2021;87:63–72.CrossRefPubMed Zhou C, Li G, Wang C, Wang H, Yu Y, Tsai TY, et al. In vivo intervertebral kinematics and disc deformations of the human cervical spine during walking. Med Eng Phys. 2021;87:63–72.CrossRefPubMed
6.
Zurück zum Zitat Amevo B, Worth D, Bogduk N. Instantaneous axes of rotation of the typical cervical motion segments: II. optimization of technical errors. Clin Biomech (Bristol, Avon). 1991;6(1):38–46.CrossRef Amevo B, Worth D, Bogduk N. Instantaneous axes of rotation of the typical cervical motion segments: II. optimization of technical errors. Clin Biomech (Bristol, Avon). 1991;6(1):38–46.CrossRef
7.
Zurück zum Zitat Amevo B, Macintosh JE, Worth D, Bogduk N. Instantaneous axes of rotation of the typical cervical motion segments: I. an empirical study of technical errors. Clin Biomech (Bristol, Avon). 1991;6(1):31–7.CrossRef Amevo B, Macintosh JE, Worth D, Bogduk N. Instantaneous axes of rotation of the typical cervical motion segments: I. an empirical study of technical errors. Clin Biomech (Bristol, Avon). 1991;6(1):31–7.CrossRef
8.
Zurück zum Zitat Meisel HJ, Jurák L, Antinheimo J, Arregui R, Bruchmann B, Čabraja M, et al. Four-year results of a prospective single-arm study on 200 semi-constrained total cervical disc prostheses: clinical and radiographic outcome. J Neurosurg Spine. 2016;25(5):556–65.CrossRefPubMed Meisel HJ, Jurák L, Antinheimo J, Arregui R, Bruchmann B, Čabraja M, et al. Four-year results of a prospective single-arm study on 200 semi-constrained total cervical disc prostheses: clinical and radiographic outcome. J Neurosurg Spine. 2016;25(5):556–65.CrossRefPubMed
9.
Zurück zum Zitat Mehren C, Heider F, Siepe CJ, Zillner B, Kothe R, Korge A, et al. Clinical and radiological outcome at 10 years of follow-up after total cervical disc replacement. Eur Spine J. 2017;26(9):2441–9.CrossRefPubMed Mehren C, Heider F, Siepe CJ, Zillner B, Kothe R, Korge A, et al. Clinical and radiological outcome at 10 years of follow-up after total cervical disc replacement. Eur Spine J. 2017;26(9):2441–9.CrossRefPubMed
10.
Zurück zum Zitat Plocharski M, Lindstroem R, Lindstroem CF, Østergaard LR. Motion analysis of the cervical spine during extension and flexion: reliability of the vertebral marking procedure. Med Eng Phys. 2018;61:81–6.CrossRefPubMed Plocharski M, Lindstroem R, Lindstroem CF, Østergaard LR. Motion analysis of the cervical spine during extension and flexion: reliability of the vertebral marking procedure. Med Eng Phys. 2018;61:81–6.CrossRefPubMed
11.
Zurück zum Zitat Ye Q, Shen Q, Yang W, Huang S, Jiang Z, He L, et al. Development of automatic measurement for patellar height based on deep learning and knee radiographs. Eur Radiol. 2020;30(9):4974–84.CrossRefPubMed Ye Q, Shen Q, Yang W, Huang S, Jiang Z, He L, et al. Development of automatic measurement for patellar height based on deep learning and knee radiographs. Eur Radiol. 2020;30(9):4974–84.CrossRefPubMed
12.
Zurück zum Zitat Yang W, Ye Q, Ming S, Hu X, Jiang Z, Shen Q, et al. Feasibility of automatic measurements of hip joints based on pelvic radiography and a deep learning algorithm. Eur J Radiol. 2020;132:109303.CrossRefPubMed Yang W, Ye Q, Ming S, Hu X, Jiang Z, Shen Q, et al. Feasibility of automatic measurements of hip joints based on pelvic radiography and a deep learning algorithm. Eur J Radiol. 2020;132:109303.CrossRefPubMed
13.
Zurück zum Zitat Zheng Q, Shellikeri S, Huang H, Hwang M, Sze RW. Deep learning measurement of leg length discrepancy in children based on radiographs. Radiology. 2020;296(1):152–8.CrossRefPubMed Zheng Q, Shellikeri S, Huang H, Hwang M, Sze RW. Deep learning measurement of leg length discrepancy in children based on radiographs. Radiology. 2020;296(1):152–8.CrossRefPubMed
14.
Zurück zum Zitat Bernstein P, Metzler J, Weinzierl M, Seifert C, Kisel W, Wacker M. Radiographic scoliosis angle estimation: spline-based measurement reveals superior reliability compared to traditional COBB method. Eur Spine J. 2021;30(3):676–85.CrossRefPubMed Bernstein P, Metzler J, Weinzierl M, Seifert C, Kisel W, Wacker M. Radiographic scoliosis angle estimation: spline-based measurement reveals superior reliability compared to traditional COBB method. Eur Spine J. 2021;30(3):676–85.CrossRefPubMed
15.
Zurück zum Zitat Schwartz JT, Cho BH, Tang P, Schefflein J, Arvind V, Kim JS, et al. Deep learning automates measurement of spinopelvic parameters on lateral lumbar radiographs. Spine (Phila Pa 1976). 2021;46(12):E671–e678. Schwartz JT, Cho BH, Tang P, Schefflein J, Arvind V, Kim JS, et al. Deep learning automates measurement of spinopelvic parameters on lateral lumbar radiographs. Spine (Phila Pa 1976). 2021;46(12):E671–e678.
16.
Zurück zum Zitat Yeh YC, Weng CH, Huang YJ, Fu CJ, Tsai TT, Yeh CY. Deep learning approach for automatic landmark detection and alignment analysis in whole-spine lateral radiographs. Sci Rep. 2021;11(1):7618.CrossRefPubMedPubMedCentral Yeh YC, Weng CH, Huang YJ, Fu CJ, Tsai TT, Yeh CY. Deep learning approach for automatic landmark detection and alignment analysis in whole-spine lateral radiographs. Sci Rep. 2021;11(1):7618.CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Vrtovec T, Ibragimov B. Spinopelvic measurements of sagittal balance with deep learning: systematic review and critical evaluation. Eur Spine J. 2022;31(8):2031–45.CrossRefPubMed Vrtovec T, Ibragimov B. Spinopelvic measurements of sagittal balance with deep learning: systematic review and critical evaluation. Eur Spine J. 2022;31(8):2031–45.CrossRefPubMed
18.
Zurück zum Zitat Jakobsen IMG, Plocharski M. Automatic detection of cervical vertebral landmarks for fluoroscopic joint motion analysis. In: Scandinavian conference on image analysis: 2019. Cham: Springer International Publishing; 2019. p. 209–20. Jakobsen IMG, Plocharski M. Automatic detection of cervical vertebral landmarks for fluoroscopic joint motion analysis. In: Scandinavian conference on image analysis: 2019. Cham: Springer International Publishing; 2019. p. 209–20.
19.
Zurück zum Zitat Nguyen TP, Chae D-S, Park S-J, Kang K-Y, Yoon J. Deep learning system for Meyerding classification and segmental motion measurement in diagnosis of lumbar spondylolisthesis. Biomed Signal Process Control. 2021;65:102371.CrossRef Nguyen TP, Chae D-S, Park S-J, Kang K-Y, Yoon J. Deep learning system for Meyerding classification and segmental motion measurement in diagnosis of lumbar spondylolisthesis. Biomed Signal Process Control. 2021;65:102371.CrossRef
20.
Zurück zum Zitat Wu SK, Jou JY, Lee HM, Chen HY, Su FC, Kuo LC. The reproducibility comparison of two intervertebral translation measurements in cervical flexion-extension. Spine J. 2015;15(5):1083–91.CrossRefPubMed Wu SK, Jou JY, Lee HM, Chen HY, Su FC, Kuo LC. The reproducibility comparison of two intervertebral translation measurements in cervical flexion-extension. Spine J. 2015;15(5):1083–91.CrossRefPubMed
21.
Zurück zum Zitat Frobin W, Leivseth G, Biggemann M, Brinckmann P. Sagittal plane segmental motion of the cervical spine. a new precision measurement protocol and normal motion data of healthy adults. Clin Biomech (Bristol, Avon). 2002;17(1):21–31.CrossRef Frobin W, Leivseth G, Biggemann M, Brinckmann P. Sagittal plane segmental motion of the cervical spine. a new precision measurement protocol and normal motion data of healthy adults. Clin Biomech (Bristol, Avon). 2002;17(1):21–31.CrossRef
22.
Zurück zum Zitat Zhang M, Zhang K, Yu D, Xie Q, Liu B, Chen D, et al. Computerized assisted evaluation system for canine cardiomegaly via key points detection with deep learning. Prev Vet Med. 2021;193:105399.CrossRefPubMed Zhang M, Zhang K, Yu D, Xie Q, Liu B, Chen D, et al. Computerized assisted evaluation system for canine cardiomegaly via key points detection with deep learning. Prev Vet Med. 2021;193:105399.CrossRefPubMed
23.
Zurück zum Zitat Sun K, Xiao B, Liu D, Wang J. Deep high-resolution representation learning for human pose estimation. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, vol. 2019; 2019. p. 5693–703. Sun K, Xiao B, Liu D, Wang J. Deep high-resolution representation learning for human pose estimation. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, vol. 2019; 2019. p. 5693–703.
24.
Zurück zum Zitat Payer C, Štern D, Bischof H, Urschler M. Integrating spatial configuration into heatmap regression based CNNs for landmark localization. Med Image Anal. 2019;54:207–19.CrossRefPubMed Payer C, Štern D, Bischof H, Urschler M. Integrating spatial configuration into heatmap regression based CNNs for landmark localization. Med Image Anal. 2019;54:207–19.CrossRefPubMed
25.
Zurück zum Zitat Larson DB, Chen MC, Lungren MP, Halabi SS, Stence NV, Langlotz CP. Performance of a deep-learning neural network model in assessing skeletal maturity on pediatric hand radiographs. Radiology. 2018;287(1):313–22.CrossRefPubMed Larson DB, Chen MC, Lungren MP, Halabi SS, Stence NV, Langlotz CP. Performance of a deep-learning neural network model in assessing skeletal maturity on pediatric hand radiographs. Radiology. 2018;287(1):313–22.CrossRefPubMed
26.
Zurück zum Zitat Chen HC, Lin CJ, Wu CH, Wang CK, Sun YN. Automatic Insall-Salvati ratio measurement on lateral knee x-ray images using model-guided landmark localization. Phys Med Biol. 2010;55(22):6785–800.CrossRefPubMed Chen HC, Lin CJ, Wu CH, Wang CK, Sun YN. Automatic Insall-Salvati ratio measurement on lateral knee x-ray images using model-guided landmark localization. Phys Med Biol. 2010;55(22):6785–800.CrossRefPubMed
27.
Zurück zum Zitat Tao Y, Galbusera F, Niemeyer F, Samartzis D, Vogele D, Wilke H-J. Radiographic cervical spine degenerative findings: a study on a large population from age 18 to 97 years. Eur Spine J. 2021;30(2):431–43.CrossRefPubMed Tao Y, Galbusera F, Niemeyer F, Samartzis D, Vogele D, Wilke H-J. Radiographic cervical spine degenerative findings: a study on a large population from age 18 to 97 years. Eur Spine J. 2021;30(2):431–43.CrossRefPubMed
28.
Zurück zum Zitat Vrtovec T, Ibragimov B. Spinopelvic measurements of sagittal balance with deep learning: systematic review and critical evaluation. Eur Spine J. 2022;31(8):2031–45.CrossRefPubMed Vrtovec T, Ibragimov B. Spinopelvic measurements of sagittal balance with deep learning: systematic review and critical evaluation. Eur Spine J. 2022;31(8):2031–45.CrossRefPubMed
29.
Zurück zum Zitat Pearson AM, Spratt KF, Genuario J, McGough W, Kosman K, Lurie J, et al. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability? Spine (Phila Pa 1976). 2011;36(7):572–80.CrossRef Pearson AM, Spratt KF, Genuario J, McGough W, Kosman K, Lurie J, et al. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability? Spine (Phila Pa 1976). 2011;36(7):572–80.CrossRef
Metadaten
Titel
Sagittal intervertebral rotational motion: a deep learning-based measurement on flexion–neutral–extension cervical lateral radiographs
verfasst von
Yuting Yan
Xinsheng Zhang
Yu Meng
Qiang Shen
Linyang He
Guohua Cheng
Xiangyang Gong
Publikationsdatum
01.12.2022
Verlag
BioMed Central
Erschienen in
BMC Musculoskeletal Disorders / Ausgabe 1/2022
Elektronische ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-022-05927-0

Weitere Artikel der Ausgabe 1/2022

BMC Musculoskeletal Disorders 1/2022 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.