Skip to main content
Erschienen in: BMC Oral Health 1/2023

Open Access 01.12.2023 | Research

Accuracy of fit for cobaltchromium bar over two implants fabricated with different manufacturing techniques: an in-vitro study

verfasst von: Hossam I. Nassar, Ayman Fateen

Erschienen in: BMC Oral Health | Ausgabe 1/2023

Abstract

Objective

The purpose of the invitro research was to compare the fit of Cobalt Chromium customized bar fabricated with different manufacturing processes cast metal bar, milled bar and 3D printed bar using scanning electron microscope.

Materials and methods

Clear epoxy resin molds were prepared. In each mold two parallel implants with a 14 mm distance from each other were embedded. Thirty Co-Cr custom bars were constructed and were divided equally into three groups: Group (I) (Co-Cr conv), group (II) milled bar (Co-Cr milled), and group (III) printed bar (Co-Cr print). The marginal fit at implant-abutment interface was scanned using scanning electron microscope (SEM).

Results

There was a significant difference between the three studied groups regarding marginal misfit the between implant and fabricated bars with p-value < 0.001. The highest value of micro-gap distance was found in Co-Cr conventional group (7.95 ± 2.21 μm) followed by Co-Cr 3D printed group (4.98 ± 1.73) and the lower value were found in Co-Cr milled (3.22 ± 0.75).

Conclusion

The marginal fit of milled, 3D printed and conventional cast for Co-Cr alloy were within the clinically acceptable range of misfit. CAD/CAM milled Co-Cr bar revealed a superior internal fit at the implant-abutment interface. This was followed by selective laser melting (SLM) 3D printed bar and the least fit was shown for customized bar with the conventional lost wax technique.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

One of the most important factors for the success of treatment planning in screw retained implant prosthesis is directly related to the passivity of the restoration. The passive fit of restoration after the final tightening of all screws can be achieved when the opposing surfaces of the implant and the prosthetic component are in maximal three-dimensional resemblance and contact without strain in any of the components [1, 2].
The fit and the micro gap between the implant and customized bars can lead to both mechanical and biological complications. The colonization of microorganisms in the inner part of the implant can eventually cause inflammation of peri-implant tissues and bone strain with consequent pain. This situation may lead to marginal bone loss around the dental implant and eventually can lead to failure of the whole osseointegration [3, 4].
The increase in the number of implants placed, their angulation, and the distance between them can increase the risk of misfit of implant components. Besides, the conventional workflow for final restoration starting from the impression procedure involving impression analogues, impression materials, and stone casts can even potentially grow the problem [5].
Implant abutments for different prosthetic restorations are either prefabricated (stock) which is commercially available or customized [6]. The customization of bars and abutments can be produced by conventional cast procedure such as UCLA-type abutment. Castable UCLA abutments are usually combined with a prefabricated metallic base of cobalt chromium that fits exactly in the internal connection of the implant to prevent distortion and misfit that can arise in the cast procedure [7].
In an attempt to control internal misfit between the implant and custom-made abutments and bars from a fully digital workflow, the use of hybrid abutments has evolved. This concept is known as Ti-Base abutment which consists of an industrially prefabricated abutment system that can accept custom milled monolithic or bi-layered superstructures and different metallic bar design restorations [8, 9].
The abutment–implant interface is considered one of the areas where occlusal force is concentrated and transferred to the implant. Therefore, long-term firmness is crucial for reducing clinical complications of dental implant. Lack of precision fit at the implant-abutment interface leads to prosthetic complications affecting the meso-structure or the superstructure. The complications include increase of occlusal overload, loss of passivity, micro-Pump effect, peri-implantitis, frequent screw loosening, abutment screw fractures, wear and deformation of the implant index, wear of the abutment connection and loss of implant osseointegration [1013]. Chrome-Cobalt alloy (Cr-Co) was largely employed in several aspects in dentistry due to its high strength, low cost, corrosion resistance when compared to other alloys. Unfortunately, scientific research concerning the use of Co-Cr alloy for implant restorations is inadequate [14].
Various techniques were generally discussed to evaluate implant-abutment fit in literature. Clinically, it can be evaluated by visual inspection, radiographs, and alternative finger pressure for tactile sensation of the joint. Sheffield test and screw resistance test were claimed to be highly precise for any lack of passivity and presence of implant abutment misfit. Microscopic methods of evaluation have also been employed including the use of a light microscope and scanning electron microscope (SEM) to measure the implant abutment micro gap fit. The micro gap fit can also be assessed through finite element modelling, strain measurement, photoelastic stress analysis, or by digital scan of surface superimposition for the final framework and the master cast [15, 16].
Today, computer-aided designing and computer-aided manufacturing (CAD/CAM) enabled the wide use of custom-made abutments and bars with the following advantages: reduction of fabrication time, precise level of customization and wide selection of different manufacturing materials. CAD/CAM technology has been recommended as a development over conventional cast manufacturing because it allows the high accuracy machining of prefabricated blocks of different materials including composite and acrylic resins, ceramics, and different metal alloys as titanium and cobalt chromium [17].
Research work and industrial procedures concerns determining whether the additive manufacturing technologies can substitute or introduce a new manufacturing system [18, 19]. Those additive manufacturing technologies fabricate customized subperiosteal, endosseous titanium implants [2024], meshes for different bone grafting procedures, (2526) and Co-Cr and Titanium frameworks for either fixed or removable implant-supported prostheses [2729].
The purpose of the present invitro study was to compare the marginal fit of Co-Cr customized bar fabricated with different manufacturing techniques. The null hypothesis was that there is a difference in the marginal fit of Co-Cr customized bars fabricated with digital and conventional processes.

Materials and methods

Specimen preparation

Thirty clear epoxy resin molds (Swiss Chem: construction chemicals, Egypt) were prepared and used in the present study in the following dimensions: 8 mm in height, 18 mm in width, and 8 mm in thickness. In each mold two bone level dental implants (Neobiotic, IS-II active, South Korea) with internal morse connection in its upper part and hexagon shape in its lower part as anti-rotation feature. The implants were 4 mm in diameter and 10 mm in length and they were embedded leaving 3 mm of implant surface exposed. The implants were placed parallel to each other by the aid of dental surveyor (Ney Surveyor, Dentsply, USA) with a 14 mm distance from each other. Two scan abutments (Neobiotic, IS scan body, D4, SCRP, South Korea) were attached to the implants and scanned using a desktop scanner (D850, 3Shape, Copenhagen, Denmark). The STL files were imported, and a bar over the two implants was designed using 3Shape software program (3Shape dental designer, 3Shape A/S, Copenhagen, Denmark). A total of thirty bars were manufactured by different manufacturing techniques as follows.
Twenty Co-Cr bars were constructed by milling process utilizing the computer milling machine (CAM) (Ceramill, Amann Girrbach, Austria) where the cutting tools remove the excess material gradually and shape the bar according to the planned design (CAD). The twenty bars were sub divided equally into: Group (I) (Co-Cr conv) were polymethyl methacrylate (PMMA) (Yourcera Biotechnology Co.,Ltd, China) milled bars acquired from the previous scanned and designed data and later the metallic bars were obtained by conventional lost wax technique using Co-Cr alloy (Scheftner Dental Alloy, GmbH, Germany). In Group (II) (Co-Cr milled) were Co-Cr milled bars directly milled according to the previous design.
In Group (III) (Co-Cr print) ten bars were obtained by selective laser melting (SLM) 3D printed process. The 3D printed bars (SLM) were fabricated using the laser beam (HBD 100D, Guangdong Hanbang 3D Tech Co. Ltd, China), in which the raw powdered material of Co-Cr was placed in a tray (Scheftner Dental Alloy, GmbH, Germany). Later, laser beam was spotted over the tray to rise the temperature of the powder and bind the particles together layer by layer to the required shape. Laser power was set to 200 W, the speed of laser scan to 1200 mm/s, the hatch distance to 0.03 mm, and finally layer thickness of 30 μm was applied. Following the SLM processes, the specimens were exposed to heat treatment in a furnace with high-purity argon. The heat treatment in the furnace went from room temperature to 1000 °C in one hour and kept at that temperature for an additional one hour. Then the specimens were slowly cooled to room temperature in the furnace.
The different manufactured bars were then fitted into the implants engaging their internal connection and the abutment screw was tightened using a dynamic torque wrench of 30 N following the manufacturer’s specifications (Fig. 1). All implants were subjected to vertical sectioning using water jet-powered sectioning equipment (Isomet, Buehler, Germany), followed by copious rinsing with distilled water and ethyl alcohol to remove any clogged debris that would affect accurate visualization of the implant–abutment interface. All samples were then cleaned in ultrasonic bath for 10 min (Beijing Ultrasonic Co., Beijing, China). Finally, all the test specimens were washed thoroughly with ethyl alcohol and dried (Fig. 2).

Fit evaluation

The marginal fit at implant-abutment interface of each prepared sample was scanned by using high resolution scanning electron microscope (SEM), the analysis was carried out on a FEI Quanta FEG 250 (Thermo Fisher Scientific, Eindhoven, The Netherlands) instrument. In each sample, 3 measuring points on each side (top, middle, and bottom) with total 6 points at the implant– abutment interface, were selected for measurement of the vertical marginal fit between the abutment margin and the internal conical connection surface angle of the implant platform. The selected working parameters for the samples were at 800× magnification and the photomicrographs were obtained in separate images to aid in accurate measurement of the fit. The interface fit was then measured on the scanning electron microscopic images obtained for each test sample using an image measuring pixel counting software (Image J, National Institutes for Health). The fit was then measured on the SEM images with the linear measuring scale of the software (Fig. 3).

Statistical analysis

Data were collected, revised, coded, and entered onto the Statistical Package for Social Science (IBM SPSS) version 23. Data were described as mean and standard deviations. Using one-way analysis of variance (ANOVA) test, the comparison between groups were made followed by post hoc test using least significance difference (LSD). The confidence interval was set to 95% and the margin of error accepted was set to 5%. The p-value was considered significant at the level of < 0.05.

Results

There was a significant difference between each of the three studied groups (I vs. II, II vs. III & I vs. III) regarding marginal misfit the between implant and fabricated bars with p-value < 0.001. The highest value of micro-gap distance was found in Co-Cr conventional group (7.95 ± 2.21 μm) followed by Co-Cr 3D printed group (4.98 ± 1.73) and the lower value were found in Co-Cr milled (3.22 ± 0.75) (Table 1).
Table 1
Number of readings and mean gap distance from SEM taken for the whole sample used in the experiment
Grouping
Manufacturing Technique
Number of implants
Total number of readings
Mean ± SD (µm)
P-value
Group (I)
Co-Cr conv
20
20 × 6 = 120
7.95 ± 2.21
< 0.001
Group (II)
Co-Cr milled
20
20 × 6 = 120
3.22 ± 0.75
Group (III)
Co-Cr print
20
20 × 6 = 120
4.98 ± 1.73

Discussion

The rationale behind comparing different manufacturing techniques in bar cases used in this study is built on the increasing demand for customization of abutments for different clinical conditions. Generally, custom abutments allow the clinician to develop the prosthesis emergence profile with customization of the cervical margins comparable to the anatomy of a natural tooth and to compensate for improper implant angulation. Furthermore, custom made abutments can be fabricated out from different materials including metal alloys as Titanium and Cobalt Chromium, ceramics, and resin materials [30, 31].
Taking into consideration that the abutment-implant interface plays a major role on the success and long-term stability of implant-supported rehabilitations, it becomes paramount to inspect the influence of different manufacturing methods on the internal fit and accuracy at the implant-abutment interface.
Technically, gaps and misfits between the implant and abutment are unavoidable. It is impossible for such components to accurately match with zero gap because of the precision limitation during the manufacturing procedures and some amount of micro leakage will be inevitable regardless of the type of connection. The amount of these micro gaps and their clinical significance have been getting remarkable attention [4, 7, 32, 33]. Accordingly, different proposed methods have been employed to measure those micro gaps including the use of direct visualization under optical microscope [34], or traveling microscope [35] microtomography [36], and the analyzing method under scanning electron microscopy (SEM) [37], for either sectioned or embedded specimens and the use of a silicone replica. Although these techniques are well recognized, nevertheless, it is impossible to be used in vivo and several authors agreed that these measurements could involve unavoidable human errors, along with the non-standardized evaluation areas [38, 39]. The size of the micro-gaps has been described to range from 1 to 60 μm [34, 39]. The size of micro-gap could be related to manufacturing process, implant system used, and the torque applied to fix the abutments to the implant [32, 40].
The available scientific reports concerning the use of Co-Cr alloy in either single or multiple implant restorations is scarce. Although, the precision fit of different materials as titanium and zirconia abutments has been widely studied [41, 42]. Fernandez et al. [43] compared the marginal fit of Co-Cr custommade abutments with implant having an external hexagonal connection utilizing three different manufacturing procedures: the conventional cast, printing, and milling in an invitro study. They reported the least marginal misfit of implant abutment interface in milled abutments (0.73 μm), followed by cast abutments (9.09 μm) and printed abutments (11.30 μm) with no statistically significant difference between cast and printed abutments. Gonzalo et al. [44] reported the marginal fit in both milled titanium and printed Co-Cr abutment in internal hexagon connection design for different implant systems at implantabutment interface. The mean marginal misfit for the milled titanium abutments was reported to be (0.75 ± 1.27 μm) while in the CoCr laser printed abutments was (11.83 ± 13.21 μm).
The results obtained in the present study agreed with the null hypothesis that there is a difference exists in the marginal fit of Co-Cr customized bars fabricated using different manufacturing processes. Significant differences were observed in the studied groups. Several studies reported that the micro gap of less than 10 μm should be considered acceptable [45, 46]. The marginal fit of all tested groups was within the clinically acceptable range. The marginal fit of the milled Co-Cr was 3.22 ± 0.75 μm, printed Co-Cr 3D was 4.98 ± 1.73 μm and for conventional Co-Cr was 7.95 ± 2.21 μm. Although the differences may be statistically significant but may not be clinically relevant.
The possible clarifications for the marginal misfit of the milled Co-Cr (3.22 ± 0.75 μm) could be related to factors associated in the milling process itself. These factors could be the alteration in the radius of the instruments during the milling procedure, the wear of the milling tools and the size of the milling drills [47]. Mobilio et al. [34] reported that the tolerance set for fabrication of either screw retained abutments or crowns during CAD/CAM procedure could have a major role in their final fit to implant. The study claimed that reduction in tolerance values by 10-µm could increase the attrition and, subsequently, the vertical fit between the components.
The marginal misfit of the printed Co-Cr bar was (4.98 ± 1.73 μm). The highest marginal misfit was recorded for the conventional cast Co-Cr bar (7.95 ± 2.21 μm). Several literatures reported that laser sintering could cause some distortion and porosity that generate rough connection between bar and implant creating micro gaps and inhibiting complete passive fit [48, 49]. It was also reported that radiographic evaluations of Co-Cr dental alloys fabricated using casting, milling, and sintering procedures revealed minimal porosities on the milled and sintering specimens and gross porosities on the cast specimens [50]. This might be expected regarding the expansion of investment materials used that could cause some distortion in the implant-abutment fit [10, 22].
One of the limitations of the present study was that it’s an invitro study involving only internal implant connection. Additional points for future investigations can focus on the influence of implant connection either external or internal connections on marginal fit. Also, the role of different bar materials as titanium alloys and zirconia. The limitation of the present study was utilizing the vertical cross-section technique to measure the gap distance and the fit. As a result, the precision was assessed only at a few defined areas per each implant, and this might not totally demonstrate the complete geometry of internal fit. Cross sectioning procedure by itself could cause some damage to the specimens. Also, the effect of cyclic loading on the precision of fit was not included in the study. Furthermore, research evaluates the impact of marginal misfit on biomechanical performance in vivo and their clinical significance.

Conclusions

Within the limitations of this study, the following conclusions may be drawn: The marginal fit of milled, 3D printed and conventional cast for Co-Cr alloy were within the clinically acceptable range of misfit. CAD/CAM milled Co-Cr bar revealed a superior internal fit at the implant-abutment interface. This was followed by selective laser melting (SLM) 3D printed bar and the least fit was shown for customized bar with the conventional lost wax technique.

Acknowledgements

The authors thank Professor Dr Hussien Elcharkawi (head of the prosthodontics department, Faculty of Oral and Dental Medicine, Future University in Egypt).

Declarations

Not Applicable (In-vitro study) (Laboratory procedures).
Not Applicable.

Competing interests

The authors declare no competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant‐supported single crowns. Clin Oral Implants Res. 2008;19(2):119–30.CrossRefPubMed Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant‐supported single crowns. Clin Oral Implants Res. 2008;19(2):119–30.CrossRefPubMed
2.
Zurück zum Zitat Sailer I, Philipp A, Zembic A, Pjetursson BE, Hämmerle CH, Zwahlen M. A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions. Clin Oral Implants Res. 2009;20:4–31.CrossRefPubMed Sailer I, Philipp A, Zembic A, Pjetursson BE, Hämmerle CH, Zwahlen M. A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions. Clin Oral Implants Res. 2009;20:4–31.CrossRefPubMed
3.
Zurück zum Zitat Alqutaibi AY, Aboalrejal AN. Microgap and micromotion at the implant abutment interface cause marginal bone loss around dental implant but more evidence is needed. J Evid Based Dent Pract. 2018;18(2):171–2.CrossRefPubMed Alqutaibi AY, Aboalrejal AN. Microgap and micromotion at the implant abutment interface cause marginal bone loss around dental implant but more evidence is needed. J Evid Based Dent Pract. 2018;18(2):171–2.CrossRefPubMed
4.
Zurück zum Zitat Liu Y, Wang J. Influences of microgap and micromotion of implant–abutment interface on marginal bone loss around implant neck. Arch Oral Biol. 2017;83:153–60.CrossRefPubMed Liu Y, Wang J. Influences of microgap and micromotion of implant–abutment interface on marginal bone loss around implant neck. Arch Oral Biol. 2017;83:153–60.CrossRefPubMed
5.
Zurück zum Zitat Katsoulis J, Takeichi T, Sol Gaviria A, Peter L, Katsoulis K. Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature. Eur J Oral Implantol. 2017;10(Suppl 1):121–38.PubMed Katsoulis J, Takeichi T, Sol Gaviria A, Peter L, Katsoulis K. Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature. Eur J Oral Implantol. 2017;10(Suppl 1):121–38.PubMed
6.
Zurück zum Zitat Priest G. Virtual-designed and computer-milled implant abutments. J Oral Maxillofac Surg. 2005;63(9):22–32.CrossRefPubMed Priest G. Virtual-designed and computer-milled implant abutments. J Oral Maxillofac Surg. 2005;63(9):22–32.CrossRefPubMed
7.
Zurück zum Zitat Bondan JL, Oshima H, Shinkai RS, Mota EG, Meyer KR. Marginal fit analysis of premachined and castable UCLA abutments. Acta Odontológica Latinoamericana. 2009;22(2):139–42.PubMed Bondan JL, Oshima H, Shinkai RS, Mota EG, Meyer KR. Marginal fit analysis of premachined and castable UCLA abutments. Acta Odontológica Latinoamericana. 2009;22(2):139–42.PubMed
8.
Zurück zum Zitat Silva CE, Soares S, Machado CM, Bergamo ET, Coelho PG, Witek L, Ramalho IS, Jalkh EB, Bonfante EA. Effect of CAD/CAM abutment height and cement type on the retention of zirconia crowns. Implant Dent. 2018;27(5):582–7.CrossRefPubMed Silva CE, Soares S, Machado CM, Bergamo ET, Coelho PG, Witek L, Ramalho IS, Jalkh EB, Bonfante EA. Effect of CAD/CAM abutment height and cement type on the retention of zirconia crowns. Implant Dent. 2018;27(5):582–7.CrossRefPubMed
9.
Zurück zum Zitat Lopes AC, Machado CM, Bonjardim LR, Bergamo ET, Ramalho IS, Witek L, Coelho PG, Bonfante EA. The effect of CAD/CAM crown material and cement type on retention to implant abutments. J Prosthodont. 2019;28(2):e552–6.CrossRefPubMed Lopes AC, Machado CM, Bonjardim LR, Bergamo ET, Ramalho IS, Witek L, Coelho PG, Bonfante EA. The effect of CAD/CAM crown material and cement type on retention to implant abutments. J Prosthodont. 2019;28(2):e552–6.CrossRefPubMed
10.
Zurück zum Zitat Gigandet M, Bigolin G, Faoro F, Bürgin W, Brägger U. Implants with original and non-original abutment connections. Clin Implant Dent Relat Res. 2014;16(2):303–11.CrossRefPubMed Gigandet M, Bigolin G, Faoro F, Bürgin W, Brägger U. Implants with original and non-original abutment connections. Clin Implant Dent Relat Res. 2014;16(2):303–11.CrossRefPubMed
11.
Zurück zum Zitat Abdelhamed MI, Galley JD, Bailey MT, Johnston WM, Holloway J, McGlumphy E, et al. A comparison of Zirconia and Titanium abutments for Microleakage. Clin Implant Dent Relat Res. 2015;17(Suppl 2):e643–51.PubMed Abdelhamed MI, Galley JD, Bailey MT, Johnston WM, Holloway J, McGlumphy E, et al. A comparison of Zirconia and Titanium abutments for Microleakage. Clin Implant Dent Relat Res. 2015;17(Suppl 2):e643–51.PubMed
12.
Zurück zum Zitat Molinero-Mourelle P, Cascos-Sanchez R, Yilmaz B, Lam WYH, Pow EHN, Del Río Highsmith J et al. Effect of fabrication technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia abutments on a conical connection Implant: an in Vitro Study. Mater (Basel). 2021;14(9). Molinero-Mourelle P, Cascos-Sanchez R, Yilmaz B, Lam WYH, Pow EHN, Del Río Highsmith J et al. Effect of fabrication technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia abutments on a conical connection Implant: an in Vitro Study. Mater (Basel). 2021;14(9).
13.
Zurück zum Zitat Pjetursson BE, Thoma D, Jung R, Zwahlen M, Zembic A. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years. Clin Oral Implants Res. 2012;23(Suppl 6):22–38.CrossRefPubMed Pjetursson BE, Thoma D, Jung R, Zwahlen M, Zembic A. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years. Clin Oral Implants Res. 2012;23(Suppl 6):22–38.CrossRefPubMed
14.
Zurück zum Zitat Kim MJ, Choi YJ, Kim SK, Heo SJ, Koak JY. Marginal accuracy and internal fit of 3-D Printing Laser-Sintered Co-cr Alloy Copings. Mater (Basel). 2017;10(1). Kim MJ, Choi YJ, Kim SK, Heo SJ, Koak JY. Marginal accuracy and internal fit of 3-D Printing Laser-Sintered Co-cr Alloy Copings. Mater (Basel). 2017;10(1).
15.
Zurück zum Zitat Abduo J. Fit of CAD/CAM implant frameworks: a comprehensive review. J Oral Implantology. 2014;40(6):758–66.CrossRefPubMed Abduo J. Fit of CAD/CAM implant frameworks: a comprehensive review. J Oral Implantology. 2014;40(6):758–66.CrossRefPubMed
16.
Zurück zum Zitat Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: a critical review. Int J Oral Maxillofacial Implants. 2010;25(3). Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: a critical review. Int J Oral Maxillofacial Implants. 2010;25(3).
17.
Zurück zum Zitat Blatz MB, Conejo J. The current state of chairside digital dentistry and materials. Dent Clin. 2019;63(2):175–97. Blatz MB, Conejo J. The current state of chairside digital dentistry and materials. Dent Clin. 2019;63(2):175–97.
18.
Zurück zum Zitat Chen J, Xiao Z, Yangpeng S, Deng F, Zhiguang Z. Production of inter-connective porous dental implants by computer-aided design and metal three-dimensional printing. J Biomater Appl. 2020;34(9):1227–38.CrossRefPubMed Chen J, Xiao Z, Yangpeng S, Deng F, Zhiguang Z. Production of inter-connective porous dental implants by computer-aided design and metal three-dimensional printing. J Biomater Appl. 2020;34(9):1227–38.CrossRefPubMed
19.
Zurück zum Zitat Pereira T, Kennedy JV, Potgieter J. A comparison of traditional manufacturing vs additive manufacturing, the best method for the job. Procedia Manuf. 2019;30:11–8.CrossRef Pereira T, Kennedy JV, Potgieter J. A comparison of traditional manufacturing vs additive manufacturing, the best method for the job. Procedia Manuf. 2019;30:11–8.CrossRef
20.
Zurück zum Zitat Oliveira TT, Reis AC. Fabrication of dental implants by the additive manufacturing method: a systematic review. J Prosthet Dent. 2019;122(3):270–4.CrossRefPubMed Oliveira TT, Reis AC. Fabrication of dental implants by the additive manufacturing method: a systematic review. J Prosthet Dent. 2019;122(3):270–4.CrossRefPubMed
21.
Zurück zum Zitat Wally ZJ, Haque AM, Feteira A, Claeyssens F, Goodall R, Reilly GC. Selective laser melting processed Ti6Al4V lattices with graded porosities for dental applications. J Mech Behav Biomed Mater. 2019;90:20–9.CrossRefPubMed Wally ZJ, Haque AM, Feteira A, Claeyssens F, Goodall R, Reilly GC. Selective laser melting processed Ti6Al4V lattices with graded porosities for dental applications. J Mech Behav Biomed Mater. 2019;90:20–9.CrossRefPubMed
22.
Zurück zum Zitat Mangano C, Bianchi A, Mangano FG, Dana J, Colombo M, Solop I, Admakin O. Custom-made 3D printed subperiosteal titanium implants for the prosthetic restoration of the atrophic posterior mandible of elderly patients: a case series. 3D Print Med. 2020;6(1):1–4.PubMedCentralCrossRefPubMed Mangano C, Bianchi A, Mangano FG, Dana J, Colombo M, Solop I, Admakin O. Custom-made 3D printed subperiosteal titanium implants for the prosthetic restoration of the atrophic posterior mandible of elderly patients: a case series. 3D Print Med. 2020;6(1):1–4.PubMedCentralCrossRefPubMed
23.
Zurück zum Zitat Mounir M, Atef M, Abou-Elfetouh A, Hakam MM. Titanium and polyether ether ketone (PEEK) patient-specific sub-periosteal implants: two novel approaches for rehabilitation of the severely atrophic anterior maxillary ridge. Int J Oral Maxillofac Surg. 2018;47(5):658–64.CrossRefPubMed Mounir M, Atef M, Abou-Elfetouh A, Hakam MM. Titanium and polyether ether ketone (PEEK) patient-specific sub-periosteal implants: two novel approaches for rehabilitation of the severely atrophic anterior maxillary ridge. Int J Oral Maxillofac Surg. 2018;47(5):658–64.CrossRefPubMed
24.
Zurück zum Zitat Wang Y, Chen X, Zhang C, Feng W, Zhang P, Chen Y, Huang J, Luo Y, Chen J. Studies on the performance of selective laser melting porous dental implant by finite element model simulation, fatigue testing and in vivo experiments. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2019;233(2):170 – 80. Wang Y, Chen X, Zhang C, Feng W, Zhang P, Chen Y, Huang J, Luo Y, Chen J. Studies on the performance of selective laser melting porous dental implant by finite element model simulation, fatigue testing and in vivo experiments. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2019;233(2):170 – 80.
25.
Zurück zum Zitat Hartmann A, Hildebrandt H, Schmohl JU, Kämmerer PW. Evaluation of risk parameters in bone regeneration using a customized titanium mesh: results of a clinical study. Implant Dent. 2019;28(6):543–50.PubMed Hartmann A, Hildebrandt H, Schmohl JU, Kämmerer PW. Evaluation of risk parameters in bone regeneration using a customized titanium mesh: results of a clinical study. Implant Dent. 2019;28(6):543–50.PubMed
26.
Zurück zum Zitat Hartmann A, Seiler M. Minimizing risk of customized titanium mesh exposures–a retrospective analysis. BMC Oral Health. 2020;20(1):1–9.CrossRef Hartmann A, Seiler M. Minimizing risk of customized titanium mesh exposures–a retrospective analysis. BMC Oral Health. 2020;20(1):1–9.CrossRef
27.
Zurück zum Zitat Revilla-León M, Ceballos L, Martínez-Klemm I, Özcan M. Discrepancy of complete-arch titanium frameworks manufactured using selective laser melting and electron beam melting additive manufacturing technologies. J Prosthet Dent. 2018;120(6):942–7.CrossRefPubMed Revilla-León M, Ceballos L, Martínez-Klemm I, Özcan M. Discrepancy of complete-arch titanium frameworks manufactured using selective laser melting and electron beam melting additive manufacturing technologies. J Prosthet Dent. 2018;120(6):942–7.CrossRefPubMed
28.
Zurück zum Zitat Revilla-León M, Ceballos L, Özcan M. Implant-Prosthodontic discrepancy of Complete-Arch Cobalt-Chromium Implant frameworks Manufactured through Selective Laser Melting Additive Manufacturing Technology using a coordinate measuring machine. Int J Oral Maxillofacial Implants. 2019;34(3). Revilla-León M, Ceballos L, Özcan M. Implant-Prosthodontic discrepancy of Complete-Arch Cobalt-Chromium Implant frameworks Manufactured through Selective Laser Melting Additive Manufacturing Technology using a coordinate measuring machine. Int J Oral Maxillofacial Implants. 2019;34(3).
29.
Zurück zum Zitat Ciocca L, Meneghello R, Savio G, Scheda L, Monaco C, Gatto MR, Micarelli C, Baldissara P. Manufacturing of metal frameworks for full-arch dental restoration on implants: a comparison between milling and a novel hybrid technology. J Prosthodont. 2019;28(5):556–63.CrossRefPubMed Ciocca L, Meneghello R, Savio G, Scheda L, Monaco C, Gatto MR, Micarelli C, Baldissara P. Manufacturing of metal frameworks for full-arch dental restoration on implants: a comparison between milling and a novel hybrid technology. J Prosthodont. 2019;28(5):556–63.CrossRefPubMed
30.
Zurück zum Zitat Kurbada A, Kurbadb S. CAD/CAM-based Implant Abutments Made of Lithium Disilicate CAD/CAM-basierte Implantatabutments aus Lithiumdisilikat. Int J Comput Dent. 2013;16:125–41. Kurbada A, Kurbadb S. CAD/CAM-based Implant Abutments Made of Lithium Disilicate CAD/CAM-basierte Implantatabutments aus Lithiumdisilikat. Int J Comput Dent. 2013;16:125–41.
31.
Zurück zum Zitat Kapos T, Evans C. CAD/CAM technology for implant abutments, crowns, and superstructures. Int J Oral Maxillofacial Implants. 2014;29. Kapos T, Evans C. CAD/CAM technology for implant abutments, crowns, and superstructures. Int J Oral Maxillofacial Implants. 2014;29.
32.
Zurück zum Zitat Mishra SK, Chowdhary R, Kumari S. Microleakage at the different implant abutment interface: a systematic review. J Clin Diagn Research: JCDR. 2017;11(6):ZE10. Mishra SK, Chowdhary R, Kumari S. Microleakage at the different implant abutment interface: a systematic review. J Clin Diagn Research: JCDR. 2017;11(6):ZE10.
33.
Zurück zum Zitat Alves DC, de Carvalho PS, Elias CN, Vedovatto E, Martinez EF. In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling. Clin Oral Invest. 2016;20(9):2437–45.CrossRef Alves DC, de Carvalho PS, Elias CN, Vedovatto E, Martinez EF. In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling. Clin Oral Invest. 2016;20(9):2437–45.CrossRef
34.
Zurück zum Zitat Mobilio N, Fasiol A, Franceschetti G, Catapano S. Marginal vertical fit along the implant-abutment interface: a microscope qualitative analysis. Dentistry J. 2016;4(3):31.CrossRef Mobilio N, Fasiol A, Franceschetti G, Catapano S. Marginal vertical fit along the implant-abutment interface: a microscope qualitative analysis. Dentistry J. 2016;4(3):31.CrossRef
35.
Zurück zum Zitat Jörn D, Kohorst P, Besdo S, Borchers L, Stiesch M. Three-dimensional nonlinear finite element analysis and Microcomputed Tomography evaluation of Microgap formation in a Dental Implant under Oblique Loading. Int J Oral Maxillofacial Implants. 2016;31(3). Jörn D, Kohorst P, Besdo S, Borchers L, Stiesch M. Three-dimensional nonlinear finite element analysis and Microcomputed Tomography evaluation of Microgap formation in a Dental Implant under Oblique Loading. Int J Oral Maxillofacial Implants. 2016;31(3).
36.
Zurück zum Zitat Rismanchian M, Hatami M, Badrian H, Khalighinejad N, Goroohi H. Evaluation of microgap size and microbial leakage in the connection area of 4 abutments with Straumann (ITI) implant. J Oral Implantology. 2012;38(6):677–85.CrossRefPubMed Rismanchian M, Hatami M, Badrian H, Khalighinejad N, Goroohi H. Evaluation of microgap size and microbial leakage in the connection area of 4 abutments with Straumann (ITI) implant. J Oral Implantology. 2012;38(6):677–85.CrossRefPubMed
37.
Zurück zum Zitat Lops D, Meneghello R, Sbricoli L, Savio G, Bressan E, Stellini E. Precision of the connection between Implant and Standard or computer-aided Design/Computer-Aided Manufacturing abutments: a novel evaluation method. Int J Oral Maxillofacial Implants. 2018;33(1). Lops D, Meneghello R, Sbricoli L, Savio G, Bressan E, Stellini E. Precision of the connection between Implant and Standard or computer-aided Design/Computer-Aided Manufacturing abutments: a novel evaluation method. Int J Oral Maxillofacial Implants. 2018;33(1).
38.
Zurück zum Zitat Kim MJ, Choi YJ, Kim SK, Heo SJ, Koak JY. Marginal accuracy and internal fit of 3-D printing laser-sintered co-cr alloy copings. Materials. 2017;10(1):93.PubMedCentralCrossRefPubMed Kim MJ, Choi YJ, Kim SK, Heo SJ, Koak JY. Marginal accuracy and internal fit of 3-D printing laser-sintered co-cr alloy copings. Materials. 2017;10(1):93.PubMedCentralCrossRefPubMed
39.
Zurück zum Zitat Tsuge T, Hagiwara Y, Matsumura H. Marginal fit and microgaps of implant-abutment interface with internal anti-rotation configuration. Dent Mater J. 2008;27(1):29–34.CrossRefPubMed Tsuge T, Hagiwara Y, Matsumura H. Marginal fit and microgaps of implant-abutment interface with internal anti-rotation configuration. Dent Mater J. 2008;27(1):29–34.CrossRefPubMed
40.
Zurück zum Zitat Baggi L, Di Girolamo M, Mirisola C, Calcaterra R. Microbiological evaluation of bacterial and mycotic seal in implant systems with different implant-abutment interfaces and closing torque values. Implant Dent. 2013;22(4):344–50.CrossRefPubMed Baggi L, Di Girolamo M, Mirisola C, Calcaterra R. Microbiological evaluation of bacterial and mycotic seal in implant systems with different implant-abutment interfaces and closing torque values. Implant Dent. 2013;22(4):344–50.CrossRefPubMed
41.
Zurück zum Zitat Jeong KW, Kim SH, Şen N, Şermet IB, Gürler N. Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs. J Adv Prosthodont. 2019;11(2):105–11.CrossRef Jeong KW, Kim SH, Şen N, Şermet IB, Gürler N. Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs. J Adv Prosthodont. 2019;11(2):105–11.CrossRef
42.
Zurück zum Zitat Vélez J, Peláez J, López-Suárez C, Agustín-Panadero R, Tobar C, Suárez MJ. Influence of implant connection, abutment design and screw insertion torque on implant-abutment misfit. J Clin Med. 2020;9(8):2365.PubMedCentralCrossRefPubMed Vélez J, Peláez J, López-Suárez C, Agustín-Panadero R, Tobar C, Suárez MJ. Influence of implant connection, abutment design and screw insertion torque on implant-abutment misfit. J Clin Med. 2020;9(8):2365.PubMedCentralCrossRefPubMed
43.
Zurück zum Zitat Fernández M, Delgado L, Molmeneu M, García D, Rodríguez D. Analysis of the misfit of dental implant-supported prostheses made with three manufacturing processes. J Prosthet Dent. 2014;111(2):116–23.CrossRefPubMed Fernández M, Delgado L, Molmeneu M, García D, Rodríguez D. Analysis of the misfit of dental implant-supported prostheses made with three manufacturing processes. J Prosthet Dent. 2014;111(2):116–23.CrossRefPubMed
44.
Zurück zum Zitat Gonzalo E, Vizoso B, Lopez-Suarez C, Diaz P, Pelaez J, Suarez MJ. Evaluation of milled titanium versus laser sintered co-cr abutments on the marginal misfit in internal implant-abutment connection. Materials. 2020;13(21):4873.PubMedCentralCrossRefPubMed Gonzalo E, Vizoso B, Lopez-Suarez C, Diaz P, Pelaez J, Suarez MJ. Evaluation of milled titanium versus laser sintered co-cr abutments on the marginal misfit in internal implant-abutment connection. Materials. 2020;13(21):4873.PubMedCentralCrossRefPubMed
45.
Zurück zum Zitat Do Nascimento C, Pita MS, de Souza Santos E, Monesi N, Pedrazzi V, de Albuquerque Junior RF, Ribeiro RF. Microbiome of titanium and zirconia dental implants abutments. Dent Mater. 2016;32(1):93–101.CrossRef Do Nascimento C, Pita MS, de Souza Santos E, Monesi N, Pedrazzi V, de Albuquerque Junior RF, Ribeiro RF. Microbiome of titanium and zirconia dental implants abutments. Dent Mater. 2016;32(1):93–101.CrossRef
46.
Zurück zum Zitat El Haddad E, Giannì AB, Mancini GE, Cura F, Carinci F. Implant-Abutment leaking of replace conical connection nobel biocare® implant system. An in vitro study of the microbiological penetration from external environment to implant-abutment space. Oral & Implantology. 2016;9(2):76. El Haddad E, Giannì AB, Mancini GE, Cura F, Carinci F. Implant-Abutment leaking of replace conical connection nobel biocare® implant system. An in vitro study of the microbiological penetration from external environment to implant-abutment space. Oral & Implantology. 2016;9(2):76.
47.
Zurück zum Zitat Papadiochou S, Pissiotis AL. Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques. J Prosthet Dent. 2018;119(4):545–51.CrossRefPubMed Papadiochou S, Pissiotis AL. Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques. J Prosthet Dent. 2018;119(4):545–51.CrossRefPubMed
48.
Zurück zum Zitat Song B, Zhao X, Li S, Han C, Wei Q, Wen S, Liu J, Shi Y. Differences in microstructure and properties between selective laser melting and traditional manufacturing for fabrication of metal parts: a review. Front Mech Eng. 2015;10(2):111–25.CrossRef Song B, Zhao X, Li S, Han C, Wei Q, Wen S, Liu J, Shi Y. Differences in microstructure and properties between selective laser melting and traditional manufacturing for fabrication of metal parts: a review. Front Mech Eng. 2015;10(2):111–25.CrossRef
49.
Zurück zum Zitat Yap CY, Chua CK, Dong ZL, Liu ZH, Zhang DQ, Loh LE, Sing SL. Review of selective laser melting: materials and applications. Appl Phys Reviews. 2015;2(4):041101.CrossRef Yap CY, Chua CK, Dong ZL, Liu ZH, Zhang DQ, Loh LE, Sing SL. Review of selective laser melting: materials and applications. Appl Phys Reviews. 2015;2(4):041101.CrossRef
50.
Zurück zum Zitat Al Jabbari YS, Koutsoukis T, Barmpagadaki X, Zinelis S. Metallurgical and interfacial characterization of PFM Co–Cr dental alloys fabricated via casting, milling or selective laser melting. Dent Mater. 2014;30(4):e79–88.CrossRefPubMed Al Jabbari YS, Koutsoukis T, Barmpagadaki X, Zinelis S. Metallurgical and interfacial characterization of PFM Co–Cr dental alloys fabricated via casting, milling or selective laser melting. Dent Mater. 2014;30(4):e79–88.CrossRefPubMed
Metadaten
Titel
Accuracy of fit for cobaltchromium bar over two implants fabricated with different manufacturing techniques: an in-vitro study
verfasst von
Hossam I. Nassar
Ayman Fateen
Publikationsdatum
01.12.2023
Verlag
BioMed Central
Erschienen in
BMC Oral Health / Ausgabe 1/2023
Elektronische ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-03700-w

Weitere Artikel der Ausgabe 1/2023

BMC Oral Health 1/2023 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.