Skip to main content
Erschienen in: Pediatric Radiology 7/2014

01.07.2014 | Original Article

Clinical-radiologic features and treatment of hepatic lesions caused by inadvertent infusion of parenteral nutrition in liver parenchyma due to malposition of umbilical vein catheters

verfasst von: Heidi E. Hagerott, Sakil Kulkarni, Ricardo Restrepo, Jesse Reeves-Garcia

Erschienen in: Pediatric Radiology | Ausgabe 7/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

Umbilical venous catheterization is a common procedure performed in neonatal intensive care units. Hepatic collections due to inadvertent extravasation of parenteral nutrition into the liver have been described previously in literature.

Objective

To recognize the clinicoradiologic features and treatment options of hepatic collections due to inadvertent extravasation of parenteral nutrition fluids caused by malpositioning of umbilical venous catheter (UVC) in the portal venous system.

Materials and methods

This is a case series describing five neonates during a 6-year period at a single tertiary care referral center, with extravasation of parenteral nutrition into the liver parenchyma causing hepatic collections.

Results

All five neonates receiving parenteral nutrition presented with abdominal distension in the second week of life. Two out of five (40%) had anemia requiring blood transfusion and 3/5 (60%) had hemodynamic instability at presentation. Ultrasound of the liver confirmed the diagnosis in all the cases. Three of the five (60%) cases underwent US-guided aspiration of the collections, one case underwent conservative management and one case required emergent laparotomy due to abdominal compartment syndrome. US used in follow-up of these cases revealed decrease in size of the lesions and/or development of calcifications.

Conclusion

Early recognition of this complication, prompt diagnosis with US of liver and timely treatment can lead to better outcome in newborns with hepatic collections secondary to inadvertent parenteral nutrition infusion via malposition of UVC.
Literatur
1.
Zurück zum Zitat Diamond LK (1947) Erythroblastosis faetalis or haemolytic disease of the newborn. Proc R Soc Med 40:456–550 Diamond LK (1947) Erythroblastosis faetalis or haemolytic disease of the newborn. Proc R Soc Med 40:456–550
2.
Zurück zum Zitat Kabra NS, Kumar M, Shah SS (2005) Multiple versus single lumen catheters for newborn infants. Cochrane Database Syst Rev 20:CD004498 Kabra NS, Kumar M, Shah SS (2005) Multiple versus single lumen catheters for newborn infants. Cochrane Database Syst Rev 20:CD004498
3.
Zurück zum Zitat Sequin J, Fletcher MA, Landers S et al (1994) Umbilical venous catheterizations: audit by the Study Group for Complications of Perinatal Care. Am J Perinatol 11:67–70CrossRef Sequin J, Fletcher MA, Landers S et al (1994) Umbilical venous catheterizations: audit by the Study Group for Complications of Perinatal Care. Am J Perinatol 11:67–70CrossRef
4.
Zurück zum Zitat Greenberg M, Movahed H, Peterson B et al (1995) Placement of umbilical venous catheters with use of bedside real-time ultrasonography. J Pediatr 126:633–635PubMedCrossRef Greenberg M, Movahed H, Peterson B et al (1995) Placement of umbilical venous catheters with use of bedside real-time ultrasonography. J Pediatr 126:633–635PubMedCrossRef
5.
Zurück zum Zitat Yigiter M, Arda IS, Hicsonmez A (2008) Hepatic laceration because of malpositioning of the umbilical vein catheter: case report and literature review. J Pediatr Surg 43:E39–E41PubMedCrossRef Yigiter M, Arda IS, Hicsonmez A (2008) Hepatic laceration because of malpositioning of the umbilical vein catheter: case report and literature review. J Pediatr Surg 43:E39–E41PubMedCrossRef
6.
Zurück zum Zitat Lam HS, Li AM, Chu WC et al (2005) Mal-positioned umbilical venous catheter causing liver abscess in a preterm infant. Biol Neonate 88:54–56PubMedCrossRef Lam HS, Li AM, Chu WC et al (2005) Mal-positioned umbilical venous catheter causing liver abscess in a preterm infant. Biol Neonate 88:54–56PubMedCrossRef
7.
Zurück zum Zitat Levkoff AH, Macpherson RI (1990) Intrahepatic encystment of umbilical vein catheter infusate. Pediatr Radiol 20:360–361PubMedCrossRef Levkoff AH, Macpherson RI (1990) Intrahepatic encystment of umbilical vein catheter infusate. Pediatr Radiol 20:360–361PubMedCrossRef
8.
Zurück zum Zitat Verheij GH, Te Pas AB, Witlox RS et al (2010) Poor accuracy of methods currently used to determine umbilical catheter insertion length. Int J Pediatr 873167. doi:10.1155/2010/873167 Verheij GH, Te Pas AB, Witlox RS et al (2010) Poor accuracy of methods currently used to determine umbilical catheter insertion length. Int J Pediatr 873167. doi:10.​1155/​2010/​873167
9.
Zurück zum Zitat Lin-Dunham JE, Vade A, Capitano HN et al (2007) Characteristic sonographic findings of hepatic erosion of umbilical vein catheters. J Ultrasound Med 26:661–666 Lin-Dunham JE, Vade A, Capitano HN et al (2007) Characteristic sonographic findings of hepatic erosion of umbilical vein catheters. J Ultrasound Med 26:661–666
10.
Zurück zum Zitat Coley B, Seguin J, Cordero L et al (1998) Neonatal total parenteral nutrition ascites from liver erosion by umbilical vein catheters. Pediatr Radiol 28:923–927PubMedCrossRef Coley B, Seguin J, Cordero L et al (1998) Neonatal total parenteral nutrition ascites from liver erosion by umbilical vein catheters. Pediatr Radiol 28:923–927PubMedCrossRef
11.
Zurück zum Zitat Ades A, Sable C, Cummings S et al (2003) Echocardiographic evaluation of umbilical venous catheter placement. J Perinatol 23:24–28PubMedCrossRef Ades A, Sable C, Cummings S et al (2003) Echocardiographic evaluation of umbilical venous catheter placement. J Perinatol 23:24–28PubMedCrossRef
12.
Zurück zum Zitat Oestreich AE (2010) Umbilical vein catheterization – appropriate and inappropriate placement. Pediatr Radiol 40:1941–1949PubMedCrossRef Oestreich AE (2010) Umbilical vein catheterization – appropriate and inappropriate placement. Pediatr Radiol 40:1941–1949PubMedCrossRef
13.
Zurück zum Zitat Richter E, Lierse W (1991) Imaging atlas of the newborn. Urban & Schwarzenberg, Baltimore Richter E, Lierse W (1991) Imaging atlas of the newborn. Urban & Schwarzenberg, Baltimore
Metadaten
Titel
Clinical-radiologic features and treatment of hepatic lesions caused by inadvertent infusion of parenteral nutrition in liver parenchyma due to malposition of umbilical vein catheters
verfasst von
Heidi E. Hagerott
Sakil Kulkarni
Ricardo Restrepo
Jesse Reeves-Garcia
Publikationsdatum
01.07.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 7/2014
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-014-2895-2

Weitere Artikel der Ausgabe 7/2014

Pediatric Radiology 7/2014 Zur Ausgabe

Hermes

Hermes

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.