Skip to main content
Erschienen in: Lasers in Medical Science 5/2021

03.01.2021 | Original Article

Effect of 940 nm laser diode irradiation prior to bonding procedure on postoperative sensitivity following class II composite restorations: a split-mouth randomized clinical trial

verfasst von: Loghman Rezaei-Soufi, Mojgan Taheri, Reza Fekrazadas, Maryam Farhadian

Erschienen in: Lasers in Medical Science | Ausgabe 5/2021

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to evaluate the effect of 940 nm laser diode on class II composite cavities prior to bonding and restoration process on the postoperative sensitivity (POS). Thirty patients with two bilateral premolars with mesio or disto-occlusal carious lesions were evaluated. In each patient, the teeth were randomly divided into the control and laser groups. After cavity preparation and isolation and before the bonding process, the laser group was subjected to 940 nm irradiation (Epic 10, Biolase, USA) by 400 μ tip continuously at 100 mW with 398 J/cm2 energy density of tip, which was applied for 5 s at a distance of 2 mm on the axial wall of the cavity. In the control group, irradiation was performed by using the aiming beam. Access cavity was then restored with a composite resin. Cold sensitivity was measured using a cold spray application on the middle third of teeth buccal surface at baseline (before the intervention), 1, 14, and 30 days after the restoration by visual analog scale (VAS) criteria. The mean Friedman and Wilcoxon signed-rank tests were used for data analysis. It was shown that in both laser and control groups, the VAS was significantly decreased at all times compared to the baseline (p ≤ 0.05). There was no statistically significant difference between the mean VAS of two groups at baseline and first day (p ≤ 0.05), but at 14 and 30 days after the intervention, it was significantly lower in the laser group (p ≤ 0.05). The results of this study demonstrated that the cavity pretreatment with laser diode (940 nm) effectively reduces the postoperative sensitivity in class II composite restorations.
Literatur
1.
Zurück zum Zitat Auschill T, Koch C, Wolkewitz M, Hellwig E, Arweiler N (2009) Occurrence and causing stimuli of postoperative sensitivity in composite restorations. Oper Dent 34(1):3–10CrossRef Auschill T, Koch C, Wolkewitz M, Hellwig E, Arweiler N (2009) Occurrence and causing stimuli of postoperative sensitivity in composite restorations. Oper Dent 34(1):3–10CrossRef
2.
Zurück zum Zitat Briso ALF, Mestrener SR, Delício G, Sundfeld RH, Bedran-Russo AK, De Alexandre RS, Ambrosano GMB (2007) Clinical assessment of postoperative sensitivity in posterior composite restorations. Oper Dent 32(5):421–426CrossRef Briso ALF, Mestrener SR, Delício G, Sundfeld RH, Bedran-Russo AK, De Alexandre RS, Ambrosano GMB (2007) Clinical assessment of postoperative sensitivity in posterior composite restorations. Oper Dent 32(5):421–426CrossRef
3.
Zurück zum Zitat Arora A, Acharya SR, Vidya SM, Sharma P (2012) A comparative evaluation of dentinal hypersensitivity and microleakage associated with composite restorations in cavities preconditioned with air abrasion-An ex vivo study. Contemp Clin Dent 3(3):306CrossRef Arora A, Acharya SR, Vidya SM, Sharma P (2012) A comparative evaluation of dentinal hypersensitivity and microleakage associated with composite restorations in cavities preconditioned with air abrasion-An ex vivo study. Contemp Clin Dent 3(3):306CrossRef
4.
Zurück zum Zitat Hayashi M, Wilson N (2003) Failure risk of posterior composites with post-operative sensitivity. Oper Dent 28(6):681–688PubMed Hayashi M, Wilson N (2003) Failure risk of posterior composites with post-operative sensitivity. Oper Dent 28(6):681–688PubMed
5.
Zurück zum Zitat Umer F, Khan FR (2011) Postoperative sensitivity in class V composite restorations: comparing soft start vs. constant curing modes of LED. J Conserv Dent 14(1):76CrossRef Umer F, Khan FR (2011) Postoperative sensitivity in class V composite restorations: comparing soft start vs. constant curing modes of LED. J Conserv Dent 14(1):76CrossRef
6.
Zurück zum Zitat Moosavi H, Maleknejad F, Sharifi M, Ahrari F (2015) A randomized clinical trial of the effect of low-level laser therapy before composite placement on postoperative sensitivity in class V restorations. Lasers Med Sci 30(4):1245–1249CrossRef Moosavi H, Maleknejad F, Sharifi M, Ahrari F (2015) A randomized clinical trial of the effect of low-level laser therapy before composite placement on postoperative sensitivity in class V restorations. Lasers Med Sci 30(4):1245–1249CrossRef
7.
Zurück zum Zitat Aboelenein AZ, Riad MI, Haridy MF (2019) Effect of a self-etch adhesive containing nanobioglass on postoperative sensitivity of posterior composite restorations-a randomized trial. Open Access Maced J Med Sci 7(14):2313CrossRef Aboelenein AZ, Riad MI, Haridy MF (2019) Effect of a self-etch adhesive containing nanobioglass on postoperative sensitivity of posterior composite restorations-a randomized trial. Open Access Maced J Med Sci 7(14):2313CrossRef
8.
Zurück zum Zitat Alomari Q, Omar R, Akpata E (2007) Effect of LED curing modes on postoperative sensitivity after class II resin composite restorations. J Adhes Dent 9(5):477PubMed Alomari Q, Omar R, Akpata E (2007) Effect of LED curing modes on postoperative sensitivity after class II resin composite restorations. J Adhes Dent 9(5):477PubMed
9.
Zurück zum Zitat Reis A, Loguercio AD, Schroeder M, Luque-Martinez I, Masterson D, Maia LC (2015) Does the adhesive strategy influence the post-operative sensitivity in adult patients with posterior resin composite restorations?: a systematic review and meta-analysis. Dent Mater 31(9):1052–1067CrossRef Reis A, Loguercio AD, Schroeder M, Luque-Martinez I, Masterson D, Maia LC (2015) Does the adhesive strategy influence the post-operative sensitivity in adult patients with posterior resin composite restorations?: a systematic review and meta-analysis. Dent Mater 31(9):1052–1067CrossRef
10.
Zurück zum Zitat Hajizadeh H, Ghavamnasiri M, Majidinia S (2013) Randomized clinical evaluation of the effect of chlorhexidine on postoperative sensitivity of posterior composite resin restorations. Quintessence Int 44(10)793–8 Hajizadeh H, Ghavamnasiri M, Majidinia S (2013) Randomized clinical evaluation of the effect of chlorhexidine on postoperative sensitivity of posterior composite resin restorations. Quintessence Int 44(10)793–8
11.
Zurück zum Zitat Costa TR, Rezende M, Sakamoto A, Bittencourt B, Dalzochio P, Loguercio AD, Reis A (2017) Influence of adhesive type and placement technique on postoperative sensitivity in posterior composite restorations. Oper Dent 42(2):143–54CrossRef Costa TR, Rezende M, Sakamoto A, Bittencourt B, Dalzochio P, Loguercio AD, Reis A (2017) Influence of adhesive type and placement technique on postoperative sensitivity in posterior composite restorations. Oper Dent 42(2):143–54CrossRef
12.
Zurück zum Zitat Albuquerque NLG, de Souza AMB, de Moraes MDR, Mendonça JS, Rodrigues LKA, Santiago SL (2016) Four-year randomized clinical trial of oxalic acid pretreatment in restorations of non-carious cervical lesions. Clin Oral Investig 20(2):199–205CrossRef Albuquerque NLG, de Souza AMB, de Moraes MDR, Mendonça JS, Rodrigues LKA, Santiago SL (2016) Four-year randomized clinical trial of oxalic acid pretreatment in restorations of non-carious cervical lesions. Clin Oral Investig 20(2):199–205CrossRef
13.
Zurück zum Zitat Manchorova N, Vladimirov S, Donencheva Z, Drashkovich I, Kozhuharov P, Manolov S et al (2006) A study of post-operative sensitivity in class I and class II restorations with self-etching adhesive and nanofilled composite. Folia Med 48(2):63–69 Manchorova N, Vladimirov S, Donencheva Z, Drashkovich I, Kozhuharov P, Manolov S et al (2006) A study of post-operative sensitivity in class I and class II restorations with self-etching adhesive and nanofilled composite. Folia Med 48(2):63–69
14.
Zurück zum Zitat Afifi SMH, Haridy MF, Farid MR (2019) Evaluation of post-operative sensitivity of bulk fill resin composite versus nano resin composite: a randomized controlled clinical study. Open Access Maced J Med Sci 7(14):2335CrossRef Afifi SMH, Haridy MF, Farid MR (2019) Evaluation of post-operative sensitivity of bulk fill resin composite versus nano resin composite: a randomized controlled clinical study. Open Access Maced J Med Sci 7(14):2335CrossRef
15.
Zurück zum Zitat Vilkinis V, Hörsted-Bindslev P, Baelum V (2000) Two-year evaluation of class II resin-modified glass ionomer cement/composite open sandwich and composite restorations. Clin Oral Investig 4(3):133–139CrossRef Vilkinis V, Hörsted-Bindslev P, Baelum V (2000) Two-year evaluation of class II resin-modified glass ionomer cement/composite open sandwich and composite restorations. Clin Oral Investig 4(3):133–139CrossRef
16.
Zurück zum Zitat Akpata E, Sadiq W (2001) Post-operative sensitivity in glass-ionomer versus adhesive resin-lined posterior composites. Am J Dent 14(1):34–38PubMed Akpata E, Sadiq W (2001) Post-operative sensitivity in glass-ionomer versus adhesive resin-lined posterior composites. Am J Dent 14(1):34–38PubMed
17.
Zurück zum Zitat Burrow M, Banomyong D, Harnirattisai C, Messer H (2009) Effect of glass-ionomer cement lining on postoperative sensitivity in occlusal cavities restored with resin composite-a randomized clinical trial. Oper Dent 34(6):648–655CrossRef Burrow M, Banomyong D, Harnirattisai C, Messer H (2009) Effect of glass-ionomer cement lining on postoperative sensitivity in occlusal cavities restored with resin composite-a randomized clinical trial. Oper Dent 34(6):648–655CrossRef
18.
Zurück zum Zitat Femiano F, Femiano R, Lanza A, Lanza M, Perillo L (2017) Effectiveness on oral pain of 808-nm diode laser used prior to composite restoration for symptomatic non-carious cervical lesions unresponsive to desensitizing agents. Laser Med Sci 32(1):67–71CrossRef Femiano F, Femiano R, Lanza A, Lanza M, Perillo L (2017) Effectiveness on oral pain of 808-nm diode laser used prior to composite restoration for symptomatic non-carious cervical lesions unresponsive to desensitizing agents. Laser Med Sci 32(1):67–71CrossRef
19.
Zurück zum Zitat Sicilia A, Cuesta-Frechoso S, Suárez A, Angulo J, Pordomingo A, De Juan P (2009) Immediate efficacy of diode laser application in the treatment of dentine hypersensitivity in periodontal maintenance patients: a randomized clinical trial. J Clin Periodontol 36(8):650–660CrossRef Sicilia A, Cuesta-Frechoso S, Suárez A, Angulo J, Pordomingo A, De Juan P (2009) Immediate efficacy of diode laser application in the treatment of dentine hypersensitivity in periodontal maintenance patients: a randomized clinical trial. J Clin Periodontol 36(8):650–660CrossRef
20.
Zurück zum Zitat Tengrungsun T, Sangkla W (2008) Comparative study in desensitizing efficacy using the GaAlAs laser and dentin bonding agent. J Dent 36(6):392–395CrossRef Tengrungsun T, Sangkla W (2008) Comparative study in desensitizing efficacy using the GaAlAs laser and dentin bonding agent. J Dent 36(6):392–395CrossRef
21.
Zurück zum Zitat Kara HB, Cakan U, Yilmaz B, Inan Kurugol P (2016) Efficacy of diode laser and Gluma on post-preparation sensitivity: a randomized split-mouth clinical study. J Esthet Restor Dent 28(6):405–411CrossRef Kara HB, Cakan U, Yilmaz B, Inan Kurugol P (2016) Efficacy of diode laser and Gluma on post-preparation sensitivity: a randomized split-mouth clinical study. J Esthet Restor Dent 28(6):405–411CrossRef
22.
Zurück zum Zitat Mahmoudzadeh M, Rezaei-Soufi L, Farhadian N, Jamalian SF, Akbarzadeh M, Momeni M et al (2018) Effect of CO2 laser and fluoride varnish application on microhardness of enamel surface around orthodontic brackets. J Lasers Med Sci 9(1):43CrossRef Mahmoudzadeh M, Rezaei-Soufi L, Farhadian N, Jamalian SF, Akbarzadeh M, Momeni M et al (2018) Effect of CO2 laser and fluoride varnish application on microhardness of enamel surface around orthodontic brackets. J Lasers Med Sci 9(1):43CrossRef
23.
Zurück zum Zitat Young DA, Nový BB, Zeller GG, Hale R, Hart TC, Truelove EL et al (2015) The American dental association caries classification system for clinical practice: a report of the American dental association council on scientific affairs. J Am Dent Assoc 146(2):79–86CrossRef Young DA, Nový BB, Zeller GG, Hale R, Hart TC, Truelove EL et al (2015) The American dental association caries classification system for clinical practice: a report of the American dental association council on scientific affairs. J Am Dent Assoc 146(2):79–86CrossRef
24.
Zurück zum Zitat Matys J, Dominiak M, Flieger R (2015) Energy and power density: a key factor in lasers studies. J Clin Diagn Res 9(12):ZL01PubMedPubMedCentral Matys J, Dominiak M, Flieger R (2015) Energy and power density: a key factor in lasers studies. J Clin Diagn Res 9(12):ZL01PubMedPubMedCentral
25.
Zurück zum Zitat Naito T (2008) Postoperative sensitivity in posterior composite restorations is relevant in class II cavities. J Evid Based Dent Pract 8(4):225–226CrossRef Naito T (2008) Postoperative sensitivity in posterior composite restorations is relevant in class II cavities. J Evid Based Dent Pract 8(4):225–226CrossRef
26.
Zurück zum Zitat Sabbagh J, McConnell R, McConnell MC (2017) Posterior composites: update on cavities and filling techniques. J Dent 57:86–90CrossRef Sabbagh J, McConnell R, McConnell MC (2017) Posterior composites: update on cavities and filling techniques. J Dent 57:86–90CrossRef
27.
Zurück zum Zitat Parker S (2007) Verifiable CPD paper: Low-level laser use in dentistry. Br Dent J 202(3):131–138CrossRef Parker S (2007) Verifiable CPD paper: Low-level laser use in dentistry. Br Dent J 202(3):131–138CrossRef
28.
Zurück zum Zitat Kimura Y, Wilder-Smith P, Yonaga K, Matsumoto K (2000) Treatment of dentine hypersensitivity by lasers: a review. J Clin Periodontol 27(10):715–721CrossRef Kimura Y, Wilder-Smith P, Yonaga K, Matsumoto K (2000) Treatment of dentine hypersensitivity by lasers: a review. J Clin Periodontol 27(10):715–721CrossRef
29.
Zurück zum Zitat Sgolastra F, Petrucci A, Gatto R, Monaco A (2011) Effectiveness of laser in dentinal hypersensitivity treatment: a systematic review. J Endod 37(3):297–303CrossRef Sgolastra F, Petrucci A, Gatto R, Monaco A (2011) Effectiveness of laser in dentinal hypersensitivity treatment: a systematic review. J Endod 37(3):297–303CrossRef
30.
Zurück zum Zitat Schroeder M, Correa IC, Bauer J, Loguercio AD, Reis A (2017) Influence of adhesive strategy on clinical parameters in cervical restorations: a systematic review and meta-analysis. J Dent 62:36–53CrossRef Schroeder M, Correa IC, Bauer J, Loguercio AD, Reis A (2017) Influence of adhesive strategy on clinical parameters in cervical restorations: a systematic review and meta-analysis. J Dent 62:36–53CrossRef
31.
Zurück zum Zitat Sancakli HS, Yildiz E, Bayrak I, Ozel S (2014) Effect of different adhesive strategies on the post-operative sensitivity of class I composite restorations. Eur J Dent 8(1):15CrossRef Sancakli HS, Yildiz E, Bayrak I, Ozel S (2014) Effect of different adhesive strategies on the post-operative sensitivity of class I composite restorations. Eur J Dent 8(1):15CrossRef
32.
Zurück zum Zitat Pinna R, Bortone A, Sotgiu G, Dore S, Usai P, Milia E (2015) Clinical evaluation of the efficacy of one self-adhesive composite in dental hypersensitivity. Clin Oral Investig 19(7):1663–1672CrossRef Pinna R, Bortone A, Sotgiu G, Dore S, Usai P, Milia E (2015) Clinical evaluation of the efficacy of one self-adhesive composite in dental hypersensitivity. Clin Oral Investig 19(7):1663–1672CrossRef
33.
Zurück zum Zitat Ladalardo TCCGP, Pinheiro A, Campos RAC, Brugnera Júnior A, Zanin F, Albernaz PLM et al (2004) Laser therapy in the treatment of dentine hypersensitivity. Braz Dent J 15(2):144–150CrossRef Ladalardo TCCGP, Pinheiro A, Campos RAC, Brugnera Júnior A, Zanin F, Albernaz PLM et al (2004) Laser therapy in the treatment of dentine hypersensitivity. Braz Dent J 15(2):144–150CrossRef
34.
Zurück zum Zitat Fischer C, Fischer R, Wennberg A (1992) Prevalence and distribution of cervical dentine hypersensitivity in a population in Rio de Janeiro. Brazil J Dent 20(5):272–276PubMed Fischer C, Fischer R, Wennberg A (1992) Prevalence and distribution of cervical dentine hypersensitivity in a population in Rio de Janeiro. Brazil J Dent 20(5):272–276PubMed
35.
Zurück zum Zitat Ostrom C, Bair E, Maixner W, Dubner R, Fillingim RB, Ohrbach R (2017) Demographic predictors of pain sensitivity: results from the OPPERA study. J Pain 3:295–307CrossRef Ostrom C, Bair E, Maixner W, Dubner R, Fillingim RB, Ohrbach R (2017) Demographic predictors of pain sensitivity: results from the OPPERA study. J Pain 3:295–307CrossRef
36.
Zurück zum Zitat Lopes LPB, Herkrath FJ, Vianna ECB, Júnior ECG, Marques AAF, Júnior ECS (2019) Effect of photobiomodulation therapy on postoperative pain after endodontic treatment: a randomized, controlled, clinical study. Clin Oral Investig 23(1):285–292CrossRef Lopes LPB, Herkrath FJ, Vianna ECB, Júnior ECG, Marques AAF, Júnior ECS (2019) Effect of photobiomodulation therapy on postoperative pain after endodontic treatment: a randomized, controlled, clinical study. Clin Oral Investig 23(1):285–292CrossRef
37.
Zurück zum Zitat Akpata ES, Behbehani J (2006) Effect of bonding systems on post-operative sensitivity from posterior composites. Am J Dent 19(3):151–154PubMed Akpata ES, Behbehani J (2006) Effect of bonding systems on post-operative sensitivity from posterior composites. Am J Dent 19(3):151–154PubMed
38.
Zurück zum Zitat Yousaf A, Aman N, Manzoor MA, Shah J (2014) Postoperative sensitivity of self etch versus total etch adhesive. J Coll of Physicians Surg Pak 24(6):383–386 Yousaf A, Aman N, Manzoor MA, Shah J (2014) Postoperative sensitivity of self etch versus total etch adhesive. J Coll of Physicians Surg Pak 24(6):383–386
39.
Zurück zum Zitat Scotti N, Bergantin E, Giovannini R, Delbosco L, Breschi L, Migliaretti G et al (2015) Influence of multi-step etch-and-rinse versus self-etch adhesive systems on the post-operative sensitivity in medium-depth carious lesions: an in vivo study. Am J Dent 28:214–218PubMed Scotti N, Bergantin E, Giovannini R, Delbosco L, Breschi L, Migliaretti G et al (2015) Influence of multi-step etch-and-rinse versus self-etch adhesive systems on the post-operative sensitivity in medium-depth carious lesions: an in vivo study. Am J Dent 28:214–218PubMed
40.
Zurück zum Zitat Çakır NN, Demirbuga S The effect of five different universal adhesives on the clinical success of class I restorations: 24-month clinical follow-up. Clin Oral Investig 23(6):2767–2776 Çakır NN, Demirbuga S The effect of five different universal adhesives on the clinical success of class I restorations: 24-month clinical follow-up. Clin Oral Investig 23(6):2767–2776
41.
Zurück zum Zitat Carvalho AA, Leite MM, Zago JKM, Nunes CABCM, Barata TJE, de Freitas GC et al (2019) Influence of different application protocols of universal adhesive system on the clinical behavior of class I and II restorations of composite resin–a randomized and double-blind controlled clinical trial. BMC Oral Health 19(1):252CrossRef Carvalho AA, Leite MM, Zago JKM, Nunes CABCM, Barata TJE, de Freitas GC et al (2019) Influence of different application protocols of universal adhesive system on the clinical behavior of class I and II restorations of composite resin–a randomized and double-blind controlled clinical trial. BMC Oral Health 19(1):252CrossRef
42.
Zurück zum Zitat Mittal R, Singla MG, Sood A, Dua A, Sodhi PS (2014) Clinical evaluation of middle power output 810 nm GaAIAs diode laser for treating severe dentin hypersensitivity: a randomized clinical trial. Int J Laser Dent 4(1):20–25CrossRef Mittal R, Singla MG, Sood A, Dua A, Sodhi PS (2014) Clinical evaluation of middle power output 810 nm GaAIAs diode laser for treating severe dentin hypersensitivity: a randomized clinical trial. Int J Laser Dent 4(1):20–25CrossRef
Metadaten
Titel
Effect of 940 nm laser diode irradiation prior to bonding procedure on postoperative sensitivity following class II composite restorations: a split-mouth randomized clinical trial
verfasst von
Loghman Rezaei-Soufi
Mojgan Taheri
Reza Fekrazadas
Maryam Farhadian
Publikationsdatum
03.01.2021
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 5/2021
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-020-03213-w

Weitere Artikel der Ausgabe 5/2021

Lasers in Medical Science 5/2021 Zur Ausgabe