Skip to main content
Erschienen in: General Thoracic and Cardiovascular Surgery 9/2020

01.09.2020 | Original Article

Hemodynamic performance and incidence of patient–prosthesis mismatch of small-sized Trifecta pericardial aortic valves

verfasst von: Susumu Manabe, Ryoji Koinoshita, Daiki Hirayama, Norihisa Yuge, Kazunobu Hirooka

Erschienen in: General Thoracic and Cardiovascular Surgery | Ausgabe 9/2020

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Small-sized bioprosthetic valves are sometimes associated with suboptimal hemodynamic performance, leading to a patient–prosthesis mismatch. Trifecta pericardial valves are designed to improve hemodynamic performance. The purpose of this study was to investigate the hemodynamic properties of small-sized Trifecta valves and their efficacy in preventing a patient–prosthesis mismatch.

Methods

This was a retrospective analysis of 108 patients undergoing surgical aortic valve replacement with a Trifecta valve of 23 mm or less in a single Japanese institution. The hemodynamic performance was evaluated with an echocardiography examination in all patients after surgery, and the development of a patient–prosthesis mismatch was judged with the measured in vivo indexed effective orifice area.

Results

There was one early and seven late mortalities. There were no valve explants due to structural valve deterioration. Postoperative mean pressure gradients of 19-, 21-, and 23-mm valves were 15.1, 11.4, and 9.0 mmHg, respectively. The effective orifice area of 19-, 21-, and 23-mm valves was 1.41, 1.69, and 1.78 cm2, respectively. Patient–prosthesis mismatch occurred in 14 patients (1 severe and 13 moderate) and the incidence was 13.0% (15.4% in 19 mm, 18.0% in 21 mm, and 3.3% in 23 mm).

Conclusions

The small-sized Trifecta valves showed excellent hemodynamic performance and were associated with a low incidence rate of patient–prosthesis mismatch.
Literatur
1.
Zurück zum Zitat Koyama T, Okura H, Kume T, Fukuhara K, Imai K, Hayashida A, et al. Impact of energy loss index on left ventricular mass regression after aortic valve replacement. J Echocardiogr. 2014;12:51–8.CrossRef Koyama T, Okura H, Kume T, Fukuhara K, Imai K, Hayashida A, et al. Impact of energy loss index on left ventricular mass regression after aortic valve replacement. J Echocardiogr. 2014;12:51–8.CrossRef
2.
Zurück zum Zitat Ali A, Patel A, Ali Z, Abu-Omar Y, Saeed A, Athanasiou T, et al. Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival. J Thorac Cardiovasc Surg. 2011;142:285–91.CrossRef Ali A, Patel A, Ali Z, Abu-Omar Y, Saeed A, Athanasiou T, et al. Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival. J Thorac Cardiovasc Surg. 2011;142:285–91.CrossRef
3.
Zurück zum Zitat Fallon JM, DeSimone JP, Brennan JM, O’Brien S, Thibault DP, DiScipio AW, et al. The incidence and consequence of prosthesis-patient mismatch after surgical aortic valve replacement. Ann Thorac Surg. 2018;106:14–23.CrossRef Fallon JM, DeSimone JP, Brennan JM, O’Brien S, Thibault DP, DiScipio AW, et al. The incidence and consequence of prosthesis-patient mismatch after surgical aortic valve replacement. Ann Thorac Surg. 2018;106:14–23.CrossRef
4.
Zurück zum Zitat Sá MPBDO, de Carvalho MMB, Sobral Filho DC, Cavalcanti LRP, Rayol SDC, Diniz RGS, et al. Surgical aortic valve replacement and patient–prosthesis mismatch: a meta-analysis of 108182 patients. Eur J Cardiothorac Surg. 2019;56:44–54.CrossRef Sá MPBDO, de Carvalho MMB, Sobral Filho DC, Cavalcanti LRP, Rayol SDC, Diniz RGS, et al. Surgical aortic valve replacement and patient–prosthesis mismatch: a meta-analysis of 108182 patients. Eur J Cardiothorac Surg. 2019;56:44–54.CrossRef
5.
Zurück zum Zitat Freitas-Ferraz AB, Tirado-Conte G, Dagenais F, Ruel M, Al-Atassi T, Dumont E, et al. Aortic stenosis and small aortic annulus. Circulation. 2019;139:2685–702.CrossRef Freitas-Ferraz AB, Tirado-Conte G, Dagenais F, Ruel M, Al-Atassi T, Dumont E, et al. Aortic stenosis and small aortic annulus. Circulation. 2019;139:2685–702.CrossRef
6.
Zurück zum Zitat Yanagawa B, Tam DY, Hong K, Mazine A, Bagai A, Shahbaz NK, et al. Magna ease versus trifecta early hemodynamics: a systematic review and meta-analysis. Innovation. 2018;13:167–272. Yanagawa B, Tam DY, Hong K, Mazine A, Bagai A, Shahbaz NK, et al. Magna ease versus trifecta early hemodynamics: a systematic review and meta-analysis. Innovation. 2018;13:167–272.
7.
Zurück zum Zitat Colli A, Marchetto G, Salizzoni S, Rinaldi M, Di Marco L, Pacini D, et al. The TRIBECA study: (TRI)fecta (B)ioprosthesis (E)valuation versus (C)arpentier Magna-Ease in (A)ortic position. Eur J Cardiothorac Surg. 2016;49:478–85.CrossRef Colli A, Marchetto G, Salizzoni S, Rinaldi M, Di Marco L, Pacini D, et al. The TRIBECA study: (TRI)fecta (B)ioprosthesis (E)valuation versus (C)arpentier Magna-Ease in (A)ortic position. Eur J Cardiothorac Surg. 2016;49:478–85.CrossRef
8.
Zurück zum Zitat Braathen B, Husebye T, Lunde I, Tønnessen T. Trifecta has lower gradient and less prosthesis-patient mismatch than mosaic ultra in the aortic position: a prospective randomized study. J Thorac Cardiovasc Surg. 2019;158:1032–9.CrossRef Braathen B, Husebye T, Lunde I, Tønnessen T. Trifecta has lower gradient and less prosthesis-patient mismatch than mosaic ultra in the aortic position: a prospective randomized study. J Thorac Cardiovasc Surg. 2019;158:1032–9.CrossRef
9.
Zurück zum Zitat Yadlapati A, Diep J, Barnes M, Grogan T, Bethencourt DM, Vorobiof G, et al. Comprehensive hemodynamic comparison and frequency of patient-prosthesis mismatch between the St. Jude Medical Trifecta and Epic bioprosthetic aortic valves. J Am Soc Echocardiogr. 2014;27:581–9.CrossRef Yadlapati A, Diep J, Barnes M, Grogan T, Bethencourt DM, Vorobiof G, et al. Comprehensive hemodynamic comparison and frequency of patient-prosthesis mismatch between the St. Jude Medical Trifecta and Epic bioprosthetic aortic valves. J Am Soc Echocardiogr. 2014;27:581–9.CrossRef
10.
Zurück zum Zitat Domoto S, Niinami H, Uwabe K, Koike H, Tabata M, Morita K, et al. Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulus. Interact Cardiovasc Thorac Surg. 2016;22:19–25.CrossRef Domoto S, Niinami H, Uwabe K, Koike H, Tabata M, Morita K, et al. Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulus. Interact Cardiovasc Thorac Surg. 2016;22:19–25.CrossRef
11.
Zurück zum Zitat Goldman S, Cheng A, Bavaria JE, Petracek MR, Groh MA, Schaff HV. Midterm, multicenter clinical and hemodynamic results for the Trifecta aortic pericardial valve. J Thorac Cardiovasc Surg. 2017;153:561–9.CrossRef Goldman S, Cheng A, Bavaria JE, Petracek MR, Groh MA, Schaff HV. Midterm, multicenter clinical and hemodynamic results for the Trifecta aortic pericardial valve. J Thorac Cardiovasc Surg. 2017;153:561–9.CrossRef
12.
Zurück zum Zitat Phan K, Phan S, Misfeld M, Eusanio MD, Yan TD. Early hemodynamic performance of the third generation St Jude Trifecta aortic prosthesis: a systematic review and meta-analysis. J Thorac Cardiovasc Surg. 2015;149:1567–75.CrossRef Phan K, Phan S, Misfeld M, Eusanio MD, Yan TD. Early hemodynamic performance of the third generation St Jude Trifecta aortic prosthesis: a systematic review and meta-analysis. J Thorac Cardiovasc Surg. 2015;149:1567–75.CrossRef
13.
Zurück zum Zitat Capodanno D, Petronio AS, Prendergast B, Eltchaninoff H, Vahanian A, Modine T, et al. Standardized definitions of structural deterioration and valve failure in assessing long-term durability of transcatheter and surgical aortic bioprosthetic valves: a consensus statement from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) endorsed by the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg. 2017;52:408–17.CrossRef Capodanno D, Petronio AS, Prendergast B, Eltchaninoff H, Vahanian A, Modine T, et al. Standardized definitions of structural deterioration and valve failure in assessing long-term durability of transcatheter and surgical aortic bioprosthetic valves: a consensus statement from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) endorsed by the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg. 2017;52:408–17.CrossRef
14.
Zurück zum Zitat Okamura H, Yamaguchi A, Yoshizaki T, Nagano H, Itoh S, Morita H, et al. Clinical outcomes and hemodynamics of the 19-mm perimount magna bioprosthesis in an aortic position. Circ J. 2012;76:102–8.CrossRef Okamura H, Yamaguchi A, Yoshizaki T, Nagano H, Itoh S, Morita H, et al. Clinical outcomes and hemodynamics of the 19-mm perimount magna bioprosthesis in an aortic position. Circ J. 2012;76:102–8.CrossRef
15.
Zurück zum Zitat Tadokoro N, Fukushima S, Shimahara Y, Matsumoto Y, Yamashita K, et al. Trifecta vs. Magna for aortic valve replacement. Differences in clinical outcome and valve hemodynamics. Circ J. 2018;82:2767–75.CrossRef Tadokoro N, Fukushima S, Shimahara Y, Matsumoto Y, Yamashita K, et al. Trifecta vs. Magna for aortic valve replacement. Differences in clinical outcome and valve hemodynamics. Circ J. 2018;82:2767–75.CrossRef
16.
Zurück zum Zitat Pinon M, Duran D, Pazos P, Pradas G. Leaflet tear in a Trifecta aortic bioprosthesis 34 months after implantation. Interact Cardiovasc Thorac Surg. 2015;20:281–2.CrossRef Pinon M, Duran D, Pazos P, Pradas G. Leaflet tear in a Trifecta aortic bioprosthesis 34 months after implantation. Interact Cardiovasc Thorac Surg. 2015;20:281–2.CrossRef
Metadaten
Titel
Hemodynamic performance and incidence of patient–prosthesis mismatch of small-sized Trifecta pericardial aortic valves
verfasst von
Susumu Manabe
Ryoji Koinoshita
Daiki Hirayama
Norihisa Yuge
Kazunobu Hirooka
Publikationsdatum
01.09.2020
Verlag
Springer Singapore
Erschienen in
General Thoracic and Cardiovascular Surgery / Ausgabe 9/2020
Print ISSN: 1863-6705
Elektronische ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-019-01284-3

Weitere Artikel der Ausgabe 9/2020

General Thoracic and Cardiovascular Surgery 9/2020 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.