Skip to main content
Erschienen in: BMC Health Services Research 1/2022

Open Access 01.12.2022 | Research

Improving peripheral venous cannula insertion in children: a mixed methods study to develop the DIVA key

verfasst von: Jessica A. Schults, Tricia M. Kleidon, Victoria Gibson, Robert S. Ware, Emily Monteagle, Rebecca Paterson, Karina Charles, Adam Keys, Craig A. McBride, Steven McTaggart, Benjamin Lawton, Fiona Macfarlane, Chloe Sells, Claire M. Rickard, Amanda J. Ullman

Erschienen in: BMC Health Services Research | Ausgabe 1/2022

Abstract

Objective

To develop and validate a difficult intravenous access risk assessment and escalation pathway, to increase first time intravenous insertion success in paediatrics.

Methods

Mixed methods underpinned by literature and co-production principles. Iterative development of the instrument was informed through semi-structured interviews and stakeholder workshops. The instrument includes a risk assessment, inserter skill self-assessment, and escalation pathways. Reproducibility, reliability, and acceptability were evaluated in a prospective cohort study at a quaternary paediatric hospital in Australia.

Results

Interview data (three parents, nine clinicians) uncovered two themes: i) Recognition of children with DIVA and subsequent escalation is ad hoc and problematic; and ii) Resources and training impact inserter confidence and ability. Three workshops were delivered at monthly intervals (February–April 2020) involving 21 stakeholders culminating in the co-production of the “DIVA Key”. The DIVA Key was evaluated between May–December 2020 in 78 children; 156 clinicians. Seventy-eight paired assessments were undertaken with substantial agreement (concordance range = 81.5 to 83.0%) between the assessors. Interrater reliability of the DIVA risk assessment was moderate (kappa = 0.71, 95% CI 0.63–0.80). The DIVA Key predicted multiple insertion attempts for red (high risk) DIVA classification (relative risk ratio 5.7, 95% CI 1.2–27.1; reference low risk). Consumer and clinician satisfaction with DIVA Key was high (median (IQR) = 10 [8–10]; 8 [8–10 respectively).

Conclusion

The DIVA Key is a straightforward, reliable instrument with inbuilt escalation pathway to support the identification of children with difficult intravenous access.
Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1186/​s12913-022-07605-2.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Insertion of a peripheral intravenous catheter (PIVC) is almost synonymous with hospitalisation [1, 2]. As a vascular access device, it is minimally invasive and facilitates immediate medical treatment. However, most children and their families describe insertion of a PIVC to be one of the most painful and stressful procedures during their hospitalisation [3]. Up to 69% of first attempt insertions fail [46], leading to delays to medical treatment and extended inpatient days [7, 8]. For health services, PIVC insertion failure contributes to significant usage and wastage of healthcare resources, costing the Australian health care system nearly $450 million [AUD] annually [9].
More than 50% of children are conservatively estimated to have difficult intravenous access (DIVA) [5, 10, 11]. DIVA is characterised by nonvisible and non-palpable veins; which may be due to physiology, pathology, or previous PIVC damage; making PIVC insertion ‘difficult’ for most clinicians [6]. The ‘average’ PIVC insertion requires two attempts and 20–30 min [12]. For children with DIVA, successful PIVC insertion may require upwards of nine attempts (needle sticks) [5]. Historically, DIVA status is retrospectively assigned after the patient has endured multiple failed PIVC insertion attempts. As a result, there has been a recent surge in the development of DIVA decision-making resources for paediatric patients [13]. Processes to identify children with DIVA have been attempted, primarily within emergency departments [14] with the development of three [11], four [10, 11, 15] and five variable DIVA Scores [16]; a Peripheral Venous Grading System [17] and a Peripheral Vein Assessment Instrument [18]. While many have been based on sizeable cohorts, their clinical generalisability in general hospital wards can be limited [10, 11, 15]. Furthermore, they are i) limited in their capacity to direct clinicians on how to manage these ‘DIVA’ patients once identified; and ii) typically do not feature consumer engagement, or patient centred principles such as procedural pain, or skill and confidence of the inserter. Together with input from key clinical stakeholders and pediatric consumers, we sought to develop a DIVA identification and escalation instrument (the DIVA Key) to support clinical practice. The reliability, reproducibility, and acceptability of the DIVA Key, as a strategy to identify children with DIVA, was then evaluated to assess clinical utility and application feasibility in paediatric settings.

Methods

A sequential, mixed methods study was undertaken at the Queensland Children’s Hospital (QCH) Australia, a quaternary paediatric hospital, between February and December 2020. Study design was underpinned by the Co-production and Prototyping framework for Public Health Interventions [19]. Ethical approval was obtained from Children’s Health Queensland Human Research Ethics Committee (LNR/19/QCHQ/55326) and Griffith University (2019/797). The study is reported in line with The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement [20] and informed by the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist [21].

Phase 1: DIVA key co-production

Aim

To co-produce an instrument to identify and escalate insertion procedures for children with DIVA.

Research questions

1.
What are the current experiences of key stakeholders regarding DIVA?
 
2.
What are the instrument requirements based on stakeholders’ views?
 

Stakeholder mapping and recruitment

We identified and invited a cross-section of multidisciplinary stakeholders, including physicians, vascular access specialists, nurses, educators, quality and safety experts, hospital executives and consumer representatives to attend interviews and advisory group workshops via email invitation and expressions of interests (facilitated through QCH Family Advisory Council). Relevant multidisciplinary stakeholders were clinicians actively involved in vascular access with an interest in the development of policy and instruments related to identifying patients with DIVA across the health service. Where specific stakeholders were unable to attend, we employed snowballing techniques to recruit other relevant stakeholders. This approach provided a broad skill-set and perspective in the process of co-producing the instrument.

Semi-structured interviews

Semi-structured interviews were conducted to understand stakeholders’ current views and previous experiences with children with DIVA and related policy. Interviews utilised an interview guide and were conducted until data saturation was achieved, determined through the use of field notes [22, 23]. This activity facilitated evidence gathering of the current circumstances to be used as testimonials during the workshops [24].
Qualitative data obtained from interviews were analysed using iterative and inductive thematic analysis [23], per Braun and Clarke’s six phases of thematic analysis [23]. Initially two researchers (KC, JS) read transcribed interviews, independently generating initial codes. An audit trail was used to enhance dependability [25]. Codes were collated into potential themes. Themes were reviewed by both researchers in relation to coded extracts and a thematic map generated. To ensure authenticity resulting themes were reviewed by a third team member (VG).

Workshop design

Workshop design (n = 3) was informed by Carney/Oliver co-production principles [24, 26, 27]. Workshops were carefully planned using a scripted approach (example Supplementary material 1) and focused on joint decision-making between the research team, stakeholders, and consumers [28]. Workshop participants were provided an evidence summary (literature review findings [13]), excerpts from interview texts summarising desired instrument requirements, and an overview of current local DIVA policy. Expert opinion was an important consideration for co-production of instrument inclusions, with clinician gestalt linked with DIVA status prediction and first attempt insertion failure [29].

Evaluation of instrument reproducibility, reliability, utility and acceptability

Reproducibility, reliability, utility, and acceptability of the instrument was evaluated using a prospective cohort study in the medical and surgical wards and operating theatres at QCH with the following objectives:
1.
To evaluate the degree of agreement between inserters using the paediatric DIVA instrument (peripheral vein assessment instrument);
 
2.
To evaluate the validity reliability of the paediatric DIVA instrument (peripheral vein assessment instrument);
 
3.
To evaluate the reliability of the paediatric DIVA instrument (peripheral vein assessment instrument);
 
4.
Describe the utility of the DIVA escalation pathway;
 
5.
Determine clinician and consumer acceptability of the DIVA instrument;
 
6.
To determine the performance of the DIVA instrument.
 
Staff resourcing and existing model of care prevented testing of the reliability and impact of the escalation component of the DIVA Key.

Sample and participants

A stratified, purposeful sample [30] of 78 children were recruited across the ages of: neonates (≤1 month) (n = 10), 1 month–2 years (n = 17), 2–5 years, 5–10 years (n = 17), and 10–18 years (n = 17). Children were eligible for study inclusion if they required the insertion of a PIVC. We excluded children requiring an emergent PIVC insertion, PIVC insertions outside hospital settings, children under the care of the Department of Social Services, and children from non-English speaking families without access to an interpreter.

Measurements

Study measures are outlined in Table 1.
Table 1
Measures and timeframes
Construct
Measure
Source
Time point
   
0
1
2
3
Face validity(33)
Five cliniciansb rated how well the instrument appeared to support PIVC insertion and DIVA recognition using a 5-point Likert scale 1 (strongly disagree) - 5 (strongly agree).
Cl
a
   
Content validity [31, 32]
Five experts examined the DIVA Key’s content validity using measures of relevancy, clarity, and simplicity for each item.
Cl
a
   
Agreement [33]
Interrater agreement of the instrument was assessed using percentage concordance (agreement parameter) between the assessors.
CRF
 
a
  
Reliability [34]
Instrument reliability of the DIVA Key was assessed using Kappa.
CRF
 
a
  
Consumer acceptability
Consumers (patient if > 8 years and/or parent representative) will be asked to rate their satisfaction with the DIVA instrument and escalation pathway (2 measures) using an 11-point numerical scale (0–10).
P, C
  
a
 
Clinician acceptability
The inserter (clinician) will be asked to rate their satisfaction with the DIVA Key (peripheral vein assessment instrument and escalation pathway) using an 11-point numerical scale (0–10) and filed notes.
Cl
  
a
 
Utility
PIVC insertions that are referred to an advanced practitioner that go on to be inserted by an advanced practitioner.
CRF
  
a
 
 
PIVC insertions requiring USG that receive USG technology
CRF
  
a
 
Performance
First time insertion success: The number of PIVCs successfully inserted on first needle puncture as evidenced by blood flashback and ability to infuse 2-10 mL (age appropriate) 0.9% sodium chloride without signs of swelling or pain at the insertion site [18, 35, 36].
CRF
  
a
 
 
Total number of PIVC insertion attempts (skin punctures) to successfully insert PIVC [36].
CRF
  
a
 
 
PIVC failure prior to the completion of therapy, per 1000 catheter days [37].
iEMR
   
a
CRF Case report form, iEMR Integrated electronic medical records, P Parent reported measure, C Child reported measure, Cl Clinician, Time point 0 Instrument development, Time point 1 At point of identification of indication for PIVC, Time point 2 Post PIVC insertion; Time point 3 PIVC removal or failure. DIVA Difficult intravenous access, PIVC Peripheral intravenous catheter; USG Ultrasound guidance
aMeasure administered at this time point
bTwo doctors, three nurses

Study procedures

Patients who met eligibility criteria were approached for informed consent by the clinical research nurse (CRN). Peripheral vein assessments were then consecutively performed by two clinicians experienced in paediatric PIVC insertion. The order of the assessments was random, and successive, with assessors masked to the outcome of the previous assessment. Each patient’s ‘risk’ level on the vein assessment instrument was then referenced against the escalation pathway and the decision to comply with its recommendation was based on the inserter’s preference. Following PIVC insertion, the CRN assessed staff and consumer satisfaction with the instrument and overall PIVC insertion.

Sample size

We assumed the true concordance rate was 75%, and therefore to estimate the percentage concordance to within +/− 10%, with alpha = 0.05, a sample of 76 participants was needed. To ensure equal split among groups, however, the target sample size was set at 78.

Data collection and management

A screening log recorded patient information including name, unique hospital identifier (UR), eligibility and recruitment. Demographic and clinical data including age, gender, diagnosis, instrument assessment and recommendation were recorded on the case report form by the CRN and entered into an electronic data platform, REDCap™ (Research Electronic Data Capture) [38, 39].

Statistical analysis

Patient and clinical variables, and staff and consumer satisfaction ratings, were summarised using descriptive statistics. Mean and standard deviation were used for normally distributed data, and median and interquartile range for data not normally distributed [31]. Counts and percentages were used to summarise instrument and pathway utility and feasibility. A mixed-effect logistic regression was used to analyse how often different clinicians reach the same response for each pair (insert or refer). Percentage concordance is a standard measure of the predictive accuracy in a logistic regression model. Reliability of the escalation pathway was analysed using kappa coefficients and 95% confidence intervals. Predictability of first insertion success by DIVA status was analysed using a multinomial logistic regression model.

Results

Phase 1: co-production of DIVA key

Semi structured interviews, gathering evidence of current practice

In total 12 stakeholders (three consumer representatives and nine clinicians) participated in semi-structured interviews. Analysis of interview data revealed two main themes which described the current clinical landscape: i) Recognition of children with DIVA and subsequent escalation is ad hoc and problematic; and ii) Resources and training impact inserter confidence and ability. Supplementary material 2 outlines the thematic map, supportive evidence and key principles and recommendations. These recommendations were used in conjunction with the literature review findings to support the co-production workshops.

Co-production of the DIVA key

Three workshops were delivered at monthly intervals (February 2020 to April 2020). Overall, 21 stakeholders participated in the workshops, of which nine attended two or more workshops. Stakeholders represented local and regional perspectives across Queensland Health, Academia and Educational organisations. By workshop two, stakeholders had co-produced a prototype of a paediatric DIVA vein assessment instrument and escalation pathway. Instruments were refined and finalised for testing in workshop three. Informal feedback received post workshops revealed stakeholders perceived their contribution as valuable to ensure the components of the instrument were user-friendly and relevant to the health service,
It was great to be able to contribute my knowledge of procedural anxiety to the instruments development.’ (M3), and.
The traffic light system was a good addition to the instrument layout and I was impressed they took my suggestions onboard and included it in the final instrument.’ (M9).
The resulting instrument, entitled the DIVA Key is presented in Fig. 1 (visual concept created by @doubler.design). The instrument includes: i) DIVA risk assessment based on known DIVA risk factors [4, 15, 32, 33]; ii) inserter self-assessment of skill [34]; and iii) an escalation pathway [18]. A colour coded, traffic light system relative to risk (e.g., high risk of DIVA = Red) was used in addition to paediatric friendly graphics and logical flow to support decision making. Additional prompts for pain management and anxiety are included [35]. An outcome of the co-production process was that the instrument was tailored to the local health setting by including local policy references and contact details.
  • Insert Fig. 1. DIVA Key

Phase 2: evaluation of the DIVA key

Validity

Face validity of the instrument was demonstrated with a median rating of 4.5 (IQR 3–5) for clarity and relevance across five assessors (multidisciplinary clinicians who did not participate in the co-production workshops). The content validity of the DIVA Key resulted in all items scoring > 3 for clarity and feasibility using a 4-point level of agreement (1, not; 2, somewhat; 3, quite; 4, highly) [36, 37]. Revisions to flow, item wording, and the addition of more elements were proposed (e.g., traffic light system and procedural pain advice). The DIVA Key was subsequently amended to support the proposed modifications. Item validity was determined using a content validity index (I-CVI) [36, 37]. A panel of experts (n = 4) comprising multidisciplinary paediatric vascular access specialists were asked to provide feedback on the appropriateness and relevance of survey items using a four-point level of agreement (1, not; 2, somewhat; 3, quite; 4, highly). I-CVIs were calculated as the number of experts giving a score of 3 or 4 (item cut-off score of 0.75). Briefly, I-CVI for the DIVA Key ranged from 0.75 to 1.0. Overall, 20 out of 24 items in the DIVA Key had an I-CVI of 1.00, demonstrating moderate agreement among the content experts.

Reproducibility, reliability, utility and acceptability

In the prospective cohort study, 78 children were recruited between May and December 2020 with no refusals or loss to follow up. The sample characteristics are outlined in Table 2.
Table 2
Sample characteristics
Variable
Participants (n = 78)
Age, median (IQR), years
2.5 (0.4–9.0)
Male, n (%)
45 (58%)
Weight, median (IQR), kg
14.0 (7.0–31.0)
General appearance, adiposity, n (%)
 Minimal
28 (36%)
 Moderate
33 (42%)
 Excessive
17 (22%)
History of prematurity, n (%)
 No
70 (90%)
 Yes
8 (10%)
Primary diagnosis, n (%)
 Medical
60 (77%)
 Surgical
15 (19%)
 Other
3 (4%)
Location of insertion, n (%)
 Medical ward
39 (50%)
 Operating room
15 (19%)
 Babies ward
10 (13%)
 Surgical ward
8 (10%)
 Othera
6 (8%)
Device inserted for, n (%)
 Treatment (e.g., antibiotics)
47 (60%)
 Replacement device
17 (22%)
 Other
14 (18%)
IQR Interquartile Range, kg Kilograms; Mons months, Yrs Years
aincludes intensive care admissions

Agreement and reliability

Agreement of the 78 paired DIVA Key assessments was undertaken (individual assessors were blinded to the other assessment) with substantial concordance (range 81.5 to 83.0%) between assessors across low, medium, and high-risk groups (Table 3). Interrater reliability of the DIVA risk assessment (DIVA classification) was 0.71 (Kappa, 95% CI 0.63–0.80; p = < 0.001) suggesting moderate agreement. Interrater reliability of the DIVA Key recommendation for management was moderate 0.65 (0.57 to 0.72).
Table 3
Concordance of overall DIVA risk assessment by Clinician 1 and Clinician 2
First Assessor
Second Assessor
Low-risk
Medium- risk
High-risk
Specific Agreement (of DIVA risk assessment)
Low-risk
22
6
0
83.0% (72.1 to 93.9%)
Medium-risk
3
31
5
81.6% (72.1 to 91.1%)
High-risk
0
0
11
81.5% (65.5 to 97.4%)
When the DIVA Key identified a child as being medium risk, then the relative risk ratio (RRR) of having multiple insertion attempts, compared to if they were identified as low risk, increased by 6.2 (95% CI 1.6–24.5; p = 0.009). If the child was identified as high risk, compared to low risk, then the relative risk of having multiple insertion attempts was increased by a similar magnitude (RRR 5.7, 95% CI 1.2–27.1; p = 0.03).

Acceptability

Consumer and clinician satisfaction with the DIVA Key was high. The median consumer satisfaction score was 10/10 (IQR 8–10). Clinicians reported a median satisfaction score of 8/10 (IQR 8–10) noting ‘People might over-rate confidence.’ and ‘More information needed around who makes the first attempt.’.

Instrument performance and utility

PIVC insertion characteristics and outcomes, by DIVA risk are outlined in Table 4. First attempt insertion success (46%) was lowest in children assessed as high risk (red) and highest in children classified as low risk (82%). The median number of insertion attempts in the high risk group was 2 (IQR 1–5) compared to 1 in the low and medium risk groups (IQRs 1–1 and 1–3 respectively). Insertion difficulty was rated highest in children classified as high risk (5/10, IQR 3–7). All children (n = 11) identified as high risk of DIVA had their PIVC successfully inserted by an advanced inserter (self-capability assessment RED). Of the 11 children, 90% (n = 10) of insertions utilised ultrasound guidance. No PIVC insertions were abandoned with all children receiving an intravenous catheter for treatment.
Table 4
Comparison of PIVC insertion characteristics and outcome, by DIVA risk (assessed by treating clinician)
Variable
Low (green)
(n = 28)
Medium (Yellow)
(n = 39)
High (Red)
(n = 11)
First attempt insertion success, n (%, 95 CI)
23 (82%; 68–96)
23 (59%; 46–74)
5 (46%; 16–75)
Number of attempts, median (IQR)
1 (1–1)
1 (1–3)
2 (1–5)
First attempt bya, n (%)
 Developing inserter
6 (21)
3 (8)
0 (0)
 Confident Inserter
15 (54)
15 (38)
4 (36)
 Advanced inserter
7 (25)
21 (54)
7 (64)
Successful PIVC placed by, n (%)
 Developing inserter
6 (21)
2 (5)
0 (0)
 Confident Inserter
16 (54)
14 (36)
0 (0)
 Advanced inserter
7 (25)
23 (59)
11 (100)
 Rating of insertion difficultyb, median (IQR)
2 (1–3)
2 (1–5)c
5 (3–7)
IQR Interquartile range
aSelf-report assessment of skill; b Successful inserter scale of 1–10; c 3 missing; dday cases recruitment common

Discussion

This project co-produced and validated the DIVA Key instrument to support the assessment and subsequent escalation of PIVC insertion care in children with DIVA. Consistent with the evidence-base around DIVA risk factors and existing DIVA instruments [10, 11, 1318], the DIVA Key included objective descriptions of vessel quality (e.g., appearance) and practice variables (e.g., acuity, previous access history). These indicators were uniquely complemented by rating the child’s reported or perceived anxiety, along with the clinician’s self-assessment of ability, and recommendations for management of procedural pain and anxiety. In this study the DIVA Key demonstrated interrater reliability and agreement and was acceptable to both clinicians and families. Our findings support the instrument’s application and utility across a quaternary paediatric hospital setting.
Our prior literature review and survey of practice [13, 40] demonstrated a variability surrounding the sensitivity and useability of paediatric DIVA instruments. Whilst most tools demonstrated moderate predictive ability (DIVA Score area under the curve [AUC] 0.67 75% [15], 3-variable DIVA score AUC 0.72 [11]), clinometric testing outside of the emergency department was scarce. Further existing DIVA tools lacked decision-making cues to direct escalation, failed to consider inserter skill and confidence, and did not take into consider patient experience or preference (i.e., patient reported pain and anxiety). To overcome these obstacles, the DIVA Key was co-produced with stakeholders and consumers, and underpinned by the diverse and unique insights they provided [41]. The resulting resource, the DIVA Key, reflects the experiences of clinicians and consumers, and demonstrates promising reproducibility, utility, and acceptability. Due to the insights from stakeholders and consumers, the DIVA Key had strong face and content validity, and stakeholders qualitatively reported that they felt their feedback was incorporated into the final instrument.
PIVC insertion in patients with DIVA is challenging, even for experienced clinicians [42]. Irrespective of inserter skill, identification of DIVA risk should occur prior to subjecting a child to multiple, painful failed insertion attempts [43]. Early identification of children with DIVA relies on instruments that, even with minimal training, provide an objective and reproducible description of a child’s risk of DIVA. To achieve this, the DIVA Key employed alliteration ( [44] drawing emphasis to certain ideas) to prompt recall by users of DIVA risk factors (acuity, appearance, alerts, admissions, age, and anxiety) and a traffic-light system [45] for risk level, complemented by the clinician self-assessment (ability). As a result, there was considerable agreement among assessors of varied skill level when assessing the child’s predicted risk of DIVA, and a high level of inserter-reported satisfaction with the instrument. Additionally, the DIVA Key demonstrated high construct validity. Children who were assessed as ‘high risk’ had the lowest rate of first-attempt insertion success, slightly higher median insertion attempts, and greater perceived insertion difficulty.
Early identification of DIVA in children alone is not sufficient to improve patient outcomes. Clinicians in this study voiced concerns that they lacked the skills, training, or resources to manage patients with DIVA. This finding is consistent with earlier research highlighting the lack of support or resources available to clinicians once DIVA is identified [13]. Therefore, the DIVA Key includes a clear and concise escalation pathway (ascend), that matches patient level of risk and inserter competency, to guide the number of attempts before escalation (i.e., no more than 2 attempts prior to escalating to a more experienced clinician with or without vessel visualisation technologies). Similar to Hallam’s vessel preservation tool [18, 46].
This study has several strengths. Instrument development was grounded in a literature review, survey of practice and extensive stakeholder consultation [47, 48]. Additionally, the instrument development was underpinned by the co-production framework [19] and develop iteratively which allowed for constant adaption and improvement based on key stakeholder requirements. Despite these strengths our study is not without limitations. The development of the DIVA instrument relied heavily on clinical expertise. Although this level of evidence can be inconsistent, it was necessary to ensure the utility and acceptability of the instrument. Previous research demonstrated the complementary role of clinical ‘gestalt’ in accurate DIVA identification [29]. Finally, in this study, inserters were typically resident medical officers or registered nurses as is standard in our local setting. Insertion practices vary between institutions globally however, and interpretations of the concordance and utility of the instrument should be interpreted accordingly. The design of the current study precluded evaluation of the criterion validity of the DIVA Key, and therefore we were unable to determine the sensitivity and specificity, and corresponding positive and negative predictive values, of the DIVA Key in detecting a child’s DIVA status prior to escalation. Given the indicators of DIVA used in the DIVA Key are consistent with other highly sensitive paediatric instruments (e.g., Cornell Assessment of Pediatric Delirium [49, 50]), and the results of logistic regression found that first attempt insertion success was lowest in children assessed as high risk of DIVA, however, suggests that the DIVA Key is a promising instrument for the accurate identification of DIVA in this population.

Conclusion

We co-produced a user-friendly, consumer focussed instrument to support the identification of DIVA in children, with an inbuilt inserter escalation pathway. In this cohort the DIVA Key appears to be a reliable instrument to support the identification and management of DIVA in children. Further testing among varying cohorts is warranted to further test generalisability of this measurement instrument and determine whether the implementation of an escalation pathway improves patient outcomes.

Acknowledgements

We would like to acknowledge the contributions made by graphic designer Murray Richards @doubler.design (murray.richards@doubler.design) for making the final tool come to life. To Ms. Sharmaine Griffin, the children, families and clinicians at Queensland Children’s Hospital for supporting the study on the floor. We would also like to acknowledge the DIVA advisory group members and expert consultants who provided invaluable feedback on study processes or assessed face or content validity of the tool including, A/Professor Joshua Byrnes, Dr. Greg Maloney, Ms. Katherine Kotzur, Dr. Alexandra Donaldson, Dr. Stuart Watkins, Dr. Peter Snelling, Dr. Adam Irwin, Ms. Anita Inwood, Ms. Julieta Woosley, Ms. Melanie Kennedy, Dr. Michaela Waak, Ms. Anna Dean, Ms. Melanie Kennedy and Dr. Henry Goldstein.

Declarations

Ethical approval to conduct the study was obtained from the Children’s Health Queensland Human Research Ethics Committee (LNR/19/QCHQ/55326) and Griffith University (2019/797). Written informed consent was obtained from all study participants.

Competing interests

Jessica Schults reports grants from Becton Dickinson unrelated to the current project.
Tricia Kleidon has received grant funding from Children’s Hospital Foundation, Griffith University, National Health and Medical Research Council (NHMRC), Emergency Medicine Foundation and investigator-initiated research grants and speaker fees provided to Griffith University from vascular access product manufacturers 3 M Medical, Access Scientific, Angiodynamics, BD-Bard, Baxter, Cardinal Health, Medical Specialties Australia, Vygon.
Claire Rickard reports investigator-initiated research grants and speaker fees provided to Griffith University from vascular access product manufacturers (3 M, BD-Bard; Cardinal Health), unrelated to this project.
Amanda Ullman reports fellowships and grants by the National Health and Medical Research Council (NHMRC), employment by Griffith University, grants by the Children’s Hospital Foundation, the Royal Brisbane and Women’s Hospital Foundation, Emergency Medicine Foundation, and the Australian College of Critical Care Nursing, and investigator-initiated research grants and speaker fees provided to Griffith University from 3 M, Cardinal Health, and Becton Dickinson.
VG, RW, EM, RP, KC, AK, CM, SM, BL, FM, CS have no conflicts of interest to declare.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Anhänge
Literatur
1.
Zurück zum Zitat Ullman AJ, Takashima M, Kleidon T, Ray-Barruel G, Alexandrou E, Rickard CM. Global pediatric peripheral intravenous catheter practice and performance: a secondary analysis of 4206 catheters. J Pediatr Nurs. 2020;50:e18–25.PubMedCrossRef Ullman AJ, Takashima M, Kleidon T, Ray-Barruel G, Alexandrou E, Rickard CM. Global pediatric peripheral intravenous catheter practice and performance: a secondary analysis of 4206 catheters. J Pediatr Nurs. 2020;50:e18–25.PubMedCrossRef
2.
3.
Zurück zum Zitat Cooke M, Ullman AJ, Ray-Barruel G, Wallis M, Corley A, Rickard CM. Not "just" an intravenous line: consumer perspectives on peripheral intravenous cannulation (PIVC). An international cross-sectional survey of 25 countries. PLoS One. 2018;13(2):e0193436.PubMedPubMedCentralCrossRef Cooke M, Ullman AJ, Ray-Barruel G, Wallis M, Corley A, Rickard CM. Not "just" an intravenous line: consumer perspectives on peripheral intravenous cannulation (PIVC). An international cross-sectional survey of 25 countries. PLoS One. 2018;13(2):e0193436.PubMedPubMedCentralCrossRef
4.
Zurück zum Zitat Sabri A, Szalas J, Holmes KS, Labib L, Mussivand T. Failed attempts and improvement strategies in peripheral intravenous catheterization. Biomed Mater Eng. 2013;23(1–2):93–108.PubMed Sabri A, Szalas J, Holmes KS, Labib L, Mussivand T. Failed attempts and improvement strategies in peripheral intravenous catheterization. Biomed Mater Eng. 2013;23(1–2):93–108.PubMed
5.
Zurück zum Zitat Kleidon TM, Cattanach P, Mihala G, Ullman AJ. Implementation of a paediatric peripheral intravenous catheter care bundle: a quality improvement initiative. J Paediatr Child Health. 2019;55(10):1214-23. Kleidon TM, Cattanach P, Mihala G, Ullman AJ. Implementation of a paediatric peripheral intravenous catheter care bundle: a quality improvement initiative. J Paediatr Child Health. 2019;55(10):1214-23.
6.
Zurück zum Zitat Dillon MF, Curran J, Martos R, Walsh C, Walsh J, Al-Azawi D, et al. Factors that affect longevity of intravenous cannulas: a prospective study. QJM. 2008;101(9):731–5.PubMedCrossRef Dillon MF, Curran J, Martos R, Walsh C, Walsh J, Al-Azawi D, et al. Factors that affect longevity of intravenous cannulas: a prospective study. QJM. 2008;101(9):731–5.PubMedCrossRef
7.
Zurück zum Zitat Goff DA, Larsen P, Brinkley J, Eldridge D, Newton D, Hartzog T, et al. Resource utilization and cost of inserting peripheral intravenous catheters in hospitalized children. Hospital pediatrics. 2013;3(3):185–91.PubMedCrossRef Goff DA, Larsen P, Brinkley J, Eldridge D, Newton D, Hartzog T, et al. Resource utilization and cost of inserting peripheral intravenous catheters in hospitalized children. Hospital pediatrics. 2013;3(3):185–91.PubMedCrossRef
8.
Zurück zum Zitat Seymour CW, Cooke CR, Heckbert SR, Spertus JA, Callaway CW, Martin-Gill C, et al. Prehospital intravenous access and fluid resuscitation in severe sepsis: an observational cohort study. Critical care (London, England). 2014;18(5):533.CrossRef Seymour CW, Cooke CR, Heckbert SR, Spertus JA, Callaway CW, Martin-Gill C, et al. Prehospital intravenous access and fluid resuscitation in severe sepsis: an observational cohort study. Critical care (London, England). 2014;18(5):533.CrossRef
9.
Zurück zum Zitat Tuffaha HW, Marsh N, Byrnes J, Gavin N, Webster J, Cooke M, et al. Cost of vascular access devices in public hospitals in Queensland. Aust Health Rev. 2018;43(5):511-5. Tuffaha HW, Marsh N, Byrnes J, Gavin N, Webster J, Cooke M, et al. Cost of vascular access devices in public hospitals in Queensland. Aust Health Rev. 2018;43(5):511-5.
10.
Zurück zum Zitat O'Neill MB, Dillane M, Hanipah NF. Validating the difficult intravenous access clinical prediction rule. Pediatr Emerg Care. 2012;28(12):1314–6.PubMedCrossRef O'Neill MB, Dillane M, Hanipah NF. Validating the difficult intravenous access clinical prediction rule. Pediatr Emerg Care. 2012;28(12):1314–6.PubMedCrossRef
11.
Zurück zum Zitat Riker MW, Kennedy C, Winfrey BS, Yen K, Dowd MD. Validation and refinement of the difficult intravenous access score: a clinical prediction rule for identifying children with difficult intravenous access. Acad Emerg Med. 2011;18(11):1129–34.PubMedCrossRef Riker MW, Kennedy C, Winfrey BS, Yen K, Dowd MD. Validation and refinement of the difficult intravenous access score: a clinical prediction rule for identifying children with difficult intravenous access. Acad Emerg Med. 2011;18(11):1129–34.PubMedCrossRef
12.
Zurück zum Zitat Tuffaha HW, Rickard CM, Inwood S, Gordon L, Scuffham P. The epic3 recommendation that clinically indicated replacement of peripheral venous catheters is safe and cost-saving: how much would the NHS save? J Hosp Infec. 2014;87(3):183–4.CrossRef Tuffaha HW, Rickard CM, Inwood S, Gordon L, Scuffham P. The epic3 recommendation that clinically indicated replacement of peripheral venous catheters is safe and cost-saving: how much would the NHS save? J Hosp Infec. 2014;87(3):183–4.CrossRef
13.
Zurück zum Zitat Schults J, Rickard C, Kleidon T, Paterson R, Macfarlane F, Ullman A. Difficult peripheral venous access in children: an international survey and critical appraisal of assessment tools and escalation pathways. J Nurs Scholarsh. 2019;51(5):537–46.PubMedCrossRef Schults J, Rickard C, Kleidon T, Paterson R, Macfarlane F, Ullman A. Difficult peripheral venous access in children: an international survey and critical appraisal of assessment tools and escalation pathways. J Nurs Scholarsh. 2019;51(5):537–46.PubMedCrossRef
14.
Zurück zum Zitat Girotto C, Arpone M, Frigo AC, Micheletto M, Mazza A, Da Dalt L, et al. External validation of the DIVA and DIVA3 clinical predictive rules to identify difficult intravenous access in paediatric patients. Emerg Med J. 2020;37(12):762.PubMed Girotto C, Arpone M, Frigo AC, Micheletto M, Mazza A, Da Dalt L, et al. External validation of the DIVA and DIVA3 clinical predictive rules to identify difficult intravenous access in paediatric patients. Emerg Med J. 2020;37(12):762.PubMed
15.
Zurück zum Zitat Yen K, Riegert A, Gorelick MH. Derivation of the DIVA score: a clinical prediction rule for the identification of children with difficult intravenous access. Pediatr Emerg Care. 2008;24(3):143–7.PubMedCrossRef Yen K, Riegert A, Gorelick MH. Derivation of the DIVA score: a clinical prediction rule for the identification of children with difficult intravenous access. Pediatr Emerg Care. 2008;24(3):143–7.PubMedCrossRef
16.
Zurück zum Zitat de Souza Freire MH, Arreguy-Sena C, Souza d, de Souza Müller PC. Cross-cultural adaptation and content and semantic validation of the difficult intravenous access score for pediatric use in Brazil. Revista Latino-Americana de Enfermagem. 2017;25:e2920. de Souza Freire MH, Arreguy-Sena C, Souza d, de Souza Müller PC. Cross-cultural adaptation and content and semantic validation of the difficult intravenous access score for pediatric use in Brazil. Revista Latino-Americana de Enfermagem. 2017;25:e2920.
17.
Zurück zum Zitat Yan Y, Gong M, Li D, Huang Y, Li A, Qiu J, et al. Grade Management in Establishing Pediatric Peripheral Venous Access. Iran J Pediatr. 2016;26(6):e6321. Yan Y, Gong M, Li D, Huang Y, Li A, Qiu J, et al. Grade Management in Establishing Pediatric Peripheral Venous Access. Iran J Pediatr. 2016;26(6):e6321.
18.
Zurück zum Zitat Hallam C, Weston V, Denton A, Hill S, Bodenham A, Dunn H, et al. Development of the UK vessel health and preservation (VHP) framework: a multi-organisational collaborative. J Infect Preven. 2016;17(2):65–72.CrossRef Hallam C, Weston V, Denton A, Hill S, Bodenham A, Dunn H, et al. Development of the UK vessel health and preservation (VHP) framework: a multi-organisational collaborative. J Infect Preven. 2016;17(2):65–72.CrossRef
19.
Zurück zum Zitat Hawkins J, Madden K, Fletcher A, Midgley L, Grant A, Cox G, et al. Development of a framework for the co-production and prototyping of public health interventions. BMC Public Health. 2017;17(1):689.PubMedPubMedCentralCrossRef Hawkins J, Madden K, Fletcher A, Midgley L, Grant A, Cox G, et al. Development of a framework for the co-production and prototyping of public health interventions. BMC Public Health. 2017;17(1):689.PubMedPubMedCentralCrossRef
20.
Zurück zum Zitat von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP. The strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies. Ann Intern Med. 2007;147(8):573–7.CrossRef von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP. The strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies. Ann Intern Med. 2007;147(8):573–7.CrossRef
21.
Zurück zum Zitat Mokkink LB, Terwee CB, Patrick DL, Alonso J, Stratford PW, Knol DL, et al. The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study. Qual Life Res. 2010;19(4):539–49.PubMedPubMedCentralCrossRef Mokkink LB, Terwee CB, Patrick DL, Alonso J, Stratford PW, Knol DL, et al. The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study. Qual Life Res. 2010;19(4):539–49.PubMedPubMedCentralCrossRef
22.
Zurück zum Zitat Norwood SL. Research essential: foundations for evidence-based practice. New Jersey: Pearson; 2010. Norwood SL. Research essential: foundations for evidence-based practice. New Jersey: Pearson; 2010.
23.
Zurück zum Zitat Braun V, Clarke V. Using thematic analysis in psychology. Qual Res Psychol. 2006;3(2):77–101.CrossRef Braun V, Clarke V. Using thematic analysis in psychology. Qual Res Psychol. 2006;3(2):77–101.CrossRef
24.
Zurück zum Zitat Cairney P, Oliver K. Evidence-based policymaking is not like evidence-based medicine, so how far should you go to bridge the divide between evidence and policy? Health Research Policy and Systems. 2017;15(1):35.PubMedPubMedCentralCrossRef Cairney P, Oliver K. Evidence-based policymaking is not like evidence-based medicine, so how far should you go to bridge the divide between evidence and policy? Health Research Policy and Systems. 2017;15(1):35.PubMedPubMedCentralCrossRef
25.
Zurück zum Zitat Koch T. Establishing rigour in qualitative research: the decision trail. J Adv Nurs. 2006;53(1):91–100.PubMedCrossRef Koch T. Establishing rigour in qualitative research: the decision trail. J Adv Nurs. 2006;53(1):91–100.PubMedCrossRef
26.
Zurück zum Zitat Oliver K, Kothari A, Mays N. The dark side of coproduction: do the costs outweigh the benefits for health research? Health Research Policy and Systems. 2019;17(1):33.PubMedPubMedCentralCrossRef Oliver K, Kothari A, Mays N. The dark side of coproduction: do the costs outweigh the benefits for health research? Health Research Policy and Systems. 2019;17(1):33.PubMedPubMedCentralCrossRef
27.
Zurück zum Zitat Lloyd-Williams F, Hyseni L, Guzman-Castillo M, Kypridemos C, Collins B, Capewell S, et al. Evaluating stakeholder involvement in building a decision support tool for NHS health checks: co-producing the WorkHORSE study. BMC Med Inform Decision Making. 2020;20(1):182.CrossRef Lloyd-Williams F, Hyseni L, Guzman-Castillo M, Kypridemos C, Collins B, Capewell S, et al. Evaluating stakeholder involvement in building a decision support tool for NHS health checks: co-producing the WorkHORSE study. BMC Med Inform Decision Making. 2020;20(1):182.CrossRef
28.
Zurück zum Zitat Pohl C, Rist S, Zimmermann A, Fry P, Gurung GS, Schneider F, et al. Researchers' roles in knowledge co-production: experience from sustainability research in Kenya, Switzerland, Bolivia and Nepal. Sci Public Policy. 2010;37(4):267–81.CrossRef Pohl C, Rist S, Zimmermann A, Fry P, Gurung GS, Schneider F, et al. Researchers' roles in knowledge co-production: experience from sustainability research in Kenya, Switzerland, Bolivia and Nepal. Sci Public Policy. 2010;37(4):267–81.CrossRef
29.
Zurück zum Zitat Rippey JC, Carr PJ, Cooke M, Higgins N, Rickard CM. Predicting and preventing peripheral intravenous cannula insertion failure in the emergency department: clinician 'gestalt' wins again. Emerg Med Australas. 2016;28(6):658–65.PubMedCrossRef Rippey JC, Carr PJ, Cooke M, Higgins N, Rickard CM. Predicting and preventing peripheral intravenous cannula insertion failure in the emergency department: clinician 'gestalt' wins again. Emerg Med Australas. 2016;28(6):658–65.PubMedCrossRef
30.
Zurück zum Zitat Palinkas LA, Horwitz SM, Green CA, Wisdom JP, Duan N, Hoagwood K. Purposeful sampling for qualitative data collection and analysis in mixed method implementation research. Admin Pol Ment Health. 2015;42(5):533–44.CrossRef Palinkas LA, Horwitz SM, Green CA, Wisdom JP, Duan N, Hoagwood K. Purposeful sampling for qualitative data collection and analysis in mixed method implementation research. Admin Pol Ment Health. 2015;42(5):533–44.CrossRef
32.
Zurück zum Zitat Kuensting LL, DeBoer S, Holleran R, Shultz BL, Steinmann RA, Venella J. Difficult venous access in children: taking control. J Emerg Nurs. 2009;35(5):419–24.PubMedCrossRef Kuensting LL, DeBoer S, Holleran R, Shultz BL, Steinmann RA, Venella J. Difficult venous access in children: taking control. J Emerg Nurs. 2009;35(5):419–24.PubMedCrossRef
33.
Zurück zum Zitat Larsen P, Eldridge D, Brinkley J, Newton D, Goff D, Hartzog T, et al. Pediatric peripheral intravenous access: does nursing experience and competence really make a difference? J Infus Nurs. 2010;33(4):226–35.PubMedCrossRef Larsen P, Eldridge D, Brinkley J, Newton D, Goff D, Hartzog T, et al. Pediatric peripheral intravenous access: does nursing experience and competence really make a difference? J Infus Nurs. 2010;33(4):226–35.PubMedCrossRef
34.
Zurück zum Zitat Stolz LA, Cappa AR, Minckler MR, Stolz U, Wyatt RG, Binger CW, et al. Prospective evaluation of the learning curve for ultrasound-guided peripheral intravenous catheter placement. J Vasc Access. 2016;17(4):366–70.PubMedCrossRef Stolz LA, Cappa AR, Minckler MR, Stolz U, Wyatt RG, Binger CW, et al. Prospective evaluation of the learning curve for ultrasound-guided peripheral intravenous catheter placement. J Vasc Access. 2016;17(4):366–70.PubMedCrossRef
35.
Zurück zum Zitat Friedrichsdorf SJ, Eull D, Weidner C, Postier A. A hospital-wide initiative to eliminate or reduce needle pain in children using lean methodology. Pain Rep. 2018;3(Suppl 1):e671-e.CrossRef Friedrichsdorf SJ, Eull D, Weidner C, Postier A. A hospital-wide initiative to eliminate or reduce needle pain in children using lean methodology. Pain Rep. 2018;3(Suppl 1):e671-e.CrossRef
36.
Zurück zum Zitat Polit DF, Beck CT. The content validity index: are you sure you know what's being reported? Critique and recommendations. Res Nurs Health. 2006;29(5):489–97.PubMedCrossRef Polit DF, Beck CT. The content validity index: are you sure you know what's being reported? Critique and recommendations. Res Nurs Health. 2006;29(5):489–97.PubMedCrossRef
37.
Zurück zum Zitat Polit DF, Beck CT, Owen SV. Is the CVI an acceptable indicator of content validity? Appraisal and recommendations. Res Nurs Health. 2007;30(4):459–67.PubMedCrossRef Polit DF, Beck CT, Owen SV. Is the CVI an acceptable indicator of content validity? Appraisal and recommendations. Res Nurs Health. 2007;30(4):459–67.PubMedCrossRef
38.
Zurück zum Zitat Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG. Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform. 2009;42(2):377–81.CrossRef Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG. Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform. 2009;42(2):377–81.CrossRef
39.
Zurück zum Zitat Harris PA, Taylor R, Minor BL, Elliott V, Fernandez M, O'Neal L, et al. The REDCap consortium: building an international community of software platform partners. J Biomed Inform. 2019;95:103208.PubMedPubMedCentralCrossRef Harris PA, Taylor R, Minor BL, Elliott V, Fernandez M, O'Neal L, et al. The REDCap consortium: building an international community of software platform partners. J Biomed Inform. 2019;95:103208.PubMedPubMedCentralCrossRef
40.
Zurück zum Zitat Schults JA, Rickard CM, Kleidon T, Hughes R, Macfarlane F, Hung J, et al. Building a global, pediatric vascular access registry: a scoping review of trial outcomes and quality indicators to inform evidence-based practice. Worldviews Evid-Based Nurs. 2019;16(1):51-9. Schults JA, Rickard CM, Kleidon T, Hughes R, Macfarlane F, Hung J, et al. Building a global, pediatric vascular access registry: a scoping review of trial outcomes and quality indicators to inform evidence-based practice. Worldviews Evid-Based Nurs. 2019;16(1):51-9.
41.
Zurück zum Zitat Hands C, Round J, Thomas J. Evaluating venepuncture practice on a general children's ward. Paediatr Nurs. 2010;22(2):32–5.PubMedCrossRef Hands C, Round J, Thomas J. Evaluating venepuncture practice on a general children's ward. Paediatr Nurs. 2010;22(2):32–5.PubMedCrossRef
42.
Zurück zum Zitat van Loon FHJ, van Hooff LWE, de Boer HD, Koopman S, Buise MP, Korsten HHM, et al. The modified A-DIVA scale as a predictive tool for prospective identification of adult patients at risk of a difficult intravenous access: a multicenter validation study. J Clin Med. 2019;8(2):144. van Loon FHJ, van Hooff LWE, de Boer HD, Koopman S, Buise MP, Korsten HHM, et al. The modified A-DIVA scale as a predictive tool for prospective identification of adult patients at risk of a difficult intravenous access: a multicenter validation study. J Clin Med. 2019;8(2):144.
43.
Zurück zum Zitat Australian Commission on Safety and Quality in Health Care. Management of Peripheral Intravenous Catheters Clinical Care Standard. ACSQHC; 2021. p. 1-54. Australian Commission on Safety and Quality in Health Care. Management of Peripheral Intravenous Catheters Clinical Care Standard. ACSQHC; 2021. p. 1-54.
44.
Zurück zum Zitat Mahlan E. Again? Repetition in teaching and learning. J Christ Nurs. 2018;35(3):200. Mahlan E. Again? Repetition in teaching and learning. J Christ Nurs. 2018;35(3):200.
45.
Zurück zum Zitat MacDougall-Davis SR, Kettley L, Cook TM. The ‘go-between’ study: a simulation study comparing the ‘traffic lights’ and ‘SBAR’ tools as a means of communication between anaesthetic staff. Anaesthesia. 2016;71(7):764–72.PubMedCrossRef MacDougall-Davis SR, Kettley L, Cook TM. The ‘go-between’ study: a simulation study comparing the ‘traffic lights’ and ‘SBAR’ tools as a means of communication between anaesthetic staff. Anaesthesia. 2016;71(7):764–72.PubMedCrossRef
46.
Zurück zum Zitat Hallam C, Denton A, Weston V, Dunn H, Jackson T, Keeling S, et al. UK vessel health and preservation (VHP) framework: a commentary on the updated VHP 2020. J Infect Prev. 2020;22(4):147–55.PubMedCrossRef Hallam C, Denton A, Weston V, Dunn H, Jackson T, Keeling S, et al. UK vessel health and preservation (VHP) framework: a commentary on the updated VHP 2020. J Infect Prev. 2020;22(4):147–55.PubMedCrossRef
47.
Zurück zum Zitat Lidskog R, Sundqvist G. From consensus to credibility. Innovation: European J Soc Sci Res. 2004;17(3):205–26. Lidskog R, Sundqvist G. From consensus to credibility. Innovation: European J Soc Sci Res. 2004;17(3):205–26.
48.
Zurück zum Zitat Camden C, Shikako-Thomas K, Nguyen T, Graham E, Thomas A, Sprung J, et al. Engaging stakeholders in rehabilitation research: a scoping review of strategies used in partnerships and evaluation of impacts. Disabil Rehabil. 2015;37(15):1390–400.PubMedCrossRef Camden C, Shikako-Thomas K, Nguyen T, Graham E, Thomas A, Sprung J, et al. Engaging stakeholders in rehabilitation research: a scoping review of strategies used in partnerships and evaluation of impacts. Disabil Rehabil. 2015;37(15):1390–400.PubMedCrossRef
49.
Zurück zum Zitat Traube C, Silver G, Kearney J, Patel A, Atkinson TM, Yoon MJ, et al. Cornell assessment of pediatric delirium: a valid, rapid, observational tool for screening delirium in the PICU*. Crit Care Med. 2014;42(3):656–63.PubMedPubMedCentralCrossRef Traube C, Silver G, Kearney J, Patel A, Atkinson TM, Yoon MJ, et al. Cornell assessment of pediatric delirium: a valid, rapid, observational tool for screening delirium in the PICU*. Crit Care Med. 2014;42(3):656–63.PubMedPubMedCentralCrossRef
50.
Zurück zum Zitat Paterson RS, Kenardy JA, Dow BL, De Young AC, Pearson K, Aitken LM, et al. Accuracy of delirium assessments in critically ill children: a prospective, observational study during routine care. Aust Crit Care. 2021;34(3):226–34.PubMedCrossRef Paterson RS, Kenardy JA, Dow BL, De Young AC, Pearson K, Aitken LM, et al. Accuracy of delirium assessments in critically ill children: a prospective, observational study during routine care. Aust Crit Care. 2021;34(3):226–34.PubMedCrossRef
Metadaten
Titel
Improving peripheral venous cannula insertion in children: a mixed methods study to develop the DIVA key
verfasst von
Jessica A. Schults
Tricia M. Kleidon
Victoria Gibson
Robert S. Ware
Emily Monteagle
Rebecca Paterson
Karina Charles
Adam Keys
Craig A. McBride
Steven McTaggart
Benjamin Lawton
Fiona Macfarlane
Chloe Sells
Claire M. Rickard
Amanda J. Ullman
Publikationsdatum
01.12.2022
Verlag
BioMed Central
Erschienen in
BMC Health Services Research / Ausgabe 1/2022
Elektronische ISSN: 1472-6963
DOI
https://doi.org/10.1186/s12913-022-07605-2

Weitere Artikel der Ausgabe 1/2022