Light transmittance dynamics and spectral absorption characteristics during auxiliary cryogen spray cooling in laser dermatology

verfasst von: Jiameng Tian, Bin Chen, Dong Li

Erschienen in: Lasers in Medical Science | Ausgabe 3/2022

Einloggen, um Zugang zu erhalten

Abstract

Cryogen spray cooling (CSC) is widely applied in laser dermatologic surgery to minimize the risk of non-specific epidermal thermal damage caused by the competitive laser energy absorption of epidermal melanin. However, the light absorption and attenuation by cryogen film and subsequent frost formation on the skin surface during CSC are needed to be investigated by using R-134a, R-404A, and R-32. A spray system equipped with an integrating sphere-based light collection apparatus was constructed to evaluate the time-resolved laser transmittance and spectral absorption characteristics induced by R-134a, R-404A, and R-32 sprays, under the clinical-used 755-nm and 1064-nm laser irradiations. No obvious light absorption peaks exist in the wavelengths of 370–1400 nm. R-404A produces the largest average light absorbance (0.089), as compared to those of R-134a (0.066) and R-32 (0.068) in the near-infrared range (780–1400 nm). Given the lowest boiling point and highest latent heat of R-32, the evaporation of liquid film and melting of subsequent frost are promoted, leading to smallest light attenuation. R-32 spray shows great potential in clinics owing to its high light transmittance, small light absorption, and high cooling capability. For R-32 spray, the durations between spurt termination and laser irradiation are recommended to be 8–100 ms and 13–100 ms with average light transmittances of 86% and 95% under 755-nm and 1064-nm laser irradiations.
Literatur
6.
Zurück zum Zitat Ramirezsanjuan JC, Choi B, Franco W, Nelson JS, Aguilar G (2005) Effects of relative humidity on laser light transmittance during cryogen spray cooling of in vitro skin phantoms. Proceedings of SPIE - the International Society for Optical Engineering 5686:154–158. https://doi.org/10.1117/12.591197CrossRef Ramirezsanjuan JC, Choi B, Franco W, Nelson JS, Aguilar G (2005) Effects of relative humidity on laser light transmittance during cryogen spray cooling of in vitro skin phantoms. Proceedings of SPIE - the International Society for Optical Engineering 5686:154–158. https://​doi.​org/​10.​1117/​12.​591197CrossRef
8.
Zurück zum Zitat Choi B, Aguilar G, Vargas G (2002) Dynamic measurements of laser light attenuation by cryogen film and frost formation. In: Proceedings of SPIE - The International Society for Optical Engineering, 2002. SPIE. doi: https://doi.org/10.1117/12.432051 Choi B, Aguilar G, Vargas G (2002) Dynamic measurements of laser light attenuation by cryogen film and frost formation. In: Proceedings of SPIE - The International Society for Optical Engineering, 2002. SPIE. doi: https://​doi.​org/​10.​1117/​12.​432051
10.
Zurück zum Zitat Pikkula BM, Domankevitz Y, Tunnell JW, Anvari B (2002) Cryogen spray cooling: effects of cryogen film on heat removal and light transmission. In: Proceedings of SPIE - The International Society for Optical Engineering. SPIE, pp 50–56. https://doi.org/10.1117/12.432078 Pikkula BM, Domankevitz Y, Tunnell JW, Anvari B (2002) Cryogen spray cooling: effects of cryogen film on heat removal and light transmission. In: Proceedings of SPIE - The International Society for Optical Engineering. SPIE, pp 50–56. https://​doi.​org/​10.​1117/​12.​432078
11.
Zurück zum Zitat Tianhong D, A YM, Parmeswaran D, W CD, Bahman A (2006) Comparative study of cryogen spray cooling with R-134a and R-404a: implications for laser treatment of dark human skin. Journal of biomedical optics 11 (4). doi:https://doi.org/10.1117/1.2338001 Tianhong D, A YM, Parmeswaran D, W CD, Bahman A (2006) Comparative study of cryogen spray cooling with R-134a and R-404a: implications for laser treatment of dark human skin. Journal of biomedical optics 11 (4). doi:https://​doi.​org/​10.​1117/​1.​2338001
15.
Zurück zum Zitat Dossat RJ (1991) Principles of refrigeration. Prentice Hall, Englewood Cliffs, NJ, USA Dossat RJ (1991) Principles of refrigeration. Prentice Hall, Englewood Cliffs, NJ, USA
19.
Zurück zum Zitat Aguilar G, Verkruysse W, Majaron B, Svaasand LO, Lavernia EJ, Nelson JS (2001) Measurement of heat flux and heat transfer coefficient during continuous cryogen spray cooling for laser dermatologic surgery. IEEE J Sel Top Quantum Electron 7(6):1013–1021. https://doi.org/10.1109/2944.983307CrossRef Aguilar G, Verkruysse W, Majaron B, Svaasand LO, Lavernia EJ, Nelson JS (2001) Measurement of heat flux and heat transfer coefficient during continuous cryogen spray cooling for laser dermatologic surgery. IEEE J Sel Top Quantum Electron 7(6):1013–1021. https://​doi.​org/​10.​1109/​2944.​983307CrossRef
Metadaten
Titel
Light transmittance dynamics and spectral absorption characteristics during auxiliary cryogen spray cooling in laser dermatology
verfasst von
Jiameng Tian
Bin Chen
Dong Li
Publikationsdatum
29.01.2022
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 3/2022
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-022-03512-4

Weitere Artikel der Ausgabe 3/2022

Lasers in Medical Science 3/2022 Zur Ausgabe