Measurement of fetal automated fractional shortening using two-dimensional tracking in multiple centers

Erschienen in: Journal of Medical Ultrasonics | Ausgabe 1/2021

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To establish a normal reference range for automated fractional shortening (Auto FS) in normal singleton fetuses measured at multiple centers.

Methods

This study was conducted from May 2017 to March 2019. It was undertaken on normal singleton fetuses. First, a four-chamber view of the fetal heart was recorded in the B-mode. Then, the region of interest was set on the edge of the ventricular septum and on the edge of the ventricular muscle at a point one-third away from the atrioventricular valve and toward the cardiac apex. Tracking was automatically performed. Values measured in the right ventricle were defined as R-Auto FS, and in the left ventricle as L-Auto FS. Furthermore, combined-Auto FS was defined as the measurement across both ventricles.

Results

A total of 442 normal fetuses were assessed. R-Auto FS decreased significantly with gestational age, and L-Auto FS showed a similar tendency (Spearman’s correlation analysis: rs =  − 0.415 and rs =  − 0.252, respectively). Combined-Auto FS showed a similar decline as the gestational age increased (rs =  − 0.451).

Conclusion

In this study, we succeeded in defining a reference Auto FS value not only at one institution but also multiple centers. This study suggests that Auto FS can be used clinically and effectively.
Literatur
1.
Zurück zum Zitat Nakata M, Sakuma J, Takano M, Nagasaki S. Assessment of fetal cardiac function with echocardiography. J Obstet Gynaecol Res. 2020;46:31–8.CrossRef Nakata M, Sakuma J, Takano M, Nagasaki S. Assessment of fetal cardiac function with echocardiography. J Obstet Gynaecol Res. 2020;46:31–8.CrossRef
2.
Zurück zum Zitat DeVore GR, Klas B, Satou G, Sklansky M. Twenty-four segment transverse ventricular fractional shortening: a new technique to evaluate fetal cardiac function. J Ultrasound Med. 2018;37:1129–41.CrossRef DeVore GR, Klas B, Satou G, Sklansky M. Twenty-four segment transverse ventricular fractional shortening: a new technique to evaluate fetal cardiac function. J Ultrasound Med. 2018;37:1129–41.CrossRef
3.
Zurück zum Zitat Luewan S, Yanase Y, Tongprasert F, Srisupundit K, Tongsong T. Fetal cardiac dimensions at 14–40 weeks’ gestation obtained using cardio-STIC-M. Ultrasound Obstet Gynecol. 2011;37:416–22.CrossRef Luewan S, Yanase Y, Tongprasert F, Srisupundit K, Tongsong T. Fetal cardiac dimensions at 14–40 weeks’ gestation obtained using cardio-STIC-M. Ultrasound Obstet Gynecol. 2011;37:416–22.CrossRef
4.
Zurück zum Zitat Nagasaki S, Nakata M, Takano M, Usui K, Sakuma J, Hayata E, et al. Feasibility of automated fetal fractional shortening measurement with two-dimensional tracking and construction of a reference range for normal fetuses. J Med Ultrason. 2001;2019(46):467–72. Nagasaki S, Nakata M, Takano M, Usui K, Sakuma J, Hayata E, et al. Feasibility of automated fetal fractional shortening measurement with two-dimensional tracking and construction of a reference range for normal fetuses. J Med Ultrason. 2001;2019(46):467–72.
5.
Zurück zum Zitat Royston P, Wright EM. How to construct ‘normal ranges’ for fetal variables. Ultrasound Obst Gyn. 1998;11:30–8.CrossRef Royston P, Wright EM. How to construct ‘normal ranges’ for fetal variables. Ultrasound Obst Gyn. 1998;11:30–8.CrossRef
6.
Zurück zum Zitat DeVore GR. Computing the Z Score and centiles for cross-sectional analysis: a practical approach. J Ultrasound Med. 2017;36:459–73.CrossRef DeVore GR. Computing the Z Score and centiles for cross-sectional analysis: a practical approach. J Ultrasound Med. 2017;36:459–73.CrossRef
7.
Zurück zum Zitat Takano M, Nakata M, Nagasaki S, Ueyama R, Morita M. Assessment of diastolic function of normal fetal heart using dual-gate Doppler. Ultrasound Obstet Gynecol. 2018;52:238–42.CrossRef Takano M, Nakata M, Nagasaki S, Ueyama R, Morita M. Assessment of diastolic function of normal fetal heart using dual-gate Doppler. Ultrasound Obstet Gynecol. 2018;52:238–42.CrossRef
8.
Zurück zum Zitat Huhta JC. Guidelines for the evaluation of heart failure in the fetus with or without hydrops. Pediatr Cardiol. 2004;25:274–86.CrossRef Huhta JC. Guidelines for the evaluation of heart failure in the fetus with or without hydrops. Pediatr Cardiol. 2004;25:274–86.CrossRef
9.
Zurück zum Zitat Vore GR, Siassi B, Platt LD. Fetal echocardiography. IV. M-mode assessment of ventricular size and contractility during the second and third trimesters of pregnancy in the normal fetus. Am J Obstet Gynecol. 1984;150:981–8.CrossRef Vore GR, Siassi B, Platt LD. Fetal echocardiography. IV. M-mode assessment of ventricular size and contractility during the second and third trimesters of pregnancy in the normal fetus. Am J Obstet Gynecol. 1984;150:981–8.CrossRef
10.
Zurück zum Zitat John Sutton MG, Gewitz MH, Shah B, Cohen A, Reichek N, Gabbe S, et al. Quantitative assessment of growth and function of the cardiac chambers in the normal human fetus: a prospective longitudinal echocardiographic study. Circulation. 1984;69:645–54.CrossRef John Sutton MG, Gewitz MH, Shah B, Cohen A, Reichek N, Gabbe S, et al. Quantitative assessment of growth and function of the cardiac chambers in the normal human fetus: a prospective longitudinal echocardiographic study. Circulation. 1984;69:645–54.CrossRef
11.
Zurück zum Zitat Johnson P, Maxwell DJ, Tynan MJ, Allan LD. Intracardiac pressures in the human fetus. Heart. 2000;84:59–63.CrossRef Johnson P, Maxwell DJ, Tynan MJ, Allan LD. Intracardiac pressures in the human fetus. Heart. 2000;84:59–63.CrossRef
12.
Zurück zum Zitat Rasanen J, Wood DC, Weiner S, Ludomirski A, Huhta JC. Role of the pulmonary circulation in the distribution of human fetal cardiac output during the second half of pregnancy. Circulation. 1996;94:1068–73.CrossRef Rasanen J, Wood DC, Weiner S, Ludomirski A, Huhta JC. Role of the pulmonary circulation in the distribution of human fetal cardiac output during the second half of pregnancy. Circulation. 1996;94:1068–73.CrossRef
Metadaten
Titel
Measurement of fetal automated fractional shortening using two-dimensional tracking in multiple centers
Publikationsdatum
11.01.2021
Erschienen in
Journal of Medical Ultrasonics / Ausgabe 1/2021
Print ISSN: 1346-4523
Elektronische ISSN: 1613-2254
DOI
https://doi.org/10.1007/s10396-020-01069-9

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.