Skip to main content
Erschienen in: Current Cardiology Reports 7/2022

19.05.2022 | Interventional Cardiology (SR Bailey and T Helmy, Section Editors)

Safety and Efficacy of Robotic-Assisted PCI

verfasst von: Samir B. Pancholy, Sanjay C. Shah, Tejas M. Patel

Erschienen in: Current Cardiology Reports | Ausgabe 7/2022

Einloggen, um Zugang zu erhalten

Abstract

Purpose of review

Robotics has been used in multiple areas of procedural medical intervention. Robotic percutaneous coronary intervention (PCI) has been available since 2004. Its adoption has been slow with initial application in simple cases.

Recent findings

With increasing adoption, robotic PCI has been applied to a broader variety of coronary substrates with demonstration of safety and efficacy. Improvements in the robotic console with future generation devices should add to the utility of this platform.

Summary

Robotic PCI advances the innovations in endovascular space into a different dimension, removing the dependence of the procedure on patient-operator ergonomics and likely operator skill.
Literatur
1.
Zurück zum Zitat Klein LW, Goldstein JA, Haines D, Chambers C, Mehran R, Kort S, et al. SCAI multi-society position statement on occupational health hazards of the catheterization laboratory: shifting the paradigm for healthcare workers’ protection. Catheter Cardiovasc Interv. 2020;95(7):1327–33.CrossRef Klein LW, Goldstein JA, Haines D, Chambers C, Mehran R, Kort S, et al. SCAI multi-society position statement on occupational health hazards of the catheterization laboratory: shifting the paradigm for healthcare workers’ protection. Catheter Cardiovasc Interv. 2020;95(7):1327–33.CrossRef
2.
Zurück zum Zitat Sepehripour AH, Garas G, Athanasiou T, Casula R. Robotics in cardiac surgery. Ann R Coll Surg Engl. 2018;100(Suppl 7):22–33. Sepehripour AH, Garas G, Athanasiou T, Casula R. Robotics in cardiac surgery. Ann R Coll Surg Engl. 2018;100(Suppl 7):22–33.
3.
Zurück zum Zitat •• Beyar R, Wenderow T, Lindner D, Kumar G, Shofti R. Concept, design and pre-clinical studies for remote control percutaneous coronary interventions. EuroIntervention. 2005;1(3):340–345. •• Beyar R, Wenderow T, Lindner D, Kumar G, Shofti R. Concept, design and pre-clinical studies for remote control percutaneous coronary interventions. EuroIntervention. 2005;1(3):340–345.
4.
Zurück zum Zitat •• Granada JF, Delgado JA, Uribe MP, Fernandez A, Blanco G, Leon MB, et al. First-in-human evaluation of a novel robotic-assisted coronary angioplasty system. JACC Cardiovasc Interv. 2011;4(4):460–465. •• Granada JF, Delgado JA, Uribe MP, Fernandez A, Blanco G, Leon MB, et al. First-in-human evaluation of a novel robotic-assisted coronary angioplasty system. JACC Cardiovasc Interv. 2011;4(4):460–465.
5.
Zurück zum Zitat Maor E, Eleid MF, Gulati R, Lerman A, Sandhu GA. Current and future use of robotic devices to perform percutaneous coronary interventions: a review. J Am Heart Assoc. 2017;6(7): e006239.CrossRef Maor E, Eleid MF, Gulati R, Lerman A, Sandhu GA. Current and future use of robotic devices to perform percutaneous coronary interventions: a review. J Am Heart Assoc. 2017;6(7): e006239.CrossRef
6.
Zurück zum Zitat Mangels DR, Giri J, Hirshfeld J, Wilensky RL. Robotic-assisted percutaneous coronary intervention. Catheter Cardiovasc Interv. 2017;90(6):948–55.CrossRef Mangels DR, Giri J, Hirshfeld J, Wilensky RL. Robotic-assisted percutaneous coronary intervention. Catheter Cardiovasc Interv. 2017;90(6):948–55.CrossRef
7.
Zurück zum Zitat Al Nooryani A, Aboushokka W. Rotate-on-retract procedural automation for robotic-assisted percutaneous coronary intervention: first clinical experience. Case Rep Cardiol. 2018;2018:6086034.PubMedPubMedCentral Al Nooryani A, Aboushokka W. Rotate-on-retract procedural automation for robotic-assisted percutaneous coronary intervention: first clinical experience. Case Rep Cardiol. 2018;2018:6086034.PubMedPubMedCentral
8.
Zurück zum Zitat • Weisz G, Metzger DC, Caputo RP, Delgado JA, Marshall JJ, Vetrovec GW, et al. Safety and feasibility of robotic percutaneous coronary intervention: PRECISE (Percutaneous Robotically-Enhanced Coronary Intervention) Study. J Am Coll Cardiol. 2013;61(15):1596–600. First large study demonstrating safety and efficacy of robotic PCI.CrossRef • Weisz G, Metzger DC, Caputo RP, Delgado JA, Marshall JJ, Vetrovec GW, et al. Safety and feasibility of robotic percutaneous coronary intervention: PRECISE (Percutaneous Robotically-Enhanced Coronary Intervention) Study. J Am Coll Cardiol. 2013;61(15):1596–600. First large study demonstrating safety and efficacy of robotic PCI.CrossRef
9.
Zurück zum Zitat Kagiyama K, Mitsutake Y, Ueno T, Sakai S, Nakamura T, Yamaji K, et al. Successful introduction of robotic-assisted percutaneous coronary intervention system into Japanese clinical practice: a first-year survey at single center. Heart Vessels. 2021;36(7):955–64.CrossRef Kagiyama K, Mitsutake Y, Ueno T, Sakai S, Nakamura T, Yamaji K, et al. Successful introduction of robotic-assisted percutaneous coronary intervention system into Japanese clinical practice: a first-year survey at single center. Heart Vessels. 2021;36(7):955–64.CrossRef
10.
Zurück zum Zitat • Mahmud E, Naghi J, Ang L, Harrison J, Behnamfar O, Pourdjabbar A, et al. Demonstration of the safety and feasibility of robotically assisted percutaneous coronary intervention in complex coronary lesions: results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention). JACC Cardiovasc Interv. 2017;10(13):1320–1327. • Mahmud E, Naghi J, Ang L, Harrison J, Behnamfar O, Pourdjabbar A, et al. Demonstration of the safety and feasibility of robotically assisted percutaneous coronary intervention in complex coronary lesions: results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention). JACC Cardiovasc Interv. 2017;10(13):1320–1327.
11.
Zurück zum Zitat • Walters D, Reeves RR, Patel M, Naghi J, Ang L, Mahmud E. Complex robotic compared to manual coronary interventions: 6- and 12-month outcomes. Catheter Cardiovasc Interv. 2019;93(4):613–617. • Walters D, Reeves RR, Patel M, Naghi J, Ang L, Mahmud E. Complex robotic compared to manual coronary interventions: 6- and 12-month outcomes. Catheter Cardiovasc Interv. 2019;93(4):613–617.
12.
Zurück zum Zitat Hirai T, Kearney K, Kataruka A, Gosch KL, Brandt H, Nicholson WJ, et al. Initial report of safety and procedure duration of robotic-assisted chronic total occlusion coronary intervention. Catheter Cardiovasc Interv. 2020;95(1):165–9.CrossRef Hirai T, Kearney K, Kataruka A, Gosch KL, Brandt H, Nicholson WJ, et al. Initial report of safety and procedure duration of robotic-assisted chronic total occlusion coronary intervention. Catheter Cardiovasc Interv. 2020;95(1):165–9.CrossRef
13.
Zurück zum Zitat •• Patel TM, Shah SC, Soni YY, Radadiya R, Patel GA, Tiwari PO, et al. Comparison of robotic percutaneous coronary intervention with traditional percutaneous coronary intervention: a propensity score-matched analysis of a large cohort. Circ Cardiovasc Interv. 2020;13(5): e008888. This was the first large dataset that showed a significant reduction in radiation exposure to the patient with robotic PCI compared to traditional PCI.CrossRef •• Patel TM, Shah SC, Soni YY, Radadiya R, Patel GA, Tiwari PO, et al. Comparison of robotic percutaneous coronary intervention with traditional percutaneous coronary intervention: a propensity score-matched analysis of a large cohort. Circ Cardiovasc Interv. 2020;13(5): e008888. This was the first large dataset that showed a significant reduction in radiation exposure to the patient with robotic PCI compared to traditional PCI.CrossRef
14.
Zurück zum Zitat • Madder RD, VanOosterhout SM, Jacoby ME, Collins JS, Borgman AS, Mulder AN, et al. Percutaneous coronary intervention using a combination of robotics and telecommunications by an operator in a separate physical location from the patient: an early exploration into the feasibility of telestenting (the REMOTE-PCI study). EuroIntervention. 2017;12(1):1569–1576. • Madder RD, VanOosterhout SM, Jacoby ME, Collins JS, Borgman AS, Mulder AN, et al. Percutaneous coronary intervention using a combination of robotics and telecommunications by an operator in a separate physical location from the patient: an early exploration into the feasibility of telestenting (the REMOTE-PCI study). EuroIntervention. 2017;12(1):1569–1576.
15.
Zurück zum Zitat • Patel TM, Shah SC, Pancholy SB. Long distance tele-robotic-assisted percutaneous coronary intervention: a report of first-in-human experience. EClinicalMedicine. 2019;14:53–58. • Patel TM, Shah SC, Pancholy SB. Long distance tele-robotic-assisted percutaneous coronary intervention: a report of first-in-human experience. EClinicalMedicine. 2019;14:53–58.
16.
Zurück zum Zitat Madder RD, VanOosterhout S, Mulder A, Bush J, Martin S, Rash A, et al. Network latency and long-distance robotic telestenting: exploring the potential impact of network delays on telestenting performance. Catheter Cardiovasc Interv. 2020;95(5):914–9.CrossRef Madder RD, VanOosterhout S, Mulder A, Bush J, Martin S, Rash A, et al. Network latency and long-distance robotic telestenting: exploring the potential impact of network delays on telestenting performance. Catheter Cardiovasc Interv. 2020;95(5):914–9.CrossRef
17.
Zurück zum Zitat Madder RD, VanOosterhout S, Mulder A, Bush J, Martin S, Rash A. Feasibility of robotic telestenting over long geographic distances: a pre-clinical ex vivo and in vivo study. EuroIntervention. 2019;15(6):e510–2.CrossRef Madder RD, VanOosterhout S, Mulder A, Bush J, Martin S, Rash A. Feasibility of robotic telestenting over long geographic distances: a pre-clinical ex vivo and in vivo study. EuroIntervention. 2019;15(6):e510–2.CrossRef
Metadaten
Titel
Safety and Efficacy of Robotic-Assisted PCI
verfasst von
Samir B. Pancholy
Sanjay C. Shah
Tejas M. Patel
Publikationsdatum
19.05.2022
Verlag
Springer US
Erschienen in
Current Cardiology Reports / Ausgabe 7/2022
Print ISSN: 1523-3782
Elektronische ISSN: 1534-3170
DOI
https://doi.org/10.1007/s11886-022-01701-9

Weitere Artikel der Ausgabe 7/2022

Current Cardiology Reports 7/2022 Zur Ausgabe

Ischemic Heart Disease (D Mukherjee, Section Editor)

Treatment of Hypertension Among Non-Cardiac Hospitalized Patients

Public Health Policy (SS Virani and D Mahtta, Section Editors)

COVID’s Impact on Non-communicable Diseases: What We Do Not Know May Hurt Us

Management of Acute Coronary Syndromes (H Jneid, Section Editor)

Readmission After ACS: Burden, Epidemiology, and Mitigation

Diabetes and Cardiovascular Disease (D Bruemmer, Section Editor)

Exercise and Self-Management in Adults with Type 1 Diabetes

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.