Erschienen in: BMC Oral Health 1/2024

Open Access 01.12.2024 | Research

The effect of deviations in sintering temperature on the translucency and color of multi-layered zirconia

verfasst von: Fan Yang, Luyao Zhang, Minghui Yang, Jianfeng Chen, Wenzhong Xing

Erschienen in: BMC Oral Health | Ausgabe 1/2024

Abstract

Object

This study aimed to investigate the changes in the translucency and color of four different multi-layered zirconia materials when the sintering temperature were inaccurate.

Materials and methods

Two hundred zirconia samples (11 × 11 × 1.0 mm) of four multi-layered zirconia, Upcera TT-GT (UG), Upcera TT-ML (UM), Cercon xt ML (CX), and Lava Esthetic (LE), were divided into five subgroups according to the sintering temperature: L1 (5% lower temperature), L2 (2.5% lower temperature), R (recommended sintering temperature), H2 (2.5% higher temperature), H1 (5% higher temperature). After sintering, color coordinates were measured. Then the translucency parameter (TP) values, and the color differences (between the inaccurate sintering temperature and the recommended temperature) of each zirconia specimen were calculated. Statistical analysis was performed by using three-way ANOVA tests, the one-way ANOVA, and Tukey’s post hoc test.

Results

Three-way ANOVA results showed that material type, sintering temperature, specimen section, and their interactions significantly influenced the TP values (except for the interactions of specimen section and sintering temperature) (P < .05). TP values of zirconia specimens were significantly different in the inaccurate sintering temperatures (P < .05), except for the cervical and body sections of UG group (P > .05). Compared with recommended sintering temperature, higher sintering temperature caused higher TP values for CX, but lower for LE. Three-way ANOVA results showed that material type, sintering temperature, and their interactions significantly influenced the ∆E00 values (P < .05). There were no significant differences in ∆E00 values of UM and CX groups at different inaccurate sintering temperatures, and were clinical imperception (except for UM-L1) (∆E00 < 1.25). ∆E00 values of all zirconia specimens showed clinically acceptable (∆E00 < 2.23).

Conclusion

The deviations in sintering temperature significantly influenced the translucency and color of tested multi-layered zirconia. The trends of translucency in the multi-layered zirconia depended on material type and the color changes of all zirconia materials were clinically acceptable at inaccurate sintering temperatures.
Hinweise
Fan Yang and Luyao Zhang contributed equally to this work.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Background

Zirconia restorations were popularly applied in prosthetic clinics due to their promising biocompatibility, chemical resistance and exceptional mechanical properties. However, the esthetic restoration of zirconia ceramics has always been a challenge due to their white opaque appearance [1].
Zirconia is a polycrystalline material that exists in nature in three forms: monoclinic (m-phase), tetragonal (t-phase), and cubic (c-phase). Among these forms, the c-phase is optically isotropic and no-birefringent, leading to greater light transmission and consequently increased translucency [2]. Y2O3 is the widely used stabilizing oxide to make zirconia stabilize to c-phase at room temperature [3]. Higher yttria content (4–6 mol%) increases the content of cubic phase in zirconia, improving the translucency of the zirconia material [2].
At present, the ultra-translucent zirconia materials with 5 mol% yttria content (5Y-PSZ, 5 mol% yttria-partially stabilized zirconia) are used for restoration in the anterior regions. The cubic phase becomes the main phase of 5Y-PSZ, thus exhibiting similar translucency to lithium-disilicate, which is very good in esthetic and is stronger than glass ceramic [3, 4]. In particular, multi-layered zirconia systems have been developed to further improve the esthetic properties of dental restorations and mimic the shade gradient like natural teeth. Multi-layered zirconia presents an incisal section like enamel, a body section like dentin, and a cervical section with a masking effect, thus becoming a possible restoration solution, especially in anterior regions [5].
To realize optimal restoration results, zirconia ceramic is colored by adding pigments to zirconia powder or immersing the uncolored zirconia in coloring liquids [6]. According to the instruction of the manufacturer, in multi-layered zirconia, the gradient color outcome is achieved by adding a small amount of shading elements (e.g. iron and rare earth elements) to the white zirconia base material, gradually increased from the incisal section to the cervical section. After sintering, these elements are built into the zirconia crystals and provide the desired gradient shade effect.
The translucency and color of zirconia materials are crucial keys to achieving a natural character, simulating the appearance of natural tooth structure for restorations, and selecting material, especially in esthetic regions [7, 8]. Translucency Parameter (TP) and the color difference (∆E00) have been proven to be reliable indicators of optical properties of zirconia [9, 10]. The optical properties of zirconia restoration are influenced by several factors, such as the original shade of zirconia ceramics or stains [11], the thickness, microstructure [12] and sintering process [13]. Furthermore, the microstructure and crystalline content of zirconia is determined by the sintering procedure and temperature [8, 12, 14]. Particularly, sintering temperature is a crucial parameter, directly impacting the growth of zirconia particles, grain size, sintered density and porosity [14, 15]. So it is crucial to maintain the sintering temperature under control. Haag et al. [16] measured the actual sintering temperature of 20 commercial dental furnaces to identify the accuracy of sintering temperatures in dental furnaces. The results showed that there was always an inaccuracy of +/−5% between the setting temperature and the actual temperature varied from the furnace brands and conditions [16]. A previous study found that 5% deviations from the recommended sintering temperature influenced the transmittance of zirconia with different yttria content [17]. Nevertheless, there were limited researches on the effect of the inaccuracy sintering temperature on the translucency and color of different brands of multi-layered zirconia material.
The purpose of this study was to investigate the effect of 2.5% and 5% sintering temperature deviations compared to recommended sintering temperatures on the translucency and color of different multi-layered zirconia. The null hypothesis was that sintering temperature deviations would not affect the optical properties of different multi-layered zirconia.

Materials and methods

Fabrication of specimens

The disk-shaped samples (200 pieces at 14 × 14 × 1.3 mm) were produced from four multi-layered zirconia (UG: Upcera TT-GT, UM: Upcera TT-ML, CX: Cercon xt ML, LE: Lava™ Esthetic Fluorescent Full-Contour Zirconia) in A2 shade (Table 1). All samples were prepared by using a low-speed diamond cutter and diamond saw blades (SYJ-150, Shenyang Kejing Automation Equipment Co Ltd., Shenyang, China) under dry conditions, then finely ground with 600 grits of sandpapers (3M ESPE, St. Paul, MN, USA) to the final dimensions.
Table 1
Code, manufacturers, composition and lot numbers of materials used
Material
Code
Manufacturer
Composition
Lot Number
TT-GT, A2
UG
Upcera Dental Technology, Shenzhen, China
ZrO2 + HfO2 + Y2O3 > 96.5%; 5.8-9.7%Y2O3; Al2O3 < 0.5%, Fe2O3 < 0.5%, Er2O3 < 2.0%, Other oxides < 0.5%
-
TT-ML, A2
UM
Upcera Dental Technology, Shenzhen, China
ZrO2 + HfO2 + Y2O3 > 96.5%; 5.8-9.7%Y2O3; Al2O3 < 0.5%, Fe2O3 < 0.5%, Er2O3 < 2.0%, Other oxides < 0.5%
-
Cercon xt ML, A2
CX
Dentsply Sirona, Charlotte, NC, USA
ZrO2; 9%Y2O3; HfO2 < 3%; Al2O3, SiO2, other oxides < 2%
18044511
Lava™ Esthetic Fluorescent Full-Contour Zirconia, A2
LE
3M, St. Paul, MN, USA
ZrO2; 5 mol% Y2O3
7484966

Sintering process

Fifty discs of each material were divided into five groups (n = 10) according to the sintering temperatures. All the specimens were sintered with the furnace (inLab Profire, Dentsply Sirona, Bensheim, Germany) according to their sintering protocols respectively. Five different temperatures (H1, H2, R, L2, L1) were carried out in the sintering protocols of each material. H1: 5% higher than recommended temperature, H2: 2.5% higher than recommended temperature, R: manufacturer’s recommended sintering temperature, L2: 2.5% lower than recommended temperature, L1: 5% lower than recommended temperature. The temperatures for CX and LE groups (H1: 1575 °C H2: 1535 °C R: 1500 °C L2: 1465 °C L1: 1425 °C) were higher than UG (H1: 1555 °C H2: 1515 °C R: 1480 °C L2: 1445 °C L1: 1405 °C) and UM groups (H1: 1522 °C H2: 1486 °C R: 1450 °C L2: 1420 °C L1: 1375 °C). A block of temperature measurement (Referthermo, Japan Fine Ceramics Center, Nagoya, Japan) was placed in the furnace in each sintering protocol to ensure the actual sintering temperature inside the furnace. The setting and actual temperatures for each sintering protocol are given in Table 2.
Table 2
The temperature of setting and actual in the sintering furnace respectively
Material
 
Sintering temperature (°C)
H1
H2
R
L2
L1
UG
ST
1555
1515
1480
1445
1405
AT
1545
1505
1470
1443
1407
UM
ST
1522
1486
1450
1420
1375
AT
1512
1478
1447
1424
1387
CX and LE
ST
1575
1535
1500
1465
1425
AT
1569
1526
1494
1461
1427
*ST means setting temperature, and AT means the actual temperature in furnace
UG and UM groups were started at room temperature, sintered at the rate of 8 °C per minute heating to 1150 °C holding for 30 min. Then heated to 1300 °C at the rate of 2 °C per minute, and subsequently, sintered to maximum temperature at the rate of 4 °C per minute and held for 120 min. After that, cooled them at the rate of 8 °C per minute to 800 °C, finally cooled naturally to room temperature.
CX group was started at room temperature, heated at the rate of 3 °C per minute to 500 °C, then heated to 1200 °C at the rate of 8 °C per minute, and held for 30 min, then heated to 1300 °C at the rate of 2 °C per minute. Subsequently, heated them to the maximum temperature at the rate of 4 °C per minute holding 120 min. After that, cooled them at the rate of 8 °C per minute to 800 °C, finally cooled naturally to room temperature.
LE group was started at room temperature, with a 22 °C per minute rate heated to 800 °C, then heated to maximum temperature at the rate of 10 °C per minute. After 120-minute step time, the temperature was decreased to 800 °C at a 15 °C per minute cooling rate, finally cooled to 250 °C at a rate of 20 °C per minute.
After sintering programs, the sample surfaces of color measurement were serially polished using 800, 1200, 1500, 2000, and 4000 grits sandpapers to achieve the ideal smooth surface. The final dimensions (11 × 11 × 1.0 ± 0.02 mm) of sintered specimens were measured with a digital micrometer (Mitutoyo Corp, Kawasaki, Japan) after ultrasonically cleaning in distilled water for 10 min.

Processing of composite resin background disks

Light-curing resin of A2 shade (Z350XT, Dentine, 3M ESPE, St Paul, MN, USA) was filled in silicon rubber (Silagum Putty Soft, DMG, Hamburg, Germany) mold (14 mm×14 mm×4.5 mm) and pressed with a glass plate to ensure a flat surface. Then cured using a light-polymerizing unit (Mini LED, Satelec, Merignac, France) for 40 s on both sides. The color measurement surface of composite resin was polished with 600 grit wet silicon-carbide paper, adjusting the thickness at 4.0 ± 0.02 mm.

Color measurement

The CIE L*a*b* (L*, brightness; a*, red-green value; and b*, yellow-blue value) values of zirconia specimens were measured using a spectrophotometer (Crystaleye, Olympus, Tokyo, Japan) which used 7 light-emitting diodes (LEDs) as the illumination source with 45/0-degree geometry [18]. For each sample, three measurements were taken and their average was recorded. Translucency was determined by measuring CIE L*a*b* values for all samples against a standard white background (CIE L*=90.33 a*=-0.53 b*=0.79) and black background (CIE L*=20.53 a*=-0.74 b*=-1.00). Then, specimens were placed over the A2 shade composite resin background (CIE L*=74.28 a*=1.54 b*=18.82) to measure their CIE L*a*b* values. Distilled water was put between the zirconia specimen and the background to acquire optical contact during the measurement process. The color difference (∆E00) was determined between the specimens sintered at recommended temperature and inaccurate temperature. All measurements were made on the cervical, body, and incisal areas of each specimen, and after three measurements, recording the average.

Translucency, color difference and chroma calculation

The TP values were determined with the following formula:
TP = [(L*B - L*W)2 + (a*B - a*W)2 + (b*B - b*W)2]1/2
L*, a* and b* refers to brightness, red-green, and yellow-blue coordinates [19]. Where B and W are the color coordinates over a standard black and white backing. The TP value ranges from 0 to 100, with lower values indicating materials with lower translucency and higher values indicating materials with higher translucency.
The chroma of specimens was calculated with the following formula:
C*ab = (a*2 + b*2)1/2
The color differences (∆E00) were calculated based on the following formula:
$$\begin{array}{l}\Delta {E_{{\bf{00}}}} = \\\sqrt {{{\left( {\frac{{\Delta {\bf{L}}\prime }}{{{K_L}{S_L}}}} \right)}^2} + {{\left( {\frac{{\Delta {\bf{C}}\prime }}{{{K_C}{S_C}}}} \right)}^2} + {{\left( {\frac{{\Delta {\bf{H}}\prime }}{{{K_H}{S_H}}}} \right)}^2} + {R_T}\left( {\frac{{\Delta {\bf{C}}\prime }}{{{K_C}{S_C}}}} \right)\left( {\frac{{\Delta {\bf{H}}\prime }}{{{K_H}{S_H}}}} \right)} \end{array}$$
Where ΔL', ΔC' and ΔH' represent the differences in lightness, chroma and hue between the two specimens respectively; SL, SC, and SH are weighting functions that adjust the total color difference based on changes in the position of the color difference pair in the L*, a* and b* coordinates; KL, KC and KH are parameter factors, and were entirely set to 1 in this experiment [20]. Mean ∆E00 values below 1.25 were assumed “clinically imperceptible”, while mean ∆E00 values above 2.23 were assumed “clinically unacceptable” [21].

Statistical analysis

The data analysis was performed by using a statistical software program (IBM SPSS Statistics, v25.0; IBM Corp., Armonk, NY, USA). Three-way and One-way ANOVAs were performed to analyze the effect of sintering temperature, the material type, and specimen section on the translucency and color difference followed by the Tukey post hoc tests [22] at a significance level of P < .05.

Results

According to the setting temperature, the actual sintering temperatures were shown in Table 2.

Variations in TP values at different sintering temperatures

The three-way ANOVA test showed that material type, sintering temperature, specimen section, and their interactions significantly influenced the TP values (except for the interactions of specimen section and sintering temperature) (P < .05) (Table 3).
Table 3
Three-way ANOVA analysis of variance of translucency parameter results
Source
Type III Sum of Squares
df
Mean Square
F
P
material type
2137.424
3
712.475
1279.801
< 0.001*
sintering temperature
278.705
4
69.676
125.158
< 0.001*
specimen section
61.666
2
30.833
55.384
< 0.001*
material type×sintering temperature
1426.806
12
118.901
213.578
< 0.001*
material type×specimen section
222.362
6
37.06
66.57
< 0.001*
sintering temperature×specimen section
7.842
8
0.98
1.761
0.082
material type×sintering temperature×specimen section
24.069
24
1.003
1.801
0.012*
Error
300.622
540
0.557
 
Total
458638.080
600
 
Corrected total
4459.496
599
 
*Statistically significant difference at P < .05
One-way ANOVA results showed that sintering temperature significantly affected the TP values of specimens except for the cervical and body sections of UG group (P < .05) (Table 4). When the sintering temperature was higher than recommended, there were no significant differences in TP values of zirconia specimens in each group except for the body and incisal sections of CX group, the incisal section of UM group, and all sections in LE group. When the sintering temperature was lower than recommended temperature, there were no significant differences in TP values of zirconia specimens in each group except for the whole UM group and the incisal sections of UG, CX and LE groups. The translucency of the three sections of LE and UM group decreased obviously when the sintering temperature was H1 and L1, respectively. TP values were similar in UG group or UM group when the sintering temperature was H1, H2 and R (Fig. 1).
Table 4
Mean and SD values of translucency of materials in three sections at different sintering temperatures
Material
Section
Sintering temperature
F
P
H1
H2
R
L2
L1
UG
Cervical
26.91 ± 0.66
26.65 ± 0.36
26.82 ± 0.75B
27.07 ± 0.85
26.60 ± 0.32
0.947
0.446
Body
27.80 ± 0.48
27.95 ± 0.26
27.76 ± 0.68A
28.39 ± 0.90
27.93 ± 0.52
1.678
0.172
Incisal
27.93 ± 0.63b
28.42 ± 0.52b
28.42 ± 0.64A,b
29.62 ± 0.63a
28.55 ± 0.61b
10.584
< 0.001
UM
Cervical
31.44 ± 0.49a
31.44 ± 0.52a
31.39 ± 0.74A,a
30.45 ± 0.76b
25.09 ± 1.01c
142.966
< 0.001
Body
31.94 ± 0.52a
31.60 ± 0.62a
31.33 ± 0.56A,a
30.38 ± 0.80b
24.97 ± 0.87c
177.074
< 0.001
Incisal
31.81 ± 0.71a
31.22 ± 0.77a,b
30.51 ± 0.76B,b,c
29.75 ± 0.79c
23.13 ± 0.78d
213.791
< 0.001
CX
Cervical
29.48 ± 0.95a
28.63 ± 0.85a,b
28.46 ± 0.95A,a,b
29.00 ± 1.09a,b
28.15 ± 0.80b
3.020
0.027
Body
29.43 ± 0.90a
28.28 ± 0.86b
28.04 ± 0.77A,b
28.34 ± 0.68b
27.82 ± 0.80b
5.953
0.001
Incisal
28.10 ± 0.72a
26.51 ± 0.94c
26.82 ± 0.59B,b
26.81 ± 0.98b
25.67 ± 1.08c
9.888
< 0.001
LE
Cervical
22.02 ± 1.06c
24.68 ± 0.93b
26.53 ± 0.43A,a
26.87 ± 0.62a
26.46 ± 0.60a
70.769
< 0.001
Body
21.30 ± 0.97c
23.65 ± 0.71b
25.85 ± 0.47A,a
26.48 ± 0.67a
26.17 ± 0.51a
102.171
< 0.001
Incisal
20.34 ± 0.94d
22.92 ± 0.76c
24.40 ± 0.99B,b
25.44 ± 0.45a
24.84 ± 0.67a,b
67.390
< 0.001
*Groups with different superscript lower case letters (a, b) have significant differences in row (Tukey’s test). Groups with different superscript upper case letters (A, B) have significant differences in column (Tukey’s test)
When UM, CX and LE groups were sintered at recommended sintering temperature, TP values of tested zirconia specimens showed a decreasing tendency from the cervical to the incisal section, and there were no significant differences between cervical and body sections (P > .05). TP values of UG group showed an increasing tendency from the cervical to incisal section, and there was no significant difference in body and incisal sections of UG group (P > .05) (Table 4).

Variations in ∆E00 values at different sintering temperatures

The three-way ANOVA test showed that material types, sintering temperatures, and their interactions significantly influenced the ∆E00 values (P < .05) (Table 5). The interactions of material type and specimen section significantly affected the ∆E00 values (P < .05), and the specimen section did not (P > .05) (Table 5).
Table 5
Three-way ANOVA analysis of variance of color difference between inaccuracy temperatures and recommended sintering temperature
Source
Type III Sum of Squares
df
Mean Square
F
P
material type
8.956
3
2.985
12.884
< 0.001*
sintering temperature
26.282
3
8.761
37.807
< 0.001*
specimen section
0.121
2
0.060
0.260
0.771
material type×sintering temperature
28.310
9
3.146
13.574
< 0.001*
material type×specimen section
3.611
6
0.602
2.597
0.018*
sintering temperature×specimen section
0.267
6
0.044
0.192
0.979
material type ×sintering temperature×specimen section
3.698
18
0.205
0.886
0.596
Error
100.106
432
0.232
  
Total
775.204
480
   
Corrected total
171.351
479
   
*Statistically significant difference at P < .05
The results of one-way ANOVA showed that sintering temperatures significantly affected the ∆E00 values of specimens (except for UM and CX groups) (P < .05). ∆E00 values of all tested specimens sintered between R and other inaccurate temperatures varied from 0.57 to 2.18, which were clinically acceptable (∆E00 < 2.23) (Table 6). ∆E00 values of UG group (except ∆E00 R−L2 in incisal section and ∆E00 R−H2 in all sections), and ∆E00 R−H1 of LE group in all sections were above the perceptibility threshold (∆E00 > 1.25). ∆E00 values of CX and UM groups (except ∆E00 R−L1 of UM group in incisal section) were all below the limit of perceptibility threshold (Fig. 2).
Table 6
Mean and SD values of color difference of zirconia materials in three sections
Material
Section
Sintering temperature
F
P
E00 R−H1
E00 R−H2
E00 R−L2
E00 R−L1
UG
Cervical
1.79 ± 0.28a
0.83 ± 0.30b
1.53 ± 0.71a
1.77 ± 0.40a
9.811
< 0.001
Body
1.54 ± 0.25a
0.63 ± 0.29b
1.41 ± 0.62a
1.78 ± 0.23a
17.348
< 0.001
Incisal
1.56 ± 0.31a
0.57 ± 0.15b
0.97 ± 0.47b
1.45 ± 0.37a
17.618
< 0.001
UM
Cervical
1.07 ± 0.48
0.82 ± 0.82
1.06 ± 0.39
1.19 ± 0.28
0.823
0.490
Body
0.96 ± 0.32
0.63 ± 0.50
1.11 ± 0.42
1.07 ± 0.39
2.759
0.056
Incisal
1.01 ± 0.59
0.70 ± 0.31
1.03 ± 0.63
1.46 ± 0.97
2.197
0.105
CX
Cervical
0.87 ± 0.35
1.00 ± 0.46A
0.97 ± 0.55
1.13 ± 0.44
0.561
0.644
Body
0.85 ± 0.35
0.71 ± 0.31A,B
1.03 ± 0.47
1.21 ± 0.63
2.342
0.089
Incisal
1.10 ± 0.52
0.59 ± 0.27B
1.23 ± 0.71
1.08 ± 0.68
2.386
0.085
LE
Cervical
1.90 ± 0.44a
0.72 ± 0.27b
0.62 ± 0.24b
0.97 ± 0.32b
31.806
< 0.001
Body
2.18 ± 0.49a
1.13 ± 0.40b
0.77 ± 0.49b
0.99 ± 0.50b
17.633
< 0.001
Incisal
1.95 ± 0.78a
1.04 ± 0.53b
0.82 ± 0.52b
1.07 ± 0.44b
7.293
0.001
*Groups with different superscript lower case letters (a, b) have significant differences in row (Tukey’s test). Groups with different superscript upper case letters (A, B) have significant differences in column (Tukey’s test)

Variations in L* and C*ab values at different sintering temperatures

Distributions of the L* and C*ab values of zirconia specimens in different sintering temperatures were presented in Fig. 3. L* values decreased in UG group and increased in the incisal section of UM group with the sintering temperature reducing (Fig. 3a, c). When the sintering temperature was 5% higher than recommended, the L* values of UG and LE groups increased. The C*ab values of all specimens decreased when the sintering temperature was higher than recommended. C*ab values increased from the incisal to cervical section, and L* values were minor changes.

Discussion

The null hypothesis was rejected because the results of this study revealed that the translucency and color difference were influenced by sintering temperature deviations.
Sintering procedures directly affects the grain size, porosity, yttria distribution and the content of the cubic phase in zirconia specimens [14, 23]. In the current study, the variations in sintering temperature caused the different tendencies of translucency change in zirconia specimens. TP values of CX (except for cervical section) and the incisal section of UM groups specimens sintered at H1 were higher than those sintered at R. This finding was in line with other previous studies in which the TP values of zirconia materials increased with the sintering temperature increased [14, 24, 25]. The phenomenon could be attributed to the fact that higher sintering temperature increases the grain size, reduces the grain boundary density and refraction, thus increasing the translucency of zirconia [8]. On the contrary, TP values of LE group significantly decreased at H1 and H2 temperatures compared with the recommended sintering temperature. Attachoo et al. [25] reported that the translucency of zirconia (Ceramill® Zolid classic) decreased when the sintering temperature (1550 °C) was higher than regular temperature (1350 °C). This result may be associated with the microcrack nucleation in grain boundary, which adversely affecting the light scattering.
The TP values decreased when the sintering temperature was lower than recommended temperature, zirconia became opaque. Especially in UM group, TP values of specimens sintered at L1 and L2 were significantly lower than those sintered at R. Similar results were found by Vult et al. [17], who investigated the effect of 5% sintering temperature deviations on the optical properties of zirconia with different yttria content. They observed that the transmittance values of tested zirconia (3YSB-E®, 3YSBC® and Zpex®smile, colorless) sintered at TL (5% lower than recommended) were lower than at TR (recommended sintering temperature) and TH (5% higher than recommended). Lower sintering temperature led to reduced grain size and increased grain boundary, which therefore influenced the light scattering and diminished the translucency of zirconia [8, 17].
The multi-layered zirconia has a layered structure designed to mimic the color gradient observed in natural teeth. In the present study, UM, CX and LE groups showed a slight decrease in translucency from the cervical to incisal section, while UG group showed an increased tendency. The results were consistent with the results of Uasuwan et al. [26], who found Cercon xt ML in A2 shade showed a slight decrease in TP values from the cervical to incisal section. This could make the incisal section less impacted by the oral black background and improve shade reproducibility in multi-layered zirconia restorations. Based on the results of the color parameters, except for CX group, the cervical section showed the least brightness compared with the body and incisal sections in other groups. The distributions of C*ab showed an obvious decreased tendency from the cervical to incisal section in the chromatic of zirconia specimens [27]. However, there is no difference in the tetragonal, cubic phase content and grain size in each layer [5]. The optical properties of different layers were probably attributed to the zirconia composition and the discrepancy in pigmentation among different layers [27, 28].
The deviations in sintering temperature had different effects on the color results of multi-layered zirconia, but they were all clinically acceptable (∆E00 < 2.23), regardless of sintering temperature deviations and specimen sections. Cardoso et al. [29] compared the optical properties of Prettau Anterior zirconia sintered at 1450 °C and 1600 °C temperatures, and observed that the color difference was perceptible but acceptable (0.81 <∆E00 < 1.77). In the present study, the ∆E00 of UG group (except for ∆E00 R−H2, and ∆E00 R−L2 in incisal section), ∆E00 R−L1 of UM group in incisal section and ∆E00 R−H1 of LE group were clinical perceptible (∆E00 > 1.25). This was because higher and lower sintering temperatures would influence the sintered density of zirconia specimens, leading to the changes in pores and crystal arrangement. The changes in the light transmission and reflection ultimately influence the color results of zirconia [30]. Thus, the deviations in sintering temperature greatly affected the color outcome of UG group. Higher sintering temperature (H1) led to significant color changes in LE group.
The color parameters of zirconia specimens were influenced by inaccurate sintering temperatures. When the sintering temperature was inaccurate, the tendency of C*ab values of all specimens was the same irrespective of material type, while the tendency of L* values varied depending on material type. As the sintering temperature decreased, all zirconia specimens increased in chroma, and the brightness increased in the incisal sections of UM group, while decreasing in UG group.
The limitations of this study were that the zirconia samples were flat, and the multi-layered zirconia samples tested in the study had similar yttria content with only 1 shade (A2). Furthermore, surface roughness, X-ray diffractometry, and elemental analysis of the zirconia specimens at inaccurate sintering temperatures were not conducted in the present study. Future research should consider combining the mentioned factors that can affect the optical and mechanical properties of multi-layered zirconia materials.

Conclusion

Based on the settings and the results, this study indicated that the deviations in sintering temperature influenced the translucency and color of tested multi-layered zirconia, which mainly depended on the types of multi-layered zirconia. The inaccurate sintering temperatures led to different trends of translucency in different types of multi-layered zirconia. Too low sintering temperature (L1) led to a significant reduction in translucency. The deviations in sintering temperature greatly influenced the color outcome of some zirconia materials, while the color results of all zirconia materials were clinically acceptable.

Acknowledgements

Not applicable.

Declarations

Not applicable.
Not applicable.

Competing interests

The authors declare no competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Ilie N, Stawarczyk B. Quantification of the amount of light passing through zirconia: the effect of material shade, thickness, and curing conditions. J Dent. 2014;42:684–90.CrossRefPubMed Ilie N, Stawarczyk B. Quantification of the amount of light passing through zirconia: the effect of material shade, thickness, and curing conditions. J Dent. 2014;42:684–90.CrossRefPubMed
2.
Zurück zum Zitat Denry I, Kelly JR. State of the art of zirconia for dental applications. Dent Mater. 2008;24:299–307.CrossRefPubMed Denry I, Kelly JR. State of the art of zirconia for dental applications. Dent Mater. 2008;24:299–307.CrossRefPubMed
3.
4.
Zurück zum Zitat de Araújo-Júnior ENS, Bergamo ETP, Bastos TMC, Benalcázar Jalkh EB, Lopes ACO, Monteiro KN, et al. Ultra-translucent zirconia processing and aging effect on microstructural, optical, and mechanical properties. Dent Mater. 2022;38:587–600.CrossRefPubMed de Araújo-Júnior ENS, Bergamo ETP, Bastos TMC, Benalcázar Jalkh EB, Lopes ACO, Monteiro KN, et al. Ultra-translucent zirconia processing and aging effect on microstructural, optical, and mechanical properties. Dent Mater. 2022;38:587–600.CrossRefPubMed
5.
Zurück zum Zitat Kolakarnprasert N, Kaizer MR, Kim DK, Zhang Y. New multi-layered zirconias: composition, microstructure and translucency. Dent Mater. 2019;35:797–806.CrossRefPubMedPubMedCentral Kolakarnprasert N, Kaizer MR, Kim DK, Zhang Y. New multi-layered zirconias: composition, microstructure and translucency. Dent Mater. 2019;35:797–806.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Kim HK, Kim SH. Optical properties of pre-colored dental monolithic zirconia ceramics. J Dent. 2016;55:75–81.CrossRefPubMed Kim HK, Kim SH. Optical properties of pre-colored dental monolithic zirconia ceramics. J Dent. 2016;55:75–81.CrossRefPubMed
7.
Zurück zum Zitat Alp G, Subaşı MG, Seghi RR, Johnston WM, Yilmaz B. Effect of shading technique and thickness on color stability and translucency of new generation translucent zirconia. J Dent. 2018;73:19–23.CrossRefPubMed Alp G, Subaşı MG, Seghi RR, Johnston WM, Yilmaz B. Effect of shading technique and thickness on color stability and translucency of new generation translucent zirconia. J Dent. 2018;73:19–23.CrossRefPubMed
9.
Zurück zum Zitat Johnston WM. Review of translucency determinations and applications to dental materials. J Esthet Restor Dent. 2014;26:217–23.CrossRefPubMed Johnston WM. Review of translucency determinations and applications to dental materials. J Esthet Restor Dent. 2014;26:217–23.CrossRefPubMed
10.
Zurück zum Zitat Gómez-Polo C, Portillo Muñoz M, Lorenzo Luengo MC, Vicente P, Galindo P, Martín Casado AM. Comparison of the CIELab and CIEDE2000 color difference formulas. J Prosthet Dent. 2016;115:65–70.CrossRefPubMed Gómez-Polo C, Portillo Muñoz M, Lorenzo Luengo MC, Vicente P, Galindo P, Martín Casado AM. Comparison of the CIELab and CIEDE2000 color difference formulas. J Prosthet Dent. 2016;115:65–70.CrossRefPubMed
11.
Zurück zum Zitat Sasany R, Yilmaz B. Effect of stain brand and shade on color stability of stains applied on a CAD-CAM feldspathic ceramic. Odontology. 2022;110:452–59.CrossRefPubMed Sasany R, Yilmaz B. Effect of stain brand and shade on color stability of stains applied on a CAD-CAM feldspathic ceramic. Odontology. 2022;110:452–59.CrossRefPubMed
12.
Zurück zum Zitat Sen N, Isler S. Microstructural, physical, and optical characterization of high-translucency zirconia ceramics. J Prosthet Dent. 2020;123:761–68.CrossRefPubMed Sen N, Isler S. Microstructural, physical, and optical characterization of high-translucency zirconia ceramics. J Prosthet Dent. 2020;123:761–68.CrossRefPubMed
13.
Zurück zum Zitat Tabatabaian F. Color aspect of monolithic Zirconia restorations: a review of the literature. J Prosthodont. 2019;28:276–87.CrossRefPubMed Tabatabaian F. Color aspect of monolithic Zirconia restorations: a review of the literature. J Prosthodont. 2019;28:276–87.CrossRefPubMed
14.
Zurück zum Zitat Stawarczyk B, Ozcan M, Hallmann L, Ender A, Mehl A, Hammerlet CHF. The effect of zirconia sintering temperature on flexural strength, grain size, and contrast ratio. Clin Oral Investig. 2013;17:269–74.CrossRefPubMed Stawarczyk B, Ozcan M, Hallmann L, Ender A, Mehl A, Hammerlet CHF. The effect of zirconia sintering temperature on flexural strength, grain size, and contrast ratio. Clin Oral Investig. 2013;17:269–74.CrossRefPubMed
15.
Zurück zum Zitat Yousry MA, Hammad IA, El Halawani MT, Aboushelib MN. Effect of sintering time on microstructure and optical properties of yttria-partially stabilized monolithic zirconia. Dent Mater. 2023;39:1169–79.CrossRefPubMed Yousry MA, Hammad IA, El Halawani MT, Aboushelib MN. Effect of sintering time on microstructure and optical properties of yttria-partially stabilized monolithic zirconia. Dent Mater. 2023;39:1169–79.CrossRefPubMed
16.
Zurück zum Zitat Haag P, Ciber E, Dérand T. Firing temperature accuracy of four dental furnaces. Swed Dent J. 2011;35:25–31.PubMed Haag P, Ciber E, Dérand T. Firing temperature accuracy of four dental furnaces. Swed Dent J. 2011;35:25–31.PubMed
17.
Zurück zum Zitat Vult von Steyern P, Bruzell E, Vos L, Andersen FS, Ruud A. Sintering temperature accuracy and its effect on translucent yttria-stabilized zirconia: flexural strength, crystal structure, tetragonality and light transmission. Dent Mater. 2022;38:1099–107.CrossRefPubMed Vult von Steyern P, Bruzell E, Vos L, Andersen FS, Ruud A. Sintering temperature accuracy and its effect on translucent yttria-stabilized zirconia: flexural strength, crystal structure, tetragonality and light transmission. Dent Mater. 2022;38:1099–107.CrossRefPubMed
18.
Zurück zum Zitat Odaira C, Itoh S, Ishibashi K. Clinical evaluation of a dental color analysis system: the Crystaleye Spectrophotometer®. J Prosthodont Res. 2011;55:199–205.CrossRefPubMed Odaira C, Itoh S, Ishibashi K. Clinical evaluation of a dental color analysis system: the Crystaleye Spectrophotometer®. J Prosthodont Res. 2011;55:199–205.CrossRefPubMed
19.
Zurück zum Zitat Johnston WM, Ma T, Kienle BH. Translucency parameter of colorants for maxillofacial prostheses. Int J Prosthodont. 1995;8:79–86.PubMed Johnston WM, Ma T, Kienle BH. Translucency parameter of colorants for maxillofacial prostheses. Int J Prosthodont. 1995;8:79–86.PubMed
20.
Zurück zum Zitat Lee YK. Comparison of CIELAB DeltaE(*) and CIEDE2000 color-differences after polymerization and thermocycling of resin composites. Dent Mater. 2005;21:678–82.CrossRefPubMed Lee YK. Comparison of CIELAB DeltaE(*) and CIEDE2000 color-differences after polymerization and thermocycling of resin composites. Dent Mater. 2005;21:678–82.CrossRefPubMed
21.
Zurück zum Zitat Ghinea R, Pérez MM, Herrera LJ, Rivas MJ, Yebra A, Paravina RD. Color difference thresholds in dental ceramics. J Dent. 2010;38(Suppl 2):e57–64.CrossRefPubMed Ghinea R, Pérez MM, Herrera LJ, Rivas MJ, Yebra A, Paravina RD. Color difference thresholds in dental ceramics. J Dent. 2010;38(Suppl 2):e57–64.CrossRefPubMed
22.
Zurück zum Zitat Juntavee N, Attashu S. Effect of sintering process on color parameters of nano-sized yttria partially stabilized tetragonal monolithic zirconia. J Clin Exp Dent. 2018;10:e794–e804.PubMedPubMedCentral Juntavee N, Attashu S. Effect of sintering process on color parameters of nano-sized yttria partially stabilized tetragonal monolithic zirconia. J Clin Exp Dent. 2018;10:e794–e804.PubMedPubMedCentral
24.
Zurück zum Zitat Sen N, Sermet IB, Cinar S. Effect of coloring and sintering on the translucency and biaxial strength of monolithic zirconia. J Prosthet Dent. 2018;119:308.e1–308.e7.CrossRefPubMed Sen N, Sermet IB, Cinar S. Effect of coloring and sintering on the translucency and biaxial strength of monolithic zirconia. J Prosthet Dent. 2018;119:308.e1–308.e7.CrossRefPubMed
25.
Zurück zum Zitat Attachoo S, Juntavee N. Role of sintered temperature and sintering time on spectral translucence of nano-crystal monolithic zirconia. J Clin Exp Dent. 2019;11:e146–53.CrossRefPubMedPubMedCentral Attachoo S, Juntavee N. Role of sintered temperature and sintering time on spectral translucence of nano-crystal monolithic zirconia. J Clin Exp Dent. 2019;11:e146–53.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Uasuwan P, Juntavee N, Juntavee A. Optical characteristics of monochrome and Multilayer fully stabilized Zirconia upon Sintered cooling speed. Eur J Dent. 2024;18:196–207.CrossRefPubMed Uasuwan P, Juntavee N, Juntavee A. Optical characteristics of monochrome and Multilayer fully stabilized Zirconia upon Sintered cooling speed. Eur J Dent. 2024;18:196–207.CrossRefPubMed
27.
Zurück zum Zitat Ueda K, Güth JF, Erdelt K, Stimmelmayr M, Kappert H, Beuer F. Light transmittance by a multi-coloured zirconia material. Dent Mater J. 2015;34:310–14.CrossRefPubMed Ueda K, Güth JF, Erdelt K, Stimmelmayr M, Kappert H, Beuer F. Light transmittance by a multi-coloured zirconia material. Dent Mater J. 2015;34:310–14.CrossRefPubMed
28.
Zurück zum Zitat Schabbach LM, Dos Santos BC, De Bortoli LS, Fabris D, Fredel MC, Henriques B. Translucent multi-layered zirconia: sandblasting effect on optical and mechanical properties. Dent Mater. 2023;39:807–19.CrossRefPubMed Schabbach LM, Dos Santos BC, De Bortoli LS, Fabris D, Fredel MC, Henriques B. Translucent multi-layered zirconia: sandblasting effect on optical and mechanical properties. Dent Mater. 2023;39:807–19.CrossRefPubMed
29.
Zurück zum Zitat Cardoso KV, Adabo GL, Mariscal-Muñoz E, Antonio SG, Arioli Filho JN. Effect of sintering temperature on microstructure, flexural strength, and optical properties of a fully stabilized monolithic zirconia. J Prosthet Dent. 2020;124:594–98.CrossRefPubMed Cardoso KV, Adabo GL, Mariscal-Muñoz E, Antonio SG, Arioli Filho JN. Effect of sintering temperature on microstructure, flexural strength, and optical properties of a fully stabilized monolithic zirconia. J Prosthet Dent. 2020;124:594–98.CrossRefPubMed
30.
Zurück zum Zitat Ebeid K, Wille S, Hamdy A, Salah T, El-Etreby A, Kern M. Effect of changes in sintering parameters on monolithic translucent zirconia. Dent Mater. 2014;30:e419–24.CrossRefPubMed Ebeid K, Wille S, Hamdy A, Salah T, El-Etreby A, Kern M. Effect of changes in sintering parameters on monolithic translucent zirconia. Dent Mater. 2014;30:e419–24.CrossRefPubMed
Metadaten
Titel
The effect of deviations in sintering temperature on the translucency and color of multi-layered zirconia
verfasst von
Fan Yang
Luyao Zhang
Minghui Yang
Jianfeng Chen
Wenzhong Xing
Publikationsdatum
01.12.2024
Verlag
BioMed Central
Erschienen in
BMC Oral Health / Ausgabe 1/2024
Elektronische ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-024-04243-4

Weitere Artikel der Ausgabe 1/2024

BMC Oral Health 1/2024 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.