Skip to main content
Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 5/2017

30.03.2017 | Original Article

Accuracy of stereolithographically printed digital models compared to plaster models

verfasst von: Leonardo Tavares Camardella, Oswaldo V. Vilella, Marleen M. van Hezel, Karel H. Breuning

Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie | Ausgabe 5/2017

Einloggen, um Zugang zu erhalten

Abstract

Objective

This study compared the accuracy of plaster models from alginate impressions and printed models from intraoral scanning.

Materials and methods

A total of 28 volunteers were selected and alginate impressions and intraoral scans were used to make plaster models and digital models of their dentition, respectively. The digital models were printed using a stereolithographic (SLA) 3D printer with a horseshoe-shaped design. Two calibrated examiners measured distances on the plaster and printed models with a digital caliper. The paired t test was used to determine intraobserver error and compare the measurements. The Pearson correlation coefficient was used to evaluate the reliability of measurements for each model type.

Results

The measurements on plaster models and printed models show some significant differences in tooth dimensions and interarch parameters, but these differences were not clinically relevant, except for the transversal measurements. The upper and lower intermolar distances on the printed models were statistically significant and clinically relevant smaller.

Conclusions

Printed digital models with the SLA 3D printer studied, with a horseshoe-shaped base made from intraoral scans cannot replace conventional plaster models from alginate impressions in orthodontics for diagnosis and treatment planning because of their clinically relevant transversal contraction.
Literatur
1.
Zurück zum Zitat Aboul-Hosn Centenero S, Hernandez-Alfaro F (2012) 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results—our experience in 16 cases. J Craniomaxillofac Surg 40:162–168CrossRefPubMed Aboul-Hosn Centenero S, Hernandez-Alfaro F (2012) 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results—our experience in 16 cases. J Craniomaxillofac Surg 40:162–168CrossRefPubMed
2.
Zurück zum Zitat Akyalcin S, Cozad BE, English JD, Colville CD, Laman S (2013) Diagnostic accuracy of impression-free digital models. Am J Orthod Dentofacial Orthop 144:916–922CrossRefPubMed Akyalcin S, Cozad BE, English JD, Colville CD, Laman S (2013) Diagnostic accuracy of impression-free digital models. Am J Orthod Dentofacial Orthop 144:916–922CrossRefPubMed
3.
Zurück zum Zitat Al Mortadi N, Eggbeer D, Lewis J, Williams RJ (2012) CAD/CAM/AM applications in the manufacture of dental appliances. Am J Orthod Dentofacial Orthop 142:727–733CrossRefPubMed Al Mortadi N, Eggbeer D, Lewis J, Williams RJ (2012) CAD/CAM/AM applications in the manufacture of dental appliances. Am J Orthod Dentofacial Orthop 142:727–733CrossRefPubMed
4.
Zurück zum Zitat Asquith J, Gillgrass T, Mossey P (2007) Three-dimensional imaging of orthodontic models: a pilot study. Eur J Orthod 29:517–522CrossRefPubMed Asquith J, Gillgrass T, Mossey P (2007) Three-dimensional imaging of orthodontic models: a pilot study. Eur J Orthod 29:517–522CrossRefPubMed
5.
Zurück zum Zitat Bae MJ, Kim JY, Park JT, Cha JY, Kim HJ, Yu HS et al (2013) Accuracy of miniscrew surgical guides assessed from cone-beam computed tomography and digital models. Am J Orthod Dentofacial Orthop 143:893–901CrossRefPubMed Bae MJ, Kim JY, Park JT, Cha JY, Kim HJ, Yu HS et al (2013) Accuracy of miniscrew surgical guides assessed from cone-beam computed tomography and digital models. Am J Orthod Dentofacial Orthop 143:893–901CrossRefPubMed
6.
Zurück zum Zitat Bootvong K, Liu Z, McGrath C, Hagg U, Wong RW, Bendeus M et al (2010) Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity. Eur J Orthod 32:589–595CrossRefPubMed Bootvong K, Liu Z, McGrath C, Hagg U, Wong RW, Bendeus M et al (2010) Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity. Eur J Orthod 32:589–595CrossRefPubMed
7.
Zurück zum Zitat Choi JY, Choi JH, Kim NK, Kim Y, Lee JK, Kim MK et al (2002) Analysis of errors in medical rapid prototyping models. Int J Oral Maxillofac Surg 31:23–32CrossRefPubMed Choi JY, Choi JH, Kim NK, Kim Y, Lee JK, Kim MK et al (2002) Analysis of errors in medical rapid prototyping models. Int J Oral Maxillofac Surg 31:23–32CrossRefPubMed
8.
Zurück zum Zitat Ciuffolo F, Epifania E, Duranti G, De Luca V, Raviglia D, Rezza S et al (2006) Rapid prototyping: a new method of preparing trays for indirect bonding. Am J Orthod Dentofac Orthop 129:75–77CrossRef Ciuffolo F, Epifania E, Duranti G, De Luca V, Raviglia D, Rezza S et al (2006) Rapid prototyping: a new method of preparing trays for indirect bonding. Am J Orthod Dentofac Orthop 129:75–77CrossRef
9.
Zurück zum Zitat Cuperus AM, Harms MC, Rangel FA, Bronkhorst EM, Schols JG, Breuning KH (2012) Dental models made with an intraoral scanner: a validation study. Am J Orthod Dentofac Orthop 142:308–313CrossRef Cuperus AM, Harms MC, Rangel FA, Bronkhorst EM, Schols JG, Breuning KH (2012) Dental models made with an intraoral scanner: a validation study. Am J Orthod Dentofac Orthop 142:308–313CrossRef
10.
Zurück zum Zitat de Waard O, Rangel FA, Fudalej PS, Bronkhorst EM, Kuijpers-Jagtman AM, Breuning KH (2014) Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts. Am J Orthod Dentofac Orthop 146:328–336CrossRef de Waard O, Rangel FA, Fudalej PS, Bronkhorst EM, Kuijpers-Jagtman AM, Breuning KH (2014) Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts. Am J Orthod Dentofac Orthop 146:328–336CrossRef
11.
Zurück zum Zitat Fleming PS, Marinho V, Johal A (2011) Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthod Craniofac Res 14:1–16CrossRefPubMed Fleming PS, Marinho V, Johal A (2011) Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthod Craniofac Res 14:1–16CrossRefPubMed
12.
Zurück zum Zitat Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC (2013) Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofac Orthop 144:471–478CrossRef Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC (2013) Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofac Orthop 144:471–478CrossRef
13.
Zurück zum Zitat Garino F, Garino GB (2002) Comparison of dental arch measurements between stone and digital casts. World J Orthod 3:250–254 Garino F, Garino GB (2002) Comparison of dental arch measurements between stone and digital casts. World J Orthod 3:250–254
14.
Zurück zum Zitat Gateno J, Xia J, Teichgraeber JF, Rosen A, Hultgren B, Vadnais T (2003) The precision of computer-generated surgical splints. J Oral Maxillofac Surg 61:814–817CrossRefPubMed Gateno J, Xia J, Teichgraeber JF, Rosen A, Hultgren B, Vadnais T (2003) The precision of computer-generated surgical splints. J Oral Maxillofac Surg 61:814–817CrossRefPubMed
15.
Zurück zum Zitat Grunheid T, McCarthy SD, Larson BE (2014) Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance. Am J Orthod Dentofac Orthop 146:673–682CrossRef Grunheid T, McCarthy SD, Larson BE (2014) Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance. Am J Orthod Dentofac Orthop 146:673–682CrossRef
16.
Zurück zum Zitat Grunheid T, Patel N, De Felippe NL, Wey A, Gaillard PR, Larson BE (2014) Accuracy, reproducibility, and time efficiency of dental measurements using different technologies. Am J Orthod Dentofac Orthop 145:157–164CrossRef Grunheid T, Patel N, De Felippe NL, Wey A, Gaillard PR, Larson BE (2014) Accuracy, reproducibility, and time efficiency of dental measurements using different technologies. Am J Orthod Dentofac Orthop 145:157–164CrossRef
17.
Zurück zum Zitat Hazeveld A, Huddleston Slater JJ, Ren Y (2014) Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am J Orthod Dentofac Orthop 145:108–115CrossRef Hazeveld A, Huddleston Slater JJ, Ren Y (2014) Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am J Orthod Dentofac Orthop 145:108–115CrossRef
18.
Zurück zum Zitat Hernandez-Alfaro F, Guijarro-Martinez R (2013) New protocol for three-dimensional surgical planning and CAD/CAM splint generation in orthognathic surgery: an in vitro and in vivo study. Int J Oral Maxillofac Surg 42:1547–1556CrossRefPubMed Hernandez-Alfaro F, Guijarro-Martinez R (2013) New protocol for three-dimensional surgical planning and CAD/CAM splint generation in orthognathic surgery: an in vitro and in vivo study. Int J Oral Maxillofac Surg 42:1547–1556CrossRefPubMed
19.
Zurück zum Zitat Kasparova M, Grafova L, Dvorak P, Dostalova T, Prochazka A, Eliasova H et al (2013) Possibility of reconstruction of dental plaster cast from 3D digital study models. Biomed Eng Online 12:49CrossRefPubMedPubMedCentral Kasparova M, Grafova L, Dvorak P, Dostalova T, Prochazka A, Eliasova H et al (2013) Possibility of reconstruction of dental plaster cast from 3D digital study models. Biomed Eng Online 12:49CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Kau CH, Littlefield J, Rainy N, Nguyen JT, Creed B (2010) Evaluation of CBCT digital models and traditional models using the Little’s index. Angle Orthod 80:435–439CrossRefPubMed Kau CH, Littlefield J, Rainy N, Nguyen JT, Creed B (2010) Evaluation of CBCT digital models and traditional models using the Little’s index. Angle Orthod 80:435–439CrossRefPubMed
21.
Zurück zum Zitat Keating AP, Knox J, Bibb R, Zhurov AI (2008) A comparison of plaster, digital and reconstructed study model accuracy. J Orthod 35:191–201 (Discussion 175)CrossRefPubMed Keating AP, Knox J, Bibb R, Zhurov AI (2008) A comparison of plaster, digital and reconstructed study model accuracy. J Orthod 35:191–201 (Discussion 175)CrossRefPubMed
22.
Zurück zum Zitat Kim J, Heo G, Lagravere MO (2014) Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography. Angle Orthod 84:443–450CrossRefPubMed Kim J, Heo G, Lagravere MO (2014) Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography. Angle Orthod 84:443–450CrossRefPubMed
23.
Zurück zum Zitat Lagravere MO, Flores-Mir C (2005) The treatment effects of Invisalign orthodontic aligners: a systematic review. J Am Dent Assoc 136:1724–1729CrossRefPubMed Lagravere MO, Flores-Mir C (2005) The treatment effects of Invisalign orthodontic aligners: a systematic review. J Am Dent Assoc 136:1724–1729CrossRefPubMed
24.
Zurück zum Zitat Lauren M, McIntyre F (2008) A new computer-assisted method for design and fabrication of occlusal splints. Am J Orthod Dentofac Orthop 133:S130–135CrossRef Lauren M, McIntyre F (2008) A new computer-assisted method for design and fabrication of occlusal splints. Am J Orthod Dentofac Orthop 133:S130–135CrossRef
25.
Zurück zum Zitat Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ (2009) Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofac Orthop 136:16 e1-4 (Discussion 16) Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ (2009) Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofac Orthop 136:16 e1-4 (Discussion 16)
26.
Zurück zum Zitat Mullen SR, Martin CA, Ngan P, Gladwin M (2007) Accuracy of space analysis with emodels and plaster models. Am J Orthod Dentofac Orthop 132:346–352CrossRef Mullen SR, Martin CA, Ngan P, Gladwin M (2007) Accuracy of space analysis with emodels and plaster models. Am J Orthod Dentofac Orthop 132:346–352CrossRef
27.
Zurück zum Zitat Murugesan K, Anandapandian PA, Sharma SK, Vasantha Kumar M (2012) Comparative evaluation of dimension and surface detail accuracy of models produced by three different rapid prototype techniques. J Indian Prosthodont 12:16–20CrossRef Murugesan K, Anandapandian PA, Sharma SK, Vasantha Kumar M (2012) Comparative evaluation of dimension and surface detail accuracy of models produced by three different rapid prototype techniques. J Indian Prosthodont 12:16–20CrossRef
28.
Zurück zum Zitat Naidu D, Freer TJ (2013) Validity, reliability, and reproducibility of the iOC intraoral scanner: a comparison of tooth widths and Bolton ratios. Am J Orthod Dentofac Orthop 144:304–310CrossRef Naidu D, Freer TJ (2013) Validity, reliability, and reproducibility of the iOC intraoral scanner: a comparison of tooth widths and Bolton ratios. Am J Orthod Dentofac Orthop 144:304–310CrossRef
29.
Zurück zum Zitat Pandis N (2012) Sample calculations for comparison of 2 means. Am J Orthod Dentofac Orthop 141:519–521CrossRef Pandis N (2012) Sample calculations for comparison of 2 means. Am J Orthod Dentofac Orthop 141:519–521CrossRef
30.
Zurück zum Zitat Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ (2003) Comparison of measurements made on digital and plaster models. Am J Orthod Dentofac Orthop 124:101–105CrossRef Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ (2003) Comparison of measurements made on digital and plaster models. Am J Orthod Dentofac Orthop 124:101–105CrossRef
31.
Zurück zum Zitat Stevens DR, Flores-Mir C, Nebbe B, Raboud DW, Heo G, Major PW (2006) Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofac Orthop 129:794–803CrossRef Stevens DR, Flores-Mir C, Nebbe B, Raboud DW, Heo G, Major PW (2006) Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofac Orthop 129:794–803CrossRef
32.
Zurück zum Zitat Torabi K, Farjood E, Hamedani S (2015) Rapid prototyping technologies and their applications in prosthodontics, a review of literature. J Dent (Shiraz) 16:1–9 Torabi K, Farjood E, Hamedani S (2015) Rapid prototyping technologies and their applications in prosthodontics, a review of literature. J Dent (Shiraz) 16:1–9
33.
Zurück zum Zitat van der Meer WJ, Andriessen FS, Wismeijer D, Ren Y (2012) Application of intra-oral dental scanners in the digital workflow of implantology. PLoS One 7:e43312CrossRefPubMedPubMedCentral van der Meer WJ, Andriessen FS, Wismeijer D, Ren Y (2012) Application of intra-oral dental scanners in the digital workflow of implantology. PLoS One 7:e43312CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Wiranto MG, Engelbrecht WP, Nolthenius HET, van der Meer WJ, Rend Y (2013) Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions. Am J Orthod Dentofac Orthop 143:140–147CrossRef Wiranto MG, Engelbrecht WP, Nolthenius HET, van der Meer WJ, Rend Y (2013) Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions. Am J Orthod Dentofac Orthop 143:140–147CrossRef
35.
Zurück zum Zitat Yanping L, Shilei Z, Xiaojun C, Chengtao W (2006) A novel method in the design and fabrication of dental splints based on 3D simulation and rapid prototyping technology. Int J Adv Manuf 28:919–922CrossRef Yanping L, Shilei Z, Xiaojun C, Chengtao W (2006) A novel method in the design and fabrication of dental splints based on 3D simulation and rapid prototyping technology. Int J Adv Manuf 28:919–922CrossRef
36.
Zurück zum Zitat Zilberman O, Huggare JA, Parikakis KA (2003) Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models. Angle Orthod 73:301–306PubMed Zilberman O, Huggare JA, Parikakis KA (2003) Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models. Angle Orthod 73:301–306PubMed
Metadaten
Titel
Accuracy of stereolithographically printed digital models compared to plaster models
verfasst von
Leonardo Tavares Camardella
Oswaldo V. Vilella
Marleen M. van Hezel
Karel H. Breuning
Publikationsdatum
30.03.2017
Verlag
Springer Medizin
Erschienen in
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie / Ausgabe 5/2017
Print ISSN: 1434-5293
Elektronische ISSN: 1615-6714
DOI
https://doi.org/10.1007/s00056-017-0093-1

Weitere Artikel der Ausgabe 5/2017

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 5/2017 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.