Open Access 01.12.2021 | Research article

Comparison of the visual performance of iris-fixated phakic lens and implantable collamer lens to correct high myopia

verfasst von: Xiao-ling Jiao, Jun Li, Zhe Yu, Ping-hui Wei, Hui Song

Erschienen in: BMC Ophthalmology | Ausgabe 1/2021

Abstract

Background

To compare visual performance between the iris-fixated phakic intraocular len (pIOL) and implantable collamer len (ICL) to correct high myopia.

Methods

Twenty-four eyes underwent iris-fixated pIOL implantation and 24 eyes underwent ICL implantation. At the 6-month follow-up, the best-corrected visual acuity (BCVA) and uncorrected distance visual acuity (UDVA) were compared between the iris-fixated pIOL and ICL groups. The objective scatter index (OSI), modulation transfer function (MTF) cutoff, and ocular aberrations were performed to evaluate postoperative visual quality between the two groups.

Results

No significant difference was found in UDVA, BCVA, and spherical equivalent between the iris-fixated pIOL and ICL groups (P > 0.05). Six months after surgery, the following values were significantly higher in the ICL group than in the iris-fixated pIOL group: MTF cutoff, strehl ratio and optical quality analysis system values at contrasts of 9 %, 20 %, and 100 % (P < 0.01). The OSI in the iris-fixated pIOL group was higher than in the ICL group 6 months after surgery (P < 0.01). All high-order aberrations were slightly more severe in the iris-fixated pIOL group than in the ICL group 6 months after surgery, although only trefoil (P = 0.023) differed significantly in this regard.

Conclusions

Both iris-fixated lenses and ICLs can provide good visual acuity. ICLs confer better visual performance in MTF-associated parameters and induce less intraocular light scattering than iris-fixated pIOLs.
Hinweise
Xiao-ling Jiao and Jun Li should be considered co-first authors.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
pIOL
Phakic intraocular len
ICL
Implantable collamer len
BCVA
Best-corrected visual acuity
UDVA
Uncorrected distance visual acuity
OSI
Objective scatter index
MTF cutoff
Modulation transfer function cutoff
OV-100
Optical quality analysis system value at the contrast of 100 %
OV-20
Optical quality analysis system value at the contrast of 20 %
OV-9
Optical quality analysis system value at the contrast of 9 %
SE
Spherical equivalent

Background

Myopia is a significant public health issue in China [1]. Phakic intraocular len (pIOL) implantation and corneal laser refractive surgery are widely used to correct myopia, but small-incision lenticule extraction, laser-assisted in situ keratomileusis, and some other corneal laser surgeries are too risky in patients with severe myopia because of the cornea’s biomechanical limits [2]. However, pIOL implantation can be used regardless of corneal thickness and topography, and thus is more suitable in such patients. Moreover, recent studies have shown that pIOL implantation is efficacious and safe in low-to-moderate myopia, as well as in early keratoconus [3, 4]. Therefore, pIOL implantation is increasing in popularity.
According to the site of implantation, pIOLs are classified as iris-fixated pIOLs, posterior chamber lenses, and anterior chamber angle-supported lenses. However angle-supported pIOLs are associated with corneal endothelial cell loss, iris retraction, secondary glaucoma, and subsequent pupil ovalization and are rarely used [5, 6], while iris-fixated pIOLs and posterior chamber lenses are widely used and beneficial in high myopia [7, 8].
Previous studies have reported that implantation of iris-fixated pIOLs and implantable collamer lenses (ICLs) is safe, efficient, predictable, and stable [9, 10]. Iris-fixated pIOLs are always properly centered over the pupil, conferring stable vision. However, the rigid iris-fixated pIOLs require a larger incision in the sclera, which can increase astigmatism in the immediate postoperative period. Furthermore, peripheral iridectomy increases the risk associated with pIOL implantation, and the hole in the iris might cause light scattering. While the latest generation of posterior chamber ICL has an additional 360 μm central hole that can eliminate the need for peripheral iridectomy. They also increase aqueous humor circulation, nourishing the lens [11]. There are several studies compared the visual performance of iris-fixated pIOLs and ICLs [1214]. But the ICL without a central hole was evaluated in these studies. At present, the ICL with a central hole was widely used in clinic. But it remains unclear whether the central hole affects vision quality, aberration, and MTF profile of eye. In ICLs, the diameter of the optical zone changes from 4.5 to 5.8 mm. This limited size may lead to glare and halo, so subjective and objective vision quality must be further compared between iris-fixated pIOLs and ICLs with a central hole in the correction of high myopia.
Intraocular light scattering is an indicator of visual performance after surgery [15]. Increased intraocular light scattering in pseudophakic eyes can result in glare, halos. After iris-fixated pIOL implantation, peripheral iridectomy may induce more intraocular light scattering, as may the central hole in the ICL. The present study aimed to determine which types of pIOL induce less intraocular light scattering and to compare visual performance between iris-fixated pIOLs and ICLs.

Methods

Subjects and methods

The present retrospective study included 24 eyes of 12 patients (8 women, 4 men) implanted with an iris-fixated pIOL (Verisyse; Abbott Medical Optics, Santa Ana, USA) (iris-fixated pIOL group) between January 2011 and March 2015 and 24 eyes of 12 patients (7 women, 5 men) implanted with an ICL (Visian ICL v4c; STAAR Surgical, Nidau, Switzerland) (ICL group) between September 2018 and November 2020. All subjects were fully informed about the possible complications and the informed consents were obtained. All procedures were in accordance with the tenets of the Declaration of Helsinki, and the study protocol was approved by the local ethics committee (Tianjin Eye Hospital Ethics Committee).
The inclusion criteria were as follows: age ranged from 18 to 45 years, refractive error remaining stable for at least 2 years (change of < 0.5 D), anterior chamber depth ≥ 3.0 mm, high myopia ≥ 6 D, astigmatism < 1.0 D in both groups, endothelial cell density > 2200 cells/mm2, intraocular pressure (IOP) < 21 mmHg. The exclusion criteria were as follows: history of ocular surgery, ocular disease, such as retinal detachment, maculopathy, retinopathy, glaucoma, corneal opacities, or ocular inflammation.

Surgical technique

A Verisyse IOL (Verisyse; Abbott Medical Optics, Santa Ana, USA) was used in iris-fixated pIOL group. The iris-fixated pIOL power was calculated by using SRK/T formula and aimed to emmetropia. A 6.0-mm corneoscleral limbus incision was performed at the 11:30 o’clock position. Two 1.0-mm paracenteses were performed at the 2 and 10 o’clock positions. Carbamylcholine chloride (0.1 mL; Furuida Co., Shandong, China) was then injected into the anterior chamber. The iris-fixated pIOL was inserted into the anterior chamber and fixed to the iris using a special holder. The lens was enclavated between 3 and 9 o’clock, so that the haptics were oriented at the 3 and 9 o’clock positions. Peripheral iridectomy was performed at 12 o’clock to avoid pupillary block glaucoma. The viscoelastic substance was removed and the primary incision was closed using three interrupted 10 − 0 non-absorbable nylon sutures. Antibiotic and anti-inflammatory eye drops were administered and reduced gradually for 1 month. The corneal sutures were removed 3–4 weeks after surgery.
An ICL with a central hole (Visian ICL v4c; STAAR Surgical, Nidau, Switzerland) was implanted in ICL group. The size and power of ICL was calculated with formula provided by the manufacturer. The white-to-white and the anterior chamber depth measured by Pentacam system (Oculus; Wetzlar, Germany) codetermined the ICL size. Before surgery, topical 0.5 % tropicamide and 0.5 % phenylephrine eye drops (Mydrin-P; Santen Pharmaceutical) were used to sufficiently dilate the pupil. Proparacaine (Ruinian Best Pharmaceutical, Nanjing) was used to induce topical anesthesia. A 3.0-mm temporal corneal incision was then made. The V4c ICL was inserted into the anterior chamber through the corneal incision, and positioned into the ciliary sulcus. The viscoelastic substance was removed and the primary incision was hydrated. Antibiotic and anti-inflammatory eye drops were administered and reduced gradually for 1 month.

Ophthalmologic measurements

Ophthalmologic measurements were recorded immediately before and 6 months after surgery. The uncorrected distance visual acuity (UDVA), manifest refraction, best-corrected visual acuity (BCVA), endothelial cell count (ECC; Topcon SP-2000P; Topcon, Tokyo, Japan), IOP (TX-10 non-contact tonometer; Canon, Japan), axial length, and anterior chamber depth (IOLMaster; Carl Zeiss Meditec AG, Germany) were measured. At a pupil diameter of 4.0 mm and 6.0 mm, the spherical aberration, coma, trefoil, and root mean square of the total eye were measured using iTrace (Tracey Technology, Houston, TX, USA). The optical quality analysis system (OQAS) values at contrasts of 100 %, 20 %, and 9 % (OV-100, OV-20, and OV-9), modulation transfer function (MTF) cutoff, objective scatter index (OSI), and strehl ratio were measured using an OQAS (Visiometrics, Tarrasa, Spain). This system automatically corrects spherical refractive error between − 3 and + 3 D. Astigmatism and spherical refractive error of more than ± 3 D were corrected by placing an appropriate cylindrical or spherical lens in front of the eye. The parameters measured by the OQAS were under a 4.0-mm artificial pupil. Topical 0.5 % phenylephrine and 0.5 % tropicamide eye drops (Mydrin-P; Santen Pharmaceutical) were used to dilate the pupils before the iTrace and OQAS examinations, and at least 3 measurements were obtained. The entire ocular aberration was measured in the right eye of each subject with pupil diameter of 4.0 and 6.0 mm .

Statistical analysis

Data were presented as mean ± standard deviation and analyzed using SPSS for Windows 19.0 software (SPSS, Chicago, IL, USA). Snellen visual acuity was changed to the logarithm of the minimum angle of resolution (logMAR). The Shapiro–Wilk test was used to confirm the normality of data distribution. The generalized linear model was used to analyze the bilateral data for avoiding the bias caused by inter-eye correlation. For other data, the Student’s t-test and Mann–Whitney U test were used to analyze the parametric and non-parametric data, respectively. P values < 0.05 were considered significant.

Results

Follow-up and baseline comparisons

Table 1 shows the patients’ demographics. All were followed up for 6 months. No significant differences were found in mean spherical equivalent (SE), UDVA, or BCVA between two groups either before or 6 months after surgery (P > 0.05; Table 1). No intraoperative or severe postoperative complications occurred in any patient, such as posterior capsule rupture, hyphema, serious anterior chamber inflammation, damage to the crystalline lens or cornea, macular edema, or retinal detachment. Corneal edema was observed in four eyes after iris-fixated pIOL implantation; it disappeared 3 days after surgery. High IOP (≤ 30 mmHg) was observed in six eyes after ICL implantation. Carteolol hydrochloride eye drops (China Otsuka Pharmaceutical, Tianjin, China) were prescribed twice per day, and the IOP of all six eyes recovered within 5 days.
Table 1
Preoperative data and postoperative data in both groups
Characteristic
Iris-fixated pIOLs (n = 24)
ICL (n = 24)
P value
Age (years)
25.25 ± 1.76
25.58 ± 1.73
0.645
Gender (male : female)
4:8
5:7
0.673
Preop.
 UDVA (LogMAR)
1.22 ± 0.48
1.14 ± 0.47
0.338
 BCVA (LogMAR)
0.03 ± 0.04
0.02 ± 0.04
0.677
 Mean sphere (D)
-12.84 ± 1.87
-12.96 ± 2.11
0.844
 Mean cylinder (D)
-0.06 ± 0.83
-0.23 ± 0.81
0.469
 Mean SE (D)
-12.95 ± 1.75
-12.98 ± 2.18
0.956
 Axial length (mm)
28.15 ± 1.44
28.17 ± 1.57
0.971
 Anterior chamber depth (mm)
3.43 ± 0.11
3.41 ± 0.10
0.554
Postop.
 UDVA (LogMAR)
-0.09 ± 0.08
-0.05 ± 0.05
0.949
 BCVA (LogMAR)
-0.05 ± 0.07
-0.33 ± 0.06
0.470
 Mean sphere (D)
-0.21 ± 0.23
-0.14 ± 0.27
0.089
 Mean cylinder (D)
-0.14 ± 0.79
-0.05 ± 0.81
0.421
 Mean SE (D)
-0.28 ± 0.37
-0.11 ± 0.47
0.178
UDVA Uncorrected distant visual acuity, BCVA Best corrected distant visual acuity, SE spherical equivalent
Six months after surgery, the UCVA was 20/20 or better in 16 of 24 eyes (67 %) in the iris-fixated pIOL group, as well as in 18 of 24 eyes (75 %) in the ICL group (Fig. 1a). Meanwhile, the BCVA was 20/20 or better in 24 of 24 eyes (100 %) in the iris-fixated pIOL group, as well as in 24 of 24 eyes (100 %) in the ICL group (Fig. 1b).
Figure 2 shows the achieved vs. attempted SE correction in both groups 6 months after surgery. When the SE was evaluated in the iris-fixated pIOL group at 6 months, 79 % of the eyes were within ± 0.50 D of emmetropia, while 96 % were within ± 1.00 D. Meanwhile, in the ICL group, 83 % of eyes were within ± 0.50 D of emmetropia, and 100 % were within ± 1.00 D.

Corneal endothelial cell loss

Table 2 shows the endothelial cell loss in both groups. The rate of endothelial cell density loss did not differ significantly between the iris-fixated pIOL and ICL groups 6 months after implantation surgery.
Table 2
Corneal endothelial cell density and optical quality parameters six months after surgery
 
Iris-fixated pIOLs
ICL
P value
Preop. ECD (cells/mm2)
3012 ± 113
3020 ± 135
0.579
Postop. ECD (cells/mm2)
2888 ± 131
2866 ± 127
0.223
ECD loss rate(%)
4.44 ± 2.44
5.03 ± 3.51
0.110
MTF cutoff frequency (cycle/degree)
21.34 ± 10.23
31.86 ± 10.81
< 0.001#
Strehl ratio
0.13 ± 0.06
0.16 ± 0.05
0.007#
OV 100 %
0.72 ± 0.34
0.98 ± 0.37
< 0.001#
OV 20 %
0.49 ± 0.27
0.67 ± 0.30
< 0.001#
OV 9 %
0.22 ± 0.10
0.46 ± 0.18
< 0.001#
OSI
2.77 ± 1.68
1.69 ± 1.11
< 0.001#
ECD Endothelial cell density, MTF modulation transfer function, OSI objective scattering index, OV Optical Quality Analysis System (OQAS) value; * = < 0.05; # = < 0.01

Visual quality comparison

MTF is the contrast ratio between the retinal image and the original scene, and the MTF cutoff is the spatial frequency at 1 % of the maximum MTF. OV-9 and OV-20 are 1 and 5 % of the MTF, respectively. OV-100 is defined as the MTF cutoff frequency which is divided by 30 cycles per degree [16]. Comparison of aberration between iris-fixated pIOLs and ICLs was performed with a pupil diameter of 4 mm and 6 mm. MTF cutoff, OQAS values, and strehl ratio were lower in the iris-fixated pIOL group than in the ICL group 6 months after surgery, while the OSI values were higher (Table 2). There were significant differences in OV-100, OV-20, OV-9, MTF cutoff, Strehl ratio and OSI between the two groups (P < 0.05).

Aberration comparison

Almost all aberrations were slightly more severe in the iris-fixated pIOL group than in the ICL group 6 months after surgery, specifically total aberrations, total low-order aberrations (tLOAs), total high-order aberrations (tHOAs), defocus, spherical aberrations, astigmatism, trefoil, and coma, although the difference was only significant for trefoil (P < 0.05) (Table 3).
Table 3
Aberration parameters in both groups
Internal aberrations
Pupil diameter
Iris-fixated pIOLs
ICL
P2 value
TA/D
4mm
1.08±.074
0.64±0.34
0.070
6mm
2.23±1.5
1.47±0.89
0.147
P1 value
0.026*
0.006#
 
tLOAs/D
4mm
0.88±0.60
0.54±0.35
0.101
6mm
1.5±0.91
1.13±0.61
0.243
P1 value
0.059
0.008#
 
Defocus/D
4mm
0.62±0.58
0.34±0.27
0.151
6mm
0.76±0.57
0.72±0.58
0.853
P1 value
0.549
0.058
 
Astigmatism/D
4mm
0.51±0.4
0.25±0.24
0.066
6mm
1.93±2.97
0.73±0.51
0.182
P1 value
0.115
0.008#
 
tHOAs/D
4mm
0.40±0.41
0.23±0.24
0.237
6mm
1.52±1.41
0.82±0.76
0.144
P1 value
0.015*
0.019*
 
Coma/D
4mm
0.37±0.52
0.1±0.11
0.098
6mm
0.58±0.47
0.44±0.54
0.507
P1 value
0.322
0.048*
 
Spherical/D
4mm
0.17±0.30
0.05±0.1
0.212
6mm
0.15±0.30
0.24±0.33
0.500
P1 value
0.867
0.080
 
Trefoil/D
4mm
0.29±0.30
0.08±0.05
0.023*
6mm
0.83±0.97
0.27±0.21
0.062
P1 value
0.079
0.008#
 
P1 = P value for 4mm and 6mm comparison in the same group; P2 = P value for comparison between iris-fixated pIOL group and ICL group
TA total aberration, tHOAs total high-order aberration, tLOAs total low-order aberration
* = P < 0.05; # = P < 0.01

Discussion

Previous studies have shown that implantation of iris-fixated pIOL and ICL is efficacious and safe for correcting high myopia [9, 16], and one meta-analysis showed no statistic difference in efficacy or safety between the two pIOLs [17]. In the present study, both iris-fixated pIOLs and ICLs markedly improved UCVA and BCVA, and no significant difference was found between the two, which was consistent with Awadein et al’s study [18].
Although rigid iris-fixated pIOLs require larger incision sizes, refractive results in the iris-fixated pIOL group were similar to those in the ICL group 6 months after surgery in the present study. In both groups, the postoperative SE was close to zero, with approximately 95 % of eyes within ± 1.00 D of emmetropia. The different incision sizes seemed not to affect postoperative astigmatism in iris-fixated pIOL group. Our results were consistent with those of Tahzib et al. [19], who compared refractive data after implantation of iris-fixated rigid and foldable pIOLs (Artiflex), finding that postoperative refractive astigmatism only differed significantly between groups after 1 week of follow-up, and that it was comparable after suture removal. Moreover, Coullet et al. [20] found no significant difference in postoperative astigmatism between foldable and rigid iris-fixated pIOLs beyond 3 months after surgery. In both studies, the corneal incision was closed with five or six interrupted sutures, which may have markedly decreased surgically induced astigmatism. In our study, the corneal limbus incision was closed using three interrupted sutures after iris-fixated pIOL implantation, and the sutures were removed 3–4 weeks after surgery.
The present research revealed that the values of MTF cutoff, strehl ratio, OV-100, OV-20, and OV-9 in the ICL group were significantly higher than in the iris-fixated pIOL group. Nochez et al. [21] showed that trefoil was associated with objective contrast sensitivity. In the present study, the postoperative trefoil value in the ICL group was markedly lower than in the iris-fixated pIOL group with the pupil diameter of 4.0 mm. With the pupil diameter of 6.0 mm, the postoperative trefoil value in the ICL group was lower than iris-fixated pIOL group, but there was no significant difference between the two groups. Perhaps the postoperative trefoil affected the MTF associated parameters. The relationship between MTF and higher-order aberrations requires further study.
The OSI, measured using OQAS, quantifies intraocular scattered light. Lower OSI corresponds to better optical quality [22]. The OSI was significantly higher in the iris-fixated pIOL group than in the ICL group after surgery in the present study. The ICL was placed into the ciliary sulcus behind the pupil, while the iris-fixated pIOL was enclavated to the iris in front of the pupil. In iris-fixated pIOL group, light leakage caused by peripheral iridectomy may increase intraocular scattered light, and iris-fixated pIOLs may cause greater trauma to the iris, manifesting as iris atrophy and pigment spread, both of which are irreversible and can affect direction of light. Our previous study has shown the ICL with a central hole doesn’t increase the intraocular light scattering [23]. Qin et al. [24] confirmed that ICLs induce less intraocular light scattering because they are rarely tilted or decentralized and their optical zone thickness is only 50–60 μm. As we know, the pupil diameter may be greater than 4.0 mm at night. The results of intraocular light scattering in this study can’t reflect the situation at night. However, further studies are needed to clarify this.
Alio and associates [12] compared intraocular aberrations in eight kind of phakic intraocular lens implantation by KR-1w, and discussed the impact on visual acuity that could appear after pIOL implantation. We used an iTrace visual function analyzer to evaluate HOAs after surgery and thus compare visual performance between iris-fixated pIOLs and ICLs. Alio et al. and Awadein et al. [12, 18] found no significant difference in HOAs and astigmatism between iris-fixated pIOLs and posterior chamber pIOLs at 4.0 mm and 6.0 mm pupil. Our results were in accordance with previous studies.
Alio et al. [12] found the values of postoperative coma in ICL group were significantly lower than iris-fixated pIOL group. In our study, the postoperative coma in ICL group was lower than iris-fixated pIOL group with a pupil diameter of 4.0mm and 6.0 mm, but no significant difference was observed between two groups. The aberration results were also consistent with Awadein et al.’s study [18]. The IOL decentration and tilt usually are the main reason to increase coma after IOL implantation [25]. The ICL was positioned in the ciliary sulcus, while the iris-fixated pIOL was enclavated to the iris. The difference of iris tissue enclavated by the bilateral Verisyse claws may lead to the decentration and tilt of the pIOL optic, which may result in the higher postoperative coma.
Our results showed a difference in ocular aberrations between the pupil diameter of 4.0 mm and 6.0 mm in ICL group. The small pupil diameter can lead to small HOAs. And ocular aberrations are known to increase with pupil diameter [26, 27]. Wang et al.’s [28] study also observed the coma-like aberration, spherical aberration, and other HOAs increased with the pupil size.
Karimian et al. [13] found the high order aberrations and spherical aberration were higher in iris-fixated than ICL group. But in our study no significant difference was observed in HOAs and spherical aberration between two pIOLs. Two reasons may result in this discrepancy. First, the mean age of Artiflex group was 30, while the mean age of ICL group was 27 in Karimian et al.’s study. The corneal HOAs and spherical aberration increases with age [26], which may result in the difference between the two groups; Second, aspherical IOL implantation generates fewer positive spherical aberrations than spherical IOL implantation after cataract surgery, leading to better contrast sensitivity and visual acuity [26]. Neither iris-fixated pIOLs nor ICLs have aspherical optic designs, which may be why there was no significant difference in spherical aberration between two groups in the present study.
In our study the postoperative trefoil in iris-fixated pIOL group was higher than ICL group. In the present study, a 6.0-mm corneoscleral limbus incision was performed in iris-fixated pIOL group, while a 3.0-mm temporal corneal incision was performed in ICL group. The larger corneal incision can increase the trefoil [29]. Tong et al. [30] also found the value of postoperative trefoil is dependent on incision size. The larger incision in rigid iris-fixated pIOL group may lead to higher postoperative trefoil in iris-fixated pIOL group.
Our study had several limitations. The follow-up time was insufficient and the sample size was small. Further study on big sample is needed. A previous study showed that visual acuity and refractive power become stable 1 month after ICL implantation surgery [31]. We compared clinical outcomes between groups 6 months after surgery, but long-term follow-up is necessary in future studies. However, further study is needed to confirm this conjecture.

Conclusions

In conclusion, iris-fixated pIOLs and ICLs can provide good UCVA. ICL shows better visual performance than iris-fixated pIOL in MTF-associated parameters and induce less intraocular light scattering.

Acknowledgements

Not applicable.

Declarations

All procedures were in accordance with the tenets of the Declaration of Helsinki, and the study protocol was approved by the Tianjin Eye Hospital Ethics Committee. Written informed consent was obtained from all participants. Xiao-ling Jiao and Jun Li are co-first authors.
Not applicable.

Competing interests

The authors declare that there is no conflict of interest regarding this paper.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Li Y, Liu J, Qi P. The increasing prevalence of myopia in junior high school students in the Haidian District of Beijing, China: a 10-year population-based survey. BMC Ophthalmol. 2017;17:88.CrossRef Li Y, Liu J, Qi P. The increasing prevalence of myopia in junior high school students in the Haidian District of Beijing, China: a 10-year population-based survey. BMC Ophthalmol. 2017;17:88.CrossRef
2.
Zurück zum Zitat Seiler T, Koufala K, Richter G. Iatrogenic keratectasia after laser in situ keratomileusis. J Refract Surg. 1998;14:312–317.CrossRef Seiler T, Koufala K, Richter G. Iatrogenic keratectasia after laser in situ keratomileusis. J Refract Surg. 1998;14:312–317.CrossRef
3.
Zurück zum Zitat Kamiya K, Shimizu K, Igarashi A, Kitazawa Y, Kojima T, Nakamura T, Oka Y, Matsumoto R. Posterior chamber phakic intraocular lens implantation: comparative, multicentre study in 351 eyes with low-to-moderate or high myopia. Br J Ophthalmol. 2018;102:177–81.CrossRef Kamiya K, Shimizu K, Igarashi A, Kitazawa Y, Kojima T, Nakamura T, Oka Y, Matsumoto R. Posterior chamber phakic intraocular lens implantation: comparative, multicentre study in 351 eyes with low-to-moderate or high myopia. Br J Ophthalmol. 2018;102:177–81.CrossRef
4.
Zurück zum Zitat Alió JL, Peña-García P, Abdulla GF, Zein G, Abu-Mustafa SK. Comparison of iris-claw and posterior chamber collagen copolymer phakic intraocular lenses in keratoconus. J Cataract Refract Surg. 2014;40:383–94.CrossRef Alió JL, Peña-García P, Abdulla GF, Zein G, Abu-Mustafa SK. Comparison of iris-claw and posterior chamber collagen copolymer phakic intraocular lenses in keratoconus. J Cataract Refract Surg. 2014;40:383–94.CrossRef
5.
Zurück zum Zitat Ardjomand N, Kölli H, Vidic B, El-Shabrawi Y, Faulborn J. Pupillary block after phakic anterior chamber intraocular lens implantation. J Cataract Refract Surg. 2002;28:1080–1.CrossRef Ardjomand N, Kölli H, Vidic B, El-Shabrawi Y, Faulborn J. Pupillary block after phakic anterior chamber intraocular lens implantation. J Cataract Refract Surg. 2002;28:1080–1.CrossRef
6.
Zurück zum Zitat Kohnen T. Searching for the perfect phakic intraocular lens. J Cataract Refract Surg. 2000;26:1261–2.CrossRef Kohnen T. Searching for the perfect phakic intraocular lens. J Cataract Refract Surg. 2000;26:1261–2.CrossRef
7.
Zurück zum Zitat Güell JL, Morral M, Gris O, Gaytan J, Sisquella M, Manero F. Five-year follow-up of 399 phakic Artisan-Verisyse implantation for myopia, hyperopia, and/or astigmatism. Ophthalmology. 2008;115:1002–12.CrossRef Güell JL, Morral M, Gris O, Gaytan J, Sisquella M, Manero F. Five-year follow-up of 399 phakic Artisan-Verisyse implantation for myopia, hyperopia, and/or astigmatism. Ophthalmology. 2008;115:1002–12.CrossRef
8.
Zurück zum Zitat Kojima T, Kitazawa Y, Nakamura T, Takahashi M, Kamiya K, Ichikawa K, Igarashi A, Shimizu K. Prospective Randomized Multicenter Comparison of the Clinical Outcomes of V4c and V5 Implantable Collamer Lenses: A Contralateral Eye Study. J Ophthalmol. 2018;2018:7623829.CrossRef Kojima T, Kitazawa Y, Nakamura T, Takahashi M, Kamiya K, Ichikawa K, Igarashi A, Shimizu K. Prospective Randomized Multicenter Comparison of the Clinical Outcomes of V4c and V5 Implantable Collamer Lenses: A Contralateral Eye Study. J Ophthalmol. 2018;2018:7623829.CrossRef
9.
Zurück zum Zitat van Rijn GA, Gaurisankar ZS, Ilgenfritz AP, Lima JEE, Haasnoot GW, Beenakker JM, Cheng YYY, Luyten GPM. Middle- and long-term results after iris-fixated phakic intraocular lens implantation in myopic and hyperopic patients: a meta-analysis. J Cataract Refract Surg. 2020;46:125–37.CrossRef van Rijn GA, Gaurisankar ZS, Ilgenfritz AP, Lima JEE, Haasnoot GW, Beenakker JM, Cheng YYY, Luyten GPM. Middle- and long-term results after iris-fixated phakic intraocular lens implantation in myopic and hyperopic patients: a meta-analysis. J Cataract Refract Surg. 2020;46:125–37.CrossRef
10.
Zurück zum Zitat Packer M. The Implantable Collamer Lens with a central port: review of the literature. Clin Ophthalmol. 2018;12:2427–2438.CrossRef Packer M. The Implantable Collamer Lens with a central port: review of the literature. Clin Ophthalmol. 2018;12:2427–2438.CrossRef
11.
Zurück zum Zitat Langeslag MJ, van der Mooren M, Beiko GH, Piers PA. Impact of intraocular lens material and design on light scatter: In vitro study. J Cataract Refract Surg. 2014;40:2120–7.CrossRef Langeslag MJ, van der Mooren M, Beiko GH, Piers PA. Impact of intraocular lens material and design on light scatter: In vitro study. J Cataract Refract Surg. 2014;40:2120–7.CrossRef
12.
Zurück zum Zitat Alio JL, Peña-García P, Pachkoria K, Alio JL 2nd, Aswad E. A. Intraocular optical quality of phakic intraocular lenses: comparison of angle-supported, iris-fixated, and posterior chamber lenses. Am J Ophthalmol. 2013;156:789–99. Alio JL, Peña-García P, Pachkoria K, Alio JL 2nd, Aswad E. A. Intraocular optical quality of phakic intraocular lenses: comparison of angle-supported, iris-fixated, and posterior chamber lenses. Am J Ophthalmol. 2013;156:789–99.
13.
Zurück zum Zitat Karimian F, Baradaran-Rafii A, Hashemian SJ, Hashemloo A, Jafari ME, Yaseri M, Ghahari E, Akbarian S. Comparison of three phakic intraocular lenses for correction of myopia. J Ophthal Vis Res. 2014;9:427–33.CrossRef Karimian F, Baradaran-Rafii A, Hashemian SJ, Hashemloo A, Jafari ME, Yaseri M, Ghahari E, Akbarian S. Comparison of three phakic intraocular lenses for correction of myopia. J  Ophthal Vis Res. 2014;9:427–33.CrossRef
14.
Zurück zum Zitat Lee SY, Kwon HJ, Ahn HS, Seo KY, Kim EK, Kim TI. Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens. Eye. 2011;25:1409–17.CrossRef Lee SY, Kwon HJ, Ahn HS, Seo KY, Kim EK, Kim TI. Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens. Eye. 2011;25:1409–17.CrossRef
15.
Zurück zum Zitat Rizk IM, Al-Hessy AA, El-Khouly SE, Sewelam AM. Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia. Int J Ophthalmol. 2019;12:284–90.PubMedPubMedCentral Rizk IM, Al-Hessy AA, El-Khouly SE, Sewelam AM. Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia. Int J Ophthalmol. 2019;12:284–90.PubMedPubMedCentral
16.
Zurück zum Zitat He T, Zhu Y, Zhou J. Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions. BMC Ophthalmol. 2020;20:82.CrossRef He T, Zhu Y, Zhou J. Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions. BMC Ophthalmol. 2020;20:82.CrossRef
17.
Zurück zum Zitat Liang GL, Wu J, Shi JT, Liu J, He FY, Xu W. Implantable collamer lens versus iris-fixed phakic intraocular lens implantation to correct myopia: a meta-analysis. PloS one. 2014;9:e104649.CrossRef Liang GL, Wu J, Shi JT, Liu J, He FY, Xu W. Implantable collamer lens versus iris-fixed phakic intraocular lens implantation to correct myopia: a meta-analysis. PloS one. 2014;9:e104649.CrossRef
18.
Zurück zum Zitat Awadein A, Habib AE. ICL versus Veriflex phakic IOL for treatment of moderately high myopia: randomized paired-eye comparison. J Refract Surg. 2013;29:445–452.CrossRef Awadein A, Habib AE. ICL versus Veriflex phakic IOL for treatment of moderately high myopia: randomized paired-eye comparison. J Refract Surg. 2013;29:445–452.CrossRef
19.
Zurück zum Zitat Tahzib NG, MacRae SM, Yoon G, Berendschot TT, Eggink FA, Hendrikse F, Nuijts RM. Higher-order aberrations after implantation of iris-fixated rigid or foldable phakic intraocular lenses. J Cataract Refract Surg. 2008;34:1913–20.CrossRef Tahzib NG, MacRae SM, Yoon G, Berendschot TT, Eggink FA, Hendrikse F, Nuijts RM. Higher-order aberrations after implantation of iris-fixated rigid or foldable phakic intraocular lenses. J Cataract Refract Surg. 2008;34:1913–20.CrossRef
20.
Zurück zum Zitat Coullet J, Guëll JL, Fournié P, Grandjean H, Gaytan J, Arné JL, Malecaze F. Iris-supported phakic lenses (rigid vs foldable version) for treating moderately high myopia: randomized paired eye comparison. Am J Ophthalmol. 2006;142:909–16.CrossRef Coullet J, Guëll JL, Fournié P, Grandjean H, Gaytan J, Arné JL, Malecaze F. Iris-supported phakic lenses (rigid vs foldable version) for treating moderately high myopia: randomized paired eye comparison. Am J Ophthalmol. 2006;142:909–16.CrossRef
21.
Zurück zum Zitat Nochez Y, Majzoub S, Pisella PJ. Effect of interaction of macroaberrations and scattered light on objective quality of vision in pseudophakic eyes with aspheric monofocal intraocular lenses. J Cataract Refract Surg. 2012;38:633–40.CrossRef Nochez Y, Majzoub S, Pisella PJ. Effect of interaction of macroaberrations and scattered light on objective quality of vision in pseudophakic eyes with aspheric monofocal intraocular lenses. J Cataract Refract Surg. 2012;38:633–40.CrossRef
22.
Zurück zum Zitat Xu CC, Xue T, Wang QM, Zhou YN, Huang JH, Yu AY. Repeatability and reproducibility of a double-pass optical quality analysis device. PloS one. 2015;10:e0117587.CrossRef Xu CC, Xue T, Wang QM, Zhou YN, Huang JH, Yu AY. Repeatability and reproducibility of a double-pass optical quality analysis device. PloS one. 2015;10:e0117587.CrossRef
23.
Zurück zum Zitat Yu Z, Li J, Song H. Short-time evaluation on intraocular scattering after implantable collamer lens implantation for correcting high myopia. BMC Ophthalmol. 2020;20:235.CrossRef Yu Z, Li J, Song H. Short-time evaluation on intraocular scattering after implantable collamer lens implantation for correcting high myopia. BMC Ophthalmol. 2020;20:235.CrossRef
24.
Zurück zum Zitat Qin Q, Bao L, Yang L, He Z, Huang Z. Comparison of visual quality after EVO-ICL implantation and SMILE to select the appropriate surgical method for high myopia. BMC Ophthalmol. 2019;19:21.CrossRef Qin Q, Bao L, Yang L, He Z, Huang Z. Comparison of visual quality after EVO-ICL implantation and SMILE to select the appropriate surgical method for high myopia. BMC Ophthalmol. 2019;19:21.CrossRef
25.
Zurück zum Zitat Lawu T, Mukai K, Matsushima H, Senoo T. Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye. J Cataract Refract Surg. 2019;45:662–8.CrossRef Lawu T, Mukai K, Matsushima H, Senoo T. Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye. J Cataract Refract Surg. 2019;45:662–8.CrossRef
26.
Zurück zum Zitat Awwad ST, El-Kateb M, McCulley JP. Comparative higher-order aberration measurement of the LADARWave and Visx WaveScan aberrometers at varying pupil sizes and after pharmacologic dilation and cycloplegia. J Cataract Refract Surg. 2006;32:203–14.CrossRef Awwad ST, El-Kateb M, McCulley JP. Comparative higher-order aberration measurement of the LADARWave and Visx WaveScan aberrometers at varying pupil sizes and after pharmacologic dilation and cycloplegia. J Cataract Refract Surg. 2006;32:203–14.CrossRef
27.
Zurück zum Zitat McKelvie J, McArdle B, McGhee C. The influence of tilt, decentration, and pupil size on the higher-order aberration profile of aspheric intraocular lenses. Ophthalmology. 2011;118:1724–31.CrossRef McKelvie J, McArdle B, McGhee C. The influence of tilt, decentration, and pupil size on the higher-order aberration profile of aspheric intraocular lenses. Ophthalmology. 2011;118:1724–31.CrossRef
28.
Zurück zum Zitat Wang Y, Zhao K, Jin Y, Niu Y, Zuo T. Changes of higher order aberration with various pupil sizes in the myopic eye. J Refract Surg. 2003;19:S270-274.CrossRef Wang Y, Zhao K, Jin Y, Niu Y, Zuo T. Changes of higher order aberration with various pupil sizes in the myopic eye. J Refract Surg. 2003;19:S270-274.CrossRef
29.
Zurück zum Zitat Can İ, Bayhan HA, Çelik H, Ceran BB. Comparison of corneal aberrations after biaxial microincision and microcoaxial cataract surgeries: a prospective study. Curr Eye Res. 2012;37:18–24.CrossRef Can İ, Bayhan HA, Çelik H, Ceran BB. Comparison of corneal aberrations after biaxial microincision and microcoaxial cataract surgeries: a prospective study. Curr Eye Res. 2012;37:18–24.CrossRef
30.
Zurück zum Zitat Tong N, He JC, Lu F, Wang Q, Qu J, Zhao YE. Changes in corneal wavefront aberrations in microincision and small-incision cataract surgery. J Cataract Refract Surg. 2008;34:2085–90.CrossRef Tong N, He JC, Lu F, Wang Q, Qu J, Zhao YE. Changes in corneal wavefront aberrations in microincision and small-incision cataract surgery. J Cataract Refract Surg. 2008;34:2085–90.CrossRef
31.
Zurück zum Zitat Sanders DR. Matched population comparison of the Visian Implantable Collamer Lens and standard LASIK for myopia of -3.00 to -7.88 diopters. J Refract Surg. 2007; 23:537–553. Sanders DR. Matched population comparison of the Visian Implantable Collamer Lens and standard LASIK for myopia of -3.00 to -7.88 diopters. J Refract Surg. 2007; 23:537–553.
Metadaten
Titel
Comparison of the visual performance of iris-fixated phakic lens and implantable collamer lens to correct high myopia
verfasst von
Xiao-ling Jiao
Jun Li
Zhe Yu
Ping-hui Wei
Hui Song
Publikationsdatum
01.12.2021
Verlag
BioMed Central
Erschienen in
BMC Ophthalmology / Ausgabe 1/2021
Elektronische ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-021-01995-3

Weitere Artikel der Ausgabe 1/2021

BMC Ophthalmology 1/2021 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Metastase in der periokulären Region

Metastasen Leitthema

Orbitale und periokuläre metastatische Tumoren galten früher als sehr selten. Aber mit der ständigen Aktualisierung von Medikamenten und Nachweismethoden für die Krebsbehandlung werden neue Chemotherapien und Strahlenbehandlungen eingesetzt. Die …

Staging und Systemtherapie bei okulären und periokulären Metastasen

Metastasen Leitthema

Metastasen bösartiger Erkrankungen sind die häufigsten Tumoren, die im Auge diagnostiziert werden. Sie treten bei ungefähr 5–10 % der Patienten mit soliden Tumoren im Verlauf der Erkrankung auf. Besonders häufig sind diese beim Mammakarzinom und …

CME: Wundheilung nach Trabekulektomie

Trabekulektomie CME-Artikel

Wird ein Glaukom chirurgisch behandelt, ist die anschließende Wundheilung von entscheidender Bedeutung. In diesem CME-Kurs lernen Sie, welche Pathomechanismen der Vernarbung zugrunde liegen, wie perioperativ therapiert und Operationsversagen frühzeitig erkannt werden kann.

„standard operating procedures“ (SOP) – Vorschlag zum therapeutischen Management bei periokulären sowie intraokulären Metastasen

Metastasen Leitthema

Peri- sowie intraokuläre Metastasen sind insgesamt gesehen selten und meist Zeichen einer fortgeschrittenen primären Tumorerkrankung. Die Therapie ist daher zumeist palliativ und selten kurativ. Zudem ist die Therapiefindung sehr individuell. Die …

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.